{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T01:42:25Z","timestamp":1792806145525,"version":"4.5.0"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T00:00:00Z","timestamp":1792800000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T00:00:00Z","timestamp":1792800000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["23K17236"],"award-info":[{"award-number":["23K17236"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["20H04552"],"award-info":[{"award-number":["20H04552"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"DOI":"10.1007\/s11548-026-03808-8","type":"journal-article","created":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T00:56:21Z","timestamp":1792803381000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Investigation of gear design parameters for soft-gear-driven self-propelled colonoscopy robot"],"prefix":"10.1007","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1946-0763","authenticated-orcid":false,"given":"Keisuke","family":"Osawa","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kaiwen","family":"Duan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akio","family":"Ueda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryu","family":"Nakadate","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jumpei","family":"Arata","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshihiro","family":"Nagao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomohiko","family":"Akahoshi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masatoshi","family":"Eto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eiichiro","family":"Tanaka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,10,24]]},"reference":[{"issue":"1","key":"3808_CR1","first-page":"17","volume":"74","author":"RL Siegel","year":"2024","unstructured":"Siegel RL, Miller KD, Fuchs HE, Jemal A (2024) Cancer statistics, 2024. CA Cancer J Clin 74(1):17\u201348","journal-title":"CA Cancer J Clin"},{"issue":"6785","key":"3808_CR2","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1038\/35013140","volume":"405","author":"G Iddan","year":"2000","unstructured":"Iddan G, Meron G, Glukhovsky A, Swain P (2000) Wireless capsule endoscopy. Nature 405(6785):417","journal-title":"Nature"},{"issue":"1","key":"3808_CR3","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1016\/j.bpg.2005.09.004","volume":"20","author":"H Kita","year":"2006","unstructured":"Kita H, Yamamoto H (2006) Double-balloon endoscopy for the diagnosis and treatment of small intestinal disease. Best Pract Res Clin Gastroenterol 20(1):179\u2013194","journal-title":"Best Pract Res Clin Gastroenterol"},{"key":"3808_CR4","doi-asserted-by":"publisher","first-page":"595","DOI":"10.1038\/s42256-020-00231-9","volume":"2","author":"JW Martin","year":"2020","unstructured":"Martin JW, Scaglioni B, Norton JC, Subramanian V, Arezzo A, Obstein KL, Valdastri P (2020) Enabling the future of colonoscopy with intelligent and autonomous magnetic manipulation. Nat Mach Intell 2:595\u2013606","journal-title":"Nat Mach Intell"},{"issue":"2","key":"3808_CR5","doi-asserted-by":"publisher","first-page":"989","DOI":"10.1007\/s00464-020-08089-z","volume":"35","author":"SA Coleman","year":"2020","unstructured":"Coleman SA, Pakleppa M, Cuschieri A (2020) Hydro-jet propelled colonoscopy: proof of concept in a phantom colon. Surg Endosc 35(2):989\u2013995","journal-title":"Surg Endosc"},{"issue":"3","key":"3808_CR6","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1080\/03091902.2016.1275853","volume":"41","author":"H Dehghani","year":"2017","unstructured":"Dehghani H, Welch CR, Pourghodrat A, Nelson CA, Oleynikov D, Dasgupta P, Terry BS (2017) Design and preliminary evaluation of a self-steering pneumatically driven colonoscopy robot. J Med Eng Technol 41(3):223\u2013236","journal-title":"J Med Eng Technol"},{"issue":"3","key":"3808_CR7","doi-asserted-by":"publisher","first-page":"1718","DOI":"10.1109\/LRA.2017.2678540","volume":"2","author":"JE Bernth","year":"2017","unstructured":"Bernth JE, Arezzo A, Liu H (2017) A novel robotic meshworm with segment-bending anchoring for colonoscopy. IEEE Robot Autom Lett 2(3):1718\u20131724","journal-title":"IEEE Robot Autom Lett"},{"issue":"4","key":"3808_CR8","doi-asserted-by":"publisher","first-page":"6710","DOI":"10.1109\/LRA.2020.3017476","volume":"5","author":"K Osawa","year":"2020","unstructured":"Osawa K, Nakadate R, Arata J, Nagao Y, Akahoshi T, Eto M, Hashizume M (2020) Self-propelled colonoscopy robot using flexible paddles. IEEE Robot Autom Lett 5(4):6710\u20136716","journal-title":"IEEE Robot Autom Lett"},{"key":"3808_CR9","doi-asserted-by":"crossref","unstructured":"Chen Y, Liang, J, Hunter IW (2014) Modular continuum robotic endoscope design and path planning. In: Proceedings of 2014 IEEE international conference on robotics and automation, pp 5393\u20135400","DOI":"10.1109\/ICRA.2014.6907652"},{"key":"3808_CR10","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1007\/s11548-010-0481-0","volume":"5","author":"G Trovato","year":"2010","unstructured":"Trovato G, Shikanai M, Ukawa G, Kinoshita J, Murai N, Lee JW, Ishii H, Takanishi A, Tanoue K, Ieiri S, Konishi K, Hashizume M (2010) Development of a colon endoscope robot that adjusts its locomotion through the use of reinforcement learning. Int J Comput Assist Radiol Surg 5:317\u2013325","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"3808_CR11","doi-asserted-by":"crossref","unstructured":"Norton J, Hood A, Neville A, Jayne D, Culmer P (2016) RollerBall: a mobile robot for intraluminal locomotion. In: Proceedings of 2016 6th IEEE international conference on biomedical robotics and biomechatronics, pp 254\u2013259","DOI":"10.1109\/BIOROB.2016.7523634"},{"key":"3808_CR12","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1016\/j.mechatronics.2016.08.002","volume":"39","author":"D Lee","year":"2016","unstructured":"Lee D, Joe S, Choi J, Lee BI, Kim B (2016) An elastic caterpillar-based self-propelled robotic colonoscope with high safety and mobility. Mechatronics 39:54\u201362","journal-title":"Mechatronics"},{"issue":"1","key":"3808_CR13","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1109\/TMRB.2019.2895800","volume":"1","author":"J Nagase","year":"2019","unstructured":"Nagase J, Fukunaga F, Ogawa K, Saga N (2019) Funicular flexible crawler for colonoscopy. IEEE Trans Med Robot Bionics 1(1):22\u201329","journal-title":"IEEE Trans Med Robot Bionics"},{"issue":"2","key":"3808_CR14","doi-asserted-by":"publisher","first-page":"545","DOI":"10.1109\/TRO.2019.2949466","volume":"36","author":"G Formosa","year":"2019","unstructured":"Formosa G, Prendergast JM, Edmundowicz SA, Rentschler M (2019) Novel optimization-based design and surgical evaluation of a treaded robotic capsule colonoscope. IEEE Trans Robot 36(2):545\u2013552","journal-title":"IEEE Trans Robot"},{"issue":"3","key":"3808_CR15","doi-asserted-by":"publisher","first-page":"1659","DOI":"10.1109\/LRA.2023.3241811","volume":"8","author":"V Consumi","year":"2023","unstructured":"Consumi V, Lindenroth L, Merlin J, Stoyanov D, Stilli A (2023) Design and evaluation of the SoftSCREEN capsule for colonoscopy. IEEE Robot Autom Lett 8(3):1659\u20131666","journal-title":"IEEE Robot Autom Lett"},{"key":"3808_CR16","doi-asserted-by":"crossref","unstructured":"He S, Zhang Y, Huang B, Lin J, Shi C, Hu C (2024) A track-based colon endoscopic robot with depth perception stereo cameras for haustral fold detection during colonic navigation. In: Proceedings of 2024 IEEE international conference on robotics and automation, pp 1276\u20131282","DOI":"10.1109\/ICRA57147.2024.10611617"},{"key":"3808_CR17","doi-asserted-by":"publisher","DOI":"10.3389\/frobt.2025.1580692","volume":"12","author":"J Du","year":"2025","unstructured":"Du J, Cao L, Dogramadzi S (2025) Design and preliminary evaluation of a track-based robotic colonoscope with a shape-adaptable tip for propulsion. Front Robot AI 12:1580692","journal-title":"Front Robot AI"},{"key":"3808_CR18","unstructured":"Osawa K, Nakadate R, Arata J, Akahoshi T, Masatoshi E, Hashizume M (2019) Self-propelled colonoscope robot by elastic wall fitting mechanism. In: Proceedings of the 15th Asian conference on computer aided surgery"},{"key":"3808_CR19","doi-asserted-by":"crossref","unstructured":"Osawa K, Nakadate R, Arata J, Nagao Y, Akahoshi T, Masatoshi E, Hashizume M (2026) Self-propelled colonoscopy robot with an elastic wall-fitting mechanism. In: Advanced biomedical engineering","DOI":"10.14326\/abe.250405"},{"issue":"4","key":"3808_CR20","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1080\/13645706.2025.2467805","volume":"34","author":"D Shah","year":"2025","unstructured":"Shah D, Tesfai FM, Boal M, Arezzo A, Francis N (2025) Evaluation of current and emerging endoluminal robotic platforms using the IDEAL framework. Minim Invasive Ther Allied Technol 34(4):253\u2013266","journal-title":"Minim Invasive Ther Allied Technol"},{"issue":"2","key":"3808_CR21","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1007\/s11249-006-9073-0","volume":"22","author":"JS Kim","year":"2006","unstructured":"Kim JS, Sung IH, Kim YT, Kwon EY, Kim DE, Jang YH (2006) Experimental investigation of frictional and viscoelastic properties of intestine for microendoscope application. Tribol Lett 22(2):143\u2013149","journal-title":"Tribol Lett"},{"key":"3808_CR22","doi-asserted-by":"publisher","first-page":"3155","DOI":"10.1007\/s11071-019-05061-y","volume":"98","author":"B Guo","year":"2019","unstructured":"Guo B, Liu Y, Prasad S (2019) Modeling of capsule-intestine contact for a self-propelled capsule robot via experimental and numerical investigation. Nonlinear Dyn 98:3155\u20133167","journal-title":"Nonlinear Dyn"},{"issue":"3","key":"3808_CR23","doi-asserted-by":"publisher","first-page":"918","DOI":"10.1109\/TRO.2020.3038709","volume":"37","author":"JM Prendergast","year":"2021","unstructured":"Prendergast JM, Formosa GA, Fulton MJ, Heckman CR, Rentschler ME (2021) A real-time state dependent region estimator for autonoumous endoscope navigation. IEEE Trans Robot 37(3):918\u2013934","journal-title":"IEEE Trans Robot"},{"issue":"6","key":"3808_CR24","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1080\/13645706.2025.2540482","volume":"34","author":"PA Boland","year":"2025","unstructured":"Boland PA, McEntee PD, Cucek J, Erzen S, Niemiec E, Galligan M, Petropoulou T, Burke JB, Knol J, Hompes R, Tuynman J, Aigner F, Arezzo A, Cahill RA (2025) Protocol for CLASSICA software as medical device trial. Minim Invasive Ther Allied Technol 34(6):441\u2013446","journal-title":"Minim Invasive Ther Allied Technol"},{"issue":"1","key":"3808_CR25","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1080\/13645706.2024.2335540","volume":"34","author":"S Kwon","year":"2025","unstructured":"Kwon S, Adin V, Park C, Chun H, Kim K, Kim C (2025) Camera sheath with transformable head for minimally invasive surgical instruments. Minim Invasive Ther Allied Technol 34(1):44\u201352","journal-title":"Minim Invasive Ther Allied Technol"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-026-03808-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-026-03808-8","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-026-03808-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T00:56:22Z","timestamp":1792803382000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-026-03808-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,24]]},"references-count":25,"alternative-id":["3808"],"URL":"https:\/\/doi.org\/10.1007\/s11548-026-03808-8","relation":{},"ISSN":["1861-6429"],"issn-type":[{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,24]]},"assertion":[{"value":"30 March 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 October 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 October 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}