{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,25]],"date-time":"2026-07-25T05:47:31Z","timestamp":1784958451912,"version":"3.55.0"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2025,8,9]],"date-time":"2025-08-09T00:00:00Z","timestamp":1754697600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,8,9]],"date-time":"2025-08-09T00:00:00Z","timestamp":1754697600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100004721","name":"The University of Tokyo","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100004721","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Jpn J Radiol"],"published-print":{"date-parts":[[2025,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To assess the efficacy of super-resolution deep learning reconstruction (SR-DLR) with motion reduction algorithm (SR-DLR-M) in mitigating aorta motion artifacts compared to SR-DLR and deep learning reconstruction with motion reduction algorithm (DLR-M).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>This retrospective study included 86 patients (mean age, 65.0\u2009\u00b1\u200914.1\u00a0years; 53 males) who underwent contrast-enhanced CT including the chest region. CT images were reconstructed with SR-DLR-M, SR-DLR, and DLR-M. Circular or ovoid regions of interest were placed on the aorta, and the standard deviation of the CT attenuation was recorded as quantitative noise. From the CT attenuation profile along a line region of interest that intersected the left common carotid artery wall, edge rise slope and edge rise distance were calculated. Two readers assessed the images based on artifact, sharpness, noise, structure depiction, and diagnostic acceptability (for aortic dissection).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Quantitative noise was 7.4\/5.4\/8.3 Hounsfield unit (HU) in SR-DLR-M\/SR-DLR\/DLR-M. Significant differences were observed between SR-DLR-M\n                      <jats:italic>vs.<\/jats:italic>\n                      SR-DLR and DLR-M (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001). Edge rise slope and edge rise distance were 107.1\/108.8\/85.8 HU\/mm and 1.6\/1.5\/2.0 mm, respectively, in SR-DLR-M\/SR-DLR\/DLR-M. Statistically significant differences were detected between SR-DLR-M\n                      <jats:italic>vs.<\/jats:italic>\n                      DLR-M (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009\u2264\u20090.001 for both). Two readers scored artifacts in SR-DLR-M as significantly better than those in SR-DLR (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001). Scores for sharpness, noise, and structure depiction in SR-DLR-M were significantly better than those in DLR-M (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009\u2264\u20090.005). Diagnostic acceptability in SR-DLR-M was significantly better than that in SR-DLR and DLR-M (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>SR-DLR-M provided significantly better CT images in diagnosing aortic dissection compared to SR-DLR and DLR-M.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s11604-025-01849-8","type":"journal-article","created":{"date-parts":[[2025,8,9]],"date-time":"2025-08-09T03:51:22Z","timestamp":1754711482000},"page":"1993-2002","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Reducing motion artifacts in the aorta: super-resolution deep learning reconstruction with motion reduction algorithm"],"prefix":"10.1007","volume":"43","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0324-6562","authenticated-orcid":false,"given":"Koichiro","family":"Yasaka","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rin","family":"Tsujimoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rintaro","family":"Miyo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Osamu","family":"Abe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,8,9]]},"reference":[{"key":"1849_CR1","volume":"38","author":"EMR Gouveia","year":"2022","unstructured":"Gouveia EMR, Machado C, Caldeira D, Alves M, Lopes A, Serrano M, et al. Incidence of acute aortic dissections in patients with out of hospital cardiac arrest: a systematic review and meta-analysis of observational studies. Int J Cardiol Heart Vasc. 2022;38: 100934.","journal-title":"Int J Cardiol Heart Vasc"},{"key":"1849_CR2","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1016\/j.ahj.2018.11.006","volume":"209","author":"N Huynh","year":"2019","unstructured":"Huynh N, Thordsen S, Thomas T, Mackey-Bojack SM, Duncanson ER, Nwuado D, et al. Clinical and pathologic findings of aortic dissection at autopsy: review of 336 cases over nearly 6 decades. Am Heart J. 2019;209:108\u201315.","journal-title":"Am Heart J"},{"issue":"10378","key":"1849_CR3","doi-asserted-by":"publisher","first-page":"773","DOI":"10.1016\/S0140-6736(22)01970-5","volume":"401","author":"T Carrel","year":"2023","unstructured":"Carrel T, Sundt TM 3rd, von Kodolitsch Y, Czerny M. Acute aortic dissection. Lancet. 2023;401(10378):773\u201388.","journal-title":"Lancet"},{"issue":"3","key":"1849_CR4","doi-asserted-by":"publisher","first-page":"785","DOI":"10.1016\/j.jtcvs.2020.09.147","volume":"164","author":"Y Okita","year":"2022","unstructured":"Okita Y, Kumamaru H, Motomura N, Miyata H, Takamoto S. Current status of open surgery for acute type A aortic dissection in Japan. J Thorac Cardiovasc Surg. 2022;164(3):785\u201394.","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"2","key":"1849_CR5","doi-asserted-by":"publisher","first-page":"445","DOI":"10.1148\/rg.302095104","volume":"30","author":"MA McMahon","year":"2010","unstructured":"McMahon MA, Squirrell CA. Multidetector CT of aortic dissection: a pictorial review. Radiographics. 2010;30(2):445\u201360.","journal-title":"Radiographics"},{"issue":"3","key":"1849_CR6","doi-asserted-by":"publisher","first-page":"465","DOI":"10.2214\/ajr.157.3.1872227","volume":"157","author":"MA Burns","year":"1991","unstructured":"Burns MA, Molina PL, Gutierrez FR, Sagel SS. Motion artifact simulating aortic dissection on CT. AJR Am J Roentgenol. 1991;157(3):465\u20137.","journal-title":"AJR Am J Roentgenol"},{"issue":"13","key":"1849_CR7","doi-asserted-by":"publisher","DOI":"10.1161\/JAHA.121.025026","volume":"11","author":"GJ Arnaoutakis","year":"2022","unstructured":"Arnaoutakis GJ, Ogami T, Aranda-Michel E, Dai Y, Holmes R, Beaver TM, et al. Misdiagnosis of thoracic aortic emergencies occurs frequently among transfers to aortic referral centers: an analysis of over 3700 patients. J Am Heart Assoc. 2022;11(13): e025026.","journal-title":"J Am Heart Assoc"},{"issue":"1","key":"1849_CR8","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1148\/radiol.2221010481","volume":"222","author":"JE Roos","year":"2002","unstructured":"Roos JE, Willmann JK, Weishaupt D, Lachat M, Marincek B, Hilfiker PR. Thoracic aorta: motion artifact reduction with retrospective and prospective electrocardiography-assisted multi-detector row CT. Radiology. 2002;222(1):271\u20137.","journal-title":"Radiology"},{"issue":"4","key":"1849_CR9","doi-asserted-by":"publisher","first-page":"W153","DOI":"10.2214\/AJR.19.21456","volume":"213","author":"T Takayanagi","year":"2019","unstructured":"Takayanagi T, Suzuki S, Katada Y, Ishikawa T, Fukui R, Yamamoto Y, et al. Comparison of motion artifacts on CT images obtained in the ultrafast scan mode and conventional scan mode for unconscious patients in the emergency department. AJR Am J Roentgenol. 2019;213(4):W153\u201361.","journal-title":"AJR Am J Roentgenol"},{"issue":"8","key":"1849_CR10","doi-asserted-by":"publisher","first-page":"950","DOI":"10.1177\/0284185114544242","volume":"56","author":"M Beeres","year":"2015","unstructured":"Beeres M, Wichmann JL, Paul J, Mbalisike E, Elsabaie M, Vogl TJ, et al. CT chest and gantry rotation time: does the rotation time influence image quality? Acta Radiol. 2015;56(8):950\u20134.","journal-title":"Acta Radiol"},{"issue":"1","key":"1849_CR11","doi-asserted-by":"publisher","first-page":"140","DOI":"10.2214\/AJR.07.3019","volume":"191","author":"GM Israel","year":"2008","unstructured":"Israel GM, Herlihy S, Rubinowitz AN, Cornfeld D, Brink J. Does a combination of dose modulation with fast gantry rotation time limit CT image quality? AJR Am J Roentgenol. 2008;191(1):140\u20134.","journal-title":"AJR Am J Roentgenol"},{"issue":"4","key":"1849_CR12","doi-asserted-by":"publisher","first-page":"423","DOI":"10.1016\/j.jacr.2014.12.017","volume":"12","author":"FN Ranallo","year":"2015","unstructured":"Ranallo FN, Szczykutowicz T. The correct selection of pitch for optimal CT scanning: avoiding common misconceptions. J Am Coll Radiol. 2015;12(4):423\u20134.","journal-title":"J Am Coll Radiol"},{"issue":"4","key":"1849_CR13","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1007\/s11604-018-0726-3","volume":"36","author":"K Yasaka","year":"2018","unstructured":"Yasaka K, Akai H, Kunimatsu A, Kiryu S, Abe O. Deep learning with convolutional neural network in radiology. Jpn J Radiol. 2018;36(4):257\u201372.","journal-title":"Jpn J Radiol"},{"issue":"7","key":"1849_CR14","doi-asserted-by":"publisher","first-page":"2113","DOI":"10.1148\/rg.2017170077","volume":"37","author":"G Chartrand","year":"2017","unstructured":"Chartrand G, Cheng PM, Vorontsov E, Drozdzal M, Turcotte S, Pal CJ, et al. Deep learning: a primer for radiologists. Radiographics. 2017;37(7):2113\u201331.","journal-title":"Radiographics"},{"issue":"1150","key":"1849_CR15","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.20220685","volume":"96","author":"K Yasaka","year":"2023","unstructured":"Yasaka K, Hatano S, Mizuki M, Okimoto N, Kubo T, Shibata E, et al. Effects of deep learning on radiologists\u2019 and radiology residents\u2019 performance in identifying esophageal cancer on CT. Br J Radiol. 2023;96(1150): 20220685.","journal-title":"Br J Radiol"},{"issue":"1","key":"1849_CR16","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1148\/radiol.2018180901","volume":"290","author":"D Ueda","year":"2019","unstructured":"Ueda D, Yamamoto A, Nishimori M, Shimono T, Doishita S, Shimazaki A, et al. Deep learning for MR angiography: automated detection of cerebral aneurysms. Radiology. 2019;290(1):187\u201394.","journal-title":"Radiology"},{"issue":"3","key":"1849_CR17","doi-asserted-by":"publisher","first-page":"887","DOI":"10.1148\/radiol.2017170706","volume":"286","author":"K Yasaka","year":"2018","unstructured":"Yasaka K, Akai H, Abe O, Kiryu S. Deep learning with convolutional neural network for differentiation of liver masses at dynamic contrast-enhanced CT: a preliminary study. Radiology. 2018;286(3):887\u201396.","journal-title":"Radiology"},{"issue":"6","key":"1849_CR18","doi-asserted-by":"publisher","DOI":"10.1148\/rg.220133","volume":"43","author":"S Kiryu","year":"2023","unstructured":"Kiryu S, Akai H, Yasaka K, Tajima T, Kunimatsu A, Yoshioka N, et al. Clinical impact of deep learning reconstruction in MRI. Radiographics. 2023;43(6): e220133.","journal-title":"Radiographics"},{"issue":"5","key":"1849_CR19","doi-asserted-by":"publisher","first-page":"2921","DOI":"10.1007\/s00330-021-08438-z","volume":"32","author":"JA van Stiphout","year":"2022","unstructured":"van Stiphout JA, Driessen J, Koetzier LR, Ruules LB, Willemink MJ, Heemskerk JWT, et al. The effect of deep learning reconstruction on abdominal CT densitometry and image quality: a systematic review and meta-analysis. Eur Radiol. 2022;32(5):2921\u20139.","journal-title":"Eur Radiol"},{"issue":"4","key":"1849_CR20","doi-asserted-by":"publisher","first-page":"1280","DOI":"10.1007\/s00261-023-03834-z","volume":"48","author":"N Okimoto","year":"2023","unstructured":"Okimoto N, Yasaka K, Kaiume M, Kanemaru N, Suzuki Y, Abe O. Improving detection performance of hepatocellular carcinoma and interobserver agreement for liver imaging reporting and data system on CT using deep learning reconstruction. Abdom Radiol (NY). 2023;48(4):1280\u20139.","journal-title":"Abdom Radiol (NY)"},{"key":"1849_CR21","doi-asserted-by":"publisher","DOI":"10.1007\/s00234-023-03251-5","author":"N Okimoto","year":"2023","unstructured":"Okimoto N, Yasaka K, Fujita N, Watanabe Y, Kanzawa J, Abe O. Deep learning reconstruction for improving the visualization of acute brain infarct on computed tomography. Neuroradiology. 2023. https:\/\/doi.org\/10.1007\/s00234-023-03251-5.","journal-title":"Neuroradiology"},{"key":"1849_CR22","doi-asserted-by":"publisher","DOI":"10.1177\/08465371231203508","author":"N Fujita","year":"2023","unstructured":"Fujita N, Yasaka K, Watanabe Y, Okimoto N, Konishiike M, Abe O. Detection of vertebral mass and diagnosis of spinal cord compression in computed tomography with deep learning reconstruction: comparison with hybrid iterative reconstruction. Can Assoc Radiol J. 2023. https:\/\/doi.org\/10.1177\/08465371231203508.","journal-title":"Can Assoc Radiol J"},{"issue":"9","key":"1849_CR23","doi-asserted-by":"publisher","first-page":"1085","DOI":"10.1177\/0284185116684675","volume":"58","author":"K Yasaka","year":"2017","unstructured":"Yasaka K, Furuta T, Kubo T, Maeda E, Katsura M, Sato J, et al. Full and hybrid iterative reconstruction to reduce artifacts in abdominal CT for patients scanned without arm elevation. Acta Radiol. 2017;58(9):1085\u201393.","journal-title":"Acta Radiol"},{"issue":"2","key":"1849_CR24","doi-asserted-by":"publisher","first-page":"462","DOI":"10.1148\/radiol.2020201911","volume":"297","author":"M Yanagawa","year":"2020","unstructured":"Yanagawa M, Tsubamoto M, Satoh Y, Hata A, Miyata T, Yoshida Y, et al. Lung adenocarcinoma at CT with 0.25-mm section thickness and a 2048 matrix: high-spatial-resolution imaging for predicting invasiveness. Radiology. 2020;297(2):462\u201371.","journal-title":"Radiology"},{"issue":"12","key":"1849_CR25","doi-asserted-by":"publisher","first-page":"8488","DOI":"10.1007\/s00330-023-09888-3","volume":"33","author":"Y Nagayama","year":"2023","unstructured":"Nagayama Y, Emoto T, Kato Y, Kidoh M, Oda S, Sakabe D, et al. Improving image quality with super-resolution deep-learning-based reconstruction in coronary CT angiography. Eur Radiol. 2023;33(12):8488\u2013500.","journal-title":"Eur Radiol"},{"issue":"4","key":"1849_CR26","volume":"5","author":"M Takafuji","year":"2023","unstructured":"Takafuji M, Kitagawa K, Mizutani S, Hamaguchi A, Kisou R, Iio K, et al. Super-resolution deep learning reconstruction for improved image quality of coronary CT angiography. Radiol: Cardiothoracic Imag. 2023;5(4): e230085.","journal-title":"Radiol: Cardiothoracic Imag"},{"key":"1849_CR27","doi-asserted-by":"publisher","DOI":"10.1007\/s11604-025-01760-2","author":"M Takafuji","year":"2025","unstructured":"Takafuji M, Kitagawa K, Mizutani S, Hamaguchi A, Kisou R, Sasaki K, et al. Super-resolution deep learning reconstruction for improved quality of myocardial CT late enhancement. Jpn J Radiol. 2025. https:\/\/doi.org\/10.1007\/s11604-025-01760-2.","journal-title":"Jpn J Radiol"},{"key":"1849_CR28","doi-asserted-by":"crossref","unstructured":"Lee TC, Zhou J, Yu Z, Cai L. 2022 Deep learning enabled wide-coverage high-resolution cardiac CT. Medical Imaging 2022 Physics of Medical Imaging. 12031:678","DOI":"10.1117\/12.2611817"},{"issue":"10","key":"1849_CR29","doi-asserted-by":"publisher","first-page":"5322","DOI":"10.1007\/s00330-019-06183-y","volume":"29","author":"F Tatsugami","year":"2019","unstructured":"Tatsugami F, Higaki T, Nakamura Y, Yu Z, Zhou J, Lu Y, et al. Deep learning-based image restoration algorithm for coronary CT angiography. Eur Radiol. 2019;29(10):5322\u20139.","journal-title":"Eur Radiol"},{"issue":"7","key":"1849_CR30","doi-asserted-by":"publisher","first-page":"1063","DOI":"10.1016\/j.ejrad.2014.03.032","volume":"83","author":"K Yasaka","year":"2014","unstructured":"Yasaka K, Katsura M, Akahane M, Sato J, Matsuda I, Ohtomo K. Dose-reduced CT with model-based iterative reconstruction in evaluations of hepatic steatosis: how low can we go? Eur J Radiol. 2014;83(7):1063\u20138.","journal-title":"Eur J Radiol"},{"issue":"5","key":"1849_CR31","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1007\/s11604-016-0529-3","volume":"34","author":"K Yasaka","year":"2016","unstructured":"Yasaka K, Katsura M, Sato J, Akahane M, Matsuda I, Ohtomo K. Comparison of new and conventional versions of model-based iterative reconstruction in reduced-dose computed tomography for diagnosis of hepatic steatosis. Jpn J Radiol. 2016;34(5):339\u201348.","journal-title":"Jpn J Radiol"},{"issue":"5","key":"1849_CR32","doi-asserted-by":"publisher","first-page":"796","DOI":"10.1097\/RCT.0000000000001479","volume":"47","author":"R Yamakuni","year":"2023","unstructured":"Yamakuni R, Sekino H, Saito M, Kakamu T, Takahashi K, Hara J, et al. Prediction of anemia from cerebral venous sinus attenuation on deep-learning reconstructed brain computed tomography images. J Comput Assist Tomogr. 2023;47(5):796\u2013805.","journal-title":"J Comput Assist Tomogr"}],"container-title":["Japanese Journal of Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11604-025-01849-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11604-025-01849-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11604-025-01849-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,26]],"date-time":"2025-11-26T02:34:01Z","timestamp":1764124441000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11604-025-01849-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,9]]},"references-count":32,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2025,12]]}},"alternative-id":["1849"],"URL":"https:\/\/doi.org\/10.1007\/s11604-025-01849-8","relation":{},"ISSN":["1867-1071","1867-108X"],"issn-type":[{"value":"1867-1071","type":"print"},{"value":"1867-108X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,9]]},"assertion":[{"value":"25 May 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 July 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 August 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors have no relevant financial or non-financial interests to disclose.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This study was performed in line with the principles of the Declaration of Helsinki. Approval was granted by our Institutional Review Board.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"Requirement for obtaining written informed consent was waived by the Institutional Review Board due to the retrospective nature of this study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}}]}}