{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T18:24:14Z","timestamp":1789496654754,"version":"build-2803163510"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,8,26]],"date-time":"2025-08-26T00:00:00Z","timestamp":1756166400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,8,26]],"date-time":"2025-08-26T00:00:00Z","timestamp":1756166400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Robotic Surg"],"DOI":"10.1007\/s11701-025-02695-6","type":"journal-article","created":{"date-parts":[[2025,8,26]],"date-time":"2025-08-26T11:19:42Z","timestamp":1756207182000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Advantages of TiRobot-assisted technology in internal fixation of femoral neck fractures: a meta-analysis of surgical parameters and complications"],"prefix":"10.1007","volume":"19","author":[{"given":"Yupei","family":"Dai","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huiling","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yang","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kaiyong","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jian","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mingyuan","family":"Fan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guohang","family":"Shen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,8,26]]},"reference":[{"key":"2695_CR1","doi-asserted-by":"publisher","first-page":"1134","DOI":"10.1007\/s43465-024-01198-0","volume":"58","author":"N Do\u011fan","year":"2024","unstructured":"Do\u011fan N et al (2024) Investigation of novel radiological parameters to predict treatment failure and ideal surgical interventions in young femoral neck fractures treated with triple cannulated screw: a retrospective analysis. Indian J Orthop 58:1134\u20131144. https:\/\/doi.org\/10.1007\/s43465-024-01198-0","journal-title":"Indian J Orthop"},{"key":"2695_CR2","doi-asserted-by":"publisher","first-page":"718","DOI":"10.4055\/cios24089","volume":"16","author":"DH Lee","year":"2024","unstructured":"Lee DH et al (2024) The effects and risk factors of femoral neck shortening after internal fixation of femoral neck fractures. Clin Orthop Surg 16:718\u2013723. https:\/\/doi.org\/10.4055\/cios24089","journal-title":"Clin Orthop Surg"},{"key":"2695_CR3","volume":"13","author":"HH Lee","year":"2024","unstructured":"Lee HH et al (2024) Femoral neck fractures treated by closed reduction and internal fixation with the double fluoroscope technique: a preliminary study. J Clin Med 13:10.3390\/jcm13051418","journal-title":"J Clin Med"},{"key":"2695_CR4","doi-asserted-by":"publisher","first-page":"e302","DOI":"10.5435\/jaaos-d-23-00720","volume":"32","author":"RA Rajfer","year":"2024","unstructured":"Rajfer RA et al (2024) High-energy femoral neck fractures in young patients. J Am Acad Orthop Surg 32:e302\u2013e312. https:\/\/doi.org\/10.5435\/jaaos-d-23-00720","journal-title":"J Am Acad Orthop Surg"},{"key":"2695_CR5","doi-asserted-by":"publisher","first-page":"570","DOI":"10.1186\/s13018-023-04002-1","volume":"18","author":"Y Wei","year":"2023","unstructured":"Wei Y et al (2023) Fibula allograft with cannulated screw fixation versus ordinary cannulated screw fixation for femoral neck fractures: a 10-year retrospective comparative study. J Orthop Surg Res 18:570. https:\/\/doi.org\/10.1186\/s13018-023-04002-1","journal-title":"J Orthop Surg Res"},{"issue":"Suppl 2","key":"2695_CR6","doi-asserted-by":"publisher","first-page":"S28","DOI":"10.1016\/j.injury.2022.03.041","volume":"54","author":"X Xu","year":"2023","unstructured":"Xu X et al (2023) Comparison of femoral neck system to multiple cancellous screws and dynamic hip screws in the treatment of femoral neck fractures. Injury 54(Suppl 2):S28-s35. https:\/\/doi.org\/10.1016\/j.injury.2022.03.041","journal-title":"Injury"},{"key":"2695_CR7","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2025.112621","volume":"56","author":"Y Huang","year":"2025","unstructured":"Huang Y et al (2025) Comparative study on the efficacy of femoral neck system, FNS with anti-rotation screws, and multiple cancellous screws in treating femoral neck fractures in young and middle-aged patients. Injury 56:112621. https:\/\/doi.org\/10.1016\/j.injury.2025.112621","journal-title":"Injury"},{"key":"2695_CR8","doi-asserted-by":"publisher","first-page":"19508","DOI":"10.1038\/s41598-025-04188-w","volume":"15","author":"D Zhao","year":"2025","unstructured":"Zhao D et al (2025) A comparative study of internal fixation with porous tantalum screws and cannulated screws in the treatment of femoral neck fractures. Sci Rep 15:19508. https:\/\/doi.org\/10.1038\/s41598-025-04188-w","journal-title":"Sci Rep"},{"key":"2695_CR9","doi-asserted-by":"publisher","first-page":"2791","DOI":"10.1007\/s00590-024-04004-7","volume":"34","author":"D Carola","year":"2024","unstructured":"Carola D et al (2024) Cannulated screws fixation for nondisplaced femoral neck fractures: early versus late weight-bearing-a prospective analysis. Eur J Orthop Surg Traumatol 34:2791\u20132796. https:\/\/doi.org\/10.1007\/s00590-024-04004-7","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"2695_CR10","doi-asserted-by":"publisher","first-page":"2565","DOI":"10.1007\/s00590-024-03956-0","volume":"34","author":"SD Scattergood","year":"2024","unstructured":"Scattergood SD et al (2024) Low avascular necrosis rates in femoral neck fractures: efficacy of cannulated screw fixation. Eur J Orthop Surg Traumatol 34:2565\u20132571. https:\/\/doi.org\/10.1007\/s00590-024-03956-0","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"2695_CR11","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.71767","volume":"16","author":"D Giotis","year":"2024","unstructured":"Giotis D et al (2024) Internal fixation with cannulated screws for stable femoral neck fractures in high-risk patients: good clinical outcomes and evaluation of postoperative complications. Cureus 16:e71767. https:\/\/doi.org\/10.7759\/cureus.71767","journal-title":"Cureus"},{"key":"2695_CR12","doi-asserted-by":"publisher","first-page":"373","DOI":"10.1111\/os.12450","volume":"11","author":"M He","year":"2019","unstructured":"He M et al (2019) Evaluation of a bi-planar robot navigation system for insertion of cannulated screws in femoral neck fractures. Orthop Surg 11:373\u2013379. https:\/\/doi.org\/10.1111\/os.12450","journal-title":"Orthop Surg"},{"key":"2695_CR13","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.b2535","volume":"339","author":"D Moher","year":"2009","unstructured":"Moher D et al (2009) Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. BMJ 339:b2535. https:\/\/doi.org\/10.1136\/bmj.b2535","journal-title":"BMJ"},{"key":"2695_CR14","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1016\/j.wneu.2023.11.065","volume":"182","author":"Z Lan","year":"2024","unstructured":"Lan Z et al (2024) Impact of prevention strategies on quality of life in patients with osteoarthritis: A Meta-Analysis of Randomized Controlled Trials. World Neurosurg 182:159-164.e154. https:\/\/doi.org\/10.1016\/j.wneu.2023.11.065","journal-title":"World Neurosurg"},{"key":"2695_CR15","doi-asserted-by":"publisher","first-page":"603","DOI":"10.1007\/s10654-010-9491-z","volume":"25","author":"A Stang","year":"2010","unstructured":"Stang A (2010) Critical evaluation of the Newcastle-Ottawa scale for the assessment of the quality of nonrandomized studies in meta-analyses. Eur J Epidemiol 25:603\u2013605. https:\/\/doi.org\/10.1007\/s10654-010-9491-z","journal-title":"Eur J Epidemiol"},{"key":"2695_CR16","doi-asserted-by":"publisher","first-page":"2073","DOI":"10.1038\/s41433-022-02108-0","volume":"36","author":"S Parpia","year":"2022","unstructured":"Parpia S et al (2022) Sensitivity analysis in clinical trials: three criteria for a valid sensitivity analysis. Eye (Lond) 36:2073\u20132074. https:\/\/doi.org\/10.1038\/s41433-022-02108-0","journal-title":"Eye (Lond)"},{"key":"2695_CR17","doi-asserted-by":"publisher","first-page":"597","DOI":"10.1136\/bmj.333.7568.597","volume":"333","author":"J Lau","year":"2006","unstructured":"Lau J et al (2006) The case of the misleading funnel plot. BMJ 333:597\u2013600. https:\/\/doi.org\/10.1136\/bmj.333.7568.597","journal-title":"BMJ"},{"key":"2695_CR18","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1136\/bmj.327.7414.557","volume":"327","author":"JP Higgins","year":"2003","unstructured":"Higgins JP et al (2003) Measuring inconsistency in meta-analyses. BMJ 327:557\u2013560. https:\/\/doi.org\/10.1136\/bmj.327.7414.557","journal-title":"BMJ"},{"key":"2695_CR19","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1111\/os.12430","volume":"11","author":"SJ Duan","year":"2019","unstructured":"Duan SJ et al (2019) Robot-assisted percutaneous cannulated screw fixation of femoral neck fractures: preliminary clinical results. Orthop Surg 11:34\u201341. https:\/\/doi.org\/10.1111\/os.12430","journal-title":"Orthop Surg"},{"key":"2695_CR20","doi-asserted-by":"publisher","DOI":"10.2196\/24164","volume":"9","author":"L Wan","year":"2021","unstructured":"Wan L et al (2021) Application of robot positioning for cannulated screw internal fixation in the treatment of femoral neck fracture: retrospective study. JMIR Med Inform 9:e24164. https:\/\/doi.org\/10.2196\/24164","journal-title":"JMIR Med Inform"},{"key":"2695_CR21","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1186\/s13018-023-04070-3","volume":"18","author":"X Wang","year":"2023","unstructured":"Wang X et al (2023) Robotic-assisted systems for the safe and reliable treatment of femoral neck fractures: retrospective cohort study. J Orthop Surg Res 18:633. https:\/\/doi.org\/10.1186\/s13018-023-04070-3","journal-title":"J Orthop Surg Res"},{"key":"2695_CR22","doi-asserted-by":"publisher","first-page":"864","DOI":"10.1111\/os.12548","volume":"11","author":"XD Wang","year":"2019","unstructured":"Wang XD et al (2019) Treatment of femoral neck fractures with cannulated screw invasive internal fixation assisted by orthopaedic surgery robot positioning system. Orthop Surg 11:864\u2013872. https:\/\/doi.org\/10.1111\/os.12548","journal-title":"Orthop Surg"},{"key":"2695_CR23","doi-asserted-by":"publisher","DOI":"10.1016\/j.exger.2024.112565","volume":"196","author":"Z Yin","year":"2024","unstructured":"Yin Z et al (2024) Comparison of the surgical efficacy of robot-assisted and freehand nail placement in the treatment of sarcopenia combined with femoral neck fractures younger than 65 years. Exp Gerontol 196:112565. https:\/\/doi.org\/10.1016\/j.exger.2024.112565","journal-title":"Exp Gerontol"},{"key":"2695_CR24","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1111\/os.12915","volume":"13","author":"ZD Zhu","year":"2021","unstructured":"Zhu ZD et al (2021) tirobot-assisted percutaneous cannulated screw fixation in the treatment of femoral neck fractures: a minimum 2-year follow-up of 50 patients. Orthop Surg 13:244\u2013252. https:\/\/doi.org\/10.1111\/os.12915","journal-title":"Orthop Surg"},{"key":"2695_CR25","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1186\/s12938-023-01083-1","volume":"22","author":"S Huang","year":"2023","unstructured":"Huang S et al (2023) Comparison of femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis. Biomed Eng Online 22:20. https:\/\/doi.org\/10.1186\/s12938-023-01083-1","journal-title":"Biomed Eng Online"},{"key":"2695_CR26","doi-asserted-by":"publisher","first-page":"215145932311641","DOI":"10.1177\/21514593231164105","volume":"14","author":"V Labmayr","year":"2023","unstructured":"Labmayr V et al (2023) Reoperation rate of internal fixation for femoral neck fractures in the elderly - a retrospective follow-up study in 116 patients with an exploration of risk factors. Geriatr Orthop Surg Rehabil 14:21514593231164104. https:\/\/doi.org\/10.1177\/21514593231164105","journal-title":"Geriatr Orthop Surg Rehabil"},{"key":"2695_CR27","first-page":"3906","volume":"124","author":"JQ Wang","year":"2011","unstructured":"Wang JQ et al (2011) Computer-assisted navigation systems for insertion of cannulated screws in femoral neck fractures: a comparison of bi-planar robot navigation with optoelectronic navigation in a Synbone hip model trial. Chin Med J (Engl) 124:3906\u20133911","journal-title":"Chin Med J (Engl)"},{"key":"2695_CR28","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1111\/os.12451","volume":"11","author":"XB Wu","year":"2019","unstructured":"Wu XB et al (2019) Guidance for the treatment of femoral neck fracture with precise minimally invasive internal fixation based on the orthopaedic surgery robot positioning system. Orthop Surg 11:335\u2013340. https:\/\/doi.org\/10.1111\/os.12451","journal-title":"Orthop Surg"},{"key":"2695_CR29","doi-asserted-by":"publisher","DOI":"10.3791\/64267","author":"Y Cong","year":"2023","unstructured":"Cong Y et al (2023) Orthopedic robot-assisted femoral neck system in the treatment of femoral neck fracture. J Vis Exp. https:\/\/doi.org\/10.3791\/64267","journal-title":"J Vis Exp"}],"container-title":["Journal of Robotic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11701-025-02695-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11701-025-02695-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11701-025-02695-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,4]],"date-time":"2026-01-04T01:23:46Z","timestamp":1767489826000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11701-025-02695-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,26]]},"references-count":29,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["2695"],"URL":"https:\/\/doi.org\/10.1007\/s11701-025-02695-6","relation":{},"ISSN":["1863-2491"],"issn-type":[{"value":"1863-2491","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,26]]},"assertion":[{"value":"12 August 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 August 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 August 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interests"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Human and animal rights"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}],"article-number":"515"}}