{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T19:22:58Z","timestamp":1792783378347,"version":"4.5.0"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,9,19]],"date-time":"2026-09-19T00:00:00Z","timestamp":1789776000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,9,19]],"date-time":"2026-09-19T00:00:00Z","timestamp":1789776000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Universit\u00e4tsklinikum Schleswig-Holstein - Campus Kiel","id":[{"id":"https:\/\/ror.org\/01tvm6f46","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Robotic Surg"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Surgical smoke from electrocautery limits visibility during robot-assisted oncological surgery by obscuring tumor margins, blood vessels and anatomical landmarks. AI-based smoke removal demonstrated promising technical performance, structured clinical evaluation remains limited. This pilot study examined surgeons\u2019 perceptions of a temporally consistent 3D U-Net applied to intraoperative smoke. Twenty urologists and residents retrospectively assessed ten pairs of endoscopic videos offline, showing original and AI-processed clips. A questionnaire evaluated general impressions (seven items, five-point Likert scale), direct comparisons across four image dimensions, open-ended feedback and overall utility. Visibility of anatomical details and depth perception were rated equal to the smoke-affected original by 75% of participants and slightly better by 25%. Color fidelity was rated equal by 85% and slightly better by 15%. None rated these dimensions worse (0\/20, exact 95% CI 0 to 16.8%), and no participant selected the highest rating. Image stability was rated worse by 20%. Half disagreed that the processed footage appeared clearer. Overall utility was rated positively by 40%, neutrally by 35% and negatively by 25%. In this small, unblinded, single-institution retrospective pilot study, AI processing was not associated with a perceived worsening of anatomical detail, depth perception or color fidelity. However, confidence intervals remain wide and the study was not designed to establish equivalence. Most participants perceived no improvement in image clarity or orientation support. Artifact reduction, real-time performance and blinded multicenter evaluation are required before clinical use.<\/jats:p>","DOI":"10.1007\/s11701-026-03951-z","type":"journal-article","created":{"date-parts":[[2026,9,19]],"date-time":"2026-09-19T08:38:11Z","timestamp":1789807091000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["AI-based smoke removal in robotic urooncologic surgery: a clinical pilot study"],"prefix":"10.1007","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4565-7933","authenticated-orcid":false,"given":"Leonhard","family":"Buck","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Silja","family":"Jan\u00dfen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jakob","family":"Kohler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julian","family":"Risch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anton","family":"Moderegger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniar","family":"Osmonov","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonas","family":"Jarczyk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Axel","family":"Merseburger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kevin","family":"K\u00f6ser","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philipp","family":"Nuhn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Severin","family":"Rodler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,19]]},"reference":[{"key":"3951_CR1","doi-asserted-by":"publisher","first-page":"2617","DOI":"10.1007\/s11701-023-01714-8","volume":"17","author":"J Wang","year":"2023","unstructured":"Wang J, Hu K, Wang Y, Wu Y, Bao E, Wang J et al (2023) Robot-assisted versus open radical prostatectomy: a systematic review and meta-analysis of prospective studies. J Robot Surg 17:2617\u20132631. https:\/\/doi.org\/10.1007\/s11701-023-01714-8","journal-title":"J Robot Surg"},{"key":"3951_CR2","doi-asserted-by":"publisher","first-page":"353","DOI":"10.1111\/bju.16093","volume":"132","author":"GG Calpin","year":"2023","unstructured":"Calpin GG, Ryan FR, McHugh FT, McGuire BB (2023) Comparing the outcomes of open, laparoscopic and robot-assisted partial nephrectomy: a network meta\u2010analysis. BJU Int 132:353\u2013364. https:\/\/doi.org\/10.1111\/bju.16093","journal-title":"BJU Int"},{"key":"3951_CR3","doi-asserted-by":"publisher","first-page":"683","DOI":"10.1590\/s1677-5538.ibju.2024.0191","volume":"50","author":"Z Yang","year":"2024","unstructured":"Yang Z, Dou X, Zhou W, Liu Q (2024) Robot-assisted, laparoscopic and open radical cystectomy for bladder cancer: A systematic review and network meta-analysis. Int Braz J Urol 50:683\u2013702. https:\/\/doi.org\/10.1590\/s1677-5538.ibju.2024.0191","journal-title":"Int Braz J Urol"},{"key":"3951_CR4","doi-asserted-by":"publisher","DOI":"10.1007\/s11701-022-01416-7","author":"A Zahid","year":"2022","unstructured":"Zahid A, Ayyan M, Farooq M, Cheema HA, Shahid A, Naeem F et al (2022) Robotic surgery in comparison to the open and laparoscopic approaches in the field of urology: a systematic review. J Robot Surg. https:\/\/doi.org\/10.1007\/s11701-022-01416-7","journal-title":"J Robot Surg"},{"key":"3951_CR5","doi-asserted-by":"publisher","first-page":"4931","DOI":"10.3390\/cancers13194931","volume":"13","author":"J Hoeppner","year":"2021","unstructured":"Hoeppner J (2021) Robotic Cancer Surg Cancers 13:4931. https:\/\/doi.org\/10.3390\/cancers13194931","journal-title":"Robotic Cancer Surg Cancers"},{"key":"3951_CR6","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1186\/s12938-025-01395-4","volume":"24","author":"X Lin","year":"2025","unstructured":"Lin X, Fan Q, Li R, Chen R, Yang Z, Li Y (2025) Enhancing laparoscopic visibility: efficient surgical smoke clearance innovatively using nebulization technology. Biomed Eng OnLine 24:65. https:\/\/doi.org\/10.1186\/s12938-025-01395-4","journal-title":"Biomed Eng OnLine"},{"key":"3951_CR7","doi-asserted-by":"publisher","first-page":"e70019","DOI":"10.1002\/rcs.70019","volume":"20","author":"J Colan","year":"2024","unstructured":"Colan J, Davila A, Hasegawa Y (2024) Tactile Feedback in Robot-Assisted Minimally Invasive Surgery: A Systematic Review. Int J Med Robot 20:e70019. https:\/\/doi.org\/10.1002\/rcs.70019","journal-title":"Int J Med Robot"},{"key":"3951_CR8","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1177\/15533506211014857","volume":"29","author":"U Bracale","year":"2022","unstructured":"Bracale U, Silvestri V, Pontecorvi E, Russo I, Triassi M, Cassinotti E et al (2022) Smoke Evacuation During Laparoscopic Surgery: A Problem Beyond the COVID-19 Period. A Quantitative Analysis of CO2 Environmental Dispersion Using Different Devices. Surg Innov 29:154\u2013159. https:\/\/doi.org\/10.1177\/15533506211014857","journal-title":"Surg Innov"},{"key":"3951_CR9","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1007\/s11701-026-03181-3","volume":"20","author":"CLDS Saggin","year":"2026","unstructured":"Saggin CLDS, Val\u00e9rio-Alves AP, Bezerra RGA, De Aguiar Portela JME, Viana P, De Melo Sprogis R et al (2026) Low pressure pneumoperitoneum in robotic surgery: a systematic review and meta-analysis. J Robot Surg 20:225. https:\/\/doi.org\/10.1007\/s11701-026-03181-3","journal-title":"J Robot Surg"},{"key":"3951_CR10","doi-asserted-by":"publisher","first-page":"5631","DOI":"10.24875\/CIRU.20000951","volume":"90","author":"S Salazar-Colores","year":"2022","unstructured":"Salazar-Colores S, Moreno HA, Moya U, Ortiz-Echeverri CJ, De La Tavares LA, Flores G (2022) Eliminaci\u00f3n de los efectos de humo en cirug\u00eda laparosc\u00f3pica usando redes antag\u00f3nicas generativas y el principio del canal oscuro. Cir Cir 90:5631. https:\/\/doi.org\/10.24875\/CIRU.20000951","journal-title":"Cir Cir"},{"key":"3951_CR11","doi-asserted-by":"publisher","first-page":"1417","DOI":"10.1007\/s11548-023-02835-z","volume":"18","author":"F Wang","year":"2023","unstructured":"Wang F, Sun X, Li J (2023) Surgical smoke removal via residual Swin transformer network. Int J Comput Assist Radiol Surg 18:1417\u20131427. https:\/\/doi.org\/10.1007\/s11548-023-02835-z","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"3951_CR12","doi-asserted-by":"publisher","first-page":"1615","DOI":"10.1109\/TMI.2019.2953717","volume":"39","author":"L Chen","year":"2020","unstructured":"Chen L, Tang W, John NW, Wan TR, Zhang JJ (2020) De-smokeGCN: Generative Cooperative Networks for Joint Surgical Smoke Detection and Removal. IEEE Trans Med Imaging 39:1615\u20131625. https:\/\/doi.org\/10.1109\/TMI.2019.2953717","journal-title":"IEEE Trans Med Imaging"},{"key":"3951_CR13","doi-asserted-by":"publisher","unstructured":"Ma L, Song H, Zhang X, Liao HA, Smoke Removal Method Based on Combined Data and Modified U-Net for Endoscopic Images (2021). 43rd Annu. Int. Conf. IEEE Eng. Med. Biol. Soc. EMBC, Mexico: IEEE; 2021, pp. 3783\u20136. https:\/\/doi.org\/10.1109\/EMBC46164.2021.9630222","DOI":"10.1109\/EMBC46164.2021.9630222"},{"key":"3951_CR14","doi-asserted-by":"publisher","first-page":"e6320","DOI":"10.1002\/cpe.6320","volume":"33","author":"J Lin","year":"2021","unstructured":"Lin J, Jiang M, Pang Y, Wang H, Chen Z, Yan C et al (2021) A desmoking algorithm for endoscopic images based on improved U-Net model. Concurr Comput Pract Exp 33:e6320. https:\/\/doi.org\/10.1002\/cpe.6320","journal-title":"Concurr Comput Pract Exp"},{"key":"3951_CR15","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1007\/978-3-031-73220-1_18","volume-title":"Comput. Vis. \u2013 ECCV 2024","author":"R Wu","year":"2025","unstructured":"Wu R, Zhang Z, Zhang S, Gou L, Chen H, Zhang L et al (2025) Self-Supervised Video Desmoking for Laparoscopic Surgery. In: Leonardis A, Ricci E, Roth S, Russakovsky O, Sattler T, Varol G (eds) Comput. Vis. \u2013 ECCV 2024, vol 15130. Springer Nature Switzerland, Cham, pp 307\u2013324. https:\/\/doi.org\/10.1007\/978-3-031-73220-1_18."},{"key":"3951_CR16","doi-asserted-by":"publisher","first-page":"3179","DOI":"10.1007\/s11606-021-06737-1","volume":"36","author":"A Sharma","year":"2021","unstructured":"Sharma A, Minh Duc NT, Luu Lam Thang T, Nam NH, Ng SJ, Abbas KS et al (2021) A Consensus-Based Checklist for Reporting of Survey Studies (CROSS). J Gen Intern Med 36:3179\u20133187. https:\/\/doi.org\/10.1007\/s11606-021-06737-1","journal-title":"J Gen Intern Med"},{"key":"3951_CR17","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1007\/978-3-031-98691-8_21","volume-title":"Med. Image Underst. Anal","author":"S Jan\u00dfen","year":"2026","unstructured":"Jan\u00dfen S, Oumeslakht M, K\u00f6ser K (2026) Temporally Consistent Smoke Removal from Endoscopic Video Images. In: Ali S, Hogg DC, Peckham M (eds) Med. Image Underst. Anal, vol 15917. Springer Nature Switzerland, Cham, pp 293\u2013301. https:\/\/doi.org\/10.1007\/978-3-031-98691-8_21."},{"key":"3951_CR18","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1007\/978-3-319-24574-4_28","volume-title":"Med. Image Comput. Comput.-Assist. Interv. \u2013 MICCAI 2015","author":"O Ronneberger","year":"2015","unstructured":"Ronneberger O, Fischer P, Brox T (2015) U-Net: Convolutional Networks for Biomedical Image Segmentation. In: Navab N, Hornegger J, Wells WM, Frangi AF (eds) Med. Image Comput. Comput.-Assist. Interv. \u2013 MICCAI 2015, vol 9351. Springer International Publishing, Cham, pp 234\u2013241. https:\/\/doi.org\/10.1007\/978-3-319-24574-4_28."},{"key":"3951_CR19","doi-asserted-by":"publisher","first-page":"1743","DOI":"10.1001\/jama.1983.03330370053031","volume":"249","author":"JA Hanley","year":"1983","unstructured":"Hanley JA, Lippman-Hand A (1983) If nothing goes wrong, is everything all right? Interpreting zero numerators. JAMA 249:1743\u20131745","journal-title":"JAMA"},{"key":"3951_CR20","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1097\/SLA.0000000000002693","volume":"268","author":"DA Hashimoto","year":"2018","unstructured":"Hashimoto DA, Rosman G, Rus D, Meireles OR (2018) Artificial Intelligence in Surgery: Promises and Perils. Ann Surg 268:70\u201376. https:\/\/doi.org\/10.1097\/SLA.0000000000002693","journal-title":"Ann Surg"},{"key":"3951_CR21","doi-asserted-by":"publisher","first-page":"102306","DOI":"10.1016\/j.media.2021.102306","volume":"76","author":"L Maier-Hein","year":"2022","unstructured":"Maier-Hein L, Eisenmann M, Sarikaya D, M\u00e4rz K, Collins T, Malpani A et al (2022) Surgical data science - from concepts toward clinical translation. Med Image Anal 76:102306. https:\/\/doi.org\/10.1016\/j.media.2021.102306","journal-title":"Med Image Anal"},{"key":"3951_CR22","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1016\/j.jtcvs.2007.08.043","volume":"135","author":"CE Reiley","year":"2008","unstructured":"Reiley CE, Akinbiyi T, Burschka D, Chang DC, Okamura AM, Yuh DD (2008) Effects of visual force feedback on robot-assisted surgical task performance. J Thorac Cardiovasc Surg 135:196\u2013202. https:\/\/doi.org\/10.1016\/j.jtcvs.2007.08.043","journal-title":"J Thorac Cardiovasc Surg"},{"key":"3951_CR23","doi-asserted-by":"publisher","first-page":"3501","DOI":"10.1007\/s00464-026-12681-0","volume":"40","author":"W Chen","year":"2026","unstructured":"Chen W, Fukuda S, Yoshida S, Kobayashi N, Fukada K, Fukunishi M et al (2026) Human-in-the-loop validation of an artificial intelligence-driven real-time prostatic capsule recognition model for nerve-sparing robot-assisted radical prostatectomy. Surg Endosc 40:3501\u20133509. https:\/\/doi.org\/10.1007\/s00464-026-12681-0","journal-title":"Surg Endosc"},{"key":"3951_CR24","doi-asserted-by":"publisher","first-page":"1933","DOI":"10.1007\/s00464-022-09678-w","volume":"37","author":"H Nakanuma","year":"2023","unstructured":"Nakanuma H, Endo Y, Fujinaga A, Kawamura M, Kawasaki T, Masuda T et al (2023) An intraoperative artificial intelligence system identifying anatomical landmarks for laparoscopic cholecystectomy: a prospective clinical feasibility trial (J-SUMMIT-C-01). Surg Endosc 37:1933\u20131942. https:\/\/doi.org\/10.1007\/s00464-022-09678-w","journal-title":"Surg Endosc"},{"key":"3951_CR25","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1093\/toxsci\/kfae005","volume":"198","author":"EH Benaim","year":"2024","unstructured":"Benaim EH, Jaspers I (2024) Surgical smoke and its components, effects, and mitigation: a contemporary review. Toxicol Sci 198:157\u2013168. https:\/\/doi.org\/10.1093\/toxsci\/kfae005","journal-title":"Toxicol Sci"},{"key":"3951_CR26","doi-asserted-by":"publisher","first-page":"4228","DOI":"10.1007\/s00464-018-6169-1","volume":"32","author":"H Harada","year":"2018","unstructured":"Harada H, Kanaji S, Hasegawa H, Yamamoto M, Matsuda Y, Yamashita K et al (2018) The effect on surgical skills of expert surgeons using 3D\/HD and 2D\/4K resolution monitors in laparoscopic phantom tasks. Surg Endosc 32:4228\u20134234. https:\/\/doi.org\/10.1007\/s00464-018-6169-1","journal-title":"Surg Endosc"},{"key":"3951_CR27","doi-asserted-by":"publisher","first-page":"S419","DOI":"10.1007\/s00464-006-0020-9","volume":"20","author":"A Cuschieri","year":"2006","unstructured":"Cuschieri A (2006) Epistemology of visual imaging in endoscopic surgery. Surg Endosc 20:S419\u2013S424. https:\/\/doi.org\/10.1007\/s00464-006-0020-9","journal-title":"Surg Endosc"},{"key":"3951_CR28","doi-asserted-by":"publisher","first-page":"5259","DOI":"10.1007\/s00464-026-12791-9","volume":"40","author":"F Badaloni","year":"2026","unstructured":"Badaloni F, Kuiper G, De Jong R, Van Jaarsveld R, Li Y, Van Der Neut M et al (2026) Are we developing the right intraoperative AI assistance? Surgeons\u2019 perspectives and desired functions. Surg Endosc 40:5259\u20135266. https:\/\/doi.org\/10.1007\/s00464-026-12791-9","journal-title":"Surg Endosc"},{"key":"3951_CR29","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1007\/s11701-025-02333-1","volume":"19","author":"ZY Motiwala","year":"2025","unstructured":"Motiwala ZY, Desai A, Bisht R, Lathkar S, Misra S, Carbin DD (2025) Telesurgery: current status and strategies for latency reduction. J Robot Surg 19:153. https:\/\/doi.org\/10.1007\/s11701-025-02333-1","journal-title":"J Robot Surg"}],"container-title":["Journal of Robotic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11701-026-03951-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11701-026-03951-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11701-026-03951-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,19]],"date-time":"2026-09-19T08:38:12Z","timestamp":1789807092000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11701-026-03951-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,19]]},"references-count":29,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["3951"],"URL":"https:\/\/doi.org\/10.1007\/s11701-026-03951-z","relation":{},"ISSN":["1863-2491"],"issn-type":[{"value":"1863-2491","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,19]]},"assertion":[{"value":"21 July 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 September 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 September 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was conducted in accordance with the Declaration of Helsinki. The survey was approved by the Ethics Committee of the Medical School at Christian-Albrechts University Kiel under approval code D-525\/26. The same committee approved the collection and storage of intraoperative video recordings obtained during routine patient care for research in minimally invasive urology at University Hospital Schleswig-Holstein Campus Kiel under approval code D-649\/25. The evaluation material included in the present study was collected under this approval. Prior to evaluation and publication, L. Buck reviewed all frames and video clips for potentially identifying information, including patient identifiers displayed in image overlays, faces, tattoos, and other distinguishing features. None of the presented material contains identifying information.","order":2,"name":"Ethics","label":"Ethical approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All clinicians who participated in the survey provided informed consent. Participation was voluntary, and responses were collected anonymously. Written broad consent was obtained from all patients whose intraoperative video recordings were included. This consent allowed their medical data, including routinely acquired intraoperative recordings, to be used for research purposes.","order":3,"name":"Ethics","label":"Informed Consent","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"1007"}}