{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T22:45:23Z","timestamp":1788389123167,"version":"build-2803163510"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T00:00:00Z","timestamp":1772755200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T00:00:00Z","timestamp":1772755200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Jpn J Radiol"],"published-print":{"date-parts":[[2026,7]]},"DOI":"10.1007\/s11604-026-01964-0","type":"journal-article","created":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T04:52:39Z","timestamp":1772772759000},"page":"1159-1167","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["High-resolution chest CT using 1024-matrix reconstruction: phantom and clinical evaluation of image quality and post-processing capability"],"prefix":"10.1007","volume":"44","author":[{"given":"Kana","family":"Hayashi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8252-1947","authenticated-orcid":false,"given":"Yoshiyuki","family":"Ozawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hirotsugu","family":"Ohkubo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katsuhiro","family":"Okuda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroshi","family":"Kunitomo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seita","family":"Watanabe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katsuya","family":"Kato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akio","family":"Hiwatashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,3,6]]},"reference":[{"key":"1964_CR1","doi-asserted-by":"publisher","first-page":"917","DOI":"10.1148\/radiographics.12.5.1529134","volume":"12","author":"HL Corcoran","year":"1992","unstructured":"Corcoran HL, Renner WR, Milstein MJ. Review of high-resolution CT of the lung. Radiographics. 1992;12:917\u201339.","journal-title":"Radiographics"},{"key":"1964_CR2","doi-asserted-by":"publisher","first-page":"501","DOI":"10.2214\/ajr.177.3.1770501","volume":"177","author":"EA Kazerooni","year":"2001","unstructured":"Kazerooni EA. High-resolution CT of the lungs. AJR Am J Roentgenol. 2001;177:501\u201319.","journal-title":"AJR Am J Roentgenol"},{"key":"1964_CR3","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1148\/radiology.163.2.3562834","volume":"163","author":"JR Mayo","year":"1987","unstructured":"Mayo JR, Webb WR, Gould R, Stein MG, Bass I, Gamsu G, et al. High-resolution CT of the lungs: an optimal approach. Radiology. 1987;163:507\u201310.","journal-title":"Radiology"},{"key":"1964_CR4","doi-asserted-by":"publisher","first-page":"869","DOI":"10.1016\/j.acra.2017.11.017","volume":"25","author":"A Hata","year":"2018","unstructured":"Hata A, Yanagawa M, Honda O, Kikuchi N, Miyata T, Tsukagoshi S, et al. Effect of matrix size on the image quality of ultra-high-resolution CT of the lung: comparison of 512 \u00d7 512, 1024 \u00d7 1024, and 2048 \u00d7 2048. Acad Radiol. 2018;25:869\u201376.","journal-title":"Acad Radiol"},{"key":"1964_CR5","doi-asserted-by":"publisher","first-page":"5060","DOI":"10.1007\/s00330-018-5491-2","volume":"28","author":"M Yanagawa","year":"2018","unstructured":"Yanagawa M, Hata A, Honda O, Kikuchi N, Miyata T, Uranishi A, et al. Subjective and objective comparisons of image quality between ultra-high-resolution CT and conventional area detector CT in phantoms and cadaveric human lungs. Eur Radiol. 2018;28:5060\u20138.","journal-title":"Eur Radiol"},{"key":"1964_CR6","doi-asserted-by":"publisher","first-page":"2552","DOI":"10.1007\/s00330-019-06635-5","volume":"30","author":"LJ Oostveen","year":"2020","unstructured":"Oostveen LJ, Boedeker KL, Brink M, Prokop M, de Lange F, Sechopoulos I. Physical evaluation of an ultra-high-resolution CT scanner. Eur Radiol. 2020;30:2552\u201360.","journal-title":"Eur Radiol"},{"key":"1964_CR7","doi-asserted-by":"publisher","first-page":"2283","DOI":"10.2147\/COPD.S223605","volume":"14","author":"Y Xu","year":"2019","unstructured":"Xu Y, Yamashiro T, Moriya H, Muramatsu S, Murayama S. Quantitative emphysema measurement on ultra-high-resolution CT scans. Int J Chron Obstruct Pulmon Dis. 2019;14:2283\u201390.","journal-title":"Int J Chron Obstruct Pulmon Dis"},{"key":"1964_CR8","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1016\/j.ejrad.2018.04.004","volume":"103","author":"O Honda","year":"2018","unstructured":"Honda O, Yanagawa M, Hata A, Kikuchi N, Miyata T, Tsukagoshi S, et al. Influence of gantry rotation time and scan mode on image quality in ultra-high-resolution CT system. Eur J Radiol. 2018;103:71\u20135.","journal-title":"Eur J Radiol"},{"key":"1964_CR9","doi-asserted-by":"publisher","first-page":"15119","DOI":"10.1038\/s41598-021-94596-5","volume":"11","author":"A Hata","year":"2021","unstructured":"Hata A, Yanagawa M, Tsubamoto M, Doi S, Yoshida Y, Miyata T, et al. Detectability of pulmonary ossifications in fibrotic lung on ultra-high-resolution CT using 2048 matrix size and 0.25-mm slice thickness. Sci Rep. 2021;11:15119.","journal-title":"Sci Rep"},{"key":"1964_CR10","doi-asserted-by":"publisher","first-page":"884","DOI":"10.1007\/s11604-020-00972-y","volume":"38","author":"T Adachi","year":"2020","unstructured":"Adachi T, Machida H, Nishikawa M, Arai T, Kariyasu T, Koyanagi M, et al. Improved delineation of CT virtual bronchoscopy by ultrahigh-resolution CT: comparison among different reconstruction parameters. Jpn J Radiol. 2020;38:884\u20139.","journal-title":"Jpn J Radiol"},{"key":"1964_CR11","doi-asserted-by":"publisher","first-page":"953","DOI":"10.1007\/s11604-020-01000-9","volume":"38","author":"Y Morita","year":"2020","unstructured":"Morita Y, Yamashiro T, Tsuchiya N, Tsubakimoto M, Murayama S. Automatic bronchial segmentation on ultra-HRCT scans: advantage of the 1024-matrix size with 0.25-mm slice thickness reconstruction. Jpn J Radiol. 2020;38:953\u20139.","journal-title":"Jpn J Radiol"},{"key":"1964_CR12","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1186\/s41747-019-0135-0","volume":"4","author":"R Inai","year":"2020","unstructured":"Inai R, Nakahara R, Morimitsu Y, Akagi N, Marukawa Y, Matsushita T, et al. Bone microarchitectural analysis using ultra-high-resolution CT in tiger vertebra and human tibia. Eur Radiol Exp. 2020;4:4.","journal-title":"Eur Radiol Exp"},{"key":"1964_CR13","doi-asserted-by":"publisher","first-page":"e0234644","DOI":"10.1371\/journal.pone.0234644","volume":"15","author":"A Euler","year":"2020","unstructured":"Euler A, Martini K, Baessler B, Eberhard M, Schoeck F, Alkadhi H, et al. 1024-pixel image matrix for chest CT\u2014impact on image quality of bronchial structures in phantoms and patients. PLoS ONE. 2020;15:e0234644.","journal-title":"PLoS ONE"},{"key":"1964_CR14","doi-asserted-by":"publisher","first-page":"1662","DOI":"10.3390\/diagnostics12071662","volume":"12","author":"BD Balmer","year":"2022","unstructured":"Balmer BD, Bl\u00fcthgen C, B\u00e4ssler B, Martini K, Huber FA, Ruby L, et al. Influence of CT image matrix size and Kernel type on the assessment of HRCT in patients with SSC-ILD. Diagnostics (Basel). 2022;12:1662.","journal-title":"Diagnostics (Basel)"},{"key":"1964_CR15","doi-asserted-by":"publisher","first-page":"314","DOI":"10.1118\/1.4903899","volume":"42","author":"E Samei","year":"2015","unstructured":"Samei E, Richard S. Assessment of the dose reduction potential of a model-based iterative reconstruction algorithm using a task-based performance metrology. Med Phys. 2015;42:314\u201323.","journal-title":"Med Phys"},{"key":"1964_CR16","doi-asserted-by":"publisher","first-page":"4115","DOI":"10.1118\/1.4725171","volume":"39","author":"S Richard","year":"2012","unstructured":"Richard S, Husarik DB, Yadava G, Murphy SN, Samei E. Towards task-based assessment of CT performance: System and object MTF across different reconstruction algorithms. Med Phys. 2012;39:4115\u201322.","journal-title":"Med Phys"},{"key":"1964_CR17","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1016\/j.ejmp.2017.01.001","volume":"33","author":"T Takata","year":"2017","unstructured":"Takata T, Ichikawa K, Mitsui W, Hayashi H, Minehiro K, Sakuta K, et al. Object shape dependency of in-plane resolution for iterative reconstruction of computed tomography. Phys Med. 2017;33:146\u201351.","journal-title":"Phys Med"},{"key":"1964_CR18","doi-asserted-by":"publisher","first-page":"992","DOI":"10.1016\/j.ejmp.2016.07.003","volume":"32","author":"A Urikura","year":"2016","unstructured":"Urikura A, Hara T, Ichikawa K, Nishimaru H, Hoshino T, Yoshida T, et al. Objective assessment of low-contrast computed tomography images with iterative reconstruction. Phys Med. 2016;32:992\u20138.","journal-title":"Phys Med"},{"key":"1964_CR19","doi-asserted-by":"publisher","first-page":"4027","DOI":"10.1088\/0031-9155\/52\/14\/002","volume":"52","author":"KL Boedeker","year":"2007","unstructured":"Boedeker KL, Cooper VN, McNitt-Gray MF. Application of the noise power spectrum in modern diagnostic MDCT: part I. Measurement of noise power spectra and noise equivalent quanta. Phys Med Biol. 2007;52:4027\u201346.","journal-title":"Phys Med Biol"},{"key":"1964_CR20","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1016\/j.ejmp.2020.05.002","volume":"74","author":"K Sugisawa","year":"2020","unstructured":"Sugisawa K, Ichikawa K, Urikura A, Minamishima K, Masuda S, Hoshino T, et al. Spatial resolution compensation by adjusting the reconstruction kernels for iterative reconstruction images of computed tomography. Phys Med. 2020;74:47\u201355.","journal-title":"Phys Med"},{"key":"1964_CR21","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1002\/acm2.12597","volume":"20","author":"H Kawashima","year":"2019","unstructured":"Kawashima H, Ichikawa K, Matsubara K, Nagata H, Akata T, Kobayashi S. Quality evaluation of image-based iterative reconstruction for CT: comparison with hybrid iterative reconstruction. J Appl Clin Med Phys. 2019;20:199\u2013205.","journal-title":"J Appl Clin Med Phys"},{"key":"1964_CR22","doi-asserted-by":"publisher","first-page":"565","DOI":"10.1088\/0031-9155\/32\/5\/003","volume":"32","author":"MF Kijewski","year":"1987","unstructured":"Kijewski MF, Judy PF. The noise power spectrum of CT images. Phys Med Biol. 1987;32:565\u201375.","journal-title":"Phys Med Biol"},{"key":"1964_CR23","doi-asserted-by":"publisher","first-page":"e44","DOI":"10.1164\/rccm.201807-1255ST","volume":"198","author":"G Raghu","year":"2018","unstructured":"Raghu G, Remy-Jardin M, Myers JL, Richeldi L, Ryerson CJ, Lederer DJ, et al. Diagnosis of idiopathic pulmonary fibrosis. An Official ATS\/ERS\/JRS\/ALAT clinical practice guideline. Am J Respir Crit Care Med. 2018;198:e44\u201368.","journal-title":"Am J Respir Crit Care Med"},{"key":"1964_CR24","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1016\/j.ejrad.2012.12.028","volume":"83","author":"M Nishino","year":"2014","unstructured":"Nishino M, Itoh H, Hatabu H. A practical approach to high-resolution CT of diffuse lung disease. Eur J Radiol. 2014;83:6\u201319.","journal-title":"Eur J Radiol"},{"key":"1964_CR25","doi-asserted-by":"publisher","first-page":"226","DOI":"10.1136\/thx.2010.137190","volume":"66","author":"C Tcherakian","year":"2011","unstructured":"Tcherakian C, Cottin V, Brillet PY, Freynet O, Naggara N, Carton Z, et al. Progression of idiopathic pulmonary fibrosis: lessons from asymmetrical disease. Thorax. 2011;66:226\u201331.","journal-title":"Thorax"},{"key":"1964_CR26","doi-asserted-by":"publisher","first-page":"109033","DOI":"10.1016\/j.ejrad.2020.109033","volume":"128","author":"M Tsubamoto","year":"2020","unstructured":"Tsubamoto M, Hata A, Yanagawa M, Honda O, Miyata T, Yoshida Y, et al. Ultra high-resolution computed tomography with 1024-matrix: comparison with 512-matrix for the evaluation of pulmonary nodules. Eur J Radiol. 2020;128:109033.","journal-title":"Eur J Radiol"},{"key":"1964_CR27","doi-asserted-by":"publisher","first-page":"52","DOI":"10.25259\/JCIS_143_2021","volume":"11","author":"A Inoue","year":"2021","unstructured":"Inoue A, Johnson TF, Voss BA, Lee YS, Leng S, Koo CW, et al. A pilot study to estimate the impact of high matrix image reconstruction on chest computed tomography. J Clin Imaging Sci. 2021;11:52.","journal-title":"J Clin Imaging Sci"},{"key":"1964_CR28","doi-asserted-by":"publisher","first-page":"1373","DOI":"10.1007\/s11604-023-01470-7","volume":"41","author":"N Hamabuchi","year":"2023","unstructured":"Hamabuchi N, Ohno Y, Kimata H, Ito Y, Fujii K, Akino N, et al. Effectiveness of deep learning reconstruction on standard to ultra-low-dose high-definition chest CT images. Jpn J Radiol. 2023;41:1373\u201388.","journal-title":"Jpn J Radiol"},{"key":"1964_CR29","doi-asserted-by":"publisher","first-page":"1895","DOI":"10.1007\/s00330-023-10174-5","volume":"34","author":"V Van Ballaer","year":"2024","unstructured":"Van Ballaer V, Dubbeldam A, Muscogiuri E, Cockmartin L, Bosmans H, Coudyzer W, et al. Impact of ultra-high-resolution imaging of the lungs on perceived diagnostic image quality using photon-counting CT. Eur Radiol. 2024;34:1895\u2013904.","journal-title":"Eur Radiol"}],"container-title":["Japanese Journal of Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11604-026-01964-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11604-026-01964-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11604-026-01964-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,29]],"date-time":"2026-06-29T07:16:18Z","timestamp":1782717378000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11604-026-01964-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,6]]},"references-count":29,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2026,7]]}},"alternative-id":["1964"],"URL":"https:\/\/doi.org\/10.1007\/s11604-026-01964-0","relation":{},"ISSN":["1867-1071","1867-108X"],"issn-type":[{"value":"1867-1071","type":"print"},{"value":"1867-108X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,6]]},"assertion":[{"value":"3 January 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 February 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 March 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no relationships with any companies for this study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"This study was approved by the institutional review board of Nagoya City University Hospital.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"Informed consent was waived for review of patient records and images.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}