{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,12]],"date-time":"2026-08-12T13:09:39Z","timestamp":1786540179687,"version":"build-2736575974"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2019,12,13]],"date-time":"2019-12-13T00:00:00Z","timestamp":1576195200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,12,13]],"date-time":"2019-12-13T00:00:00Z","timestamp":1576195200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Jpn J Radiol"],"published-print":{"date-parts":[[2020,3]]},"DOI":"10.1007\/s11604-019-00911-6","type":"journal-article","created":{"date-parts":[[2019,12,13]],"date-time":"2019-12-13T12:02:38Z","timestamp":1576238558000},"page":"256-264","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Comparison of rigid and deformable image registration for nasopharyngeal carcinoma radiotherapy planning with diagnostic position PET\/CT"],"prefix":"10.1007","volume":"38","author":[{"given":"Yudai","family":"Kai","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hidetaka","family":"Arimura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9764-5718","authenticated-orcid":false,"given":"Ryo","family":"Toya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tetsuo","family":"Saito","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomohiko","family":"Matsuyama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshiyuki","family":"Fukugawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shinya","family":"Shiraishi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshinobu","family":"Shimohigashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masato","family":"Maruyama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Natsuo","family":"Oya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,12,13]]},"reference":[{"key":"911_CR1","doi-asserted-by":"publisher","first-page":"2041","DOI":"10.1016\/S0140-6736(05)66698-6","volume":"365","author":"WI Wei","year":"2005","unstructured":"Wei WI, Sham JS. Nasopharyngeal carcinoma. Lancet. 2005;365:2041\u201354.","journal-title":"Lancet"},{"key":"911_CR2","doi-asserted-by":"publisher","first-page":"541","DOI":"10.1093\/jrr\/rrw038","volume":"57","author":"R Toya","year":"2016","unstructured":"Toya R, Murakami R, Saito T, Murakami D, Matsuyama T, Baba Y, et al. Radiation therapy for nasopharyngeal carcinoma: the predictive value of interim survival assessment. J Radiat Res. 2016;57:541\u20137.","journal-title":"J Radiat Res."},{"key":"911_CR3","doi-asserted-by":"publisher","first-page":"405","DOI":"10.1093\/med\/9780198786757.003.0018","volume-title":"External beam therapy","author":"C Nutting","year":"2019","unstructured":"Nutting C, Gujral D. Head and neck cancer. In: Hoskin P, editor. External beam therapy. 3rd ed. Oxford: Oxford University Press; 2019. p. 405\u2013437.","edition":"3"},{"key":"911_CR4","doi-asserted-by":"publisher","first-page":"33","DOI":"10.3389\/fonc.2013.00033","volume":"3","author":"E Delikgoz Soykut","year":"2013","unstructured":"Delikgoz Soykut E, Ozsahin EM, Yukselen Guney Y, Aytac Arslan S, Derinalp Or O, Altundag MB, et al. The use of PET\/CT in radiotherapy planning: contribution of deformable registration. Front Oncol. 2013;3:33.","journal-title":"Front Oncol."},{"key":"911_CR5","doi-asserted-by":"publisher","first-page":"W146","DOI":"10.2214\/AJR.13.12420","volume":"203","author":"A Mohandas","year":"2014","unstructured":"Mohandas A, Marcus C, Kang H, Truong MT, Subramaniam RM. FDG PET\/CT in the management of nasopharyngeal carcinoma. AJR Am J Roentgenol. 2014;203:W146\u2013W157157.","journal-title":"AJR Am J Roentgenol."},{"key":"911_CR6","doi-asserted-by":"publisher","first-page":"494","DOI":"10.1002\/hed.20179","volume":"27","author":"M Koshy","year":"2005","unstructured":"Koshy M, Paulino AC, Howell R, Schuster D, Halkar R, Davis LW. F-18 FDG PET-CT fusion in radiotherapy treatment planning for head and neck cancer. Head Neck. 2005;27:494\u2013502.","journal-title":"Head Neck."},{"key":"911_CR7","doi-asserted-by":"publisher","first-page":"209","DOI":"10.1016\/j.radonc.2006.09.011","volume":"81","author":"U Nestle","year":"2006","unstructured":"Nestle U, Kremp S, Grosu AL. Practical integration of [18F]-FDG-PET and PET-CT in the planning of radiotherapy for non-small cell lung cancer (NSCLC): the technical basis, ICRU-target volumes, problems, perspectives. Radiother Oncol. 2006;81:209\u201325.","journal-title":"Radiother Oncol."},{"key":"911_CR8","first-page":"307","volume":"2","author":"A Tejwani","year":"2012","unstructured":"Tejwani A, Lavaf A, Parikh K, Mokhtar B, Swamy U, Emmolo J, et al. The role of PET\/CT in decreasing inter-observer variability in treatment planning and evaluation of response for cervical cancer. Am J Nucl Med Mol Imaging. 2012;2:307\u201313.","journal-title":"Am J Nucl Med Mol Imaging"},{"key":"911_CR9","doi-asserted-by":"publisher","first-page":"101","DOI":"10.3857\/roj.2017.00325","volume":"35","author":"S Oh","year":"2017","unstructured":"Oh S, Kim S. Deformable image registration in radiation therapy. Radiat Oncol J. 2017;35:101\u201311.","journal-title":"Radiat Oncol J."},{"key":"911_CR10","doi-asserted-by":"publisher","first-page":"578","DOI":"10.1016\/j.ijrobp.2008.09.041","volume":"73","author":"AB Hwang","year":"2009","unstructured":"Hwang AB, Bacharach SL, Yom SS, Weinberg VK, Quivey JM, Franc BL, et al. Can positron emission tomography (PET) or PET\/computed tomography (CT) acquired in a nontreatment position be accurately registered to a head-and-neck radiotherapy planning CT? Int J Radiat Oncol Biol Phys. 2009;73:578\u201384.","journal-title":"Int J Radiat Oncol Biol Phys."},{"key":"911_CR11","doi-asserted-by":"publisher","first-page":"952","DOI":"10.1016\/j.ijrobp.2007.02.017","volume":"68","author":"RH Ireland","year":"2007","unstructured":"Ireland RH, Dyker KE, Barber DC, Wood SM, Hanney MB, Tindale WB, et al. Nonrigid image registration for head and neck cancer radiotherapy treatment planning with PET\/CT. Int J Radiat Oncol Biol Phys. 2007;68:952\u20137.","journal-title":"Int J Radiat Oncol Biol Phys."},{"key":"911_CR12","doi-asserted-by":"publisher","first-page":"1329","DOI":"10.1148\/rg.325125008","volume":"32","author":"N Kovalchuk","year":"2012","unstructured":"Kovalchuk N, Jalisi S, Subramaniam RM, Truong MT. Deformable registration of preoperative PET\/CT with postoperative radiation therapy planning CT in head and neck cancer. Radiographics. 2012;32:1329\u201341.","journal-title":"Radiographics."},{"key":"911_CR13","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1186\/1748-717X-9-50","volume":"9","author":"D Fortin","year":"2014","unstructured":"Fortin D, Basran PS, Berrang T, Peterson D, Wai ES. Deformable versus rigid registration of PET\/CT images for radiation treatment planning of head and neck and lung cancer patients: a retrospective dosimetric comparison. Radiat Oncol. 2014;9:50.","journal-title":"Radiat Oncol."},{"key":"911_CR14","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1186\/s13014-016-0678-7","volume":"11","author":"AS Mohamed","year":"2016","unstructured":"Mohamed AS, Rosenthal DI, Awan MJ, Garden AS, Kocak-Uzel E, Belal AM, et al. Methodology for analysis and reporting patterns of failure in the Era of IMRT: head and neck cancer applications. Radiat Oncol. 2016;11:95.","journal-title":"Radiat Oncol."},{"key":"911_CR15","doi-asserted-by":"publisher","first-page":"546","DOI":"10.1093\/jrr\/rrz034","volume":"60","author":"N Kadoya","year":"2019","unstructured":"Kadoya N, Kito S, Kurooka M, Saito M, Takemura A, Tohyama N, et al. Factual survey of the clinical use of deformable image registration software for radiotherapy in Japan. J Radiat Res. 2019;60:546\u201353.","journal-title":"J Radiat Res."},{"key":"911_CR16","doi-asserted-by":"publisher","first-page":"e43","DOI":"10.1002\/mp.12256","volume":"44","author":"KK Brock","year":"2017","unstructured":"Brock KK, Mutic S, McNutt TR, Li H, Kessler ML. Use of image registration and fusion algorithms and techniques in radiotherapy: report of the AAPM Radiation Therapy Committee Task Group No. 132. Med Phys. 2017;44:e43\u2013e76.","journal-title":"Med Phys"},{"key":"911_CR17","doi-asserted-by":"publisher","first-page":"1451","DOI":"10.1109\/TMI.2006.880587","volume":"25","author":"WR Crum","year":"2006","unstructured":"Crum WR, Camara O, Hill DL. Generalized overlap measures for evaluation and validation in medical image analysis. IEEE Trans Med Imaging. 2006;25:1451\u201361.","journal-title":"IEEE Trans Med Imaging."},{"key":"911_CR18","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1186\/1748-717X-9-173","volume":"9","author":"D Thomson","year":"2014","unstructured":"Thomson D, Boylan C, Liptrot T, Aitkenhead A, Lee L, Yap B, et al. Evaluation of an automatic segmentation algorithm for definition of head and neck organs at risk. Radiat Oncol. 2014;9:173.","journal-title":"Radiat Oncol."},{"key":"911_CR19","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1093\/jrr\/rrt093","volume":"55","author":"N Kadoya","year":"2014","unstructured":"Kadoya N, Fujita Y, Katsuta Y, Dobashi S, Takeda K, Kishi K, et al. Evaluation of various deformable image registration algorithms for thoracic images. J Radiat Res. 2014;55:175\u201382.","journal-title":"J Radiat Res."},{"key":"911_CR20","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1120\/jacmp.v17i3.5735","volume":"17","author":"J Pukala","year":"2016","unstructured":"Pukala J, Johnson PB, Shah AP, Langen KM, Bova FJ, Staton RJ, et al. Benchmarking of five commercial deformable image registration algorithms for head and neck patients. J Appl Clin Med Phys. 2016;17:25\u201340.","journal-title":"J Appl Clin Med Phys."},{"key":"911_CR21","doi-asserted-by":"publisher","first-page":"693","DOI":"10.1080\/02841850802027034","volume":"49","author":"R Murakami","year":"2008","unstructured":"Murakami R, Uozumi H, Hirai T, Nishimura R, Katsuragawa S, Shiraishi S, et al. Impact of FDG-PET\/CT fused imaging on tumor volume assessment of head-and-neck squamous cell carcinoma: intermethod and interobserver variations. Acta Radiol. 2008;49:693\u20139.","journal-title":"Acta Radiol."},{"key":"911_CR22","first-page":"4","volume":"36","author":"N Nagami","year":"2019","unstructured":"Nagami N, Arimura H, Soufi M, Ohishi M, Imaizumi T, Yamaguchi Y, et al. An approach for evaluation of delineation accuracy of GTV contours with considering interobserver variability in reference contours: impact of MAR on radiation treatment planning. Med Imaging Inf Sci. 2019;36:4\u20139.","journal-title":"Med Imaging Inf Sci."},{"key":"911_CR23","first-page":"80","volume":"3","author":"J Li","year":"2013","unstructured":"Li J, Xiao Y. Application of FDG-PET\/CT in radiation oncology. Front Oncol. 2013;3:80.","journal-title":"Front Oncol."},{"key":"911_CR24","doi-asserted-by":"publisher","first-page":"322","DOI":"10.1016\/j.radonc.2011.08.036","volume":"101","author":"S Gaede","year":"2011","unstructured":"Gaede S, Olsthoorn J, Louie AV, Palma D, Yu E, Yaremko B, et al. An evaluation of an automated 4D-CT contour propagation tool to define an internal gross tumour volume for lung cancer radiotherapy. Radiother Oncol. 2011;101:322\u20138.","journal-title":"Radiother Oncol."},{"key":"911_CR25","doi-asserted-by":"publisher","first-page":"e0131801","DOI":"10.1371\/journal.pone.0131801","volume":"10","author":"J Jiang","year":"2015","unstructured":"Jiang J, Wu H, Huang M, Wu Y, Wang Q, Zhao J, et al. Variability of gross tumor volume in nasopharyngeal carcinoma using 11C-choline and 18F-FDG PET\/CT. PLoS ONE. 2015;10:e0131801.","journal-title":"PLoS ONE"},{"key":"911_CR26","doi-asserted-by":"publisher","first-page":"462","DOI":"10.1007\/s10278-018-00173-0","volume":"32","author":"L Zhao","year":"2019","unstructured":"Zhao L, Lu Z, Jiang J, Zhou Y, Wu Y, Feng Q. Automatic nasopharyngeal carcinoma segmentation using fully convolutional networks with auxiliary paths on dual-modality PET-CT images. J Digit Imaging. 2019;32:462\u201370.","journal-title":"J Digit Imaging."},{"key":"911_CR27","doi-asserted-by":"publisher","first-page":"315","DOI":"10.3389\/fonc.2017.00315","volume":"7","author":"K Men","year":"2017","unstructured":"Men K, Chen X, Zhang Y, Zhang T, Dai J, Yi J, et al. Deep deconvolutional neural network for target segmentation of nasopharyngeal cancer in planning computed tomography images. Front Oncol. 2017;7:315.","journal-title":"Front Oncol."},{"key":"911_CR28","doi-asserted-by":"publisher","first-page":"422","DOI":"10.1016\/j.ijrobp.2016.05.012","volume":"96","author":"N Kadoya","year":"2016","unstructured":"Kadoya N, Nakajima Y, Saito M, Miyabe Y, Kurooka M, Kito S, et al. Multi-institutional validation study of commercially available deformable image registration software for thoracic images. Int J Radiat Oncol Biol Phys. 2016;96:422\u201331.","journal-title":"Int J Radiat Oncol Biol Phys."},{"key":"911_CR29","doi-asserted-by":"publisher","first-page":"328","DOI":"10.1120\/jacmp.v17i2.5778","volume":"17","author":"K Nie","year":"2016","unstructured":"Nie K, Pouliot J, Smith E, Chuang C. Performance variations among clinically available deformable image registration tools in adaptive radiotherapy\u2014how should we evaluate and interpret the result? J Appl Clin Med Phys. 2016;17:328\u201340.","journal-title":"J Appl Clin Med Phys."}],"container-title":["Japanese Journal of Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11604-019-00911-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11604-019-00911-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11604-019-00911-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,12,12]],"date-time":"2020-12-12T00:47:49Z","timestamp":1607734069000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11604-019-00911-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12,13]]},"references-count":29,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2020,3]]}},"alternative-id":["911"],"URL":"https:\/\/doi.org\/10.1007\/s11604-019-00911-6","relation":{},"ISSN":["1867-1071","1867-108X"],"issn-type":[{"value":"1867-1071","type":"print"},{"value":"1867-108X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,12,13]]},"assertion":[{"value":"7 September 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 December 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 December 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This study was approved by the institutional ethics review board of Kumamoto University Hospital.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical statement"}},{"value":"Subjects\u2019 informed consent was obtained.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}