{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,2]],"date-time":"2026-01-02T07:47:19Z","timestamp":1767340039092,"version":"build-2065373602"},"reference-count":31,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2017,2,1]],"date-time":"2017-02-01T00:00:00Z","timestamp":1485907200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2017,2,1]],"date-time":"2017-02-01T00:00:00Z","timestamp":1485907200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["jgisurgery.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Gastrointestinal Surgery"],"published-print":{"date-parts":[[2017,2]]},"DOI":"10.1007\/s11605-016-3312-y","type":"journal-article","created":{"date-parts":[[2016,10,31]],"date-time":"2016-10-31T10:23:28Z","timestamp":1477909408000},"page":"321-329","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["Spray Diathermy Versus Harmonic Scalpel Technique for Hepatic Parenchymal Transection of Living Donor"],"prefix":"10.1016","volume":"21","author":[{"given":"Mohamed","family":"El Shobary","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tarek","family":"salah","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ayman","family":"El Nakeeb","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ahmad M.","family":"Sultan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ahmed","family":"Elghawalby","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Omar","family":"Fathy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohamed Abdel","family":"Wahab","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Amro","family":"Yassen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohamed","family":"Elmorshedy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wagdi F.","family":"Elkashef","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Usama","family":"Shiha","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohamed","family":"Elsadany","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1007\/s11605-016-3312-y_bb0010","first-page":"1181","volume":"16","author":"Salah","year":"2012","journal-title":"Outcome of Right Hepatectomy for Living Liver Donors: A Single Egyptian Center Experience J Gastrointest Surg"},{"issue":"37","key":"10.1007\/s11605-016-3312-y_bb0015","doi-asserted-by":"crossref","first-page":"13607","DOI":"10.3748\/wjg.v20.i37.13607","article-title":"Problem of living liver donation in the absence of deceased liver transplantation program: Mansoura experience","volume":"20","author":"Abdel Wahab","year":"2014","journal-title":"World J Gastroenterol"},{"key":"10.1007\/s11605-016-3312-y_bb0020","doi-asserted-by":"crossref","first-page":"905","DOI":"10.1097\/01.sla.0000164077.77912.98","article-title":"Analysis of long-term outcomes of 3200 liver transplantations over two decades: a single center experience","volume":"241","author":"Busuttil","year":"2005","journal-title":"Ann Surg."},{"key":"10.1007\/s11605-016-3312-y_bb0025","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1111\/j.1600-6143.2004.00654.x","article-title":"Adult living donor versus deceased donor liver transplantation: a 6-year single center experience","volume":"5","author":"Maluf","year":"2005","journal-title":"Am J Transplant."},{"issue":"1","key":"10.1007\/s11605-016-3312-y_bb0030","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1002\/lt.21658","article-title":"Two different methods for donor hepatic transection: cavitron ultrasonic surgical aspirator with bipolar cautery versus cavitron ultrasonic surgical aspirator with radiofrequency coagulator-A randomized controlled trial","volume":"15","author":"El Moghazy","year":"2009","journal-title":"Liver Transpl"},{"issue":"2","key":"10.1007\/s11605-016-3312-y_bb0035","doi-asserted-by":"crossref","first-page":"e25","DOI":"10.1016\/j.amjsurg.2008.01.019","article-title":"Two-surgeon technique using saline-linked electric cautery and ultrasonic surgical aspirator in living donor hepatectomy: its safety and efficacy","volume":"197","author":"Takatsuki","year":"2009","journal-title":"Am J Surg"},{"issue":"5","key":"10.1007\/s11605-016-3312-y_bb0040","doi-asserted-by":"crossref","first-page":"1046","DOI":"10.1016\/j.surg.2013.04.053","article-title":"A prospective randomized controlled trial of hemostasis with a bipolar sealer during hepatic transection for liver resection","volume":"154","author":"Kaibori","year":"2013","journal-title":"Surgery"},{"issue":"3","key":"10.1007\/s11605-016-3312-y_bb0045","first-page":"630","article-title":"Meta-analysis of the clamp-crushing technique for transection of the parenchyma in elective hepatic resection: back to where we started?","volume":"16","author":"Rahbari","year":"2009","journal-title":"AnnSurg Oncol"},{"key":"10.1007\/s11605-016-3312-y_bb0050","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1186\/1471-2482-11-22","article-title":"Clamp-crushing versus stapler hepatectomy for transection of the parenchyma in elective hepatic resection (CRUNSH)--a randomized controlled trial","volume":"11","author":"Rahbari","year":"2011","journal-title":"BMC Surg."},{"issue":"1","key":"10.1007\/s11605-016-3312-y_bb0055","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1007\/s00268-009-0282-1","article-title":"Fusion technique for liver transection with Kelly-clysis and harmonic technology","volume":"34","author":"Jagannath","year":"2010","journal-title":"World J Surg"},{"issue":"3","key":"10.1007\/s11605-016-3312-y_bb0060","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1080\/13651820701216182","article-title":"Current techniques of liver transection","volume":"9","author":"Poon","year":"2007","journal-title":"HPB (Oxford)"},{"issue":"8","key":"10.1007\/s11605-016-3312-y_bb0065","doi-asserted-by":"crossref","first-page":"922","DOI":"10.1001\/archsurg.136.8.922","article-title":"Randomized comparison of ultrasonic vs clamp transection of the liver","volume":"136","author":"Takayama","year":"2001","journal-title":"Arch Surg"},{"issue":"5","key":"10.1007\/s11605-016-3312-y_bb0070","doi-asserted-by":"crossref","first-page":"500","DOI":"10.1016\/j.ijsu.2014.02.007","article-title":"Liver resection using cavitron ultrasonic surgical aspirator (CUSA) versus harmonic scalpel: a retrospective cohort study","volume":"12","author":"Bodzin","year":"2014","journal-title":"Int J Surg"},{"key":"10.1007\/s11605-016-3312-y_bb0075","first-page":"814","article-title":"How should transection of liver be performed? A prospective randomized study in 100 consecutive patients: comparing four different transection strategies","volume":"242","author":"Lesuret","year":"2005","journal-title":"Ann Surg"},{"key":"10.1007\/s11605-016-3312-y_bb0080","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/j.amjsurg.2006.01.025","article-title":"Usefulness of Ligasure for liver resection: analysis by randomized clinical trial","volume":"192","author":"Saiura","year":"2006","journal-title":"Am J Surg"},{"key":"10.1007\/s11605-016-3312-y_bb0085","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1016\/S0002-9610(02)01419-8","article-title":"Decreasing mortality of bile leaks after elective hepatic surgery","volume":"185","author":"Reed","year":"2003","journal-title":"Am J Surg"},{"issue":"2","key":"10.1007\/s11605-016-3312-y_bb0090","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1002\/jso.21575","article-title":"Usefulness of the combination procedure of crash clamping and vessel sealing for hepaticresection","volume":"102","author":"Nanashima","year":"2010","journal-title":"J Surg Oncol"},{"key":"10.1007\/s11605-016-3312-y_bb0095","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1007\/s00268-005-0192-9","article-title":"Stapler hepatectomy is a safe dissection technique: analysis of 300 patients","volume":"30","author":"Schemmer","year":"2006","journal-title":"World J Surg"},{"key":"10.1007\/s11605-016-3312-y_bb0100","doi-asserted-by":"crossref","first-page":"959","DOI":"10.1007\/s005950070055","article-title":"Hepatic resection using the harmonic scalpel","volume":"30","author":"Sugo","year":"2000","journal-title":"Surg Today"},{"issue":"9","key":"10.1007\/s11605-016-3312-y_bb0105","doi-asserted-by":"crossref","first-page":"2156","DOI":"10.1007\/s00268-012-1624-y","article-title":"Surgical outcome of liver transection bythe crush-clamping technique combined withHarmonic FOCUS\u2122","volume":"36","author":"Gotohda","year":"2012","journal-title":"World J Surg"},{"issue":"3","key":"10.1007\/s11605-016-3312-y_bb0110","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1002\/bjs.9387","article-title":"Randomized clinical trial of stapler versus clamp-crushing transection in elective liver resection","volume":"101","author":"Rahbari","year":"2014","journal-title":"Br J Surg"},{"key":"10.1007\/s11605-016-3312-y_bb0115","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1007\/s00268-003-7167-5","article-title":"Yamaguchi Tet al. Bloodless liver resection using the monopolar floating ball plus ligasure diathermy: preliminary results of 16 liver resections","volume":"28","author":"Sakamoto","year":"2004","journal-title":"World J Surg"},{"key":"10.1007\/s11605-016-3312-y_bb0120","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1097\/00000658-200211000-00004","article-title":"New technique for liver resection using heat coagulative necrosis","volume":"236","author":"Weber","year":"2002","journal-title":"Ann Surg."},{"key":"10.1007\/s11605-016-3312-y_bb0125","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1007\/s00595-009-4143-1","article-title":"Biliary complications in living liver donors","volume":"40","author":"Yuan","year":"2010","journal-title":"Surg Today"},{"key":"10.1007\/s11605-016-3312-y_bb0130","doi-asserted-by":"crossref","first-page":"1393","DOI":"10.1002\/lt.23964","article-title":"Biliary complications in living donor right hepatectomy are affected by the method of bile duct division","volume":"20","author":"Sultan","year":"2014","journal-title":"Liver Transpl"},{"key":"10.1007\/s11605-016-3312-y_bb0135","doi-asserted-by":"crossref","first-page":"942","DOI":"10.1097\/TP.0b013e31824ad5de","article-title":"Donor morbidity including biliary complications in living-donor liver transplantation: single-center analysis of 827 cases","volume":"93","author":"Shin","year":"2012","journal-title":"Transplantation"},{"key":"10.1007\/s11605-016-3312-y_bb0140","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1177\/000313480306900918","article-title":"Increased biliary fistulas after liver resection with the harmonic scalpel","volume":"69","author":"Kim","year":"2003","journal-title":"Am Surg"},{"issue":"2","key":"10.1007\/s11605-016-3312-y_bb0145","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1016\/j.ejso.2014.10.057","article-title":"A prospective randomized controlled trial: comparison of two different methods of hepatectomy","volume":"41","author":"Hanyong","year":"2015","journal-title":"Eur J Surg Oncol"},{"key":"10.1007\/s11605-016-3312-y_bb0150","article-title":"Techniques for liver parenchymal transection in liver resection (Review)","volume":"1","author":"Gurusamy","year":"2009","journal-title":"Cochrane Database Syst Rev."},{"issue":"4","key":"10.1007\/s11605-016-3312-y_bb0155","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1111\/j.1477-2574.2009.00057.x","article-title":"Techniques for liver parenchymal transection: a meta-analysis of randomized controlled trials","volume":"11","author":"Pamecha","year":"2009","journal-title":"HPB (Oxford)"},{"key":"10.1007\/s11605-016-3312-y_bb0160","doi-asserted-by":"crossref","DOI":"10.1002\/14651858.CD010683.pub2","article-title":"Methods to decrease blood loss during liver resection: a network meta-analysis","volume":"4","author":"Simillis","year":"2014","journal-title":"Cochrane Database Syst Rev."}],"container-title":["Journal of Gastrointestinal Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11605-016-3312-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11605-016-3312-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1091255X23025817?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1091255X23025817?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11605-016-3312-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T19:51:07Z","timestamp":1761076267000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1091255X23025817"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,2]]},"references-count":31,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2017,2]]}},"alternative-id":["S1091255X23025817"],"URL":"https:\/\/doi.org\/10.1007\/s11605-016-3312-y","relation":{},"ISSN":["1091-255X"],"issn-type":[{"type":"print","value":"1091-255X"}],"subject":[],"published":{"date-parts":[[2017,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Spray Diathermy Versus Harmonic Scalpel Technique for Hepatic Parenchymal Transection of Living Donor","name":"articletitle","label":"Article Title"},{"value":"Journal of Gastrointestinal Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1007\/s11605-016-3312-y","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2016 Society for Surgery of the Alimentary Tract. Published by ELSEVIER INC. All rights reserved. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}