{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,10]],"date-time":"2026-10-10T07:10:46Z","timestamp":1791616246628,"version":"4.3.4"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2021,10,24]],"date-time":"2021-10-24T00:00:00Z","timestamp":1635033600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,10,24]],"date-time":"2021-10-24T00:00:00Z","timestamp":1635033600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Jpn J Radiol"],"published-print":{"date-parts":[[2022,3]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>The purpose of this study was to investigate the usefulness of temporal subtraction CT (TSCT) of temporal bone CT for the detection of postoperative recurrent\/residual cholesteatoma of the middle ear.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Thirty-two consecutive patients with surgically proven postoperative recurrent\/residual cholesteatoma and 14 consecutive patients without recurrent\/residual lesion matched the selection criteria and were retrospectively evaluated. TSCT imaging was generated with the use of serial postoperative CT. Two experienced radiologists and two residents evaluated the presence of bone erosive change by comparison serial CT studies, and CT and TSCT. The detection rate of bone erosive change, sensitivity and specificity of the recurrence\/residual lesions, and reading time for each reader were evaluated.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>TSCT\u2009+\u2009CT significantly improved the detection of bone erosive changes compared to CT-only evaluation (17.4\u201341.3% vs. 37.0\u201358.7%, <jats:italic>p<\/jats:italic>\u2009=\u20090.008\u20130.046). The mean sensitivity and specificity of TSCT\u2009+\u2009CT for experienced radiologists were 0.77 and 1.00, and 0.52 and 0.97 without TSCT. The mean sensitivity and specificity of TSCT\u2009+\u2009CT for residents were 0.64 and 1.00, and 0.41 and 1.00 without TSCT. Sensitivity showed an increase in all readers. The use of TSCT significantly reduced the reading time per case in all readers (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>TSCT improves the depiction of newly occurring progressive bone erosive changes, and detection sensitivity and reading time in postoperative recurrence\/residual cholesteatoma of middle ear.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s11604-021-01209-2","type":"journal-article","created":{"date-parts":[[2021,10,24]],"date-time":"2021-10-24T05:02:16Z","timestamp":1635051736000},"page":"271-278","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Improved assessment of middle ear recurrent\/residual cholesteatomas using temporal subtraction CT"],"prefix":"10.1007","volume":"40","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6913-5307","authenticated-orcid":false,"given":"Akira","family":"Baba","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9940-5205","authenticated-orcid":false,"given":"Satoshi","family":"Matsushima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7196-1413","authenticated-orcid":false,"given":"Takeshi","family":"Fukuda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hideomi","family":"Yamauchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroaki","family":"Fujioka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jun","family":"Hasumi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shohei","family":"Yoshimoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomokazu","family":"Shoji","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6263-0070","authenticated-orcid":false,"given":"Sho","family":"Kurihara","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4577-1234","authenticated-orcid":false,"given":"Yutaka","family":"Yamamoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2967-2110","authenticated-orcid":false,"given":"Hiromi","family":"Kojima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1186-8900","authenticated-orcid":false,"given":"Ryo","family":"Kurokawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3907-9188","authenticated-orcid":false,"given":"Mariko","family":"Kurokawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8992-2156","authenticated-orcid":false,"given":"Yoshiaki","family":"Ota","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5573-6299","authenticated-orcid":false,"given":"Hiroya","family":"Ojiri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,10,24]]},"reference":[{"key":"1209_CR1","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1016\/j.ejrad.2009.01.025","volume":"74","author":"NC Cimsit","year":"2010","unstructured":"Cimsit NC, Cimsit C, Baysal B, et al. Diffusion-weighted MR imaging in postoperative follow-up: reliability for detection of recurrent cholesteatoma. Eur J Radiol. 2010;74:121\u20133. https:\/\/doi.org\/10.1016\/j.ejrad.2009.01.025.","journal-title":"Eur J Radiol"},{"key":"1209_CR2","doi-asserted-by":"publisher","first-page":"536","DOI":"10.1111\/coa.12762","volume":"42","author":"J Muzaffar","year":"2017","unstructured":"Muzaffar J, Metcalfe C, Colley S, Coulson C. Diffusion-weighted magnetic resonance imaging for residual and recurrent cholesteatoma: a systematic review and meta-analysis. Clin Otolaryngol. 2017;42:536\u201343. https:\/\/doi.org\/10.1111\/coa.12762.","journal-title":"Clin Otolaryngol"},{"key":"1209_CR3","doi-asserted-by":"publisher","first-page":"274","DOI":"10.1046\/j.1365-2273.1999.00238.x","volume":"24","author":"PA Tierney","year":"1999","unstructured":"Tierney PA, Pracy P, Blaney SPA, Bowdler DA. An assessment of the value of the preoperative computed tomography scans prior to otoendoscopic \u2018second look\u2019 in intact canal wall mastoid surgery. Clin Otolaryngol Allied Sci. 1999;24:274\u20136. https:\/\/doi.org\/10.1046\/j.1365-2273.1999.00238.x.","journal-title":"Clin Otolaryngol Allied Sci"},{"key":"1209_CR4","first-page":"144","volume":"11","author":"L Migirov","year":"2009","unstructured":"Migirov L, Tal S, Eyal A, Kronenberg J. MRI, not CT, to rule out recurrent cholesteatoma and avoid unnecessary second-look mastoidectomy. Isr Med Assoc J. 2009;11:144\u20136.","journal-title":"Isr Med Assoc J"},{"key":"1209_CR5","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1148\/radiol.2017161942","volume":"285","author":"R Sakamoto","year":"2017","unstructured":"Sakamoto R, Yakami M, Fujimoto K, et al. Temporal subtraction of serial CT images with large deformation diffeomorphic metric mapping in the identification of bone metastases. Radiology. 2017;285:629\u201339. https:\/\/doi.org\/10.1148\/radiol.2017161942.","journal-title":"Radiology"},{"key":"1209_CR6","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1016\/j.ejrad.2019.07.024","volume":"118","author":"S Hoshiai","year":"2019","unstructured":"Hoshiai S, Masumoto T, Hanaoka S, et al. Clinical usefulness of temporal subtraction CT in detecting vertebral bone metastases. Eur J Radiol. 2019;118:175\u201380. https:\/\/doi.org\/10.1016\/j.ejrad.2019.07.024.","journal-title":"Eur J Radiol"},{"key":"1209_CR7","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1109\/42.836369","volume":"19","author":"M Holden","year":"2000","unstructured":"Holden M, Hill DLG, Denton ERE, et al. Voxel similarity measures for 3-D serial MR brain image registration. IEEE Trans Med Imaging. 2000;19:94\u2013102. https:\/\/doi.org\/10.1109\/42.836369.","journal-title":"IEEE Trans Med Imaging"},{"key":"1209_CR8","doi-asserted-by":"publisher","first-page":"e18","DOI":"10.1055\/s-0039-1697989","volume":"24","author":"PR M\u00f8ller","year":"2020","unstructured":"M\u00f8ller PR, Pedersen CN, Grosfjeld LR, et al. Recurrence of cholesteatoma\u2014a retrospective study including 1,006 patients for more than 33 years. Int Arch Otorhinolaryngol. 2020;24:e18\u201323. https:\/\/doi.org\/10.1055\/s-0039-1697989.","journal-title":"Int Arch Otorhinolaryngol"},{"key":"1209_CR9","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1148\/radiol.13130460","volume":"271","author":"T Aoki","year":"2013","unstructured":"Aoki T, Murakami S, Kim H, et al. Temporal subtraction method for lung nodule detection on successive thoracic CT soft-copy images. Radiology. 2013;271:255\u201361. https:\/\/doi.org\/10.1148\/radiol.13130460.","journal-title":"Radiology"},{"key":"1209_CR10","doi-asserted-by":"publisher","first-page":"959","DOI":"10.1016\/j.acra.2007.04.005","volume":"14","author":"J Shiraishi","year":"2007","unstructured":"Shiraishi J, Appelbaum D, Pu Y, et al. Usefulness of temporal subtraction images for identification of interval changes in successive whole-body bone scans: JAFROC analysis of Radiologists\u2019 performance. Acad Radiol. 2007;14:959\u201366. https:\/\/doi.org\/10.1016\/j.acra.2007.04.005.","journal-title":"Acad Radiol"},{"key":"1209_CR11","doi-asserted-by":"publisher","DOI":"10.1007\/s11604-021-01196-4","author":"T Hiyama","year":"2021","unstructured":"Hiyama T, Kuno H, Sekiya K, et al. Subtraction iodine imaging with area detector CT to improve tumor delineation and measurability of tumor size and depth of invasion in tongue squamous cell carcinoma. Jpn J Radiol. 2021. https:\/\/doi.org\/10.1007\/s11604-021-01196-4.","journal-title":"Jpn J Radiol"},{"key":"1209_CR12","doi-asserted-by":"publisher","first-page":"135","DOI":"10.3174\/ajnr.A5906","volume":"40","author":"T Hiyama","year":"2019","unstructured":"Hiyama T, Kuno H, Sekiya K, et al. Bone subtraction iodine imaging using area detector CT for evaluation of skull base invasion by nasopharyngeal carcinoma. Am J Neuroradiol. 2019;40:135\u201341. https:\/\/doi.org\/10.3174\/ajnr.A5906.","journal-title":"Am J Neuroradiol"},{"key":"1209_CR13","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1007\/s11604-017-0629-8","volume":"35","author":"H Yokota","year":"2017","unstructured":"Yokota H, Goto M, Bamba C, et al. Reading efficiency can be improved by minor modification of assigned duties; a pilot study on a small team of general radiologists. Jpn J Radiol. 2017;35:262\u20138. https:\/\/doi.org\/10.1007\/s11604-017-0629-8.","journal-title":"Jpn J Radiol"},{"key":"1209_CR14","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1007\/s10278-016-9911-z","volume":"30","author":"D Forsberg","year":"2017","unstructured":"Forsberg D, Rosipko B, Sunshine JL. Radiologists\u2019 variation of time to read across different procedure types. J Digit Imaging. 2017;30:86\u201394. https:\/\/doi.org\/10.1007\/s10278-016-9911-z.","journal-title":"J Digit Imaging"},{"key":"1209_CR15","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1007\/s11604-018-0724-5","volume":"36","author":"KK Kumamaru","year":"2018","unstructured":"Kumamaru KK, Machitori A, Koba R, et al. Global and Japanese regional variations in radiologist potential workload for computed tomography and magnetic resonance imaging examinations. Jpn J Radiol. 2018;36:273\u201381. https:\/\/doi.org\/10.1007\/s11604-018-0724-5.","journal-title":"Jpn J Radiol"},{"key":"1209_CR16","doi-asserted-by":"publisher","first-page":"579","DOI":"10.1007\/s11604-018-0766-8","volume":"36","author":"D Hayashi","year":"2018","unstructured":"Hayashi D, Guermazi A. Taking a proactive role in patient management of important incidental imaging findings: how can we increase the \u2018value\u2019 of diagnostic radiology service and improve quality of patient care? Jpn J Radiol. 2018;36:579\u201380. https:\/\/doi.org\/10.1007\/s11604-018-0766-8.","journal-title":"Jpn J Radiol"},{"key":"1209_CR17","doi-asserted-by":"publisher","first-page":"575","DOI":"10.1007\/s11604-018-0770-z","volume":"36","author":"S Naganawa","year":"2018","unstructured":"Naganawa S, Korogi Y. Diagnostic radiology service in Japan. Jpn J Radiol. 2018;36:575\u20138. https:\/\/doi.org\/10.1007\/s11604-018-0770-z.","journal-title":"Jpn J Radiol"},{"key":"1209_CR18","doi-asserted-by":"publisher","first-page":"266","DOI":"10.1007\/s11604-015-0413-6","volume":"33","author":"A Nishie","year":"2015","unstructured":"Nishie A, Kakihara D, Nojo T, et al. Current radiologist workload and the shortages in Japan: how many full-time radiologists are required? Jpn J Radiol. 2015;33:266\u201372. https:\/\/doi.org\/10.1007\/s11604-015-0413-6.","journal-title":"Jpn J Radiol"},{"key":"1209_CR19","doi-asserted-by":"publisher","DOI":"10.1097\/RCT.0000000000001119","author":"R Kurokawa","year":"2021","unstructured":"Kurokawa R, Hagiwara A, Nakaya M, et al. Forward-projected model-based iterative reconstruction solution in temporal bone computed tomography: a comparison study of all reconstruction modes. J Comput Assist Tomogr. 2021. https:\/\/doi.org\/10.1097\/RCT.0000000000001119.","journal-title":"J Comput Assist Tomogr"},{"key":"1209_CR20","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0239459","author":"R Kurokawa","year":"2019","unstructured":"Kurokawa R, Maeda E, Mori H, et al. Evaluation of the depiction ability of the microanatomy of the temporal bone in quarter-detector CT: model-based iterative reconstruction vs hybrid iterative reconstruction. Medicine (Baltimore). 2019. https:\/\/doi.org\/10.1371\/journal.pone.0239459.","journal-title":"Medicine (Baltimore)"},{"key":"1209_CR21","doi-asserted-by":"publisher","first-page":"4793786","DOI":"10.1155\/2017\/4793786","volume":"2017","author":"T Kuruma","year":"2017","unstructured":"Kuruma T, Tanigawa T, Uchida Y, et al. Large cholesterol granuloma of the middle ear eroding into the middle cranial fossa. Case Rep Otolaryngol. 2017;2017:4793786. https:\/\/doi.org\/10.1155\/2017\/4793786.","journal-title":"Case Rep Otolaryngol"},{"key":"1209_CR22","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1097\/MAO.0000000000001566","volume":"38","author":"K Takahashi","year":"2017","unstructured":"Takahashi K, Morita Y, Ohshima S, et al. Bone density development of the temporal bone assessed by computed tomography. Otol Neurotol. 2017;38:5.","journal-title":"Otol Neurotol"}],"container-title":["Japanese Journal of Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11604-021-01209-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11604-021-01209-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11604-021-01209-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,3,3]],"date-time":"2022-03-03T00:05:00Z","timestamp":1646265900000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11604-021-01209-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10,24]]},"references-count":22,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2022,3]]}},"alternative-id":["1209"],"URL":"https:\/\/doi.org\/10.1007\/s11604-021-01209-2","relation":{},"ISSN":["1867-1071","1867-108X"],"issn-type":[{"value":"1867-1071","type":"print"},{"value":"1867-108X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,10,24]]},"assertion":[{"value":"16 July 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 October 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 October 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical statement"}}]}}