{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,6]],"date-time":"2026-11-06T22:12:28Z","timestamp":1794003148757,"version":"4.8.0"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,12,11]],"date-time":"2025-12-11T00:00:00Z","timestamp":1765411200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,12,11]],"date-time":"2025-12-11T00:00:00Z","timestamp":1765411200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Robotic Surg"],"DOI":"10.1007\/s11701-025-03025-6","type":"journal-article","created":{"date-parts":[[2025,12,11]],"date-time":"2025-12-11T03:58:45Z","timestamp":1765425525000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Robot-assisted total hip arthroplasty: optimal and rapid preservation of femoral offset and operated lower limb length"],"prefix":"10.1007","volume":"20","author":[{"given":"Fanny","family":"Delaigue","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Louis","family":"Guidoni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Flore","family":"Devriese","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pascal","family":"Bizot","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Axelle","family":"Portet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jules","family":"Descamps","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R\u00e9my","family":"Nizard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pierre-Alban","family":"Bouch\u00e9","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,12,11]]},"reference":[{"issue":"9597","key":"3025_CR1","doi-asserted-by":"publisher","first-page":"1508","DOI":"10.1016\/S0140-6736(07)60457-7","volume":"370","author":"ID Learmonth","year":"2007","unstructured":"Learmonth ID, Young C, Rorabeck C (2007) The operation of the century: total hip replacement. Lancet 370(9597):1508\u20131519. https:\/\/doi.org\/10.1016\/S0140-6736(07)60457-7","journal-title":"Lancet"},{"issue":"2","key":"3025_CR2","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1016\/j.arth.2013.06.026","volume":"29","author":"CL Harrison","year":"2014","unstructured":"Harrison CL, Thomson AI, Cutts S, Rowe PJ, Riches PE (2014) Research synthesis of recommended acetabular cup orientations for total hip arthroplasty. J Arthroplasty 29(2):377\u2013382. https:\/\/doi.org\/10.1016\/j.arth.2013.06.026","journal-title":"J Arthroplasty"},{"issue":"10","key":"3025_CR3","doi-asserted-by":"publisher","first-page":"2958","DOI":"10.1016\/j.arth.2017.04.044","volume":"32","author":"DC Patterson","year":"2017","unstructured":"Patterson DC, Grelsamer RP, Bronson MJ, Moucha CS (2017) Lawsuits after primary and revision total hip arthroplasties: A malpractice claims analysis. J Arthroplasty 32(10):2958\u20132962. https:\/\/doi.org\/10.1016\/j.arth.2017.04.044","journal-title":"J Arthroplasty"},{"issue":"9","key":"3025_CR4","doi-asserted-by":"publisher","first-page":"1890","DOI":"10.1016\/j.arth.2016.02.055","volume":"31","author":"I Zengerink","year":"2016","unstructured":"Zengerink I, Reijman M, Mathijssen NMC, Eikens-Jansen MP, Bos PK (2016) Hip arthroplasty malpractice claims in the netherlands: closed claim study 2000\u20132012. J Arthroplasty 31(9):1890\u20131893e4. https:\/\/doi.org\/10.1016\/j.arth.2016.02.055","journal-title":"J Arthroplasty"},{"issue":"1","key":"3025_CR5","doi-asserted-by":"publisher","first-page":"128","DOI":"10.2106\/JBJS.H.00155","volume":"91","author":"KJ Bozic","year":"2009","unstructured":"Bozic KJ, Kurtz SM, Lau E, Ong K, Vail TP, Berry DJ (2009) The epidemiology of revision total hip arthroplasty in the united States. J Bone Joint Surg Am 91(1):128\u2013133. https:\/\/doi.org\/10.2106\/JBJS.H.00155","journal-title":"J Bone Joint Surg Am"},{"issue":"7","key":"3025_CR6","doi-asserted-by":"publisher","first-page":"887","DOI":"10.1016\/j.arth.2004.07.001","volume":"20","author":"VK Sarin","year":"2005","unstructured":"Sarin VK, Pratt WR, Bradley GW (2005) Accurate femur repositioning is critical during intraoperative total hip arthroplasty length and offset assessment. J Arthroplasty 20(7):887\u2013891. https:\/\/doi.org\/10.1016\/j.arth.2004.07.001","journal-title":"J Arthroplasty"},{"issue":"2","key":"3025_CR7","doi-asserted-by":"publisher","first-page":"217","DOI":"10.2106\/00004623-197860020-00014","volume":"60","author":"GE Lewinnek","year":"1978","unstructured":"Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR (1978) Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am 60(2):217\u2013220","journal-title":"J Bone Joint Surg Am"},{"issue":"2","key":"3025_CR8","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1007\/s11999-010-1487-1","volume":"469","author":"MC Callanan","year":"2011","unstructured":"Callanan MC, Jarrett B, Bragdon CR et al (2011) The John Charnley award: risk factors for cup malpositioning: quality improvement through a joint registry at a tertiary hospital. Clin Orthop Relat Res 469(2):319\u2013329. https:\/\/doi.org\/10.1007\/s11999-010-1487-1","journal-title":"Clin Orthop Relat Res"},{"issue":"3","key":"3025_CR9","doi-asserted-by":"publisher","first-page":"282","DOI":"10.1054\/arth.2002.30286","volume":"17","author":"BM Jolles","year":"2002","unstructured":"Jolles BM, Zangger P, Leyvraz PF (2002) Factors predisposing to dislocation after primary total hip arthroplasty: a multivariate analysis. J Arthroplasty 17(3):282\u2013288. https:\/\/doi.org\/10.1054\/arth.2002.30286","journal-title":"J Arthroplasty"},{"key":"3025_CR10","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1051\/sicotj\/2020041","volume":"6","author":"P Kouyoumdjian","year":"2020","unstructured":"Kouyoumdjian P, Mansour J, Assi C, Caton J, Lustig S, Coulomb R (2020) Current concepts in robotic total hip arthroplasty. SICOT J 6:45. https:\/\/doi.org\/10.1051\/sicotj\/2020041","journal-title":"SICOT J"},{"issue":"7","key":"3025_CR11","doi-asserted-by":"publisher","first-page":"1349","DOI":"10.1097\/CORR.0000000000003473","volume":"483","author":"A Ramesh","year":"2025","unstructured":"Ramesh A, Henckel J, Lim X, Tompsett P, Hart A, Di Laura A (2025) What is the functional spinopelvic relationship in three dimensions? A CT and EOS study. Clin Orthop Relat Res 483(7):1349\u20131359. https:\/\/doi.org\/10.1097\/CORR.0000000000003473","journal-title":"Clin Orthop Relat Res"},{"issue":"6","key":"3025_CR12","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1302\/2633-1462.26.BJO-2021-0042.R1","volume":"2","author":"N Kolodychuk","year":"2021","unstructured":"Kolodychuk N, Su E, Alexiades MM, Ren R, Ojard C, Waddell BS (2021) Can robotic technology mitigate the learning curve of total hip arthroplasty? Bone Jt Open 2(6):365\u2013370. https:\/\/doi.org\/10.1302\/2633-1462.26.BJO-2021-0042.R1","journal-title":"Bone Jt Open"},{"issue":"4","key":"3025_CR13","doi-asserted-by":"publisher","first-page":"e2518","DOI":"10.1002\/rcs.2518","volume":"19","author":"GBJ Buchan","year":"2023","unstructured":"Buchan GBJ, Hecht CJ, Lawrie CM, Sculco PK, Kamath AF (2023) The learning curve for a novel, fluoroscopy-based robotic-assisted total hip arthroplasty system. Int J Med Robot 19(4):e2518. https:\/\/doi.org\/10.1002\/rcs.2518","journal-title":"Int J Med Robot"},{"issue":"1","key":"3025_CR14","doi-asserted-by":"publisher","first-page":"756","DOI":"10.1186\/s12891-023-06895-9","volume":"24","author":"TF Zhuang","year":"2023","unstructured":"Zhuang TF, Wu CJ, Luo SM et al (2023) Preliminary study of short-term outcomes and learning curves of robotic-assisted THA: comparison between closed platform robotic system and open platform robotic system. BMC Musculoskelet Disord 24(1):756. https:\/\/doi.org\/10.1186\/s12891-023-06895-9","journal-title":"BMC Musculoskelet Disord"},{"issue":"7","key":"3025_CR15","doi-asserted-by":"publisher","first-page":"1498","DOI":"10.1111\/os.13334","volume":"14","author":"DH Guo","year":"2022","unstructured":"Guo DH, Li XM, Ma SQ, Zhao YC, Qi C, Xue Y (2022) Total hip arthroplasty with robotic arm assistance for precise cup positioning: A Case-Control study. Orthop Surg 14(7):1498\u20131505. https:\/\/doi.org\/10.1111\/os.13334","journal-title":"Orthop Surg"},{"issue":"1","key":"3025_CR16","doi-asserted-by":"publisher","first-page":"342","DOI":"10.1186\/s12891-024-07474-2","volume":"25","author":"H Sun","year":"2024","unstructured":"Sun H, Lu H, Xiao Q, Ding Z, Luo Z, Zhou Z (2024) The learning curve of a novel seven-axis robot-assisted total hip arthroplasty system: a randomized controlled trial. BMC Musculoskelet Disord 25(1):342. https:\/\/doi.org\/10.1186\/s12891-024-07474-2","journal-title":"BMC Musculoskelet Disord"},{"issue":"3","key":"3025_CR17","doi-asserted-by":"publisher","first-page":"311","DOI":"10.1177\/1120700019889334","volume":"31","author":"B Kayani","year":"2021","unstructured":"Kayani B, Konan S, Huq SS, Ibrahim MS, Ayuob A, Haddad FS (2021) The learning curve of robotic-arm assisted acetabular cup positioning during total hip arthroplasty. Hip Int 31(3):311\u2013319. https:\/\/doi.org\/10.1177\/1120700019889334","journal-title":"Hip Int"},{"key":"3025_CR18","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1016\/j.ijsu.2020.03.067","volume":"77","author":"X Kong","year":"2020","unstructured":"Kong X, Yang M, Jerabek S, Zhang G, Chen J, Chai W (2020) A retrospective study comparing a single surgeon\u2019s experience on manual versus robot-assisted total hip arthroplasty after the learning curve of the latter procedure - A cohort study. Int J Surg 77:174\u2013180. https:\/\/doi.org\/10.1016\/j.ijsu.2020.03.067","journal-title":"Int J Surg"},{"issue":"1","key":"3025_CR19","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1186\/s13018-023-03735-3","volume":"18","author":"R Tian","year":"2023","unstructured":"Tian R, Duan X, Kong N, Wang K, Yang P (2023) Precise acetabular positioning, discrepancy in leg length, and hip offset using a new seven-axis robot-assisted total hip arthroplasty system requires no learning curve: a retrospective study. J Orthop Surg Res 18(1):236. https:\/\/doi.org\/10.1186\/s13018-023-03735-3","journal-title":"J Orthop Surg Res"},{"issue":"1","key":"3025_CR20","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1016\/j.arth.2014.08.003","volume":"30","author":"JM Redmond","year":"2015","unstructured":"Redmond JM, Gupta A, Hammarstedt JE, Petrakos AE, Finch NA, Domb BG (2015) The learning curve associated with robotic-assisted total hip arthroplasty. J Arthroplasty 30(1):50\u201354. https:\/\/doi.org\/10.1016\/j.arth.2014.08.003","journal-title":"J Arthroplasty"},{"issue":"8","key":"3025_CR21","doi-asserted-by":"publisher","first-page":"2569","DOI":"10.3390\/jcm9082569","volume":"9","author":"H Haffer","year":"2020","unstructured":"Haffer H, Adl Amini D, Perka C, Pumberger M (2020) The impact of spinopelvic mobility on arthroplasty: implications for hip and spine surgeons. J Clin Med 9(8):2569. https:\/\/doi.org\/10.3390\/jcm9082569","journal-title":"J Clin Med"},{"issue":"1 Supple A","key":"3025_CR22","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1302\/0301-620X.99B1.BJJ-2016-0415.R1","volume":"99\u2013B","author":"M Stefl","year":"2017","unstructured":"Stefl M, Lundergan W, Heckmann N et al (2017) Spinopelvic mobility and acetabular component position for total hip arthroplasty. Bone Joint J 99\u2013B(1 Supple A):37\u201345. https:\/\/doi.org\/10.1302\/0301-620X.99B1.BJJ-2016-0415.R1","journal-title":"Bone Joint J"},{"issue":"7S","key":"3025_CR23","doi-asserted-by":"publisher","first-page":"S540","DOI":"10.1016\/j.arth.2022.02.038","volume":"37","author":"CS Sicat","year":"2022","unstructured":"Sicat CS, Buchalter DB, Luthringer TA, Schwarzkopf R, Vigdorchik JM (2022) Intraoperative technology use improves accuracy of functional safe zone targeting in total hip arthroplasty. J Arthroplasty 37(7S):S540\u2013S545. https:\/\/doi.org\/10.1016\/j.arth.2022.02.038","journal-title":"J Arthroplasty"},{"issue":"2","key":"3025_CR24","doi-asserted-by":"publisher","first-page":"230949901984887","DOI":"10.1177\/2309499019848871","volume":"27","author":"T Kamenaga","year":"2019","unstructured":"Kamenaga T, Hayashi S, Hashimoto S et al (2019) Accuracy of cup orientation and learning curve of the accelerometer-based portable navigation system for total hip arthroplasty in the supine position. J Orthop Surg (Hong Kong) 27(2):2309499019848871. https:\/\/doi.org\/10.1177\/2309499019848871","journal-title":"J Orthop Surg (Hong Kong)"},{"issue":"10 Suppl","key":"3025_CR25","doi-asserted-by":"publisher","first-page":"14","DOI":"10.3928\/01477447-20090915-52","volume":"32","author":"F Thorey","year":"2009","unstructured":"Thorey F, Klages P, Lerch M, Floerkemeier T, Windhagen H, von Lewinski G (2009) Cup positioning in primary total hip arthroplasty using an imageless navigation device: is there a learning curve? Orthopedics 32(10 Suppl):14\u201317. https:\/\/doi.org\/10.3928\/01477447-20090915-52","journal-title":"Orthopedics"},{"issue":"7 Suppl 3","key":"3025_CR26","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1016\/j.arth.2005.04.024","volume":"20","author":"RL Wixson","year":"2005","unstructured":"Wixson RL, MacDonald MA (2005) Total hip arthroplasty through a minimal posterior approach using imageless computer-assisted hip navigation. J Arthroplasty 20(7 Suppl 3):51\u201356. https:\/\/doi.org\/10.1016\/j.arth.2005.04.024","journal-title":"J Arthroplasty"},{"key":"3025_CR27","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1016\/j.artd.2022.06.016","volume":"17","author":"NL Kolodychuk","year":"2022","unstructured":"Kolodychuk NL, Raszewski JA, Gladnick BP, Kitziger KJ, Peters PC, Waddell BS (2022) Handheld navigation improves accuracy in direct anterior total hip replacement. Arthroplast Today 17:58\u201365. https:\/\/doi.org\/10.1016\/j.artd.2022.06.016","journal-title":"Arthroplast Today"},{"issue":"4","key":"3025_CR28","doi-asserted-by":"publisher","first-page":"523","DOI":"10.1007\/s13534-023-00312-9","volume":"13","author":"K Kim","year":"2023","unstructured":"Kim K, Kwon S, Kwon J, Hwang J (2023) A review of robotic-assisted total hip arthroplasty. Biomed Eng Lett 13(4):523\u2013535. https:\/\/doi.org\/10.1007\/s13534-023-00312-9","journal-title":"Biomed Eng Lett"},{"issue":"1","key":"3025_CR29","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1007\/s11701-024-01855-4","volume":"18","author":"CJ Hecht Ii","year":"2024","unstructured":"Hecht Ii CJ, Porto JR, Sanghvi PA, Homma Y, Sculco PK, Kamath AF (2024) Navigating the learning curve: assessing caseload and comparing outcomes before and after the learning curve of computer-navigated total hip arthroplasty. J Robot Surg 18(1):104. https:\/\/doi.org\/10.1007\/s11701-024-01855-4","journal-title":"J Robot Surg"},{"issue":"1","key":"3025_CR30","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1016\/j.arth.2016.06.039","volume":"32","author":"E Kamara","year":"2017","unstructured":"Kamara E, Robinson J, Bas MA, Rodriguez JA, Hepinstall MS (2017) Adoption of robotic vs fluoroscopic guidance in total hip arthroplasty: is acetabular positioning improved in the learning curve? J Arthroplasty 32(1):125\u2013130. https:\/\/doi.org\/10.1016\/j.arth.2016.06.039","journal-title":"J Arthroplasty"},{"issue":"3","key":"3025_CR31","doi-asserted-by":"publisher","first-page":"e1990","DOI":"10.1002\/rcs.1990","volume":"15","author":"PF Han","year":"2019","unstructured":"Han PF, Chen CL, Zhang ZL et al (2019) Robotics-assisted versus conventional manual approaches for total hip arthroplasty: A systematic review and meta-analysis of comparative studies. Int J Med Robot 15(3):e1990. https:\/\/doi.org\/10.1002\/rcs.1990","journal-title":"Int J Med Robot"}],"container-title":["Journal of Robotic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11701-025-03025-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11701-025-03025-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11701-025-03025-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,11]],"date-time":"2025-12-11T03:58:45Z","timestamp":1765425525000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11701-025-03025-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,11]]},"references-count":31,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["3025"],"URL":"https:\/\/doi.org\/10.1007\/s11701-025-03025-6","relation":{},"ISSN":["1863-2491"],"issn-type":[{"value":"1863-2491","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,11]]},"assertion":[{"value":"20 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 November 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 December 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"82"}}