{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,17]],"date-time":"2026-10-17T19:45:36Z","timestamp":1792266336181,"version":"4.4.0"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,10,17]],"date-time":"2026-10-17T00:00:00Z","timestamp":1792195200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,10,17]],"date-time":"2026-10-17T00:00:00Z","timestamp":1792195200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Jpn J Radiol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Automated computed tomography perfusion (CTP) analysis plays a key role in triaging acute ischemic stroke (AIS). This study aimed to evaluate the agreement of PMAneo compared with RAPID in a multicenter setting.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>We retrospectively reviewed 99 patients with anterior circulation AIS from three stroke centers using four different CT scanners. CTP data were processed using both PMAneo and RAPID. Volumetric agreement for ischemic core volume and Tmax\u2009&gt;\u20096\u00a0s volume was assessed using intraclass correlation coefficients (ICCs) and Bland\u2013Altman analysis. Multivariable regression analysis was performed to identify factors associated with volume discrepancies. EVT imaging eligibility was evaluated according to the DEFUSE 3 criteria (ischemic core volume\u2009&lt;\u200970\u00a0mL, mismatch ratio\u2009\u2265\u20091.8, and absolute mismatch volume\u2009\u2265\u200915\u00a0mL), using RAPID as the comparator.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Ischemic core volumes showed excellent agreement between the two platforms (ICC\u2009=\u20090.881, 95% CI 0.827\u20130.918), and Tmax\u2009&gt;\u20096\u00a0s volumes showed good agreement (ICC\u2009=\u20090.761, 95% CI 0.283\u20130.896), whereas mismatch volumes showed moderate agreement (ICC\u2009=\u20090.661, 95% CI 0.146\u20130.844). For the ischemic core threshold (&lt;\u200970\u00a0mL), PMAneo demonstrated 100% (95% CI 96\u2013100%) relative sensitivity and 67% (95% CI 38\u201388%) relative specificity. For the full DEFUSE 3 criteria, the relative sensitivity and specificity were 81% (95% CI 70\u201389%) and 84% (95% CI 66\u201395%), respectively. Bland\u2013Altman analysis demonstrated proportional bias, with PMAneo underestimating volumes relative to RAPID as lesion size increased. Basal ganglia involvement and imaging site were significantly associated with these volume differences (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>PMAneo showed high volumetric agreement and comparable DEFUSE 3 imaging eligibility to RAPID, suggesting it is a reliable alternative for automated CTP analysis. Although proportional bias and potential diagnostic discrepancies were observed in borderline cases near clinically relevant thresholds, PMAneo may facilitate broader access to automated CTP analysis.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s11604-026-02095-2","type":"journal-article","created":{"date-parts":[[2026,10,17]],"date-time":"2026-10-17T08:04:42Z","timestamp":1792224282000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Comparison of PMAneo and RAPID in acute ischemic stroke: agreement in CT perfusion analysis and DEFUSE 3 imaging eligibility"],"prefix":"10.1007","author":[{"given":"Yohei","family":"Ikebe","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keiji","family":"Noutomi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kazuma","family":"Ishibashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mari","family":"Anzai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manabu","family":"Shirakawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshiyuki","family":"Onda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manabu","family":"Inoue","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bunya","family":"Takahashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryosuke","family":"Shimura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuki","family":"Takano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Motoma","family":"Kanaya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Koki","family":"Iura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroyuki","family":"Kameda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Taisuke","family":"Harada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yukie","family":"Shimizu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Noriyuki","family":"Fujima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shinichi","family":"Yoshimura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5351-9242","authenticated-orcid":false,"given":"Kohsuke","family":"Kudo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,10,17]]},"reference":[{"issue":"2","key":"2095_CR1","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1177\/17474930241308142","volume":"20","author":"VL Feigin","year":"2025","unstructured":"Feigin VL, Brainin M, Norrving B, Martins SO, Pandian J, Lindsay P, et al. World Stroke Organization: global stroke fact sheet 2025. Int J Stroke. 2025;20(2):132\u201344.","journal-title":"Int J Stroke"},{"issue":"8","key":"2095_CR2","doi-asserted-by":"publisher","first-page":"708","DOI":"10.1056\/NEJMoa1713973","volume":"378","author":"GW Albers","year":"2018","unstructured":"Albers GW, Marks MP, Kemp S, Christensen S, Tsai JP, Ortega-Gutierrez S, et al. Thrombectomy for stroke at 6 to 16 hours with selection by perfusion imaging. N Engl J Med. 2018;378(8):708\u201318.","journal-title":"N Engl J Med"},{"issue":"1","key":"2095_CR3","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1056\/NEJMoa1706442","volume":"378","author":"RG Nogueira","year":"2018","unstructured":"Nogueira RG, Jadhav AP, Haussen DC, Bonafe A, Budzik RF, Bhuva P, et al. Thrombectomy 6 to 24 hours after stroke with a mismatch between deficit and infarct. N Engl J Med. 2018;378(1):11\u201321.","journal-title":"N Engl J Med"},{"issue":"12","key":"2095_CR4","doi-asserted-by":"publisher","first-page":"e344","DOI":"10.1161\/STR.0000000000000211","volume":"50","author":"WJ Powers","year":"2019","unstructured":"Powers WJ, Rabinstein AA, Ackerson T, Adeoye OM, Bambakidis NC, Becker K, et al. Guidelines for the early management of patients with acute ischemic stroke: 2019 update to the 2018 guidelines for the early management of acute ischemic stroke: a guideline for healthcare professionals from the American heart association\/American stroke association. Stroke. 2019;50(12):e344\u2013418.","journal-title":"Stroke"},{"issue":"1","key":"2095_CR5","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1148\/radiol.12112618","volume":"267","author":"K Kudo","year":"2013","unstructured":"Kudo K, Christensen S, Sasaki M, \u00d8stergaard L, Shirato H, Ogasawara K, et al. Accuracy and reliability assessment of CT and MR perfusion analysis software using a digital phantom. Radiology. 2013;267(1):201\u201311.","journal-title":"Radiology"},{"issue":"1","key":"2095_CR6","doi-asserted-by":"publisher","first-page":"200","DOI":"10.1148\/radiol.254082000","volume":"254","author":"K Kudo","year":"2010","unstructured":"Kudo K, Sasaki M, Yamada K, Momoshima S, Utsunomiya H, Shirato H, et al. Differences in CT perfusion maps generated by different commercial software: quantitative analysis by using identical source data of acute stroke patients. Radiology. 2010;254(1):200\u20139.","journal-title":"Radiology"},{"issue":"20","key":"2095_CR7","doi-asserted-by":"publisher","first-page":"888","DOI":"10.1212\/WNL.0000000000008481","volume":"93","author":"A Vagal","year":"2019","unstructured":"Vagal A, Wintermark M, Nael K, Bivard A, Parsons M, Grossman AW, et al. Automated CT perfusion imaging for acute ischemic stroke: Pearls and pitfalls for real-world use. Neurology. 2019;93(20):888\u201398.","journal-title":"Neurology"},{"issue":"10","key":"2095_CR8","doi-asserted-by":"publisher","first-page":"1028","DOI":"10.1136\/neurintsurg-2020-015827","volume":"12","author":"G Bathla","year":"2020","unstructured":"Bathla G, Ortega-Gutierrez S, Klotz E, Juergens M, Zevallos CB, Ansari S, et al. Comparing the outcomes of two independent computed tomography perfusion softwares and their impact on therapeutic decisions in acute ischemic stroke. J Neurointerv Surg. 2020;12(10):1028\u201332.","journal-title":"J Neurointerv Surg"},{"issue":"10","key":"2095_CR9","doi-asserted-by":"publisher","DOI":"10.1016\/j.jstrokecerebrovasdis.2022.106702","volume":"31","author":"DH Mallon","year":"2022","unstructured":"Mallon DH, Taylor EJR, Vittay OI, Sheeka A, Doig D, Lobotesis K. Comparison of automated ASPECTS, large vessel occlusion detection and CTP analysis provided by Brainomix and RapidAI in patients with suspected ischaemic stroke. J Stroke Cerebrovasc Dis. 2022;31(10):106702.","journal-title":"J Stroke Cerebrovasc Dis"},{"issue":"2","key":"2095_CR10","doi-asserted-by":"publisher","first-page":"206","DOI":"10.3174\/ajnr.A6395","volume":"41","author":"RA Rava","year":"2020","unstructured":"Rava RA, Snyder KV, Mokin M, Waqas M, Allman AB, Senko JL, et al. Assessment of a Bayesian Vitrea CT perfusion analysis to predict final infarct and penumbra volumes in patients with acute ischemic stroke: a comparison with RAPID. AJNR Am J Neuroradiol. 2020;41(2):206\u201312.","journal-title":"AJNR Am J Neuroradiol"},{"issue":"12","key":"2095_CR11","doi-asserted-by":"publisher","first-page":"1249","DOI":"10.1136\/neurintsurg-2019-014822","volume":"11","author":"MS Koopman","year":"2019","unstructured":"Koopman MS, Berkhemer OA, Geuskens R, Emmer BJ, van Walderveen MAA, Jenniskens SFM, et al. Comparison of three commonly used CT perfusion software packages in patients with acute ischemic stroke. J Neurointerv Surg. 2019;11(12):1249\u201356.","journal-title":"J Neurointerv Surg"},{"issue":"12","key":"2095_CR12","doi-asserted-by":"publisher","DOI":"10.1016\/j.jstrokecerebrovasdis.2019.104392","volume":"28","author":"Y Xiong","year":"2019","unstructured":"Xiong Y, Huang CC, Fisher M, Hackney DB, Bhadelia RA, Selim MH. Comparison of automated CT perfusion softwares in evaluation of acute ischemic stroke. J Stroke Cerebrovasc Dis. 2019;28(12):104392.","journal-title":"J Stroke Cerebrovasc Dis"},{"issue":"5","key":"2095_CR13","doi-asserted-by":"publisher","first-page":"848","DOI":"10.1002\/ana.26748","volume":"94","author":"L Pisani","year":"2023","unstructured":"Pisani L, Haussen DC, Mohammaden M, Perry da Camara C, Jillella DV, Rodrigues GM, et al. Comparison of CT perfusion software packages for thrombectomy eligibility. Ann Neurol. 2023;94(5):848\u201355.","journal-title":"Ann Neurol"},{"key":"2095_CR14","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2022.110500","volume":"156","author":"Q Lu","year":"2022","unstructured":"Lu Q, Fu J, Lv K, Han Y, Pan Y, Xu Y, et al. Agreement of three CT perfusion software packages in patients with acute ischemic stroke: a comparison with RAPID. Eur J Radiol. 2022;156:110500.","journal-title":"Eur J Radiol"},{"issue":"7","key":"2095_CR15","doi-asserted-by":"publisher","first-page":"863","DOI":"10.3174\/ajnr.A8196","volume":"45","author":"S Bushnaq","year":"2024","unstructured":"Bushnaq S, Hassan AE, Delora A, Kerro A, Datta A, Ezzeldin R, et al. A comparison of CT perfusion output of RapidAI and Viz.ai software in the evaluation of acute ischemic stroke. AJNR Am J Neuroradiol. 2024;45(7):863\u201370.","journal-title":"AJNR Am J Neuroradiol"},{"key":"2095_CR16","doi-asserted-by":"publisher","DOI":"10.3389\/fnins.2024.1398889","volume":"18","author":"N Kim","year":"2024","unstructured":"Kim N, Ha SY, Park GH, Park JH, Kim D, Sunwoo L, et al. Comparison of two automated CT perfusion software packages in patients with ischemic stroke presenting within 24\u2009h of onset. Front Neurosci. 2024;18:1398889.","journal-title":"Front Neurosci"},{"issue":"7","key":"2095_CR17","doi-asserted-by":"publisher","DOI":"10.1016\/j.jstrokecerebrovasdis.2024.107750","volume":"33","author":"BT Alwood","year":"2024","unstructured":"Alwood BT, Meyer DM, Ionita C, Snyder KV, Santos R, Perrotta L, et al. Multicenter comparison using two AI stroke CT perfusion software packages for determining thrombectomy eligibility. J Stroke Cerebrovasc Dis. 2024;33(7):107750.","journal-title":"J Stroke Cerebrovasc Dis"},{"issue":"10","key":"2095_CR18","doi-asserted-by":"publisher","first-page":"1780","DOI":"10.1177\/0271678X15610586","volume":"36","author":"CW Cereda","year":"2016","unstructured":"Cereda CW, Christensen S, Campbell BCV, Mishra NK, Mlynash M, Levi C, et al. A benchmarking tool to evaluate computer tomography perfusion infarct core predictions against a DWI standard. J Cereb Blood Flow Metab. 2016;36(10):1780\u20139.","journal-title":"J Cereb Blood Flow Metab"},{"issue":"3","key":"2095_CR19","doi-asserted-by":"publisher","first-page":"401","DOI":"10.1002\/sim.3769","volume":"29","author":"B Carstensen","year":"2010","unstructured":"Carstensen B. Comparing methods of measurement: extending the LoA by regression. Stat Med. 2010;29(3):401\u201310.","journal-title":"Stat Med"},{"issue":"3","key":"2095_CR20","doi-asserted-by":"publisher","first-page":"466","DOI":"10.1002\/1522-2594(200009)44:3<466::AID-MRM18>3.0.CO;2-M","volume":"44","author":"F Calamante","year":"2000","unstructured":"Calamante F, Gadian DG, Connelly A. Delay and dispersion effects in dynamic susceptibility contrast MRI: simulations using singular value decomposition. Magn Reson Med. 2000;44(3):466\u201373.","journal-title":"Magn Reson Med"},{"issue":"1","key":"2095_CR21","doi-asserted-by":"publisher","first-page":"164","DOI":"10.1002\/mrm.10522","volume":"50","author":"O Wu","year":"2003","unstructured":"Wu O, \u00d8stergaard L, Weisskoff RM, Benner T, Rosen BR, Sorensen AG. Tracer arrival timing-insensitive technique for estimating flow in MR perfusion-weighted imaging using singular value decomposition with a block-circulant deconvolution matrix. Magn Reson Med. 2003;50(1):164\u201374.","journal-title":"Magn Reson Med"},{"issue":"2","key":"2095_CR22","doi-asserted-by":"publisher","first-page":"329","DOI":"10.3174\/ajnr.A8963","volume":"47","author":"F Tortora","year":"2026","unstructured":"Tortora F, Gragnano E, Cocozza S, Di Monaco C, Esposito A, Gianani F, et al. The impact of different CT perfusion software on patient stratification strategies in ischemic stroke. AJNR Am J Neuroradiol. 2026;47(2):329\u201335.","journal-title":"AJNR Am J Neuroradiol"}],"container-title":["Japanese Journal of Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11604-026-02095-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11604-026-02095-2","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11604-026-02095-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,17]],"date-time":"2026-10-17T19:04:01Z","timestamp":1792263841000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11604-026-02095-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,17]]},"references-count":22,"alternative-id":["2095"],"URL":"https:\/\/doi.org\/10.1007\/s11604-026-02095-2","relation":{},"ISSN":["1867-1071","1867-108X"],"issn-type":[{"value":"1867-1071","type":"print"},{"value":"1867-108X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,17]]},"assertion":[{"value":"1 June 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 September 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 October 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"K. Noutomi, K. Ishibashi and M. Anzai are currently employed by Micron, Inc. Micron, Inc. provided the PMAneo software and support for data analysis and data processing. Kohsuke Kudo developed the PMAneo software, which has been licensed to Micron, Inc., and receives royalties related to the software. The other authors declare that they have no conflicts of interest.","order":1,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The institutional review board (IRB) of Hokkaido University Hospital approved this retrospective study (ID: 018-0238), and the requirement to obtain patients' informed consent was waived. The study was conducted in accord with the ethical standards of the IRB and with the 1964 Helsinki Declaration and its later amendments.","order":2,"name":"Ethics","label":"Ethical approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":3,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}}]}}