{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T13:04:01Z","timestamp":1789650241768,"version":"4.0.0"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2026,3,25]],"date-time":"2026-03-25T00:00:00Z","timestamp":1774396800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,3,25]],"date-time":"2026-03-25T00:00:00Z","timestamp":1774396800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"DOI":"10.1007\/s11548-026-03594-3","type":"journal-article","created":{"date-parts":[[2026,3,25]],"date-time":"2026-03-25T07:26:50Z","timestamp":1774423610000},"page":"1835-1844","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Semi-continuous non-invasive intracranial pressure monitoring via automated optic nerve sheath diameter image acquisition and analysis: a benchtop proof-of-concept study"],"prefix":"10.1007","volume":"21","author":[{"given":"Ahmed","family":"Kashkoush","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sean","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohamed","family":"El-Abtah","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark","family":"Bain","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joao","family":"Gomes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Scott","family":"Raymond","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,3,25]]},"reference":[{"key":"3594_CR1","unstructured":"Munakomi S, Das JM (2025) Intracranial pressure monitoring. In: StatPearls. Treasure Island (FL)"},{"key":"3594_CR2","doi-asserted-by":"publisher","first-page":"e276","DOI":"10.1016\/j.wneu.2021.09.051","volume":"156","author":"AN Konovalov","year":"2021","unstructured":"Konovalov AN, Grebenev FV, Rybakov VA, Pilipenko YV, Shekhtman OD, Okishev DN, Yershova ON, Eliava SS (2021) External ventricular drainage complication risks and accuracy analysis. World Neurosurg 156:e276\u2013e282. https:\/\/doi.org\/10.1016\/j.wneu.2021.09.051","journal-title":"World Neurosurg"},{"issue":"7","key":"3594_CR3","doi-asserted-by":"publisher","first-page":"1059","DOI":"10.1007\/s00134-011-2224-2","volume":"37","author":"J Dubourg","year":"2011","unstructured":"Dubourg J, Javouhey E, Geeraerts T, Messerer M, Kassai B (2011) Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis. Intensive Care Med 37(7):1059\u20131068. https:\/\/doi.org\/10.1007\/s00134-011-2224-2","journal-title":"Intensive Care Med"},{"issue":"3","key":"3594_CR4","doi-asserted-by":"publisher","DOI":"10.1186\/cc11336","volume":"16","author":"V Rajajee","year":"2012","unstructured":"Rajajee V, Fletcher JJ, Rochlen LR, Jacobs TL (2012) Comparison of accuracy of optic nerve ultrasound for the detection of intracranial hypertension in the setting of acutely fluctuating versus stable intracranial pressure: post-hoc analysis of data from a prospective, blinded single center study. Crit Care 16(3):R79. https:\/\/doi.org\/10.1186\/cc11336","journal-title":"Crit Care"},{"key":"3594_CR5","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1016\/j.jmbbm.2016.11.001","volume":"66","author":"ST Lovald","year":"2017","unstructured":"Lovald ST, Rau A, Nissman S, Ames N, McNulty J, Ochoa JA, Baldwinson M (2017) Finite element analysis and experimental evaluation of penetrating injury through the cornea. J Mech Behav Biomed Mater 66:104\u2013110. https:\/\/doi.org\/10.1016\/j.jmbbm.2016.11.001","journal-title":"J Mech Behav Biomed Mater"},{"issue":"1","key":"3594_CR6","doi-asserted-by":"publisher","DOI":"10.1186\/s40779-020-00274-4","volume":"7","author":"HM Felix","year":"2020","unstructured":"Felix HM, Rosenbush KA, Lannen AM, Pooley RA, Siegel JL, Brown BL, McMullan ML, Collins CI, Freeman WD (2020) Creation of an optic nerve sheath diameter ultrasound model for NeuroICU education. Mil Med Res 7(1):43. https:\/\/doi.org\/10.1186\/s40779-020-00274-4","journal-title":"Mil Med Res"},{"issue":"2","key":"3594_CR7","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1017\/s0317167100013779","volume":"40","author":"FA Zeiler","year":"2013","unstructured":"Zeiler FA, Unger B, Kramer AH, Kirkpatrick AW, Gillman LM (2013) A unique model for ultrasound assessment of optic nerve sheath diameter. Can J Neurol Sci 40(2):225\u2013229. https:\/\/doi.org\/10.1017\/s0317167100013779","journal-title":"Can J Neurol Sci"},{"issue":"1","key":"3594_CR8","doi-asserted-by":"publisher","DOI":"10.1186\/s13089-023-00331-8","volume":"15","author":"BT Moore","year":"2023","unstructured":"Moore BT, Osika T, Satterly S, Shah S, Thirion T, Hampton S, Aylward S, Montgomery S (2023) Evaluation of commercially available point-of-care ultrasound for automated optic nerve sheath measurement. Ultrasound J 15(1):33. https:\/\/doi.org\/10.1186\/s13089-023-00331-8","journal-title":"Ultrasound J"},{"issue":"5","key":"3594_CR9","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1017\/s1481803500015335","volume":"9","author":"JL Kendall","year":"2007","unstructured":"Kendall JL, Faragher JP (2007) Ultrasound-guided central venous access: a homemade phantom for simulation. CJEM 9(5):371\u2013373. https:\/\/doi.org\/10.1017\/s1481803500015335","journal-title":"CJEM"},{"issue":"2","key":"3594_CR10","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1016\/j.jmu.2017.01.003","volume":"25","author":"DL Murphy","year":"2017","unstructured":"Murphy DL, Oberfoell SH, Trent SA, French AJ, Kim DJ, Richards DB (2017) Validation of a low-cost optic nerve sheath ultrasound phantom: an educational tool. J Med Ultrasound 25(2):96\u2013100. https:\/\/doi.org\/10.1016\/j.jmu.2017.01.003","journal-title":"J Med Ultrasound"},{"issue":"1","key":"3594_CR11","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1080\/02656736.2020.1739345","volume":"37","author":"LW Hofstetter","year":"2020","unstructured":"Hofstetter LW, Fausett L, Mueller A, Od\u00e9en H, Payne A, Christensen DA, Parker DL (2020) Development and characterization of a tissue mimicking psyllium husk gelatin phantom for ultrasound and magnetic resonance imaging. Int J Hyperthermia 37(1):283\u2013290. https:\/\/doi.org\/10.1080\/02656736.2020.1739345","journal-title":"Int J Hyperthermia"},{"issue":"4","key":"3594_CR12","doi-asserted-by":"publisher","first-page":"715","DOI":"10.1109\/TUFFC.2019.2953190","volume":"67","author":"J Dahmani","year":"2020","unstructured":"Dahmani J, Laporte C, Pereira D, B\u00e9langer P, Petit Y (2020) Predictive model for designing soft-tissue mimicking ultrasound phantoms with adjustable elasticity. IEEE Trans Ultrason Ferroelectr Freq Control 67(4):715\u2013726. https:\/\/doi.org\/10.1109\/TUFFC.2019.2953190","journal-title":"IEEE Trans Ultrason Ferroelectr Freq Control"},{"issue":"11","key":"3594_CR13","doi-asserted-by":"publisher","first-page":"1543","DOI":"10.1109\/TUFFC.2002.1049736","volume":"49","author":"LA Negron","year":"2002","unstructured":"Negron LA, Viola F, Black EP, Toth CA, Walker WF (2002) Development and characterization of a vitreous mimicking material for radiation force imaging. IEEE Trans Ultrason Ferroelectr Freq Control 49(11):1543\u20131551. https:\/\/doi.org\/10.1109\/TUFFC.2002.1049736","journal-title":"IEEE Trans Ultrason Ferroelectr Freq Control"},{"issue":"4","key":"3594_CR14","doi-asserted-by":"publisher","first-page":"1171","DOI":"10.1007\/s13246-020-00919-7","volume":"43","author":"D Phani","year":"2020","unstructured":"Phani D, Varadarajulu RK, Thomas A, Paramu R, Singh MS, Shaiju VS, Muraleedharan V, Nair RK (2020) Acoustic and ultrasonographic characterization of polychloroprene, beeswax, and carbomer-gel to mimic soft-tissue for diagnostic ultrasound. Phys Eng Sci Med 43(4):1171\u20131181. https:\/\/doi.org\/10.1007\/s13246-020-00919-7","journal-title":"Phys Eng Sci Med"},{"issue":"4","key":"3594_CR15","doi-asserted-by":"publisher","first-page":"1050","DOI":"10.3171\/2022.6.JNS212921","volume":"138","author":"AI Kashkoush","year":"2023","unstructured":"Kashkoush AI, Potter T, Petitt JC, Hu S, Hunter K, Kelly ML (2023) Novel application of the Rotterdam CT score in the prediction of intracranial hypertension following severe traumatic brain injury. J Neurosurg 138(4):1050\u20131057. https:\/\/doi.org\/10.3171\/2022.6.JNS212921","journal-title":"J Neurosurg"},{"issue":"1","key":"3594_CR16","doi-asserted-by":"publisher","first-page":"219","DOI":"10.1007\/s12028-022-01477-4","volume":"37","author":"FM de Moraes","year":"2022","unstructured":"de Moraes FM, Rocha E, Barros FCD, Freitas FGR, Miranda M, Valiente RA, de Andrade JBC, Neto F, Silva GS (2022) Waveform morphology as a surrogate for ICP monitoring: a comparison between an invasive and a noninvasive method. Neurocrit Care 37(1):219\u2013227. https:\/\/doi.org\/10.1007\/s12028-022-01477-4","journal-title":"Neurocrit Care"},{"issue":"3","key":"3594_CR17","doi-asserted-by":"publisher","first-page":"585","DOI":"10.1002\/jum.15732","volume":"41","author":"W Aletreby","year":"2022","unstructured":"Aletreby W, Alharthy A, Brindley PG, Kutsogiannis DJ, Faqihi F, Alzayer W, Balhahmar A, Soliman I, Hamido H, Alqahtani SA, Karakitsos D, Blaivas M (2022) Optic nerve sheath diameter ultrasound for raised intracranial pressure: a literature review and meta-analysis of its diagnostic accuracy. J Ultrasound Med 41(3):585\u2013595. https:\/\/doi.org\/10.1002\/jum.15732","journal-title":"J Ultrasound Med"},{"issue":"2","key":"3594_CR18","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1111\/j.1553-2712.2007.00031.x","volume":"15","author":"HH Kimberly","year":"2008","unstructured":"Kimberly HH, Shah S, Marill K, Noble V (2008) Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure. Acad Emerg Med 15(2):201\u2013204. https:\/\/doi.org\/10.1111\/j.1553-2712.2007.00031.x","journal-title":"Acad Emerg Med"},{"issue":"6","key":"3594_CR19","doi-asserted-by":"publisher","first-page":"898","DOI":"10.1111\/jon.13163","volume":"33","author":"MI Hirzallah","year":"2023","unstructured":"Hirzallah MI, Bose S, Hu J, Maltz JS (2023) Automation of ultrasonographic optic nerve sheath diameter measurement using convolutional neural networks. J Neuroimaging 33(6):898\u2013903. https:\/\/doi.org\/10.1111\/jon.13163","journal-title":"J Neuroimaging"},{"issue":"9","key":"3594_CR20","doi-asserted-by":"publisher","first-page":"2060","DOI":"10.1016\/j.ultrasmedbio.2023.05.011","volume":"49","author":"F Marzola","year":"2023","unstructured":"Marzola F, Lochner P, Naldi A, Lemor R, Stogbauer J, Meiburger KM (2023) Development of a deep learning-based system for optic nerve characterization in transorbital ultrasound images on a multicenter data set. Ultrasound Med Biol 49(9):2060\u20132071. https:\/\/doi.org\/10.1016\/j.ultrasmedbio.2023.05.011","journal-title":"Ultrasound Med Biol"},{"issue":"2","key":"3594_CR21","doi-asserted-by":"publisher","first-page":"200","DOI":"10.1016\/j.jemermed.2022.04.014","volume":"63","author":"RVA Hollestelle","year":"2022","unstructured":"Hollestelle RVA, Hansen D, Hoeks SE, van Meeteren NLU, Stolker RJ, Maissan IM (2022) Observer variability as a determinant of measurement error of ultrasonographic measurements of the optic nerve sheath diameter: a systematic review. J Emerg Med 63(2):200\u2013211. https:\/\/doi.org\/10.1016\/j.jemermed.2022.04.014","journal-title":"J Emerg Med"},{"issue":"1","key":"3594_CR22","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1111\/jon.12936","volume":"32","author":"J Pansell","year":"2022","unstructured":"Pansell J, Bell M, Rudberg P, Friman O, Cooray C (2022) Optic nerve sheath diameter measurement by ultrasound: evaluation of a standardized protocol. J Neuroimaging 32(1):104\u2013110. https:\/\/doi.org\/10.1111\/jon.12936","journal-title":"J Neuroimaging"},{"issue":"1","key":"3594_CR23","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1016\/j.surneu.2003.12.007","volume":"62","author":"J Bellner","year":"2004","unstructured":"Bellner J, Romner B, Reinstrup P, Kristiansson K-A, Ryding E, Brandt L (2004) Transcranial doppler sonography pulsatility index (PI) reflects intracranial pressure (ICP). Surg Neurol 62(1):45\u201351. https:\/\/doi.org\/10.1016\/j.surneu.2003.12.007","journal-title":"Surg Neurol"},{"issue":"1","key":"3594_CR24","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-023-45834-5","volume":"13","author":"FM de Moraes","year":"2023","unstructured":"de Moraes FM, Adissy ENB, Rocha E, Barros FCD, Freitas FGR, Miranda M, Valiente RA, de Andrade JBC, Chaddad-Neto FEA, Silva GS (2023) Multimodal monitoring intracranial pressure by invasive and noninvasive means. Sci Rep 13(1):18404. https:\/\/doi.org\/10.1038\/s41598-023-45834-5","journal-title":"Sci Rep"},{"issue":"1","key":"3594_CR25","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.66.1.53","volume":"66","author":"JL Demer","year":"2025","unstructured":"Demer JL, Clark RA, Suh SY, Giaconi JA, Nouri-Mahdavi K, Law SK, Bonelli L, Arnold AC, Quiros P, Coleman AL, Caprioli J (2025) Eye movements and the intraorbital subarachnoid space: potential contribution of altered cerebrospinal fluid pumping in optic neuropathies. Invest Ophthalmol Vis Sci 66(1):53. https:\/\/doi.org\/10.1167\/iovs.66.1.53","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"12","key":"3594_CR26","doi-asserted-by":"publisher","first-page":"2447","DOI":"10.1007\/s10072-019-04015-x","volume":"40","author":"P Lochner","year":"2019","unstructured":"Lochner P, Czosnyka M, Naldi A, Lyros E, Pelosi P, Mathur S, Fassbender K, Robba C (2019) Optic nerve sheath diameter: present and future perspectives for neurologists and critical care physicians. Neurol Sci 40(12):2447\u20132457. https:\/\/doi.org\/10.1007\/s10072-019-04015-x","journal-title":"Neurol Sci"},{"issue":"4","key":"3594_CR27","doi-asserted-by":"publisher","first-page":"1460","DOI":"10.4103\/0028-3886.355178","volume":"70","author":"V Suresh","year":"2022","unstructured":"Suresh V, Ushakumari PR, Aggarwal A, Kumar A, Kutty RK, Prabhakar RB, Peethambaran A (2022) Perioperative variation in optic nerve sheath diameter: a prospective observational study of traumatic brain injury patients undergoing decompressive craniectomy. Neurol India 70(4):1460\u20131467. https:\/\/doi.org\/10.4103\/0028-3886.355178","journal-title":"Neurol India"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-026-03594-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-026-03594-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-026-03594-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T12:18:33Z","timestamp":1789647513000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-026-03594-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,25]]},"references-count":27,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2026,8]]}},"alternative-id":["3594"],"URL":"https:\/\/doi.org\/10.1007\/s11548-026-03594-3","relation":{},"ISSN":["1861-6429"],"issn-type":[{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,25]]},"assertion":[{"value":"16 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 March 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 March 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors have no financial interest with regards to the authorship and\/or publication of this manuscript. A U.S. provisional patent has been filed for the systems describe herein, application number 63\/703,327.","order":1,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}}]}}