{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,8]],"date-time":"2025-11-08T22:15:40Z","timestamp":1762640140340},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2023,5,5]],"date-time":"2023-05-05T00:00:00Z","timestamp":1683244800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,5,5]],"date-time":"2023-05-05T00:00:00Z","timestamp":1683244800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["CURR MED SCI"],"published-print":{"date-parts":[[2023,6]]},"DOI":"10.1007\/s11596-023-2717-6","type":"journal-article","created":{"date-parts":[[2023,5,5]],"date-time":"2023-05-05T03:27:53Z","timestamp":1683257273000},"page":"572-578","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Comprehensive Treatment Uncertainty Analysis and PTV Margin Estimation for Fiducial Tracking in Robotic Liver Stereotactic Body Radiation Therapy"],"prefix":"10.1007","volume":"43","author":[{"given":"Zhi-wen","family":"Liang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Meng-lan","family":"Zhai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Biao","family":"Tu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xin","family":"Nie","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiao-hui","family":"Zhu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jun-ping","family":"Cheng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guo-quan","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dan-dan","family":"Yu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tao","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sheng","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,5,5]]},"reference":[{"key":"2717_CR1","unstructured":"Latest global cancer data: Cancer burden rises to 19.3 million new cases and 10.0 million cancer deaths in 2020. IARC, 2020"},{"key":"2717_CR2","doi-asserted-by":"publisher","first-page":"309780","DOI":"10.1155\/2010\/309780","volume":"2010","author":"K Goyal","year":"2010","unstructured":"Goyal K, Einstein D, Yao M, et al. Cyberknife stereotactic body radiation therapy for nonresectable tumors of the liver: preliminary results. HPB Surg, 2010,2010:309780","journal-title":"HPB Surg"},{"issue":"4","key":"2717_CR3","doi-asserted-by":"publisher","first-page":"325","DOI":"10.1007\/s00066-019-01524-8","volume":"196","author":"E Clerici","year":"2020","unstructured":"Clerici E, Comito T, Franzese C, et al. Role of stereotactic body radiation therapy in the treatment of liver metastases: clinical results and prognostic factors. Strahlenther Onkol, 2020,196(4):325\u2013333","journal-title":"Strahlenther Onkol"},{"issue":"12","key":"2717_CR4","doi-asserted-by":"publisher","first-page":"1706","DOI":"10.1080\/0284186X.2019.1657942","volume":"58","author":"M Dobrzycka","year":"2019","unstructured":"Dobrzycka M, Spychalski P, Rostkowska O, et al. Stereotactic body radiation therapy for early-stage hepatocellular carcinoma - a systematic review on outcome. Acta Oncol, 2019,58(12):1706\u20131713","journal-title":"Acta Oncol"},{"issue":"3","key":"2717_CR5","doi-asserted-by":"publisher","first-page":"240","DOI":"10.1016\/j.semradonc.2017.02.004","volume":"27","author":"KA Goodman","year":"2017","unstructured":"Goodman KA, Kavanagh BD. Stereotactic Body Radiotherapy for Liver Metastases. Semin Radiat Oncol, 2017,27(3):240\u2013246","journal-title":"Semin Radiat Oncol"},{"issue":"3","key":"2717_CR6","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1002\/acm2.12292","volume":"19","author":"Z Liang","year":"2018","unstructured":"Liang Z, Liu H, Xue J, et al. Evaluation of the intra- and interfractional tumor motion and variability by fiducial-based real-time tracking in liver stereotactic body radiation therapy. J Appl Clin Med Phys, 2018,19(3):94\u2013100","journal-title":"J Appl Clin Med Phys"},{"issue":"5","key":"2717_CR7","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1177\/153303461000900502","volume":"9","author":"W Kilby","year":"2010","unstructured":"Kilby W, Dooley JR, Kuduvalli G, et al. The CyberKnife Robotic Radiosurgery System in 2010. Technol Cancer Res Treat, 2010,9(5):433\u2013452","journal-title":"Technol Cancer Res Treat"},{"issue":"1","key":"2717_CR8","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1186\/s13014-020-1457-z","volume":"15","author":"J Sun","year":"2020","unstructured":"Sun J, Ouyang C, Chang XY, et al. Repeated CyberKnife stereotactic body radiation therapy in hepatocellular carcinoma. Radiat Oncol, 2020,15(1):10","journal-title":"Radiat Oncol"},{"key":"2717_CR9","doi-asserted-by":"publisher","first-page":"915","DOI":"10.2147\/OTT.S58409","volume":"7","author":"ZY Yuan","year":"2014","unstructured":"Yuan ZY, Meng MB, Liu CL, et al. Stereotactic body radiation therapy using the CyberKnife\u00ae system for patients with liver metastases. Oncotargets Ther, 2014,7:915\u2013923","journal-title":"Oncotargets Ther"},{"key":"2717_CR10","doi-asserted-by":"publisher","first-page":"100","DOI":"10.3389\/fonc.2020.00100","volume":"10","author":"J Sun","year":"2020","unstructured":"Sun J, Zhang AM, Li WG, et al. CyberKnife Stereotactic Body Radiation Therapy as an Effective Treatment for Hepatocellular Carcinoma Patients With Decompensated Cirrhosis. Front Oncol, 2020,10:100","journal-title":"Front Oncol"},{"issue":"8","key":"2717_CR11","first-page":"3381","volume":"29","author":"G Ambrosino","year":"2009","unstructured":"Ambrosino G, Polistina F, Costantin G, et al. Image-guided Robotic Stereotactic Radiosurgery for Unresectable Liver Metastases: Preliminary Results. Anticancer Res, 2009,29(8):3381\u20133384","journal-title":"Anticancer Res"},{"issue":"2","key":"2717_CR12","doi-asserted-by":"publisher","first-page":"486","DOI":"10.1016\/j.ijrobp.2009.08.020","volume":"78","author":"KA Goodman","year":"2010","unstructured":"Goodman KA, Wiegner EA, Maturen KE, et al. Dose-escalation study of single-fraction stereotactic body radiotherapy for liver malignancies. Int J Radiat Oncol Biol Phys, 2010,78(2):486\u2013493","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"6","key":"2717_CR13","doi-asserted-by":"publisher","first-page":"1026","DOI":"10.1016\/j.ejca.2010.01.008","volume":"46","author":"S Stintzing","year":"2010","unstructured":"Stintzing S, Hoffmann RT, Heinemann V, et al. Frameless single-session robotic radiosurgery of liver metastases in colorectal cancer patients. Eur J Cancer, 2010,46(6):1026\u20131032","journal-title":"Eur J Cancer"},{"issue":"3","key":"2717_CR14","doi-asserted-by":"publisher","first-page":"e39","DOI":"10.1016\/j.ijrobp.2010.12.047","volume":"81","author":"C Vautravers-Dewas","year":"2011","unstructured":"Vautravers-Dewas C, Dewas S, Bonodeau F, et al. Image-guided robotic stereotactic body radiation therapy for liver metastases: is there a dose response relationship? Int J Radiat Oncol Biol Phys, 2011,81(3):e39\u201347","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"7","key":"2717_CR15","doi-asserted-by":"publisher","first-page":"4036","DOI":"10.1118\/1.3596527","volume":"38","author":"EW Pepin","year":"2011","unstructured":"Pepin EW, Wu H, Zhang Y, et al. Correlation and prediction uncertainties in the cyberknife synchrony respiratory tracking system. Med Phys, 2011,38(7):4036\u20134044","journal-title":"Med Phys"},{"issue":"1","key":"2717_CR16","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1186\/s13014-017-0889-6","volume":"12","author":"X Zhen","year":"2017","unstructured":"Zhen X, Zhao B, Wang Z, et al. Comprehensive target geometric errors and margin assessment in stereotactic partial breast irradiation. Radiat Oncol, 2017,12(1):151","journal-title":"Radiat Oncol"},{"issue":"4","key":"2717_CR17","doi-asserted-by":"publisher","first-page":"916","DOI":"10.1016\/j.ijrobp.2015.08.031","volume":"93","author":"JD Winter","year":"2015","unstructured":"Winter JD, Wong R, Swaminath A, et al. Accuracy of Robotic Radiosurgical Liver Treatment Throughout the Respiratory Cycle. Int J Radiat Oncol Biol Phys, 2015,93(4):916\u2013924","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"6","key":"2717_CR18","doi-asserted-by":"publisher","first-page":"906","DOI":"10.1080\/0284186X.2019.1578896","volume":"58","author":"M Liu","year":"2019","unstructured":"Liu M, Cygler JE, Vandervoort E. Geometrical tracking accuracy and appropriate PTV margins for robotic radiosurgery of liver lesions by SBRT. Acta Oncol, 2019,58(6):906\u2013915","journal-title":"Acta Oncol"},{"key":"2717_CR19","doi-asserted-by":"crossref","unstructured":"Hasse K, Han F, Neylon J, et al. Estimation and validation of patient-specific liver elasticity distributions derived from 4DMR for radiotherapy purposes. Biomed Phys Eng Expr, 2018,4(4)","DOI":"10.1088\/2057-1976\/aace4d"},{"issue":"1","key":"2717_CR20","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1016\/j.radonc.2016.07.023","volume":"121","author":"ES Worm","year":"2016","unstructured":"Worm ES, Bertholet J, Hoyer M, et al. Fiducial marker guided stereotactic liver radiotherapy: Is a time delay between marker implantation and planning CT needed? Radiother Oncol, 2016,121(1):75\u201378","journal-title":"Radiother Oncol"},{"issue":"3","key":"2717_CR21","doi-asserted-by":"publisher","first-page":"253","DOI":"10.7785\/tcrt.2012.500378","volume":"13","author":"K Valentine","year":"2014","unstructured":"Valentine K, Cabrera T, Roberge D. Implanting metal fiducials to guide stereotactic liver radiation: McGill experience and review of current devices, techniques and complications. Technol Cancer Res Treat, 2014,13(3):253\u2013258","journal-title":"Technol Cancer Res Treat"},{"issue":"2","key":"2717_CR22","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1016\/j.meddos.2008.02.004","volume":"33","author":"C Ozhasoglu","year":"2008","unstructured":"Ozhasoglu C, Saw CB, Chen H, et al. Synchrony-cyberknife respiratory compensation technology. Med Dosim, 2008,33(2):117\u2013123","journal-title":"Med Dosim"},{"issue":"6","key":"2717_CR23","doi-asserted-by":"publisher","first-page":"776","DOI":"10.1177\/1533034616687193","volume":"16","author":"AK Paulsson","year":"2017","unstructured":"Paulsson AK, Yom SS, Anwar M, et al. Respiration-Induced Intraorgan Deformation of the Liver: Implications for Treatment Planning in Patients Treated With Fiducial Tracking. Technol Cancer Res Treat, 2017,16(6):776\u2013782","journal-title":"Technol Cancer Res Treat"},{"issue":"11","key":"2717_CR24","doi-asserted-by":"publisher","first-page":"5482","DOI":"10.1002\/mp.14501","volume":"47","author":"Z Liang","year":"2020","unstructured":"Liang Z, Zhou Q, Yang J, et al. Artificial intelligence-based framework in evaluating intrafraction motion for liver cancer robotic stereotactic body radiation therapy with fiducial tracking. Med Phys, 2020,47(11):5482\u20135489","journal-title":"Med Phys"},{"issue":"2","key":"2717_CR25","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1002\/acm2.12263","volume":"19","author":"E Vandervoort","year":"2018","unstructured":"Vandervoort E, Patrocinio H, Chow T, et al. COMP Report: CPQR technical quality control guidelines for CyberKnife\u00ae Technology. J Appl Clin Med Phys, 2018,19(2):29\u201334","journal-title":"J Appl Clin Med Phys"},{"issue":"6","key":"2717_CR26","doi-asserted-by":"publisher","first-page":"4825","DOI":"10.1120\/jacmp.v15i6.4825","volume":"15","author":"A Floriano","year":"2014","unstructured":"Floriano A, Garc\u00e3a R, Moreno R, et al. Retrospective evaluation of CTV to PTV margins using CyberKnife in patients with thoracic tumors. J Appl Clin Med Phys, 2014,15(6):4825","journal-title":"J Appl Clin Med Phys"},{"issue":"5","key":"2717_CR27","doi-asserted-by":"publisher","first-page":"1588","DOI":"10.1016\/j.ijrobp.2020.11.036","volume":"109","author":"J Zhang","year":"2021","unstructured":"Zhang J, Wang L, Li X, et al. Quantification of Intrafraction and Interfraction Tumor Motion Amplitude and Prediction Error for Different Liver Tumor Trajectories in Cyberknife Synchrony Tracking. Int J Radiat Oncol Biol Phys, 2021,109(5):1588\u20131605","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"4","key":"2717_CR28","doi-asserted-by":"publisher","first-page":"839","DOI":"10.1016\/j.ijrobp.2016.11.041","volume":"97","author":"M Chan","year":"2017","unstructured":"Chan M, Grehn M, Cremers F, et al. Dosimetric Implications of Residual Tracking Errors During Robotic SBRT of Liver Metastases. Int J Radiat Oncol Biol Phys, 2017,97(4):839\u2013848","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"1","key":"2717_CR29","doi-asserted-by":"publisher","first-page":"282","DOI":"10.1118\/1.3271684","volume":"37","author":"F Ernst","year":"2010","unstructured":"Ernst F, Schlaefer A, Schweikard A. Smoothing of respiratory motion traces for motion-compensated radiotherapy. Med Phys, 2010,37(1):282\u2013294","journal-title":"Med Phys"},{"issue":"4","key":"2717_CR30","doi-asserted-by":"publisher","first-page":"383","DOI":"10.1016\/j.rpor.2019.06.001","volume":"24","author":"M Nakayama","year":"2019","unstructured":"Nakayama M, Uehara K, Nishimura H, et al. Retrospective assessment of a single fiducial marker tracking regimen with robotic stereotactic body radiation therapy for liver tumors. Rep Pract Oncol Radiother, 2019,24(4):383\u2013391","journal-title":"Rep Pract Oncol Radiother"},{"issue":"10","key":"2717_CR31","doi-asserted-by":"publisher","first-page":"5172","DOI":"10.1002\/mp.14419","volume":"47","author":"M Liu","year":"2020","unstructured":"Liu M, Cygler JE, Vandervoort E. Patient-specific PTV margins for liver stereotactic body radiation therapy determined using support vector classification with an early warning system for margin adaptation. Med Phys, 2020,47(10):5172\u20135182","journal-title":"Med Phys"},{"issue":"12","key":"2717_CR32","doi-asserted-by":"publisher","first-page":"1786","DOI":"10.1080\/0284186X.2019.1648862","volume":"58","author":"Z Liang","year":"2019","unstructured":"Liang Z, Yang J, Liu H, et al. Real-time tumor motion monitoring and PTV margin determination in lung SBRT treatment. Acta Oncol, 2019,58(12):1786\u20131789","journal-title":"Acta Oncol"}],"container-title":["Current Medical Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11596-023-2717-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11596-023-2717-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11596-023-2717-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,5]],"date-time":"2023-07-05T13:22:50Z","timestamp":1688563370000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11596-023-2717-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5,5]]},"references-count":32,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2023,6]]}},"alternative-id":["2717"],"URL":"https:\/\/doi.org\/10.1007\/s11596-023-2717-6","relation":{},"ISSN":["2096-5230","2523-899X"],"issn-type":[{"value":"2096-5230","type":"print"},{"value":"2523-899X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,5,5]]},"assertion":[{"value":"2 November 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 February 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 May 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}