{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,12,28]],"date-time":"2023-12-28T05:26:35Z","timestamp":1703741195009},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2020,4,15]],"date-time":"2020-04-15T00:00:00Z","timestamp":1586908800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,4,15]],"date-time":"2020-04-15T00:00:00Z","timestamp":1586908800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Jpn J Radiol"],"published-print":{"date-parts":[[2020,9]]},"DOI":"10.1007\/s11604-020-00970-0","type":"journal-article","created":{"date-parts":[[2020,4,15]],"date-time":"2020-04-15T16:03:31Z","timestamp":1586966611000},"page":"890-898","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Cardiac motion non-influential in percutaneous computed tomography-guided biopsies of small (\u2264\u200920\u00a0mm) lung nodules near pericardium"],"prefix":"10.1007","volume":"38","author":[{"given":"Chao","family":"Chen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yaohui","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaofei","family":"Sun","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaoxia","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guodong","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haozhe","family":"Huang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wentao","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xinhong","family":"He","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,4,15]]},"reference":[{"key":"970_CR1","doi-asserted-by":"publisher","first-page":"2474","DOI":"10.1002\/1097-0142(20001201)89:11+<2474::AID-CNCR26>3.0.CO;2-2","volume":"89","author":"CI Henschke","year":"2000","unstructured":"Henschke CI. Early lung cancer action project: overall design and findings from baseline screening. Cancer. 2000;89:2474\u201382.","journal-title":"Cancer"},{"key":"970_CR2","doi-asserted-by":"publisher","first-page":"773","DOI":"10.1148\/radiol.2223010490","volume":"222","author":"S Diederich","year":"2002","unstructured":"Diederich S, Wormanns D, Semik M, Thomas M, Lenzen H, Roos N, et al. Screening for early lung cancer with low-dose spiral CT: prevalence in 817 asymptomatic smokers. Radiology. 2002;222:773\u201381.","journal-title":"Radiology"},{"key":"970_CR3","doi-asserted-by":"publisher","first-page":"e43","DOI":"10.1016\/j.crad.2012.09.008","volume":"68","author":"Y Li","year":"2013","unstructured":"Li Y, Du Y, Yang HF, Yu JH, Xu XX. CT-guided percutaneous core needle biopsy for small (\u226420 mm) pulmonary lesions. Clin Radiol. 2013;68:e43\u2013e4848.","journal-title":"Clin Radiol"},{"key":"970_CR4","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1148\/radiol.13131265","volume":"271","author":"SM Lee","year":"2014","unstructured":"Lee SM, Park CM, Lee KH, Bahn YE, Kim JI, Goo JM. C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of lung nodules: clinical experience in 1108 patients. Radiology. 2014;271:291\u2013300.","journal-title":"Radiology"},{"key":"970_CR5","doi-asserted-by":"publisher","first-page":"323","DOI":"10.3348\/kjr.2018.0064","volume":"20","author":"SH Yoon","year":"2019","unstructured":"Yoon SH, Park CM, Lee KH, Lim KY, Suh YJ, Im DJ, et al. Analysis of complications of percutaneous transthoracic needle biopsy using CT-guidance modalities in a multicenter cohort of 10568 Biopsies. Korean J Radiol. 2019;20:323\u201331.","journal-title":"Korean J Radiol"},{"key":"970_CR6","doi-asserted-by":"publisher","first-page":"1763","DOI":"10.1056\/NEJMoa060476","volume":"355","author":"CI Henschke","year":"2006","unstructured":"International Early Lung Cancer Action Program I, Henschke CI, Yankelevitz DF, Libby DM, Pasmantier MW, Smith JP, et al. Survival of patients with stage I lung cancer detected on CT screening. N Engl J Med. 2006;355:1763\u201371.","journal-title":"N Engl J Med"},{"key":"970_CR7","doi-asserted-by":"publisher","first-page":"408","DOI":"10.1016\/j.athoracsur.2006.02.029","volume":"82","author":"A El-Sherif","year":"2006","unstructured":"El-Sherif A, Gooding WE, Santos R, Pettiford B, Ferson PF, Fernando HC, et al. Outcomes of sublobar resection versus lobectomy for stage I non-small cell lung cancer: a 13-year analysis. Ann Thorac Surg. 2006;82:408\u201315 (discussion 15\u20136).","journal-title":"Ann Thorac Surg"},{"key":"970_CR8","doi-asserted-by":"publisher","first-page":"823","DOI":"10.1148\/radiol.2253011465","volume":"225","author":"MJ Wallace","year":"2002","unstructured":"Wallace MJ, Krishnamurthy S, Broemeling LD, Gupta S, Ahrar K, Morello FA Jr, et al. CT-guided percutaneous fine-needle aspiration biopsy of small (\u22641-cm) pulmonary lesions. Radiology. 2002;225:823\u20138.","journal-title":"Radiology"},{"key":"970_CR9","doi-asserted-by":"publisher","first-page":"920","DOI":"10.1136\/thorax.58.11.920","volume":"58","author":"A Manhire","year":"2003","unstructured":"Manhire A, Charig M, Clelland C, Gleeson F, Miller R, Moss H, et al. Guidelines for radiologically guided lung biopsy. Thorax. 2003;58:920\u201336.","journal-title":"Thorax"},{"key":"970_CR10","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1016\/j.jvir.2018.06.013","volume":"30","author":"C Li","year":"2019","unstructured":"Li C, Liu B, Meng H, Lv W, Jia H. Efficacy and radiation exposure of ultra-low-dose chest CT at 100 kVp with tin filtration in CT-guided percutaneous core needle biopsy for small pulmonary lesions using a third-generation dual-source CT scanner. J Vasc Interv Radiol. 2019;30:95\u2013102.","journal-title":"J Vasc Interv Radiol"},{"key":"970_CR11","doi-asserted-by":"publisher","first-page":"475","DOI":"10.1148\/radiol.2291020499","volume":"229","author":"PR Geraghty","year":"2003","unstructured":"Geraghty PR, Kee ST, McFarlane G, Razavi MK, Sze DY, Dake MD. CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate. Radiology. 2003;229:475\u201381.","journal-title":"Radiology"},{"key":"970_CR12","doi-asserted-by":"publisher","first-page":"239","DOI":"10.2214\/ajr.175.1.1750239","volume":"175","author":"H Tsukada","year":"2000","unstructured":"Tsukada H, Satou T, Iwashima A, Souma T. Diagnostic accuracy of CT-guided automated needle biopsy of lung nodules. Am J Roentgenol. 2000;175:239\u201343.","journal-title":"Am J Roentgenol"},{"key":"970_CR13","doi-asserted-by":"publisher","first-page":"1142","DOI":"10.1007\/s11547-007-0212-y","volume":"112","author":"AM Priola","year":"2007","unstructured":"Priola AM, Priola SM, Cataldi A, Errico L, Di Franco M, Campisi P, et al. Accuracy of CT-guided transthoracic needle biopsy of lung lesions: factors affecting diagnostic yield. Radiol Med (Torino). 2007;112:1142\u201359.","journal-title":"Radiol Med (Torino)"},{"key":"970_CR14","doi-asserted-by":"publisher","first-page":"115S","DOI":"10.1378\/chest.123.1_suppl.115S","volume":"123","author":"G Schreiber","year":"2003","unstructured":"Schreiber G, McCrory DC. Performance characteristics of different modalities for diagnosis of suspected lung cancer: summary of published evidence. Chest. 2003;123:115S\u2013S12828.","journal-title":"Chest"},{"key":"970_CR15","doi-asserted-by":"publisher","first-page":"266","DOI":"10.1007\/s002700010067","volume":"23","author":"F Laurent","year":"2000","unstructured":"Laurent F, Latrabe V, Vergier B, Michel P. Percutaneous CT-guided biopsy of the lung: comparison between aspiration and automated cutting needles using a coaxial technique. Cardiovasc Intervent Radiol. 2000;23:266\u201372.","journal-title":"Cardiovasc Intervent Radiol"},{"key":"970_CR16","doi-asserted-by":"publisher","first-page":"1665","DOI":"10.2214\/ajr.180.6.1801665","volume":"180","author":"Y Ohno","year":"2003","unstructured":"Ohno Y, Hatabu H, Takenaka D, Higashino T, Watanabe H, Ohbayashi C, et al. CT-guided transthoracic needle aspiration biopsy of small (\u226420 mm) solitary pulmonary nodules. Am J Roentgenol. 2003;180:1665\u20139.","journal-title":"Am J Roentgenol"},{"key":"970_CR17","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1016\/j.crad.2007.09.003","volume":"63","author":"YL Ng","year":"2008","unstructured":"Ng YL, Patsios D, Roberts H, Walsham A, Paul NS, Chung T, et al. CT-guided percutaneous fine-needle aspiration biopsy of pulmonary nodules measuring 10 mm or less. Clin Radiol. 2008;63:272\u20137.","journal-title":"Clin Radiol"},{"key":"970_CR18","doi-asserted-by":"publisher","first-page":"e8558","DOI":"10.1097\/MD.0000000000008558","volume":"96","author":"LS Hsu","year":"2017","unstructured":"Hsu LS, Chen CW, Chang CH, Liao CH, Hsu SL, Lin WM. Influences of cardiac motion on computed tomography-guided biopsy of lung nodules located near the heart. Medicine. 2017;96:e8558.","journal-title":"Medicine"},{"key":"970_CR19","doi-asserted-by":"publisher","first-page":"748","DOI":"10.1378\/chest.126.3.748","volume":"126","author":"KM Yeow","year":"2004","unstructured":"Yeow KM, Su IH, Pan KT, Tsay PK, Lui KW, Cheung YC, et al. Risk factors of pneumothorax and bleeding: multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies. Chest. 2004;126:748\u201354.","journal-title":"Chest"},{"key":"970_CR20","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1148\/radiol.2015150381","volume":"279","author":"R Tai","year":"2016","unstructured":"Tai R, Dunne RM, Trotman-Dickenson B, Jacobson FL, Madan R, Kumamaru KK, et al. Frequency and severity of pulmonary hemorrhage in patients undergoing percutaneous CT-guided transthoracic lung biopsy: single-institution experience of 1175 cases. Radiology. 2016;279:287\u201396.","journal-title":"Radiology"},{"key":"970_CR21","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1378\/chest.82.1.120","volume":"82","author":"W Kucharczyk","year":"1982","unstructured":"Kucharczyk W, Weisbrod GL, Cooper JD, Todd T. Cardiac tamponade as a complication of thin-needle aspiration lung biopsy. Chest. 1982;82:120\u20131.","journal-title":"Chest"},{"key":"970_CR22","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1097\/00005382-199109000-00017","volume":"6","author":"JE Shevland","year":"1991","unstructured":"Shevland JE. Right ventricular perforation: a rare complication of percutaneous lung biopsy. J Thorac Imaging. 1991;6:85\u20136.","journal-title":"J Thorac Imaging"},{"issue":"Suppl 2","key":"970_CR23","doi-asserted-by":"publisher","first-page":"S227","DOI":"10.1007\/s00270-007-9210-7","volume":"31","author":"MJ Mitchell","year":"2008","unstructured":"Mitchell MJ, Montgomery M, Reiter CG, Culp WC Jr. Pericardial tamponade following CT-guided lung biopsy. Cardiovasc Intervent Radiol. 2008;31(Suppl 2):S227\u2013S23030.","journal-title":"Cardiovasc Intervent Radiol"},{"key":"970_CR24","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1016\/j.lungcan.2009.04.007","volume":"67","author":"YC Cheung","year":"2010","unstructured":"Cheung YC, Chang JW, Hsieh JJ, Lin G, Tsai YH. Adequacy and complications of computed tomography-guided core needle biopsy on non-small cell lung cancers for epidermal growth factor receptor mutations demonstration: 18-gauge or 20-gauge biopsy needle. Lung Cancer. 2010;67:166\u20139.","journal-title":"Lung Cancer"},{"key":"970_CR25","doi-asserted-by":"publisher","first-page":"e407","DOI":"10.5114\/pjr.2018.79205","volume":"83","author":"K Ozturk","year":"2018","unstructured":"Ozturk K, Soylu E, Gokalp G, Topal U. Risk factors of pneumothorax and chest tube placement after computed tomography-guided core needle biopsy of lung lesions: a single-centre experience with 822 biopsies. Pol J Radiol. 2018;83:e407\u2013e414414.","journal-title":"Pol J Radiol"},{"key":"970_CR26","doi-asserted-by":"publisher","first-page":"1759","DOI":"10.2214\/ajr.174.6.1741759","volume":"174","author":"AM Rozenblit","year":"2000","unstructured":"Rozenblit AM, Tuvia J, Rozenblit GN, Klink A. CT-guided transthoracic needle biopsy using an ipsilateral dependent position. Am J Roentgenol. 2000;174:1759\u201364.","journal-title":"Am J Roentgenol"},{"key":"970_CR27","doi-asserted-by":"publisher","first-page":"461","DOI":"10.2214\/AJR.18.19871","volume":"212","author":"T Leger","year":"2019","unstructured":"Leger T, Jerjir N, Gregory J, Bennani S, Freche G, Revel MP, et al. Does ipsilateral-dependent positioning during percutaneous lung biopsy decrease the risk of pneumothorax? Am J Roentgenol. 2019;212:461\u20136.","journal-title":"Am J Roentgenol"},{"key":"970_CR28","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1148\/radiol.2019182321","volume":"292","author":"O Drumm","year":"2019","unstructured":"Drumm O, Joyce EA, de Blacam C, Gleeson T, Kavanagh J, McCarthy E, et al. CT-guided lung biopsy: effect of biopsy-side down position on pneumothorax and chest tube placement. Radiology. 2019;292:190\u20136.","journal-title":"Radiology"},{"key":"970_CR29","doi-asserted-by":"publisher","first-page":"W322","DOI":"10.2214\/AJR.11.7576","volume":"199","author":"JW Choi","year":"2012","unstructured":"Choi JW, Park CM, Goo JM, Park YK, Sung W, Lee HJ, et al. C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of small (\u226420 mm) lung nodules: diagnostic accuracy and complications in 161 patients. Am J Roentgenol. 2012;199:W322\u2013W330330.","journal-title":"Am J Roentgenol"},{"key":"970_CR30","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1053\/crad.1999.0368","volume":"55","author":"F Laurent","year":"2000","unstructured":"Laurent F, Latrabe V, Vergier B, Montaudon M, Vernejoux JM, Dubrez J. CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: results with an automated 20-gauge coaxial cutting needle. Clin Radiol. 2000;55:281\u20137.","journal-title":"Clin Radiol"},{"key":"970_CR31","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1590\/s1806-37562017000000259","volume":"44","author":"JR Andrade","year":"2018","unstructured":"Andrade JR, Rocha RD, Falsarella PM, Rahal Junior A, Santos RSD, Franceschini JP, et al. CT-guided percutaneous core needle biopsy of pulmonary nodules smaller than 2 cm: technical aspects and factors influencing accuracy. J Brasil Pneumol. 2018;44:307\u201314.","journal-title":"J Brasil Pneumol"},{"key":"970_CR32","doi-asserted-by":"publisher","first-page":"1945","DOI":"10.1016\/j.ejrad.2014.06.023","volume":"83","author":"NE Nour-Eldin","year":"2014","unstructured":"Nour-Eldin NE, Alsubhi M, Naguib NN, Lehnert T, Emam A, Beeres M, et al. Risk factor analysis of pulmonary hemorrhage complicating CT-guided lung biopsy in coaxial and non-coaxial core biopsy techniques in 650 patients. Eur J Radiol. 2014;83:1945\u201352.","journal-title":"Eur J Radiol"},{"key":"970_CR33","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1007\/s00330-010-1889-1","volume":"21","author":"NE Nour-Eldin","year":"2011","unstructured":"Nour-Eldin NE, Naguib NN, Mack M, Abskharon JE, Vogl TJ. Pulmonary hemorrhage complicating radiofrequency ablation, from mild hemoptysis to life-threatening pattern. Eur Radiol. 2011;21:197\u2013204.","journal-title":"Eur Radiol"},{"key":"970_CR34","doi-asserted-by":"publisher","first-page":"105","DOI":"10.2214\/ajr.167.1.8659351","volume":"167","author":"H Li","year":"1996","unstructured":"Li H, Boiselle PM, Shepard JO, Trotman-Dickenson B, McLoud TC. Diagnostic accuracy and safety of CT-guided percutaneous needle aspiration biopsy of the lung: comparison of small and large pulmonary nodules. Am J Roentgenol. 1996;167:105\u20139.","journal-title":"Am J Roentgenol"},{"key":"970_CR35","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1016\/j.lungcan.2005.10.019","volume":"51","author":"K Shimizu","year":"2006","unstructured":"Shimizu K, Ikeda N, Tsuboi M, Hirano T, Kato H. Percutaneous CT-guided fine needle aspiration for lung cancer smaller than 2 cm and revealed by ground-glass opacity at CT. Lung cancer. 2006;51:173\u20139.","journal-title":"Lung cancer"},{"key":"970_CR36","doi-asserted-by":"publisher","first-page":"631","DOI":"10.1148\/radiol.2342031423","volume":"234","author":"S Gupta","year":"2005","unstructured":"Gupta S, Krishnamurthy S, Broemeling LD, Morello FA Jr, Wallace MJ, Ahrar K, et al. Small (\u22642-cm) subpleural pulmonary lesions: short- versus long-needle-path CT-guided biopsy\u2013comparison of diagnostic yields and complications. Radiology. 2005;234:631\u20137.","journal-title":"Radiology"}],"container-title":["Japanese Journal of Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11604-020-00970-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11604-020-00970-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11604-020-00970-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,12,24]],"date-time":"2021-12-24T03:16:45Z","timestamp":1640315805000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11604-020-00970-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4,15]]},"references-count":36,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2020,9]]}},"alternative-id":["970"],"URL":"https:\/\/doi.org\/10.1007\/s11604-020-00970-0","relation":{},"ISSN":["1867-1071","1867-108X"],"issn-type":[{"value":"1867-1071","type":"print"},{"value":"1867-108X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,4,15]]},"assertion":[{"value":"16 September 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 April 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 April 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}