{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T03:01:56Z","timestamp":1780455716201,"version":"3.54.1"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T00:00:00Z","timestamp":1780444800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T00:00:00Z","timestamp":1780444800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Robotic Surg"],"DOI":"10.1007\/s11701-026-03537-9","type":"journal-article","created":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T02:12:06Z","timestamp":1780452726000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Device-related malfunctions and associated patient harm in robotic-assisted hysterectomy: a 17-year review of the FDA MAUDE database"],"prefix":"10.1007","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0009-0002-1025-1068","authenticated-orcid":false,"given":"Bara M.","family":"Hammadeh","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-3015-3669","authenticated-orcid":false,"given":"Nesreen","family":"Alhamwi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-0420-6516","authenticated-orcid":false,"given":"AlBaraa K.","family":"Mohammad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ayham Mohammad","family":"Hussein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rand Raid Naim","family":"Qwaider","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abdulla","family":"Alzibdeh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,3]]},"reference":[{"issue":"4","key":"3537_CR1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0151470","volume":"11","author":"H Alemzadeh","year":"2016","unstructured":"Alemzadeh H, Raman J, Leveson N, Kalbarczyk Z, Iyer RK (2016) Adverse events in robotic surgery: a retrospective study of 14 years of FDA data. PLoS One 11(4):e0151470. https:\/\/doi.org\/10.1371\/journal.pone.0151470","journal-title":"PLoS One"},{"issue":"2","key":"3537_CR2","doi-asserted-by":"publisher","first-page":"300","DOI":"10.1016\/j.jmig.2021.08.021","volume":"29","author":"J Correa","year":"2022","unstructured":"Correa J, Aribo C, Stuparich M, Nahas S, Cheung C, Behbehani S (2022) Malfunction events in the US FDA MAUDE database: How does robotic gynecologic surgery compare with other specialties? J Minim Invasive Gynecol 29(2):300-307.e1. https:\/\/doi.org\/10.1016\/j.jmig.2021.08.021","journal-title":"J Minim Invasive Gynecol"},{"key":"3537_CR3","doi-asserted-by":"publisher","unstructured":"Robot-Assisted Surgery for Noncancerous Gynecologic Conditions (2020) Obstetrics & Gynecology, 136(3):e22\u2013e30.\u00a0https:\/\/doi.org\/10.1097\/AOG.0000000000004048","DOI":"10.1097\/AOG.0000000000004048"},{"key":"3537_CR4","unstructured":"Manufacturer and User Facility Device Experience (MAUDE) Database, FDA (2026)"},{"issue":"5","key":"3537_CR5","doi-asserted-by":"publisher","first-page":"1976","DOI":"10.1007\/s00464-020-08231-x","volume":"35","author":"F Kanji","year":"2021","unstructured":"Kanji F et al (2021) Work-system interventions in robotic-assisted surgery: a systematic review exploring the gap between challenges and solutions. Surg Endosc 35(5):1976\u20131989. https:\/\/doi.org\/10.1007\/s00464-020-08231-x","journal-title":"Surg Endosc"},{"issue":"1","key":"3537_CR6","doi-asserted-by":"publisher","first-page":"206","DOI":"10.1007\/s00464-020-08258-0","volume":"36","author":"L Cofran","year":"2022","unstructured":"Cofran L et al (2022) Barriers to safety and efficiency in robotic surgery docking. Surg Endosc 36(1):206\u2013215. https:\/\/doi.org\/10.1007\/s00464-020-08258-0","journal-title":"Surg Endosc"},{"issue":"8","key":"3537_CR7","doi-asserted-by":"publisher","first-page":"763","DOI":"10.1093\/bjs\/znac119","volume":"109","author":"H Muaddi","year":"2022","unstructured":"Muaddi H et al (2022) Adverse events following robotic surgery: population-based analysis. Br J Surg 109(8):763\u2013771. https:\/\/doi.org\/10.1093\/bjs\/znac119","journal-title":"Br J Surg"},{"issue":"1","key":"3537_CR8","doi-asserted-by":"publisher","DOI":"10.1007\/s00345-025-05732-z","volume":"43","author":"NM Buffi","year":"2025","unstructured":"Buffi NM et al (2025) Reliability of the da Vinci robotic surgical system: a systematic review and pooled analysis of technical failures. World J Urol 43(1):348. https:\/\/doi.org\/10.1007\/s00345-025-05732-z","journal-title":"World J Urol"},{"key":"3537_CR9","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1016\/j.ejogrb.2021.07.038","volume":"265","author":"G Marchand","year":"2021","unstructured":"Marchand G et al (2021) Systematic review and meta-analysis of all randomized controlled trials comparing gynecologic laparoscopic procedures with and without robotic assistance. Eur J Obstet Gynecol Reprod Biol 265:30\u201338. https:\/\/doi.org\/10.1016\/j.ejogrb.2021.07.038","journal-title":"Eur J Obstet Gynecol Reprod Biol"},{"issue":"7","key":"3537_CR10","doi-asserted-by":"publisher","first-page":"2689","DOI":"10.3390\/jcm15072689","volume":"15","author":"KJ Eoh","year":"2026","unstructured":"Eoh KJ, Hur H, Park JH (2026) Perioperative Outcomes of Robotic Versus Conventional Total Laparoscopic Hysterectomy in Surgically Complex Cases: A Propensity Score-Matched Study. J Clin Med 15(7):2689. https:\/\/doi.org\/10.3390\/jcm15072689","journal-title":"J Clin Med"},{"issue":"6","key":"3537_CR11","doi-asserted-by":"publisher","first-page":"2647","DOI":"10.1007\/s11701-023-01724-6","volume":"17","author":"L Lenfant","year":"2023","unstructured":"Lenfant L et al (2023) Robotic-assisted benign hysterectomy compared with laparoscopic, vaginal, and open surgery: a systematic review and meta-analysis. J Robot Surg 17(6):2647\u20132662. https:\/\/doi.org\/10.1007\/s11701-023-01724-6","journal-title":"J Robot Surg"},{"issue":"3","key":"3537_CR12","doi-asserted-by":"publisher","first-page":"683","DOI":"10.1177\/00187208211068946","volume":"66","author":"K Catchpole","year":"2024","unstructured":"Catchpole K et al (2024) Human factors integration in robotic surgery. Human Factors: The J Human Factors and Ergonomics Soc 66(3):683\u2013700. https:\/\/doi.org\/10.1177\/00187208211068946","journal-title":"Human Factors: The J Human Factors and Ergonomics Soc"},{"issue":"11","key":"3537_CR13","doi-asserted-by":"publisher","first-page":"3599","DOI":"10.1007\/s00268-018-4689-4","volume":"42","author":"J Weber","year":"2018","unstructured":"Weber J, Catchpole K, Becker AJ, Schlenker B, Weigl M (2018) Effects of flow disruptions on mental workload and surgical performance in robotic-assisted surgery. World J Surg 42(11):3599\u20133607. https:\/\/doi.org\/10.1007\/s00268-018-4689-4","journal-title":"World J Surg"},{"key":"3537_CR14","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1016\/j.apergo.2018.02.011","volume":"78","author":"K Catchpole","year":"2019","unstructured":"Catchpole K et al (2019) Human factors in robotic assisted surgery: lessons from studies \u2018in the wild.\u2019 Appl Ergon 78:270\u2013276. https:\/\/doi.org\/10.1016\/j.apergo.2018.02.011","journal-title":"Appl Ergon"},{"issue":"8","key":"3537_CR15","doi-asserted-by":"publisher","first-page":"649","DOI":"10.1089\/end.2018.0802","volume":"33","author":"F Nik-Ahd","year":"2019","unstructured":"Nik-Ahd F, Souders CP, Houman J, Zhao H, Chughtai B, Anger JT (2019) Robotic urologic surgery: trends in Food and Drug Administration-reported adverse events over the last decade. J Endourol 33(8):649\u2013654. https:\/\/doi.org\/10.1089\/end.2018.0802","journal-title":"J Endourol"},{"issue":"11","key":"3537_CR16","doi-asserted-by":"publisher","first-page":"1420","DOI":"10.1001\/jamainternmed.2020.3514","volume":"180","author":"N Tau","year":"2020","unstructured":"Tau N, Shepshelovich D (2020) Assessment of data sources that support US Food and Drug Administration medical devices safety communications. JAMA Intern Med 180(11):1420. https:\/\/doi.org\/10.1001\/jamainternmed.2020.3514","journal-title":"JAMA Intern Med"},{"key":"3537_CR17","doi-asserted-by":"publisher","unstructured":"Assessing and Adopting New Medical Devices for Obstetric and Gynecologic Care (2020) Obstetrics & Gynecology 135(4):985\u2013986. https:\/\/doi.org\/10.1097\/AOG.0000000000003767","DOI":"10.1097\/AOG.0000000000003767"}],"container-title":["Journal of Robotic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11701-026-03537-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11701-026-03537-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11701-026-03537-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T02:12:08Z","timestamp":1780452728000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11701-026-03537-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,3]]},"references-count":17,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["3537"],"URL":"https:\/\/doi.org\/10.1007\/s11701-026-03537-9","relation":{},"ISSN":["1863-2491"],"issn-type":[{"value":"1863-2491","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,3]]},"assertion":[{"value":"25 April 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 May 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"<!--Emphasis Type='Bold' removed-->Conflict of Interest"}},{"value":"This study utilized data obtained from the U.S. Food and Drug Administration\u2019s (FDA) Manufacturer and User Facility Device Experience (MAUDE) database, a publicly accessible repository that contains de-identified reports of adverse events involving medical devices submitted by manufacturers, healthcare professionals, and consumers. As the MAUDE database consists of publicly available, anonymized data and does not include identifiable patient information, this study did not involve human subjects as defined by federal regulations. Accordingly, institutional review board (IRB) approval and informed consent were not required for this study. The research was conducted in accordance with applicable ethical standards and relevant guidelines for studies using publicly available, de-identified datasets.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval and consent to participate"}},{"value":"All authors have been offered the opportunity to read the manuscript and clearly declare and consent for publication after approval.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Generative AI (ChatGPT-5, OpenAI) was used solely for grammar and spelling correction after the drafting was complete. It was not used for conceptualization, scientific argument, reference identification, or data interpretation. The authors are fully responsible for the content. Additionally, NotebookLM (Google Labs) was used for the generation of the visual abstract, no other figures were AI generated and are solely made by RStudio.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"<!--Emphasis Type='Bold' removed-->AI Use Declaration"}}],"article-number":"575"}}