{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T19:22:54Z","timestamp":1792783374489,"version":"4.5.0"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T00:00:00Z","timestamp":1790035200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T00:00:00Z","timestamp":1790035200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"The Observatory for Human-Machine Collaboration, University of Cambridge","id":[{"id":"https:\/\/ror.org\/013meh722","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Robotic Surg"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Virtual model control (VMC) provides compliant trajectory execution, but sustained contact loads can produce residual positional error. This study evaluated the sequential development of VMC augmented with integral control for powered dry-bone resection and assessed the effects of end-effector stabilisation, spatial calibration and operating parameters. A seven-degree-of-freedom Franka Research 3 robot was commanded using VMC with integral control and carried a 4-mm diamond-tipped arthroscopic burr through a programmed 10\u2009\u00d7\u200910 mm serpentine trajectory in 20 pounds-per-cubic-foot synthetic bone. Four sequential configurations were assessed: an original handle-based mount, an anthropomorphically designed shaft-stabilising mount, robot-frame calibration and workpiece registration. Each configuration comprised three resections. Performance was graded by one non-blinded assessor using a study-specific twelve-point score across burr-tip oscillation and X-, Y- and Z-axis deviation, with lower scores indicating better performance. Radial depth of cut, engagement depth, trajectory velocity and burr angle were then screened to identify candidate operating parameters. Mean total score decreased sequentially from 11.7\/12 with the original mount to 7.7\/12 after shaft stabilisation, 5.7\/12 after robot-frame calibration and 4.0\/12 after workpiece registration. The lowest observed score was maintained at an RDOC between 0.10 and 0.25 mm, a measured depth between 1.52 and 1.89 mm, velocity between 1.5 and 2.5 mm\/s and a burr angle between 30 and 45 degrees. Mechanical stabilisation and spatial calibration were associated with progressively better resection performance using VMC with integral control. This exploratory benchtop study identified candidate operating ranges for further assessment in higher-fidelity models.<\/jats:p>","DOI":"10.1007\/s11701-026-03963-9","type":"journal-article","created":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T05:09:45Z","timestamp":1790053785000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Sequential evaluation of a robotic dry-bone resection system using virtual model control with integral control: an exploratory benchtop study"],"prefix":"10.1007","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0009-0004-6025-1247","authenticated-orcid":false,"given":"Ryan","family":"McWilliams","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Larby","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5728-0176","authenticated-orcid":false,"given":"Fulvio","family":"Forni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9454-3978","authenticated-orcid":false,"given":"Vikas","family":"Khanduja","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,22]]},"reference":[{"key":"3963_CR1","doi-asserted-by":"publisher","first-page":"1427","DOI":"10.1007\/s00264-011-1278-7","volume":"35","author":"S Imam","year":"2011","unstructured":"Imam S, Khanduja V (2011) Current concepts in the diagnosis and management of femoroacetabular impingement. Int Orthop 35:1427\u20131435. https:\/\/doi.org\/10.1007\/s00264-011-1278-7","journal-title":"Int Orthop"},{"key":"3963_CR2","doi-asserted-by":"publisher","first-page":"1169","DOI":"10.1136\/bjsports-2016-096743","volume":"50","author":"DR Griffin","year":"2016","unstructured":"Griffin DR, Dickenson EJ, O\u2019Donnell J et al (2016) The Warwick Agreement on femoroacetabular impingement syndrome: an international consensus statement. Br J Sports Med 50:1169\u20131176. https:\/\/doi.org\/10.1136\/bjsports-2016-096743","journal-title":"Br J Sports Med"},{"key":"3963_CR3","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1097\/01.blo.0000096804.78689.c2","volume":"417","author":"R Ganz","year":"2003","unstructured":"Ganz R, Parvizi J, Beck M, Leunig M, N\u00f6tzli H, Siebenrock KA (2003) Femoroacetabular impingement: a cause for osteoarthritis of the hip. Clin Orthop Relat Res 417:112\u2013120. https:\/\/doi.org\/10.1097\/01.blo.0000096804.78689.c2","journal-title":"Clin Orthop Relat Res"},{"key":"3963_CR4","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1016\/j.arthro.2021.05.066","volume":"38","author":"W Yarwood","year":"2022","unstructured":"Yarwood W, Sunil Kumar KH, Ng KCG, Khanduja V (2022) Biomechanics of cam femoroacetabular impingement: a systematic review. Arthroscopy 38:174\u2013189. https:\/\/doi.org\/10.1016\/j.arthro.2021.05.066","journal-title":"Arthroscopy"},{"key":"3963_CR5","doi-asserted-by":"publisher","first-page":"918","DOI":"10.1136\/annrheumdis-2012-201643","volume":"72","author":"R Agricola","year":"2013","unstructured":"Agricola R, Heijboer MP, Bierma-Zeinstra SMA, Verhaar JAN, Weinans H, Waarsing JH (2013) Cam impingement causes osteoarthritis of the hip: a nationwide prospective cohort study (CHECK). Ann Rheum Dis 72:918\u2013923. https:\/\/doi.org\/10.1136\/annrheumdis-2012-201643","journal-title":"Ann Rheum Dis"},{"key":"3963_CR6","doi-asserted-by":"publisher","first-page":"1035","DOI":"10.1007\/s00167-007-0319-7","volume":"15","author":"V Khanduja","year":"2007","unstructured":"Khanduja V, Villar RN (2007) The arthroscopic management of femoroacetabular impingement. Knee Surg Sports Traumatol Arthrosc 15:1035\u20131040. https:\/\/doi.org\/10.1007\/s00167-007-0319-7","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"3963_CR7","doi-asserted-by":"publisher","first-page":"437","DOI":"10.4055\/cios21109","volume":"13","author":"V Khanduja","year":"2021","unstructured":"Khanduja V, Ha YC, Koo KH (2021) Controversial issues in arthroscopic surgery for femoroacetabular impingement. Clin Orthop Surg 13:437\u2013442. https:\/\/doi.org\/10.4055\/cios21109","journal-title":"Clin Orthop Surg"},{"key":"3963_CR8","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1177\/0363546520974378","volume":"49","author":"J Van Houcke","year":"2021","unstructured":"Van Houcke J, Khanduja V, Audenaert EA (2021) Accurate arthroscopic cam resection normalizes contact stresses in patients with femoroacetabular impingement. Am J Sports Med 49:42\u201348. https:\/\/doi.org\/10.1177\/0363546520974378","journal-title":"Am J Sports Med"},{"key":"3963_CR9","doi-asserted-by":"publisher","first-page":"2225","DOI":"10.1016\/S0140-6736(18)31202-9","volume":"391","author":"DR Griffin","year":"2018","unstructured":"Griffin DR, Dickenson EJ, Wall PDH et al (2018) Hip arthroscopy versus best conservative care for the treatment of femoroacetabular impingement syndrome (UK FASHIoN): a multicentre randomised controlled trial. Lancet 391:2225\u20132235. https:\/\/doi.org\/10.1016\/S0140-6736(18)31202-9","journal-title":"Lancet"},{"key":"3963_CR10","doi-asserted-by":"publisher","first-page":"l185","DOI":"10.1136\/bmj.l185","volume":"364","author":"AJR Palmer","year":"2019","unstructured":"Palmer AJR, Ayyar Gupta V, Fernquest S et al (2019) Arthroscopic hip surgery compared with physiotherapy and activity modification for the treatment of symptomatic femoroacetabular impingement: multicentre randomised controlled trial. BMJ 364:l185. https:\/\/doi.org\/10.1136\/bmj.l185","journal-title":"BMJ"},{"key":"3963_CR11","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1007\/s00167-022-07042-y","volume":"31","author":"R Holleyman","year":"2023","unstructured":"Holleyman R, Sohatee MA, Lyman S, Malviya A, Khanduja V, NAHR User Group (2023) Hip arthroscopy for femoroacetabular impingement is associated with significant improvement in early patient reported outcomes: analysis of 4963 cases from the UK non-arthroplasty registry (NAHR) dataset. Knee Surg Sports Traumatol Arthrosc 31:58\u201369. https:\/\/doi.org\/10.1007\/s00167-022-07042-y","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"3963_CR12","doi-asserted-by":"publisher","first-page":"e1929","DOI":"10.1002\/rcs.1929","volume":"14","author":"N Nakano","year":"2018","unstructured":"Nakano N, Audenaert E, Ranawat A, Khanduja V (2018) Review: current concepts in computer-assisted hip arthroscopy. Int J Med Robot 14:e1929. https:\/\/doi.org\/10.1002\/rcs.1929","journal-title":"Int J Med Robot"},{"key":"3963_CR13","doi-asserted-by":"publisher","first-page":"389","DOI":"10.1016\/j.arthro.2013.11.012","volume":"30","author":"DJ Hoppe","year":"2014","unstructured":"Hoppe DJ, de Sa D, Simunovic N, Bhandari M, Safran MR, Larson CM, Ayeni OR (2014) The learning curve for hip arthroscopy: a systematic review. Arthroscopy 30:389\u2013397. https:\/\/doi.org\/10.1016\/j.arthro.2013.11.012","journal-title":"Arthroscopy"},{"key":"3963_CR14","doi-asserted-by":"publisher","first-page":"3092","DOI":"10.1016\/j.arthro.2020.06.033","volume":"36","author":"CC Go","year":"2020","unstructured":"Go CC, Kyin C, Maldonado DR, Domb BG (2020) Surgeon experience in hip arthroscopy affects surgical time, complication rate, and reoperation rate: a systematic review on the learning curve. Arthroscopy 36:3092\u20133105. https:\/\/doi.org\/10.1016\/j.arthro.2020.06.033","journal-title":"Arthroscopy"},{"key":"3963_CR15","doi-asserted-by":"publisher","first-page":"1388","DOI":"10.1007\/s11999-014-4069-9","volume":"473","author":"JR Ross","year":"2015","unstructured":"Ross JR, Larson CM, Adeoye O, Kelly BT, Bedi A (2015) Residual deformity is the most common reason for revision hip arthroscopy: a three-dimensional CT study. Clin Orthop Relat Res 473:1388\u20131395. https:\/\/doi.org\/10.1007\/s11999-014-4069-9","journal-title":"Clin Orthop Relat Res"},{"key":"3963_CR16","doi-asserted-by":"publisher","first-page":"1382","DOI":"10.1016\/j.arthro.2014.12.027","volume":"31","author":"GL Cvetanovich","year":"2015","unstructured":"Cvetanovich GL, Harris JD, Erickson BJ, Bach BR, Bush-Joseph CA, Nho SJ (2015) Revision hip arthroscopy: a systematic review of diagnoses, operative findings, and outcomes. Arthroscopy 31:1382\u20131390. https:\/\/doi.org\/10.1016\/j.arthro.2014.12.027","journal-title":"Arthroscopy"},{"key":"3963_CR17","doi-asserted-by":"publisher","first-page":"662720","DOI":"10.3389\/fsurg.2021.662720","volume":"8","author":"KN Kunze","year":"2021","unstructured":"Kunze KN, Olsen RJ, Sullivan SW, Nwachukwu BU (2021) Revision hip arthroscopy in the native hip: a review of contemporary evaluation and treatment options. Front Surg 8:662720. https:\/\/doi.org\/10.3389\/fsurg.2021.662720","journal-title":"Front Surg"},{"key":"3963_CR18","doi-asserted-by":"publisher","first-page":"273","DOI":"10.2106\/JBJS.D.01793","volume":"87","author":"RM Mardones","year":"2005","unstructured":"Mardones RM, Gonzalez C, Chen Q, Zobitz M, Kaufman KR, Trousdale RT (2005) Surgical treatment of femoroacetabular impingement: evaluation of the effect of the size of the resection. J Bone Joint Surg Am 87:273\u2013279. https:\/\/doi.org\/10.2106\/JBJS.D.01793","journal-title":"J Bone Joint Surg Am"},{"key":"3963_CR19","doi-asserted-by":"publisher","first-page":"1608","DOI":"10.1016\/j.arthro.2013.06.021","volume":"29","author":"CA Wijdicks","year":"2013","unstructured":"Wijdicks CA, Balldin BC, Jansson KS, Stull JD, LaPrade RF, Philippon MJ (2013) Cam lesion femoral osteoplasty: in vitro biomechanical evaluation of iatrogenic femoral cortical notching and risk of neck fracture. Arthroscopy 29:1608\u20131614. https:\/\/doi.org\/10.1016\/j.arthro.2013.06.021","journal-title":"Arthroscopy"},{"key":"3963_CR20","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1093\/jhps\/hnw048","volume":"4","author":"NS Horner","year":"2017","unstructured":"Horner NS, Khanduja V, MacDonald AE, Naendrup JH, Simunovic N, Ayeni OR (2017) Femoral neck fractures as a complication of hip arthroscopy: a systematic review. J Hip Preserv Surg 4:9\u201317. https:\/\/doi.org\/10.1093\/jhps\/hnw048","journal-title":"J Hip Preserv Surg"},{"key":"3963_CR21","doi-asserted-by":"publisher","first-page":"2061","DOI":"10.1177\/0363546518779064","volume":"46","author":"Y Mansor","year":"2018","unstructured":"Mansor Y, Perets I, Close MR, Mu BH, Domb BG (2018) In search of the spherical femoroplasty: cam overresection leads to inferior functional scores before and after revision hip arthroscopic surgery. Am J Sports Med 46:2061\u20132071. https:\/\/doi.org\/10.1177\/0363546518779064","journal-title":"Am J Sports Med"},{"key":"3963_CR22","doi-asserted-by":"publisher","first-page":"765","DOI":"10.1109\/TRA.2003.817058","volume":"19","author":"RH Taylor","year":"2003","unstructured":"Taylor RH, Stoianovici D (2003) Medical robotics in computer-integrated surgery. IEEE Trans Robot Autom 19:765\u2013781. https:\/\/doi.org\/10.1109\/TRA.2003.817058","journal-title":"IEEE Trans Robot Autom"},{"key":"3963_CR23","doi-asserted-by":"publisher","first-page":"e1839","DOI":"10.1002\/rcs.1839","volume":"13","author":"J Van Houcke","year":"2017","unstructured":"Van Houcke J, Khanduja V, Nakano N, Krekel P, Pattyn C, Audenaert E (2017) Accuracy of navigated cam resection in femoroacetabular impingement: a randomised controlled trial. Int J Med Robot 13:e1839. https:\/\/doi.org\/10.1002\/rcs.1839","journal-title":"Int J Med Robot"},{"key":"3963_CR24","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1002\/rcs.1486","volume":"9","author":"M Masjedi","year":"2013","unstructured":"Masjedi M, Tan WL, Jaskaranjit S, Aqil A, Harris S, Cobb J (2013) Use of robotic technology in cam femoroacetabular impingement corrective surgery. Int J Med Robot 9:23\u201328. https:\/\/doi.org\/10.1002\/rcs.1486","journal-title":"Int J Med Robot"},{"key":"3963_CR25","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1093\/jhps\/hnv007","volume":"2","author":"CN Park","year":"2015","unstructured":"Park CN, Nawabi DH, Christopher J, Conditt MA, Ranawat AS (2015) Robotic-assisted femoral osteochondroplasty is more precise than a freehand technique in a Sawbone model. J Hip Preserv Surg 2:136\u2013144. https:\/\/doi.org\/10.1093\/jhps\/hnv007","journal-title":"J Hip Preserv Surg"},{"key":"3963_CR26","doi-asserted-by":"publisher","unstructured":"Almoussa S, Barton C, Speirs AD, Gofton W, Beaul\u00e9 PE (2011) Computer-assisted correction of cam-type femoroacetabular impingement: a Sawbones study. J Bone Joint Surg Am 93 Suppl 270\u201375. https:\/\/doi.org\/10.2106\/JBJS.J.01706","DOI":"10.2106\/JBJS.J.01706"},{"key":"3963_CR27","doi-asserted-by":"publisher","first-page":"1272","DOI":"10.1177\/03635465221074338","volume":"50","author":"K Abe","year":"2022","unstructured":"Abe K, Oba M, Kobayashi N, Higashihira S, Choe H, Tezuka T, Ike H, Inaba Y (2022) Accuracy of computer navigation-assisted arthroscopic osteochondroplasty for cam-type femoroacetabular impingement using the model-to-image registration method. Am J Sports Med 50:1272\u20131280. https:\/\/doi.org\/10.1177\/03635465221074338","journal-title":"Am J Sports Med"},{"key":"3963_CR28","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1115\/1.3140702","volume":"107","author":"N Hogan","year":"1985","unstructured":"Hogan N (1985) Impedance control: an approach to manipulation: Part I\u2014Theory. J Dyn Syst Meas Control 107:1\u20137. https:\/\/doi.org\/10.1115\/1.3140702","journal-title":"J Dyn Syst Meas Control"},{"key":"3963_CR29","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1177\/02783640122067309","volume":"20","author":"J Pratt","year":"2001","unstructured":"Pratt J, Chew CM, Torres A, Dilworth P, Pratt G (2001) Virtual model control: an intuitive approach for bipedal locomotion. Int J Robot Res 20:129\u2013143. https:\/\/doi.org\/10.1177\/02783640122067309","journal-title":"Int J Robot Res"},{"key":"3963_CR30","doi-asserted-by":"publisher","first-page":"8548","DOI":"10.1016\/j.ifacol.2023.10.015","volume":"56","author":"D Larby","year":"2023","unstructured":"Larby D, Forni F (2023) A generalized approach to impedance control design for robotic minimally invasive surgery. IFAC-PapersOnLine 56:8548\u20138555. https:\/\/doi.org\/10.1016\/j.ifacol.2023.10.015","journal-title":"IFAC-PapersOnLine"},{"key":"3963_CR31","doi-asserted-by":"publisher","first-page":"439","DOI":"10.1109\/TRO.2025.3645886","volume":"42","author":"D Larby","year":"2026","unstructured":"Larby D, Forni F (2026) Optimal virtual model control for robotics: design and tuning of passivity-based controllers. IEEE Trans Robot 42:439\u2013454. https:\/\/doi.org\/10.1109\/TRO.2025.3645886","journal-title":"IEEE Trans Robot"},{"key":"3963_CR32","doi-asserted-by":"publisher","first-page":"624","DOI":"10.1302\/0301-620X.94B5.28627","volume":"94","author":"EA Audenaert","year":"2012","unstructured":"Audenaert EA, Smet B, Pattyn C, Khanduja V (2012) Imageless versus image-based registration in navigated arthroscopy of the hip: a cadaver-based assessment. J Bone Joint Surg Br 94:624\u2013629. https:\/\/doi.org\/10.1302\/0301-620X.94B5.28627","journal-title":"J Bone Joint Surg Br"}],"container-title":["Journal of Robotic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11701-026-03963-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11701-026-03963-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11701-026-03963-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T18:03:29Z","timestamp":1790100209000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11701-026-03963-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,22]]},"references-count":32,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["3963"],"URL":"https:\/\/doi.org\/10.1007\/s11701-026-03963-9","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-10856382\/v1","asserted-by":"object"}]},"ISSN":["1863-2491"],"issn-type":[{"value":"1863-2491","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,22]]},"assertion":[{"value":"28 August 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 September 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 September 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable. This bench study involved no human participants, human data, animals or biological material.","order":2,"name":"Ethics","label":"Ethics approval","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"1012"}}