{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T19:35:24Z","timestamp":1792784124625,"version":"4.5.0"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,1,5]],"date-time":"2025-01-05T00:00:00Z","timestamp":1736035200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,1,5]],"date-time":"2025-01-05T00:00:00Z","timestamp":1736035200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"name":"Key R&D Project of Autonomous Region","award":["No.2023BEG02018"],"award-info":[{"award-number":["No.2023BEG02018"]}]},{"name":"Autonomous Region Major Scientific and Technological; Achievements Transformation Project","award":["No. 2023CJE09037"],"award-info":[{"award-number":["No. 2023CJE09037"]}]},{"name":"Ningxia Medical University General Hospital \"Medical Engineering Special\"","award":["No. NYZYYG-001"],"award-info":[{"award-number":["No. NYZYYG-001"]}],"id":[{"id":"https:\/\/ror.org\/049dkqr57","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Robotic Surg"],"DOI":"10.1007\/s11701-024-02204-1","type":"journal-article","created":{"date-parts":[[2025,1,5]],"date-time":"2025-01-05T01:50:48Z","timestamp":1736041848000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["TiRobot-assisted versus freehand femoral neck system placement in the treatment of femoral neck fractures: a systematic review and meta-analysis"],"prefix":"10.1007","volume":"19","author":[{"given":"Yupei","family":"Dai","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kaiyong","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guohang","family":"Shen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yang","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anneng","family":"Hu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qunhua","family":"Jin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,1,5]]},"reference":[{"key":"2204_CR1","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1097\/bot.0000000000000291","volume":"29","author":"F Av","year":"2015","unstructured":"Av F et al (2015) Femoral neck fractures: current management. J Orthop Trauma 29:121\u2013129. https:\/\/doi.org\/10.1097\/bot.0000000000000291","journal-title":"J Orthop Trauma"},{"key":"2204_CR2","doi-asserted-by":"publisher","DOI":"10.1007\/s11657-022-01148-z","author":"R Tiihonen","year":"2022","unstructured":"Tiihonen R et al (2022) Patient-specific factors affecting survival following hip fractures-a 14-year follow-up study in Finland. Arch Osteoporos. https:\/\/doi.org\/10.1007\/s11657-022-01148-z","journal-title":"Arch Osteoporos"},{"key":"2204_CR3","doi-asserted-by":"publisher","first-page":"959","DOI":"10.1186\/s13018-023-04435-8","volume":"18","author":"T Wu","year":"2023","unstructured":"Wu T et al (2023) Systematic analysis of hip-preserving treatment for early osteonecrosis of the femoral head from the perspective of bibliometrics (2010\u20132023). J Orthop Surg Res 18:959. https:\/\/doi.org\/10.1186\/s13018-023-04435-8","journal-title":"J Orthop Surg Res"},{"key":"2204_CR4","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-022-11914-1","author":"M Jk","year":"2022","unstructured":"Jk M et al (2022) Biomechanical comparison of the femoral neck system and the dynamic hip screw in basicervical femoral neck fractures. Sci Rep. https:\/\/doi.org\/10.1038\/s41598-022-11914-1","journal-title":"Sci Rep"},{"key":"2204_CR5","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-021-02517-z","author":"H Hu","year":"2021","unstructured":"Hu H et al (2021) Clinical outcome of femoral neck system versus cannulated compression screws for fixation of femoral neck fracture in younger patients. J Orthop Surg Res. https:\/\/doi.org\/10.1186\/s13018-021-02517-z","journal-title":"J Orthop Surg Res"},{"key":"2204_CR6","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-024-07863-7","author":"Z Xu","year":"2024","unstructured":"Xu Z et al (2024) Comparative analysis of the femoral neck system (FNS) vs cannulated cancellous screws (CCS) in the treatment of Middle-aged and elderly patients with femoral neck fractures: clinical outcomes and biomechanical insights. BMC Musculoskelet Disord. https:\/\/doi.org\/10.1186\/s12891-024-07863-7","journal-title":"BMC Musculoskelet Disord"},{"key":"2204_CR7","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1007\/s00590-020-02742-y","volume":"31","author":"Lh Goodnough","year":"2021","unstructured":"Goodnough Lh et al (2021) Is percutaneous screw fixation really superior to non-operative management after valgus-impacted femoral neck fracture: a retrospective cohort study. Eur J Orthop Surg Traumatol 31:65\u201370. https:\/\/doi.org\/10.1007\/s00590-020-02742-y","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"2204_CR8","doi-asserted-by":"publisher","first-page":"946","DOI":"10.7507\/1002-1892.202203093","volume":"36","author":"Y Jing","year":"2022","unstructured":"Jing Y et al (2022) Short-term effectiveness of orthopedic robot-assisted femoral neck system fixation for fresh femoral neck fractures. Chinese J Reparat Reconstruct Surg 36:946\u2013950. https:\/\/doi.org\/10.7507\/1002-1892.202203093","journal-title":"Chinese J Reparat Reconstruct Surg"},{"key":"2204_CR9","doi-asserted-by":"publisher","DOI":"10.12200\/j.issn.1003-0034.20230955","author":"W Xz","year":"2024","unstructured":"Xz W et al (2024) Orthopaedic robot assisted femoral neck dynamic cross fixation system for the treatment of femoral neck fractures. China J Orthop Traumat. https:\/\/doi.org\/10.12200\/j.issn.1003-0034.20230955","journal-title":"China J Orthop Traumat"},{"key":"2204_CR10","doi-asserted-by":"publisher","first-page":"1471","DOI":"10.7507\/1002-1892.202308051","volume":"37","author":"Y Liu","year":"2023","unstructured":"Liu Y et al (2023) Early effectiveness of Ti-Robot assisted femoral neck system for minimally invasive treatment of elderly Garden type II and III femoral neck fractures. Chinese J Reparat Reconstr Surg 37:1471\u20131476. https:\/\/doi.org\/10.7507\/1002-1892.202308051","journal-title":"Chinese J Reparat Reconstr Surg"},{"key":"2204_CR11","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1186\/s12891-024-07172-z","volume":"25","author":"G Liu","year":"2024","unstructured":"Liu G et al (2024) Application of robot navigation system for insertion of femoral neck system in the treatment of femoral neck fracture. BMC Musculoskelet Disord 25:47. https:\/\/doi.org\/10.1186\/s12891-024-07172-z","journal-title":"BMC Musculoskelet Disord"},{"key":"2204_CR12","doi-asserted-by":"publisher","first-page":"1006","DOI":"10.1016\/j.jclinepi.2009.06.005","volume":"62","author":"D Moher","year":"2009","unstructured":"Moher D et al (2009) Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. J Clin Epidemiol 62:1006\u20131012. https:\/\/doi.org\/10.1016\/j.jclinepi.2009.06.005","journal-title":"J Clin Epidemiol"},{"key":"2204_CR13","doi-asserted-by":"publisher","first-page":"603","DOI":"10.1007\/s10654-010-9491-z","volume":"25","author":"Stang a %J European Journal Of Epid","year":"2010","unstructured":"Stang a %J European Journal Of Epidemiology, (2010) Critical evaluation of the Newcastle-Ottawa scale for the assessment of the quality of nonrandomized studies in meta-analyses. Eur J Epidemiol 25:603\u2013605. https:\/\/doi.org\/10.1007\/s10654-010-9491-z","journal-title":"Eur J Epidemiol"},{"key":"2204_CR14","doi-asserted-by":"publisher","first-page":"5235","DOI":"10.1007\/s00431-023-05216-5","volume":"182","author":"Z Lan","year":"2023","unstructured":"Lan Z et al (2023) Effectiveness of COVID-19 vaccines among children and adolescents against SARS-CoV-2 variants: a meta-analysis. Eur J Pediatr 182:5235\u20135244. https:\/\/doi.org\/10.1007\/s00431-023-05216-5","journal-title":"Eur J Pediatr"},{"key":"2204_CR15","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1136\/bmj.327.7414.557","volume":"327","author":"H Jp","year":"2003","unstructured":"Jp H et al (2003) Measuring inconsistency in meta-analyses. BMJ 327:557\u2013560. https:\/\/doi.org\/10.1136\/bmj.327.7414.557","journal-title":"BMJ"},{"key":"2204_CR16","doi-asserted-by":"publisher","first-page":"2073","DOI":"10.1038\/s41433-022-02108-0","volume":"36","author":"S Parpia","year":"2022","unstructured":"Parpia S et al (2022) Sensitivity analysis in clinical trials: three criteria for a valid sensitivity analysis. Eye (Lond) 36:2073\u20132074. https:\/\/doi.org\/10.1038\/s41433-022-02108-0","journal-title":"Eye (Lond)"},{"key":"2204_CR17","doi-asserted-by":"publisher","first-page":"597","DOI":"10.1136\/bmj.333.7568.597","volume":"333","author":"J Lau","year":"2006","unstructured":"Lau J et al (2006) The case of the misleading funnel plot. BMJ 333:597\u2013600. https:\/\/doi.org\/10.1136\/bmj.333.7568.597","journal-title":"BMJ"},{"key":"2204_CR18","doi-asserted-by":"publisher","first-page":"1119","DOI":"10.1016\/s0895-4356(00)00242-0","volume":"53","author":"S Ja","year":"2000","unstructured":"Ja S et al (2000) Publication and related bias in meta-analysis: power of statistical tests and prevalence in the literature. J Clin Epidemiol 53:1119\u20131129. https:\/\/doi.org\/10.1016\/s0895-4356(00)00242-0","journal-title":"J Clin Epidemiol"},{"key":"2204_CR19","first-page":"511","volume":"13","author":"Wang Bing\u2043Yi Tang Shuai, Fan Lei, L","year":"2022","unstructured":"Wang Bing\u2043Yi Tang Shuai, Fan Lei, Li Xiao\u2043Bin, Gao Qiang, Peng Qiang, Cao Zhi\u2043Ming, Liu Tao, (2022) Efficacy of robot guided femoral neck system in the treatment of femoral neck fracture. Orthopaedics 13:511\u2013515","journal-title":"Orthopaedics"},{"issue":"541","key":"2204_CR20","doi-asserted-by":"publisher","first-page":"546","DOI":"10.3969\/j.issn.1007-3205.2023.05.009","volume":"44","author":"L YuBin","year":"2023","unstructured":"YuBin L, Wei C, HongWei J, BaoJun An H, Ming. (2023) Short-term effect of femoral neck system assisted by an orthopaedic robot\"TINAVI\u2019 in femoral neck fracture in middle-aged and elderly people. J Hebeimed Univer 44(541):546. https:\/\/doi.org\/10.3969\/j.issn.1007-3205.2023.05.009","journal-title":"J Hebeimed Univer"},{"key":"2204_CR21","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1111\/os.12430","volume":"11","author":"D Sj","year":"2019","unstructured":"Sj D et al (2019) Robot-assisted percutaneous cannulated screw fixation of femoral neck fractures: preliminary clinical results. Orthop Surg 11:34\u201341. https:\/\/doi.org\/10.1111\/os.12430","journal-title":"Orthop Surg"},{"key":"2204_CR22","doi-asserted-by":"publisher","DOI":"10.1016\/j.exger.2024.112565","volume":"196","author":"Z Yin","year":"2024","unstructured":"Yin Z et al (2024) Comparison of the surgical efficacy of robot-assisted and freehand nail placement in the treatment of sarcopenia combined with femoral neck fractures younger than 65 years. Exp Gerontol 196:112565. https:\/\/doi.org\/10.1016\/j.exger.2024.112565","journal-title":"Exp Gerontol"},{"key":"2204_CR23","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1111\/os.12451","volume":"11","author":"Wu Xb","year":"2019","unstructured":"Xb Wu et al (2019) Guidance for the treatment of femoral neck fracture with precise minimally invasive internal fixation based on the orthopaedic surgery robot positioning system. Orthop Surg 11:335\u2013340. https:\/\/doi.org\/10.1111\/os.12451","journal-title":"Orthop Surg"},{"key":"2204_CR24","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1007\/s00590-021-03167-x","volume":"33","author":"A Al-Naseem","year":"2023","unstructured":"Al-Naseem A et al (2023) Robot-assisted versus conventional percutaneous sacroiliac screw fixation for posterior pelvic ring injuries: a systematic review and meta-analysis. Eur J Orthop Surg Traumatol 33:9\u201320. https:\/\/doi.org\/10.1007\/s00590-021-03167-x","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"2204_CR25","doi-asserted-by":"publisher","DOI":"10.1186\/s40634-020-00309-8","author":"R Negr\u00edn","year":"2020","unstructured":"Negr\u00edn R et al (2020) Robotic-assisted Unicompartmental knee Arthroplasty optimizes joint line restitution better than conventional surgery. J Exp Orthop. https:\/\/doi.org\/10.1186\/s40634-020-00309-8","journal-title":"J Exp Orthop"},{"key":"2204_CR26","doi-asserted-by":"publisher","first-page":"1501","DOI":"10.1097\/TA.0b013e3181d862db","volume":"69","author":"J Zwingmann","year":"2010","unstructured":"Zwingmann J et al (2010) Percutaneous iliosacral screw insertion: malpositioning and revision rate of screws with regards to application technique (navigated vs. Conventional). J Trauma 69:1501\u20131506. https:\/\/doi.org\/10.1097\/TA.0b013e3181d862db","journal-title":"J Trauma"},{"key":"2204_CR27","doi-asserted-by":"publisher","first-page":"1064","DOI":"10.1016\/j.injury.2015.01.038","volume":"46","author":"W Jm","year":"2015","unstructured":"Jm W et al (2015) Fluoroscopically assisted computer navigation enables accurate percutaneous screw placement for pelvic and acetabular fracture fixation. Injury 46:1064\u20131068. https:\/\/doi.org\/10.1016\/j.injury.2015.01.038","journal-title":"Injury"},{"key":"2204_CR28","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620x.97b3.35107","author":"K Karthik","year":"2015","unstructured":"Karthik K et al (2015) Robotic surgery in trauma and orthopaedics: a systematic review. Bone Joint J. https:\/\/doi.org\/10.1302\/0301-620x.97b3.35107","journal-title":"Bone Joint J"},{"key":"2204_CR29","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2004.05.005","author":"N Lp","year":"2004","unstructured":"Lp N et al (2004) Basic principles of CAOS. Injury. https:\/\/doi.org\/10.1016\/j.injury.2004.05.005","journal-title":"Injury"},{"key":"2204_CR30","doi-asserted-by":"publisher","first-page":"373","DOI":"10.1111\/os.12450","volume":"11","author":"M He","year":"2019","unstructured":"He M et al (2019) Evaluation of a bi-planar robot navigation system for insertion of cannulated screws in femoral neck fractures. Orthop Surg 11:373\u2013379. https:\/\/doi.org\/10.1111\/os.12450","journal-title":"Orthop Surg"},{"key":"2204_CR31","doi-asserted-by":"publisher","first-page":"3755","DOI":"10.1007\/s00402-021-04216-0","volume":"142","author":"S Rc","year":"2022","unstructured":"Rc S et al (2022) First clinical results of 1-year follow-up of the femoral neck system for internal fixation of femoral neck fractures. Arch Orthop Trauma Surg 142:3755\u20133763. https:\/\/doi.org\/10.1007\/s00402-021-04216-0","journal-title":"Arch Orthop Trauma Surg"},{"key":"2204_CR32","doi-asserted-by":"publisher","first-page":"2105","DOI":"10.1007\/s00264-022-05414-0","volume":"46","author":"A Davidson","year":"2022","unstructured":"Davidson A et al (2022) Neck of femur fractures treated with the femoral neck system: outcomes of one hundred and two patients and literature review. Int Orthop 46:2105\u20132115. https:\/\/doi.org\/10.1007\/s00264-022-05414-0","journal-title":"Int Orthop"},{"key":"2204_CR33","doi-asserted-by":"publisher","first-page":"4155","DOI":"10.1007\/s00402-022-04686-w","volume":"143","author":"K Stoffel","year":"2023","unstructured":"Stoffel K et al (2023) Clinical performance of the Femoral Neck System within 1 year in 125 patients with acute femoral neck fractures, a prospective observational case series. Arch Orthop Trauma Surg 143:4155\u20134164. https:\/\/doi.org\/10.1007\/s00402-022-04686-w","journal-title":"Arch Orthop Trauma Surg"},{"key":"2204_CR34","doi-asserted-by":"publisher","first-page":"2301","DOI":"10.1007\/s00264-024-06242-0","volume":"48","author":"B Obada","year":"2024","unstructured":"Obada B et al (2024) Clinical outcomes of total hip arthroplasty after femoral neck fractures vs. osteoarthritis at one year follow up-A comparative, retrospective study. Int Orthop 48:2301\u20132310. https:\/\/doi.org\/10.1007\/s00264-024-06242-0","journal-title":"Int Orthop"},{"key":"2204_CR35","doi-asserted-by":"publisher","first-page":"1186","DOI":"10.1111\/os.13318","volume":"14","author":"Y Liu","year":"2022","unstructured":"Liu Y et al (2022) Micro-computed tomography analysis of femoral head necrosis after long-term internal fixation for femoral neck fracture. Orthop Surg 14:1186\u20131192. https:\/\/doi.org\/10.1111\/os.13318","journal-title":"Orthop Surg"},{"key":"2204_CR36","doi-asserted-by":"publisher","DOI":"10.12659\/msm.899476","author":"X Chen","year":"2017","unstructured":"Chen X et al (2017) Incidence of and factors influencing femoral neck shortening in elderly patients after fracture fixation with multiple cancellous screws. Med Sci Mon. https:\/\/doi.org\/10.12659\/msm.899476","journal-title":"Med Sci Mon"}],"container-title":["Journal of Robotic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11701-024-02204-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11701-024-02204-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11701-024-02204-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,4]],"date-time":"2026-01-04T01:23:31Z","timestamp":1767489811000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11701-024-02204-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,5]]},"references-count":36,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["2204"],"URL":"https:\/\/doi.org\/10.1007\/s11701-024-02204-1","relation":{},"ISSN":["1863-2491"],"issn-type":[{"value":"1863-2491","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,5]]},"assertion":[{"value":"12 November 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 December 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 January 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interests"}},{"value":"Since this study is a meta-analysis, the data were obtained from previously released studies, with no direct participant contact or collection of personal information. Consequently, ethical approval and institutional review board approval were not required. This approach ensures the research's independence and objectivity while safeguarding participants' privacy and rights.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical Approval"}}],"article-number":"43"}}