{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T03:34:37Z","timestamp":1779939277998,"version":"3.53.1"},"reference-count":38,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2025,3,12]],"date-time":"2025-03-12T00:00:00Z","timestamp":1741737600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,3,12]],"date-time":"2025-03-12T00:00:00Z","timestamp":1741737600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Jpn J Radiol"],"published-print":{"date-parts":[[2025,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>Digital subtraction angiography (DSA) is the gold standard for assessing cerebrovascular hemodynamics. DSA is predominantly utilized to evaluate the hemodynamic information of various cerebral diseases. However, DSA is relatively invasive and involves radiation exposure and risks of allergic reactions or renal dysfunction related to iodine-based contrast agents. Magnetic resonance DSA (MRDSA) with a gadolinium-based contrast agent is a popular method for assessing hemodynamics without radiation exposure. However, it has the disadvantage of the risk of allergy due to the contrast agent and lower temporal and spatial resolution than DSA. In recent years, arterial spin labeling-based noncontrast MRDSA (ASL-MRDSA), which utilizes blood labeled with radiofrequency pulses as an endogenous tracer, has been developed. ASL-MRDSA exhibits the same temporal resolution as DSA; therefore, it can yield dynamic information about various cerebral diseases. Pulsed ASL has been used as the major labeling method. However, the recent development of the pseudocontinuous ASL method has enabled high ASL signal maintenance even at delayed phases. This advancement allows for a more detailed assessment of hemodynamic information about vascular diseases, including major artery severe stenosis, occlusion, and moyamoya disease. Furthermore, combining it with superselective labeling pulses also allows for a more detailed hemodynamic assessment of complex vascular malformations such as DSA. In addition, ASL-MRDSA using ultrashort-echo time can acquire signals before phase dispersion occurs, which reduces artifacts induced by metallic materials and blood flow. This technique is useful for assessing post-clipping, post-coiling, and pseudostenosis. Furthermore, ASL-MRDSA using a wheel scan mode without full sampling achieves higher temporal resolution than DSA, which enables blood flow evaluation within giant cerebral aneurysms. Herein, we introduce the basic principles and various novel techniques of ASL-MRDSA and demonstrate its clinical applications, pitfalls, and limitations in cerebral disease diagnoses.<\/jats:p>","DOI":"10.1007\/s11604-025-01758-w","type":"journal-article","created":{"date-parts":[[2025,3,12]],"date-time":"2025-03-12T04:05:06Z","timestamp":1741752306000},"page":"1049-1065","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Noninvasive dynamic vascular imaging: arterial spin labeling-based noncontrast magnetic resonance digital subtraction angiography for cerebral disease diagnoses"],"prefix":"10.1007","volume":"43","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1267-5836","authenticated-orcid":false,"given":"Miho","family":"Gomyo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kazuhiro","family":"Tsuchiya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenichi","family":"Yokoyama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,3,12]]},"reference":[{"key":"1758_CR1","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1080\/028418500127345299","volume":"41","author":"AM Leffers","year":"2000","unstructured":"Leffers AM, Wagner A. Neurologic complications of cerebral angiography. A retrospective study of complication rate and patient risk factors. Acta Radiol. 2000;41:204\u201310.","journal-title":"Acta Radiol"},{"key":"1758_CR2","doi-asserted-by":"publisher","first-page":"e2330036","DOI":"10.2214\/AJR.23.30036","volume":"223","author":"J Starekova","year":"2024","unstructured":"Starekova J, Pirasteh A, Reeder SB. Update on gadolinium-based contrast agent safety, from the AJR special series on contrast media. AJR Am J Roentgenol. 2024;223:e2330036. https:\/\/doi.org\/10.2214\/AJR.23.30036.","journal-title":"AJR Am J Roentgenol"},{"key":"1758_CR3","doi-asserted-by":"publisher","first-page":"1494","DOI":"10.1007\/s00330-004-2281-9","volume":"14","author":"K Tsuchiya","year":"2004","unstructured":"Tsuchiya K, Aoki C, Fujikawa A, Hachiya J. Three-dimensional MR digital subtraction angiography using parallel imaging and keyhole data sampling in cerebrovascular diseases: initial experience. Eur Radiol. 2004;14:1494\u20137.","journal-title":"Eur Radiol"},{"key":"1758_CR4","doi-asserted-by":"publisher","first-page":"80","DOI":"10.3174\/ajnr.A1898","volume":"31","author":"S Nishimura","year":"2010","unstructured":"Nishimura S, Hirai T, Sasao A, Kitajima M, Morioka M, Kai Y, et al. Evaluation of dural arteriovenous fistulas with 4D contrast-enhanced MR angiography at 3T. AJNR Am J Neuroradiol. 2010;31:80\u20135.","journal-title":"AJNR Am J Neuroradiol"},{"key":"1758_CR5","doi-asserted-by":"publisher","first-page":"429","DOI":"10.1007\/s00330-011-2268-2","volume":"22","author":"A Bink","year":"2012","unstructured":"Bink A, Berkefeld J, Wagner M, You SJ, Ackermann H, Lorenz MW, et al. Detection and grading of dAVF: prospects and limitations of 3T MRI. Eur Radiol. 2012;22:429\u201338.","journal-title":"Eur Radiol"},{"key":"1758_CR6","doi-asserted-by":"publisher","first-page":"1305","DOI":"10.1002\/jmri.29119","volume":"60","author":"O Togao","year":"2024","unstructured":"Togao O, Obara M, Yamashita K, Kikuchi K, Wada T, Murazaki H, et al. Arterial spin labeling-based MR angiography for cerebrovascular diseases: principles and clinical applications. J Magn Reson Imaging. 2024;60:1305\u201324.","journal-title":"J Magn Reson Imaging"},{"key":"1758_CR7","doi-asserted-by":"publisher","first-page":"1525","DOI":"10.6009\/jjrt.2012_JSRT_68.11.1525","volume":"68","author":"M Nakamura","year":"2012","unstructured":"Nakamura M, Yoneyama M, Tabuchi T, Takemura A, Obara M, Sawano S. Non-contrast time-resolved magnetic resonance angiography combining high resolution multiple phase echo planar imaging based signal targeting and alternating radiofrequency contrast inherent inflow enhanced multi phase angiography combining spatial resolution echo planar imaging based signal targeting and alternating radiofrequency in intracranial arteries. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2012;68:1525\u201332.","journal-title":"Nihon Hoshasen Gijutsu Gakkai Zasshi"},{"key":"1758_CR8","doi-asserted-by":"publisher","first-page":"974","DOI":"10.1002\/mrm.1284","volume":"46","author":"M G\u00fcnther","year":"2001","unstructured":"G\u00fcnther M, Bock M, Schad LR. Arterial spin labeling in combination with a look-locker sampling strategy: inflow turbo-sampling EPI-FAIR (ITS-FAIR). Magn Reson Med. 2001;46:974\u201384.","journal-title":"Magn Reson Med"},{"key":"1758_CR9","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1136\/neurintsurg-2013-010982","volume":"7","author":"M Pearl","year":"2015","unstructured":"Pearl M, Torok C, Wang J, Wyse E, Mahesh M, Gailloud P. Practical techniques for reducing radiation exposure during cerebral angiography procedures. J Neurointerv Surg. 2015;7:141\u20135.","journal-title":"J Neurointerv Surg"},{"key":"1758_CR10","doi-asserted-by":"publisher","first-page":"719","DOI":"10.1002\/mrm.27074","volume":"80","author":"M Obara","year":"2018","unstructured":"Obara M, Togao O, Beck GM, Shibukawa S, Okuaki T, Yoneyama M, et al. Non-contrast enhanced 4D intracranial MR angiography based on pseudo-continuous arterial spin labeling with the keyhole and view-sharing technique. Magn Reson Med. 2018;80:719\u201325.","journal-title":"Magn Reson Med"},{"key":"1758_CR11","doi-asserted-by":"publisher","first-page":"830","DOI":"10.1002\/mrm.1910290618","volume":"29","author":"RA Jones","year":"1993","unstructured":"Jones RA, Haraldseth O, M\u00fcller TB, Rinck PA, Oksendal AN. K-space substitution: a novel dynamic imaging technique. Magn Reson Med. 1993;29:830\u20134.","journal-title":"Magn Reson Med"},{"key":"1758_CR12","doi-asserted-by":"publisher","first-page":"516","DOI":"10.1002\/mrm.10243","volume":"48","author":"J Du","year":"2002","unstructured":"Du J, Carroll TJ, Wagner HJ, Vigen K, Fain SB, Block WF, et al. Time-resolved, undersampled projection reconstruction imaging for high-resolution CE-MRA of the distal runoff vessels. Magn Reson Med. 2002;48:516\u201322.","journal-title":"Magn Reson Med"},{"key":"1758_CR13","doi-asserted-by":"publisher","first-page":"834","DOI":"10.1002\/jmri.25222","volume":"44","author":"N Fujima","year":"2016","unstructured":"Fujima N, Osanai T, Shimizu Y, Yoshida A, Harada T, Nakayama N, et al. Utility of noncontrast-enhanced time-resolved four-dimensional MR angiography with a vessel-selective technique for intracranial arteriovenous malformations. J Magn Reson Imaging. 2016;44:834\u201345.","journal-title":"J Magn Reson Imaging"},{"key":"1758_CR14","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1016\/j.mri.2020.07.013","volume":"73","author":"M Obara","year":"2020","unstructured":"Obara M, Togao O, Helle M, Murazaki H, Wada T, Yoneyama M, et al. Improved selective visualization of internal and external carotid artery in 4D-MR angiography based on super-selective pseudo-continuous arterial spin labeling combined with CENTRA-keyhole and view-sharing (4D-S-PACK). Magn Reson Imaging. 2020;73:15\u201322.","journal-title":"Magn Reson Imaging"},{"key":"1758_CR15","doi-asserted-by":"publisher","first-page":"65","DOI":"10.25259\/SNI_59_2020","volume":"11","author":"M Katsuki","year":"2020","unstructured":"Katsuki M, Kakizawa Y, Yamamoto Y, Nishikawa A, Wada N, Uchiyama T. Magnetic resonance angiography with ultrashort echo time evaluates cerebral aneurysm with clip. Surg Neurol Int. 2020;11:65.","journal-title":"Surg Neurol Int"},{"key":"1758_CR16","doi-asserted-by":"publisher","first-page":"193","DOI":"10.2176\/nmc.oa.2020-0336","volume":"61","author":"M Katsuki","year":"2021","unstructured":"Katsuki M, Narita N, Ishida N, Sugawara K, Watanabe O, Ozaki D, et al. Usefulness of 3 tesla ultrashort echo time magnetic resonance angiography (UTE-MRA, SILENT-MRA) for evaluation of the mother vessel after cerebral aneurysm clipping: case series of 19 patients. Neurol Med Chir. 2021;61:193\u2013203.","journal-title":"Neurol Med Chir"},{"key":"1758_CR17","doi-asserted-by":"publisher","first-page":"177","DOI":"10.6009\/jjrt.2020_JSRT_76.2.177","volume":"76","author":"S Takubo","year":"2020","unstructured":"Takubo S, Kawasaki K, Nagatari T, Matsumoto M, Kageyama T. Clinical usefulness of ultra-short TE MRA for follow-up imaging after cerebral aneurysm clipping. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2020;76:177\u201384.","journal-title":"Nihon Hoshasen Gijutsu Gakkai Zasshi"},{"key":"1758_CR18","doi-asserted-by":"publisher","first-page":"1610","DOI":"10.3174\/ajnr.A5223","volume":"38","author":"N Takano","year":"2017","unstructured":"Takano N, Suzuki M, Irie R, Yamamoto M, Teranishi K, Yatomi K, et al. Non-contrast-enhanced silent scan MR angiography of intracranial anterior circulation aneurysms treated with a low-profile visualized intraluminal support device. AJNR Am J Neuroradiol. 2017;38:1610\u20136.","journal-title":"AJNR Am J Neuroradiol"},{"key":"1758_CR19","doi-asserted-by":"publisher","first-page":"577","DOI":"10.3174\/ajnr.A5033","volume":"38","author":"N Takano","year":"2017","unstructured":"Takano N, Suzuki M, Irie R, Yamamoto M, Hamasaki N, Kamagata K, et al. Usefulness of non-contrast-enhanced MR angiography using a silent scan for follow-up after Y-configuration stent-assisted coil embolization for basilar tip aneurysms. AJNR Am J Neuroradiol. 2017;38:577\u201381.","journal-title":"AJNR Am J Neuroradiol"},{"key":"1758_CR20","doi-asserted-by":"publisher","first-page":"967","DOI":"10.3174\/ajnr.A4199","volume":"36","author":"R Irie","year":"2015","unstructured":"Irie R, Suzuki M, Yamamoto M, Takano N, Suga Y, Hori M, et al. Assessing blood flow in an intracranial stent: a feasibility study of MR angiography using a silent scan after stent-assisted coil embolization for anterior circulation aneurysms. AJNR Am J Neuroradiol. 2015;36:967\u201370.","journal-title":"AJNR Am J Neuroradiol"},{"key":"1758_CR21","doi-asserted-by":"publisher","first-page":"246","DOI":"10.3348\/kjr.2021.0332","volume":"23","author":"YN Kim","year":"2022","unstructured":"Kim YN, Choi JW, Lim YC, Song J, Park JH, Jung WS. Usefulness of silent MRA for evaluation of aneurysm after stent-assisted coil embolization. Korean J Radiol. 2022;23:246\u201355.","journal-title":"Korean J Radiol"},{"key":"1758_CR22","doi-asserted-by":"publisher","first-page":"819","DOI":"10.1097\/RCT.0000000000001590","volume":"48","author":"G Sasaki","year":"2024","unstructured":"Sasaki G, Uetani H, Nakaura T, Nakahara K, Morita K, Nagayama Y, et al. Optimizing high-resolution MR angiography: the synergistic effects of 3D wheel sampling and deep learning-based reconstruction. J Comput Assist Tomogr. 2024;48:819\u201325.","journal-title":"J Comput Assist Tomogr"},{"key":"1758_CR23","first-page":"88","volume":"25","author":"A Uemura","year":"2004","unstructured":"Uemura A, O'uchi T, Kikuchi Y, Yashiro N, Ihara N, Shoji K. Prominent laterality of the posterior cerebral artery at three-dimensional time-of-flight MR angiography in M1-segment middle cerebral artery occlusion. AJNR Am J Neuroradiol. 2004;25:88\u201391.","journal-title":"AJNR Am J Neuroradiol"},{"key":"1758_CR24","doi-asserted-by":"publisher","first-page":"2316","DOI":"10.1161\/STROKEAHA.110.592303","volume":"41","author":"FO Lima","year":"2010","unstructured":"Lima FO, Furie KL, Silva GS, Lev MH, Camargo EC, Singhal AB, et al. The pattern of leptomeningeal collaterals on CT angiography is a strong predictor of long-term functional outcome in stroke patients with large vessel intracranial occlusion. Stroke. 2010;41:2316\u201322.","journal-title":"Stroke"},{"key":"1758_CR25","doi-asserted-by":"publisher","first-page":"384","DOI":"10.1002\/jmri.22628","volume":"34","author":"I Koktzoglou","year":"2011","unstructured":"Koktzoglou I, Gupta N, Edelman RR. Nonenhanced extracranial carotid MR angiography using arterial spin labeling: improved performance with pseudocontinuous tagging. Magn Reson Imaging. 2011;34:384\u201394.","journal-title":"Magn Reson Imaging"},{"key":"1758_CR26","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1016\/j.clineuro.2015.07.003","volume":"137","author":"H Uchino","year":"2015","unstructured":"Uchino H, Ito M, Fujima N, Kazumata K, Yamazaki K, Nakayama N, et al. A novel application of four-dimensional magnetic resonance angiography using an arterial spin labeling technique for noninvasive diagnosis of Moyamoya disease. Clin Neurol Neurosurg. 2015;137:105\u201311.","journal-title":"Clin Neurol Neurosurg"},{"key":"1758_CR27","doi-asserted-by":"publisher","first-page":"4871","DOI":"10.1007\/s00330-018-5462-7","volume":"28","author":"O Togao","year":"2018","unstructured":"Togao O, Hiwatashi A, Obara M, Yamashita K, Momosaka D, Nishimura A, et al. 4D ASL-based MR angiography for visualization of distal arteries and leptomeningeal collateral vessels in moyamoya disease: a comparison of techniques. Eur Radiol. 2018;28:4871\u201381.","journal-title":"Eur Radiol"},{"key":"1758_CR28","doi-asserted-by":"publisher","first-page":"5263","DOI":"10.1007\/s00330-020-07503-3","volume":"31","author":"M Wang","year":"2021","unstructured":"Wang M, Yang Y, Wang Y, Li M, Zhang J, Zhang B. Vessel-selective 4D MRA based on ASL might potentially show better performance than 3D TOF MRA for treatment evaluation in patients with intra-extracranial bypass surgery: a prospective study. Eur Radiol. 2021;31:5263\u201371.","journal-title":"Eur Radiol"},{"key":"1758_CR29","doi-asserted-by":"publisher","first-page":"305","DOI":"10.1007\/s00234-014-1336-0","volume":"56","author":"J Jang","year":"2014","unstructured":"Jang J, Schmitt P, Kim BY, Choi HS, Jung SL, Ahn KJ, et al. Non-contrast-enhanced 4D-MR angiography with STAR spin labeling and variable flip angle sampling: a feasibility study for the assessment of dural arteriovenous fistula. Neuroradiology. 2014;56:305\u201314.","journal-title":"Neuroradiology"},{"key":"1758_CR30","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1148\/radiol.13122670","volume":"271","author":"Y Iryo","year":"2014","unstructured":"Iryo Y, Hirai T, Kai Y, Nakamura M, Shigematsu Y, Kitajima M, et al. Intracranial dural arteriovenous fistulas: evaluation with 3-T four-dimensional MR angiography using arterial spin labeling. Radiology. 2014;271:193\u20139.","journal-title":"Radiology"},{"key":"1758_CR31","doi-asserted-by":"publisher","first-page":"368","DOI":"10.3174\/ajnr.A7426","volume":"43","author":"O Togao","year":"2022","unstructured":"Togao O, Obara M, Kikuchi K, Helle M, Arimura K, Nishimura A, et al. Vessel-selective 4D-MRA using superselective pseudocontinuous arterial spin-labeling with keyhole and view-sharing for visualizing intracranial dural AVFs. AJNR Am J Neuroradiol. 2022;43:368\u201375.","journal-title":"AJNR Am J Neuroradiol"},{"key":"1758_CR32","doi-asserted-by":"publisher","first-page":"1199","DOI":"10.1002\/jmri.22699","volume":"34","author":"J Xu","year":"2011","unstructured":"Xu J, Shi D, Chen C, Li Y, Wang M, Han X, et al. Noncontrast-enhanced four-dimensional MR angiography for the evaluation of cerebral arteriovenous malformation: a preliminary trial. J Magn Reson Imaging. 2011;34:1199\u2013205.","journal-title":"J Magn Reson Imaging"},{"key":"1758_CR33","doi-asserted-by":"publisher","first-page":"869","DOI":"10.1016\/j.mri.2012.02.027","volume":"30","author":"S Yu","year":"2012","unstructured":"Yu S, Yan L, Yao Y, Wang S, Yang M, Wang B, et al. Noncontrast dynamic MRA in intracranial arteriovenous malformation (AVM), comparison with time of flight (TOF) and digital subtraction angiography (DSA). Magn Reson Imaging. 2012;30:869\u201377.","journal-title":"Magn Reson Imaging"},{"key":"1758_CR34","doi-asserted-by":"publisher","first-page":"6452","DOI":"10.1007\/s00330-020-07057-4","volume":"30","author":"O Togao","year":"2020","unstructured":"Togao O, Obara M, Helle M, Yamashita K, Kikuchi K, Momosaka D, et al. Vessel-selective 4D-MR angiography using super-selective pseudo-continuous arterial spin labeling may be a useful tool for assessing brain AVM hemodynamics. Eur Radiol. 2020;30:6452\u201363.","journal-title":"Eur Radiol"},{"key":"1758_CR35","doi-asserted-by":"publisher","first-page":"7923","DOI":"10.1007\/s00330-023-09755-1","volume":"33","author":"H Uetani","year":"2023","unstructured":"Uetani H, Kitajima M, Ohmori Y, Morita K, Yamashita Y, Kaku Y, et al. Intracranial aneurysms treated with stent-assisted coil embolization: evaluation with four-dimensional ultrashort-TE MR angiography. Eur Radiol. 2023;33:7923\u201333.","journal-title":"Eur Radiol"},{"key":"1758_CR36","doi-asserted-by":"publisher","first-page":"671","DOI":"10.3174\/ajnr.A6990","volume":"42","author":"A Rojas-Villabona","year":"2021","unstructured":"Rojas-Villabona A, Pizzini FB, Solbach T, Sokolska M, Ricciardi G, Lemonis C, et al. Are dynamic arterial spin-labeling MRA and time-resolved contrast-enhanced MRA suited for confirmation of obliteration following gamma knife radiosurgery of brain arteriovenous malformations? AJNR Am J Neuroradiol. 2021;42:671\u20138.","journal-title":"AJNR Am J Neuroradiol"},{"key":"1758_CR37","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1016\/j.mri.2024.04.022","volume":"110","author":"W Liao","year":"2024","unstructured":"Liao W, Shi G, Lv Y, Liu L, Tang X, Jin Y, et al. Accurate and robust segmentation of cerebral vasculature on four-dimensional arterial spin labeling magnetic resonance angiography using machine-learning approach. Magn Reson Imaging. 2024;110:86\u201395.","journal-title":"Magn Reson Imaging"},{"key":"1758_CR38","doi-asserted-by":"publisher","first-page":"2676","DOI":"10.1002\/mrm.26926","volume":"79","author":"Y Suzuki","year":"2018","unstructured":"Suzuki Y, Helle M, Koken P, Van Cauteren M, van Osch MJP. Simultaneous acquisition of perfusion image and dynamic MR angiography using time-encoded pseudo-continuous ASL. Magn Reson Med. 2018;79:2676\u201384.","journal-title":"Magn Reson Med"}],"container-title":["Japanese Journal of Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11604-025-01758-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11604-025-01758-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11604-025-01758-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,27]],"date-time":"2025-06-27T17:03:03Z","timestamp":1751043783000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11604-025-01758-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,12]]},"references-count":38,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2025,7]]}},"alternative-id":["1758"],"URL":"https:\/\/doi.org\/10.1007\/s11604-025-01758-w","relation":{},"ISSN":["1867-1071","1867-108X"],"issn-type":[{"value":"1867-1071","type":"print"},{"value":"1867-108X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,12]]},"assertion":[{"value":"17 December 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 February 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 March 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no conflict of interest concerning this publication.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This review article contains no studies with human subjects or animals performed by any authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}