{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T23:10:55Z","timestamp":1789081855003,"version":"build-2803163510"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2024,5,30]],"date-time":"2024-05-30T00:00:00Z","timestamp":1717027200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,5,30]],"date-time":"2024-05-30T00:00:00Z","timestamp":1717027200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001871","name":"Funda\u00e7\u00e3o para a Ci\u00eancia e a Tecnologia","doi-asserted-by":"publisher","award":["2022.12136.BDANA"],"award-info":[{"award-number":["2022.12136.BDANA"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001871","name":"Funda\u00e7\u00e3o para a Ci\u00eancia e a Tecnologia","doi-asserted-by":"publisher","award":["UIDB\/00048\/2020"],"award-info":[{"award-number":["UIDB\/00048\/2020"]}],"id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Arthroscopic surgery, with its inherent difficulties on visibility and maneuverability inside the joint, poses significant challenges to surgeons. Video-based surgical navigation (VBSN) has proven to have clinical benefits in arthroscopy but relies on a time-consuming and challenging surface digitization using a touch probe to accomplish registration of intraoperative data with preoperative anatomical models. This paper presents an off-the-shelf laser scanner for noninvasive registration that enables an increased area of reachable region.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Our solution uses a standard arthroscope and a light projector with visual markers for real-time extrinsic calibration. Nevertheless, the shift from a touch probe to a laser scanner introduces a new challenge\u2014the presence of a significant amount of outliers resulting from the reconstruction of nonrigid structures. To address this issue, we propose to identify the structures of interest prior to reconstruction using a deep learning-based semantic segmentation technique.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Experimental validation using knee and hip phantoms, as well as ex-vivo data, assesses the laser scanner\u2019s effectiveness. The integration of the segmentation model improves results in ex-vivo experiments by mitigating outliers. Specifically, the laser scanner with the segmentation model achieves registration errors below 2.2 mm, with the intercondylar region exhibiting errors below 1\u00a0mm. In experiments with phantoms, the errors are always below 1\u00a0mm.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The results show the viability of integrating the laser scanner with VBSN as a noninvasive and potential alternative to traditional methods by overcoming surface digitization challenges and expanding the reachable region. Future efforts aim to improve hardware to further optimize performance and applicability in complex procedures.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s11548-024-03180-5","type":"journal-article","created":{"date-parts":[[2024,5,30]],"date-time":"2024-05-30T16:26:03Z","timestamp":1717086363000},"page":"1429-1437","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Structured light for touchless 3D registration in video-based surgical navigation"],"prefix":"10.1007","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1130-3499","authenticated-orcid":false,"given":"T\u00e2nia","family":"Baptista","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miguel","family":"Marques","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carolina","family":"Raposo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lu\u00eds","family":"Ribeiro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michel","family":"Antunes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joao P.","family":"Barreto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,5,30]]},"reference":[{"issue":"5","key":"3180_CR1","doi-asserted-by":"publisher","first-page":"624","DOI":"10.1302\/0301-620X.94B5.28627","volume":"94\u2013B","author":"E Audenaert","year":"2012","unstructured":"Audenaert E, Smet B, Pattyn C, Khanduja V (2012) Imageless versus image-based registration in navigated arthroscopy of the hip. J Bone Joint Surg 94\u2013B(5):624\u2013629. https:\/\/doi.org\/10.1302\/0301-620X.94B5.28627","journal-title":"J Bone Joint Surg"},{"key":"3180_CR2","doi-asserted-by":"publisher","unstructured":"Besl PJ, McKay ND (1992) Method for registration of 3-D shapes. In: Sensor Fusion IV: Control Paradigms and Data Structures, International Society for Optics and Photonics, 1611: 586\u2013606, https:\/\/doi.org\/10.1117\/12.57955","DOI":"10.1117\/12.57955"},{"issue":"11","key":"3180_CR3","doi-asserted-by":"publisher","first-page":"3119","DOI":"10.1364\/BOE.2.003119","volume":"2","author":"NT Clancy","year":"2011","unstructured":"Clancy NT, Stoyanov D, Maier-Hein L, Groch A, Yang GZ, Elson DS (2011) Spectrally encoded fiber-based structured lighting probe for intraoperative 3D imaging. Biomed Opt Express 2(11):3119\u20133128. https:\/\/doi.org\/10.1364\/BOE.2.003119","journal-title":"Biomed Opt Express"},{"issue":"1","key":"3180_CR4","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1016\/j.media.2015.04.008","volume":"25","author":"P Edgcumbe","year":"2015","unstructured":"Edgcumbe P, Pratt P, Yang GZ, Nguan C, Rohling R (2015) Pico Lantern: surface reconstruction and augmented reality in laparoscopic surgery using a pick-up laser projector. Med Image Anal 25(1):95\u2013102. https:\/\/doi.org\/10.1016\/j.media.2015.04.008","journal-title":"Med Image Anal"},{"issue":"6","key":"3180_CR5","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1145\/358669.358692","volume":"24","author":"MA Fischler","year":"1981","unstructured":"Fischler MA, Bolles RC (1981) Random sample consensus: a paradigm for model fitting with applications to image analysis and automated cartography. Commun ACM 24(6):381\u2013395. https:\/\/doi.org\/10.1145\/358669.358692","journal-title":"Commun ACM"},{"issue":"11","key":"3180_CR6","doi-asserted-by":"publisher","first-page":"1231","DOI":"10.1177\/0278364913491297","volume":"32","author":"A Geiger","year":"2013","unstructured":"Geiger A, Lenz P, Stiller C, Urtasun R (2013) Vision meets robotics: the kitti dataset. Int J Robot Res 32(11):1231\u20131237","journal-title":"Int J Robot Res"},{"issue":"4","key":"3180_CR7","doi-asserted-by":"publisher","first-page":"509","DOI":"10.1016\/j.media.2006.03.001","volume":"10","author":"M Hayashibe","year":"2006","unstructured":"Hayashibe M, Suzuki N, Nakamura Y (2006) Laser-scan endoscope system for intraoperative geometry acquisition and surgical robot safety management. Med Image Anal 10(4):509\u2013519. https:\/\/doi.org\/10.1016\/j.media.2006.03.001","journal-title":"Med Image Anal"},{"issue":"2","key":"3180_CR8","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1016\/j.knee.2016.12.007","volume":"24","author":"Y Kim","year":"2017","unstructured":"Kim Y, Lee BH, Mekuria K, Cho H, Park S, Wang JH, Lee D (2017) Registration accuracy enhancement of a surgical navigation system for anterior cruciate ligament reconstruction: a phantom and cadaveric study. Knee 24(2):329\u2013339. https:\/\/doi.org\/10.1016\/j.knee.2016.12.007","journal-title":"Knee"},{"key":"3180_CR9","doi-asserted-by":"publisher","unstructured":"Lin J, Clancy NT, Stoyanov D, Elson DS (2015) Tissue surface reconstruction aided by local normal information using a self-calibrated endoscopic structured light system. In: MICCAI 2015, Springer, pp 405\u2013412, https:\/\/doi.org\/10.1007\/978-3-319-24553-9_50","DOI":"10.1007\/978-3-319-24553-9_50"},{"key":"3180_CR10","doi-asserted-by":"publisher","unstructured":"Long Z, Nagamune K (2016) Underwater 3D Imaging Using a Fiber-Based Endoscopic System for Arthroscopic Surgery. JACIII 20(3):448\u2013454. https:\/\/doi.org\/10.20965\/jaciii.2016.p0448","DOI":"10.20965\/jaciii.2016.p0448"},{"issue":"4","key":"3180_CR11","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1145\/37402.37422","volume":"21","author":"WE Lorensen","year":"1987","unstructured":"Lorensen WE, Cline HE (1987) Marching cubes: a high resolution 3D surface construction algorithm. SIGGRAPH Comput Graph 21(4):163\u2013169. https:\/\/doi.org\/10.1145\/37402.37422","journal-title":"SIGGRAPH Comput Graph"},{"key":"3180_CR12","unstructured":"Loshchilov I, Hutter F (2019) Decoupled weight decay regularization. In: International Conference on Learning Representations, https:\/\/openreview.net\/forum?id=Bkg6RiCqY7"},{"key":"3180_CR13","doi-asserted-by":"publisher","unstructured":"Miko\u0142ajczyk A, Grochowski M (2018) Data augmentation for improving deep learning in image classification problem. In: 2018 International Interdisciplinary PhD Workshop (IIPhDW), pp 117\u2013122, https:\/\/doi.org\/10.1109\/IIPHDW.2018.8388338","DOI":"10.1109\/IIPHDW.2018.8388338"},{"key":"3180_CR14","doi-asserted-by":"publisher","unstructured":"Pizer SM, Amburn EP, Austin JD, Cromartie R, Geselowitz A, Greer T, ter Haar Romeny B, Zimmerman JB, Zuiderveld K (1987) Adaptive histogram equalization and its variations. Computer Vision Graph Image Process 39(3):355\u2013368. https:\/\/doi.org\/10.1016\/S0734-189X(87)80186-X","DOI":"10.1016\/S0734-189X(87)80186-X"},{"key":"3180_CR15","doi-asserted-by":"crossref","unstructured":"Raposo C, Barreto JP (2018) 3D registration of curves and surfaces using local differential information. In: CVPR, pp 9300\u20139308","DOI":"10.1109\/CVPR.2018.00969"},{"key":"3180_CR16","first-page":"125","volume-title":"MICCAI","author":"C Raposo","year":"2018","unstructured":"Raposo C, Sousa C, Ribeiro L, Melo R, Barreto JP, Oliveira J, Marques P, Fonseca F (2018) Video-based computer aided arthroscopy for patient specific reconstruction of the anterior cruciate ligament. MICCAI. Springer-Verlag, Berlin, Heidelberg, pp 125\u2013133"},{"key":"3180_CR17","doi-asserted-by":"publisher","unstructured":"Reiter A, Sigaras A, Fowler D, Allen PK (2014) Surgical structured light for 3D minimally invasive surgical imaging. In: IROS, IEEE, pp 1282\u20131287, https:\/\/doi.org\/10.1109\/IROS.2014.6942722","DOI":"10.1109\/IROS.2014.6942722"},{"key":"3180_CR18","doi-asserted-by":"crossref","unstructured":"Ronneberger O, Fischer P, Brox T (2015) U-Net: convolutional Networks for Biomedical Image Segmentation. In: MICCAI, Springer, pp 234\u2013241","DOI":"10.1007\/978-3-319-24574-4_28"},{"issue":"5","key":"3180_CR19","doi-asserted-by":"publisher","first-page":"1063","DOI":"10.1016\/j.media.2012.04.001","volume":"16","author":"C Schmalz","year":"2012","unstructured":"Schmalz C, Forster F, Schick A, Angelopoulou E (2012) An endoscopic 3D scanner based on structured light. Med Image Anal 16(5):1063\u20131072. https:\/\/doi.org\/10.1016\/j.media.2012.04.001","journal-title":"Med Image Anal"},{"key":"3180_CR20","first-page":"1","volume":"5","author":"T Sorensen","year":"1948","unstructured":"Sorensen T (1948) A method of establishing groups of equal amplitude in plant sociology based on similarity of species content and its application to analyses of the vegetation on Danish commons. Biologiske skrifter 5:1\u201334","journal-title":"Biologiske skrifter"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-024-03180-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-024-03180-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-024-03180-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,8]],"date-time":"2024-07-08T13:17:46Z","timestamp":1720444666000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-024-03180-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,30]]},"references-count":20,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2024,7]]}},"alternative-id":["3180"],"URL":"https:\/\/doi.org\/10.1007\/s11548-024-03180-5","relation":{},"ISSN":["1861-6429"],"issn-type":[{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,5,30]]},"assertion":[{"value":"8 March 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 May 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 May 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no Conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All studies involving postmortem subjects followed the procedures for informed consent that are described in the Declaration of Helsinki.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}