{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,12]],"date-time":"2026-02-12T04:01:56Z","timestamp":1770868916638,"version":"3.50.1"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,2,12]],"date-time":"2026-02-12T00:00:00Z","timestamp":1770854400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,2,12]],"date-time":"2026-02-12T00:00:00Z","timestamp":1770854400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Robotic Surg"],"DOI":"10.1007\/s11701-026-03202-1","type":"journal-article","created":{"date-parts":[[2026,2,12]],"date-time":"2026-02-12T03:02:04Z","timestamp":1770865324000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Artificial intelligence-based waste detection in robotic surgery: a pilot validation study of computer vision technology"],"prefix":"10.1007","volume":"20","author":[{"given":"Alexis","family":"Sanchez","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Luis","family":"Herrera","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andre","family":"Teixeira","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Manoel","family":"Galvao-Neto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Omaira","family":"Rodriguez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Laura","family":"Brattain","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Antonio","family":"Caycedo-Marulanda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jesus","family":"Alvarez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lillian","family":"Aguirre","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,2,12]]},"reference":[{"issue":"2","key":"3202_CR1","doi-asserted-by":"publisher","first-page":"405","DOI":"10.1007\/s11701-022-01430-9","volume":"17","author":"L Herrera","year":"2023","unstructured":"Herrera L, Escalon J, Johnston M, Sanchez A, Sanchez R, Mogollon I (2023) Development of a robot-assisted thoracic surgery (RATS) program. Lessons learned after 2500 case. J Robot Surg 17(2):405\u2013411","journal-title":"J Robot Surg"},{"issue":"3","key":"3202_CR2","doi-asserted-by":"publisher","first-page":"923","DOI":"10.1007\/s11701-022-01489-4","volume":"17","author":"A Teixeira","year":"2023","unstructured":"Teixeira A, Jawad M, Ghanem M, Sanchez A, Inchausti C, Mogollon I (2023) Robot-assisted duodenal switch with davinci xi: surgical technique and analysis of a single-insitution experience of 661 cases. J Robot Surg 17(3):923\u2013931","journal-title":"J Robot Surg"},{"key":"3202_CR3","doi-asserted-by":"publisher","first-page":"1142","DOI":"10.1016\/j.surg.2021.12.032","volume":"171","author":"M Meyer","year":"2022","unstructured":"Meyer M, Chafitz T, Wang K, Alamgir N, Malapati P, Gander J, Ward D, Gandhi S (2022) Surgeons\u2019 perspectives on operating room waste: multicenter survey. Surgery 171:1142\u20131147","journal-title":"Surgery"},{"key":"3202_CR4","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1016\/j.ijsu.2018.02.004","volume":"53","author":"V Chasseigne","year":"2018","unstructured":"Chasseigne V, Leguelinel-Blache G, Nguyen T, de Tayrac R, Prudhomme M, Kinowski J, Costa P (2018) Assessing the cost of diposable and reusable supplies wasted during surgeries. Int J Surg 53:18\u201323","journal-title":"Int J Surg"},{"issue":"5","key":"3202_CR5","doi-asserted-by":"publisher","first-page":"2059","DOI":"10.1007\/s11701-023-01606-x","volume":"17","author":"A Sanchez","year":"2023","unstructured":"Sanchez A, Herrera L, Teixeira A, Cheatham M, Gibson D, Lam V, Guevara O (2023) Improving efficiency and reducing costs in robotic surgery: a lean six Sigma approach to optimize turnover time. J Robot Surg 17(5):2059\u20132064","journal-title":"J Robot Surg"},{"issue":"1","key":"3202_CR6","first-page":"163","volume":"17","author":"A Sanchez","year":"2023","unstructured":"Sanchez A, Herrera L, Teixeira A, Mogollon I, Inchausti C, Gibson D, Stuart M, Crespo M (2023) Robotic surgery: financial impact of surgical trays optimization in bariatric and thoracic surgery. J Robot Surg 17(1):163\u2013167","journal-title":"J Robot Surg"},{"issue":"2","key":"3202_CR7","doi-asserted-by":"publisher","first-page":"620","DOI":"10.3171\/2016.2.JNS152442","volume":"126","author":"CC Zygourakis","year":"2017","unstructured":"Zygourakis CC, Yoon S, Valencia V, Boscardin C, Moriates C, Gonzales R, Lawton MT (2017) Operating room waste: disposable supply utilization in neurosurgical procedures. J Neurosurg 126(2):620\u2013625","journal-title":"J Neurosurg"},{"key":"3202_CR8","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1016\/j.sopen.2023.07.025","volume":"15","author":"N Goldfield","year":"2023","unstructured":"Goldfield N, Malapati P, Chafitz T, Saravanapavan Y, Alamgir N, Gander J, Meyer M (2023) Sterile surgical supply waste identification using asynchronous analysis: pediatric surgery QI pilot. Surg Open Sci 15:32\u201337","journal-title":"Surg Open Sci"},{"issue":"1","key":"3202_CR9","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1109\/TMRB.2020.3040002","volume":"3","author":"L Kennedy-Metz","year":"2022","unstructured":"Kennedy-Metz L, Mascagni P, Torralba A, Dias R, Perona O, Shah J, Padoy N, Zenati M (2022) Computer vision in the operating room: opportunities and caveats. IEEE Trans Med Robot Bionics 3(1):2\u201310","journal-title":"IEEE Trans Med Robot Bionics"},{"key":"3202_CR10","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1016\/j.media.2018.05.001","volume":"47","author":"A Hajj","year":"2018","unstructured":"Hajj A, Lamard M, Conze P, Cochener B, Quellec G (2018) Monitoring tool usage in surgery videos using boosted convolutional and recurrent neural networks. Med Image Anal 47:203\u2013218","journal-title":"Med Image Anal"},{"issue":"1","key":"3202_CR11","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1002\/ags3.12513","volume":"6","author":"D Kitaguchi","year":"2022","unstructured":"Kitaguchi D, Takeshita N, Matsuzaki H, Takano H, Owada Y, Enomoto T, Oda T, Miura H, Yamanashi T, Watanabe M, Sato D, Okamoto T, Takamatsu M, Maehara Y, Hashizume M, Ito M (2022) Artificial intelligence-based computer vision in surgery: recent advances and future perspectives. Ann Gastroenterol Surg 6(1):29\u201336","journal-title":"Ann Gastroenterol Surg"},{"issue":"1","key":"3202_CR12","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1007\/s11701-025-02436-9","volume":"19","author":"A Sanchez","year":"2025","unstructured":"Sanchez A, Teixeira A, Ghanem M, Herrera L (2025) Design and implementation of a composite performance score to drive cost efficiency in robotic-assisted surgery: the Orlando score. J Robot Surg 19(1):273","journal-title":"J Robot Surg"},{"issue":"11","key":"3202_CR13","doi-asserted-by":"publisher","first-page":"1104","DOI":"10.1097\/DCR.0000000000000463","volume":"58","author":"MJ Guzman","year":"2015","unstructured":"Guzman MJ, Gitelis ME, Linn JG et al (2015) A model of cost reduction and standardization: improved cost savings while maintaining the quality of care. Dis Colon Rectum 58(11):1104\u20131107","journal-title":"Dis Colon Rectum"},{"issue":"20","key":"3202_CR14","doi-asserted-by":"publisher","first-page":"2765","DOI":"10.1001\/jama.1992.03480200073027","volume":"267","author":"M Tieszen","year":"1992","unstructured":"Tieszen M, Gruenberg J, James C (1992) A quantitative, qualitative, and critical assessment of surgical waste: surgeons venture through the trash can. JAMA 267(20):2765\u20132768","journal-title":"JAMA"},{"key":"3202_CR15","first-page":"10073","volume":"15","author":"R Simona","year":"2019","unstructured":"Simona R, Canacarib E, Gamboac K, Giurinid J (2019) Or waste reduction. Periop Care Oper Room Manag 15:10073","journal-title":"Periop Care Oper Room Manag"},{"issue":"2","key":"3202_CR16","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1001\/archsurg.2010.343","volume":"146","author":"G Kwakye","year":"2011","unstructured":"Kwakye G, Brat G, Makary M (2011) Green surgical practices for healthcare. Arch Surg 146(2):131\u2013136","journal-title":"Arch Surg"},{"key":"3202_CR17","doi-asserted-by":"publisher","DOI":"10.1016\/j.cmpb.2022.106888","volume":"221","author":"Z Han","year":"2022","unstructured":"Han Z, Huang H, Fan Q, Li Y, Li Y, Chen X (2022) SMD-YOLO: an efficient and lightweight detection method for mask wearing status during the COVID-19 pandemic. Comput Methods Programs Biomed 221:106888","journal-title":"Comput Methods Programs Biomed"},{"issue":"1","key":"3202_CR18","first-page":"1","volume":"4","author":"Z Ahmed","year":"2024","unstructured":"Ahmed Z, Sadat S (2024) Performance analysis of YOLO architectures for surgical waste detection in post-COVID019 medical waste management. MJSAT 4(1):1\u20139","journal-title":"MJSAT"},{"issue":"1","key":"3202_CR19","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1186\/s13037-024-00406-y","volume":"18","author":"E Deol","year":"2024","unstructured":"Deol E, Henning G, Basourakos S, Vasdev R, Sharma V, Kavoussi N, Jeffrey R, Leibovich B, Boorjian S, Khanna A (2024) Artificial intelligence model for automated surgical instrument detection and counting: an experimental proof-of-concept study. Patient Saf Surg 18(1):24","journal-title":"Patient Saf Surg"}],"container-title":["Journal of Robotic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11701-026-03202-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11701-026-03202-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11701-026-03202-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,12]],"date-time":"2026-02-12T03:02:08Z","timestamp":1770865328000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11701-026-03202-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,12]]},"references-count":19,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["3202"],"URL":"https:\/\/doi.org\/10.1007\/s11701-026-03202-1","relation":{},"ISSN":["1863-2491"],"issn-type":[{"value":"1863-2491","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,12]]},"assertion":[{"value":"26 December 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 January 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 February 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"This project was categorized as a quality improvement initiative, focusing on enhancing operational efficiency and cost management within robotic surgery. It did not involve human research, interventions, or the collection of new data involving human subjects, nor did it require the handling of data containing Protected Health Information (PHI); therefore, Institutional Review Board (IRB) approval was not required.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}}],"article-number":"247"}}