{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T08:48:26Z","timestamp":1785746906893,"version":"3.56.0"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T00:00:00Z","timestamp":1785715200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T00:00:00Z","timestamp":1785715200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>The purpose of this study is to propose a method for automatically estimating the position and angle of the acoustic window required to acquire the apical four-chamber view in echocardiography. The apical four-chamber view is clinically important, but it requires accurate probe placement near the cardiac apex. Acquisition of the apical four-chamber view is technically challenging because the acoustic window available for transthoracic ultrasound transmission is restricted by the intercostal space, and the cardiac apex and endocardial borders can be difficult to delineate due to rib shadowing and acoustic attenuation caused by the chest wall and subcutaneous tissue. Therefore, this study proposes a method for automatically acquiring cross sectional images without directly detecting the apex.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>The proposed method estimates the apical four-chamber view through a three-step procedure. First, starting from the parasternal long-axis view, the probe is swept obliquely along the body surface while maintaining the mitral valve near the center of the ultrasound image and gradually rotating the probe toward the apical region. This maneuver is continued through the acoustic window where the cardiac apex can be visualized until the mitral valve leaflets are no longer visible. Second, the probe is rotated and angled to visualize the tricuspid valve, mitral valve, and interventricular septum in a single imaging plane. Finally, the probe is tilted and rocked to optimize the apical four-chamber view.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Proof-of-concept experiments demonstrated that the proposed framework could estimate probe positions and orientations for acquiring apical four-chamber views without direct apex detection. Across five subjects, the system achieved an image quality score of 68.0%\u2009\u00b1\u20097.6% based on predefined scoring criteria. These preliminary findings suggest the potential feasibility of algorithm-assisted guidance for apical view acquisition in echocardiography.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>This study presented a three-step method to estimate the acoustic window for apical four-chamber acquisition without direct apex detection. A proof-of-concept evaluation in five subjects demonstrated that the proposed method could estimate the target acoustic window and suggested the potential of algorithm-assisted guidance for apical four-chamber view acquisition.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s11548-026-03766-1","type":"journal-article","created":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T08:32:41Z","timestamp":1785745961000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Automated image acquisition of apical four-chamber view with robotic echocardiography"],"prefix":"10.1007","author":[{"given":"Yuuki","family":"Shida","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ningzhi","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuki","family":"Yamauchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Souto","family":"Kumagai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroyasu","family":"Iwata","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,8,3]]},"reference":[{"key":"3766_CR1","unstructured":"WHO (World Health Organization) (2024) The top 10 causes of death"},{"key":"3766_CR2","unstructured":"Ministry of Health, Labour and Welfare (2020) Trends in death rates for leading causes of death"},{"issue":"7","key":"3766_CR3","doi-asserted-by":"publisher","first-page":"634","DOI":"10.7210\/jrsj.29.634","volume":"29","author":"Y Takachi","year":"2011","unstructured":"Takachi Y, Masuda K, Yoshinaga T, Aoki Y (2011) Development of a support system for handling ultrasound probe to alleviate fatigue of physician by introducing a coordinated motion with robot. J Robot Soc Jpn 29(7):634\u2013642","journal-title":"J Robot Soc Jpn"},{"key":"3766_CR4","doi-asserted-by":"crossref","unstructured":"Nakadate R, Solis J, Takanishi A, Minagawa E, Sugawara M, Niki K (2011) Out-of-plane visual servoing method for tracking the carotid artery with a robot-assisted ultrasound diagnostic system. Proc IEEE Int Conf Robot Automat, pp 5267\u20135272","DOI":"10.1109\/ICRA.2011.5979594"},{"issue":"2","key":"3766_CR5","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1007\/s11548-022-02759-0","volume":"18","author":"J Zhou","year":"2023","unstructured":"Zhou J, Koizumi N, Nishiyama Y, Kogiso K, Ishikawa T, Kobayashi K, Watanabe Y, Fujibayashi T, Yamada M, Matsuyama M, Tsukihara H, Tsumura R, Yoshinaka K, Matsumoto N, Ogawa M, Miyazaki H, Numata K, Nagaoka H, Iwai T, Iijima H (2023) A VS ultrasound diagnostic system with kidney image evaluation functions. Int J Comput Assist Radiol Surg 18(2):227\u2013246","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"3","key":"3766_CR6","doi-asserted-by":"publisher","first-page":"4664","DOI":"10.1109\/LRA.2021.3068702","volume":"6","author":"R Tsumura","year":"2021","unstructured":"Tsumura R, Hardin JW, Bimbraw K, Grossestreuer AV, Odusanya OS, Zheng Y, Hill JC, Hoffmann B, Soboyejo W, Zhang HK (2021) Tele-operative low-cost robotic lung ultrasound scanning platform for triage of COVID-19 patients. IEEE Robot Automat Lett 6(3):4664\u20134671","journal-title":"IEEE Robot Automat Lett"},{"issue":"8","key":"3766_CR7","doi-asserted-by":"publisher","first-page":"1323","DOI":"10.1007\/s11548-020-02130-1","volume":"15","author":"R Tsumura","year":"2020","unstructured":"Tsumura R, Iwata H (2020) Robotic fetal ultrasonography platform with a passive scan mechanism. Int J Comput Assist Radiol Surg 15(8):1323\u20131333","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"3766_CR8","doi-asserted-by":"crossref","unstructured":"Shida Y, Tsumura R, Watanabe T, Iwata H (2021) Heart position estimation based on bone distribution toward autonomous robotic fetal ultrasonography. Proc IEEE Int Conf Robot Automat, pp 11393\u201311399","DOI":"10.1109\/ICRA48506.2021.9560839"},{"issue":"3","key":"3766_CR9","doi-asserted-by":"publisher","first-page":"649","DOI":"10.1007\/s12553-019-00399-0","volume":"10","author":"M Giuliani","year":"2020","unstructured":"Giuliani M, Szcz\u0119\u015bniak-Sta\u0144czyk D, Mirnig N, Stollnberger G, Szyszko M, Sta\u0144czyk B, Tscheligi M (2020) User-centred design and evaluation of a tele-operated echocardiography robot. Health Technol 10(3):649\u2013665","journal-title":"Health Technol"},{"issue":"8","key":"3766_CR10","doi-asserted-by":"publisher","first-page":"5228","DOI":"10.1109\/LRA.2023.3292568","volume":"8","author":"Y Shida","year":"2023","unstructured":"Shida Y, Kumagai S, Tsumura R, Iwata H (2023) Automated image acquisition of parasternal long-axis view with robotic echocardiography. IEEE Robot Automat Lett 8(8):5228\u20135235","journal-title":"IEEE Robot Automat Lett"},{"key":"3766_CR11","doi-asserted-by":"crossref","unstructured":"Yamauchi Y, Shida Y, Kumagai S, Iwata H (2024) Identification and Avoidance of Multiple Reflections and Posterior Echo Enhancement using Robotic Echocardiography. In: 2024 IEEE International Conference on Advanced Intelligent Mechatronics (AIM), Boston, MA, USA, pp 404\u2013409","DOI":"10.1109\/AIM55361.2024.10636943"},{"key":"3766_CR12","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1007\/s11548-024-03275-z","volume":"20","author":"Y Shida","year":"2025","unstructured":"Shida Y, Kumagai S, Iwata H (2025) Robotic navigation with deep reinforcement learning in transthoracic echocardiography. Int J Comput Assist Radiol Surg 20:191\u2013202","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"3766_CR13","unstructured":"JSS (Japan Society of Ultrasonics in Medicine) (2024) https:\/\/www.jss.org\/e-learning\/scanning\/circulatory_b.html. Accessed 13 Feb 2026"},{"issue":"4","key":"3766_CR14","doi-asserted-by":"publisher","first-page":"044503","DOI":"10.1117\/1.JMI.5.4.044503","volume":"5","author":"P Zhu","year":"2018","unstructured":"Zhu P, Li Z (2018) Guideline-based learning for standard plane extraction in 3-D echocardiography. J Med Imaging 5(4):044503","journal-title":"J Med Imaging"},{"issue":"6","key":"3766_CR15","doi-asserted-by":"publisher","first-page":"1221","DOI":"10.1109\/TMI.2017.2690836","volume":"36","author":"AH Abdi","year":"2017","unstructured":"Abdi AH, Luong C, Tsang T, Allan G, Nouranian S, Jue J, Hawley D, Fleming S, Gin K, Swift J, Rohling R, Abolmaesumi P (2017) Automatic quality assessment of echocardiograms using convolutional neural networks: feasibility on the apical four-chamber view. IEEE Trans Med Imaging 36(6):1221\u20131230","journal-title":"IEEE Trans Med Imaging"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-026-03766-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-026-03766-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-026-03766-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T08:32:43Z","timestamp":1785745963000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-026-03766-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,3]]},"references-count":15,"alternative-id":["3766"],"URL":"https:\/\/doi.org\/10.1007\/s11548-026-03766-1","relation":{},"ISSN":["1861-6429"],"issn-type":[{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,3]]},"assertion":[{"value":"13 February 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 July 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 August 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare that they have no conflicts of interest.","order":1,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All procedures performed in studies involving human participants were conducted in accordance with the ethical standards of the institutional research committee in Waseda University.This study was approved by the Ethics Committee of Waseda University under the following approval numbers: 2022\u2013040 (Acquisition and evaluation of echocardiographic images under various body postures using a seated robotic echocardiography system), 2022\u2013532 (Evaluation of the relationship between probe contact force and image clarity in echocardiography), 2024\u2013111 (Acquisition and evaluation of echocardiographic images through physician motion imitation using a seated robotic echocardiography system).","order":2,"name":"Ethics","label":"Ethical approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Informed consent was obtained from all subjects included in the study.","order":3,"name":"Ethics","label":"Informed consent","group":{"name":"EthicsHeading","label":"Declarations"}}]}}