{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,19]],"date-time":"2025-03-19T10:09:31Z","timestamp":1742378971679},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2011,9,23]],"date-time":"2011-09-23T00:00:00Z","timestamp":1316736000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Intern Emerg Med"],"published-print":{"date-parts":[[2012,2]]},"DOI":"10.1007\/s11739-011-0691-7","type":"journal-article","created":{"date-parts":[[2011,9,22]],"date-time":"2011-09-22T18:34:50Z","timestamp":1316716490000},"page":"59-63","source":"Crossref","is-referenced-by-count":7,"title":["Endotrol-tracheal tube assisted endotracheal intubation during video laryngoscopy"],"prefix":"10.1007","volume":"7","author":[{"given":"Davide","family":"Cattano","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carlos","family":"Artime","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vineela","family":"Maddukuri","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"William H.","family":"Daily","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alfonso","family":"Altamirano","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Katherine C.","family":"Normand","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"suffix":"IV","given":"Clarence E.","family":"Gilmore","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carin A.","family":"Hagberg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2011,9,23]]},"reference":[{"key":"691_CR1","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1111\/j.1365-2044.2004.04013.x","volume":"60","author":"MR Rai","year":"2005","unstructured":"Rai MR, Dering A, Verghese C (2005) The glidescope system: a clinical assessment of performance. Anaesthesia 60:60\u201364","journal-title":"Anaesthesia"},{"key":"691_CR2","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1007\/BF03022777","volume":"54","author":"B Shippey","year":"2007","unstructured":"Shippey B, Ray D, McKeown D (2007) Case series: the McGrath videolaryngoscope\u2013an initial clinical evaluation. Can J Anaesth 54:307\u2013313","journal-title":"Can J Anaesth"},{"key":"691_CR3","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1016\/j.jclinane.2006.01.002","volume":"18","author":"MB Kaplan","year":"2006","unstructured":"Kaplan MB, Hagberg CA, Ward DS, Brambrink A, Chhibber AK, Heidegger T, Lozada L, Ovassapian A, Parsons D, Ramsay J, Wilhelm W, Zwissler B, Gerig HJ, Hofstetter C, Karan S, Kreisler N, Pousman RM, Thierbach A, Wrobel M, Berci G (2006) Comparison of direct and video-assisted views of the larynx during routine intubation. J Clin Anesth 18:357\u2013362","journal-title":"J Clin Anesth"},{"key":"691_CR4","doi-asserted-by":"publisher","first-page":"1050","DOI":"10.1111\/j.1399-6576.2010.02285.x","volume":"54","author":"P Niforopoulou","year":"2010","unstructured":"Niforopoulou P, Pantazopoulos I, Demestiha T, Koudouna E, Xanthos T (2010) Video-laryngoscopes in the adult airway management: a topical review of the literature. Acta Anaesthesiol Scand 54:1050\u20131061","journal-title":"Acta Anaesthesiol Scand"},{"key":"691_CR5","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1213\/ane.0b013e3181ae39db","volume":"109","author":"A Zundert van","year":"2009","unstructured":"van Zundert A, Maassen R, Lee R, Willems R, Timmerman M, Siemonsma M, Buise M, Wiepking M (2009) A Macintosh laryngoscope blade for videolaryngoscopy reduces stylet use in patients with normal airways. Anesth Analg 109:825\u2013831","journal-title":"Anesth Analg"},{"key":"691_CR6","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1007\/BF03015790","volume":"52","author":"JV Cuchillo","year":"2005","unstructured":"Cuchillo JV, Rodriguez MA (2005) Considerations aimed at facilitating the use of the new GlideScope videolaryngoscope. Can J Anaesth 52:661","journal-title":"Can J Anaesth"},{"key":"691_CR7","doi-asserted-by":"publisher","first-page":"1610","DOI":"10.1213\/01.ane.0000264321.04403.06","volume":"104","author":"AM Malik","year":"2007","unstructured":"Malik AM, Frogel JK (2007) Anterior tonsillar pillar perforation during GlideScope\u00ae video laryngoscopy. Anesth Analg 104:1610\u20131611","journal-title":"Anesth Analg"},{"issue":"8","key":"691_CR8","doi-asserted-by":"publisher","first-page":"619","DOI":"10.1016\/j.jclinane.2007.03.010","volume":"19","author":"RD Vincent Jr","year":"2007","unstructured":"Vincent RD Jr, Wimberly MP, Brockwell RC, Magnuson JS (2007) Soft palate perforation during orotracheal intubation facilitated by the GlideScope video laryngoscope. J Clin Anesth 19(8):619\u2013621","journal-title":"J Clin Anesth"},{"key":"691_CR9","doi-asserted-by":"publisher","first-page":"588","DOI":"10.1007\/BF03022329","volume":"54","author":"P Cross","year":"2007","unstructured":"Cross P, Cytryn J, Cheng KK (2007) Perforation of the soft palate using the GlideScope videolaryngoscope. Can J Anesth 54:588\u2013589","journal-title":"Can J Anesth"},{"key":"691_CR10","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1016\/j.otohns.2007.02.038","volume":"137","author":"Y Hirabayashi","year":"2007","unstructured":"Hirabayashi Y (2007) Pharyngeal injury related to GlideScope video laryngoscope. Otolaryngol Head Neck Surg 137:175\u2013176","journal-title":"Otolaryngol Head Neck Surg"},{"key":"691_CR11","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1007\/BF03021900","volume":"54","author":"RM Cooper","year":"2007","unstructured":"Cooper RM (2007) Complications associated with the use of the GlideScope videolaryngoscope. Can J Anesth 54:54\u201357","journal-title":"Can J Anesth"},{"key":"691_CR12","doi-asserted-by":"publisher","first-page":"1609","DOI":"10.1213\/01.ane.0000265490.26332.48","volume":"104","author":"WT Hsu","year":"2007","unstructured":"Hsu WT, Hsu SC, Lee YL, Huang JS, Chen CL (2007) Penetrating injury of the soft palate during GlideScope intubation. Anesth Analg 104:1609\u20131610","journal-title":"Anesth Analg"},{"key":"691_CR13","doi-asserted-by":"publisher","first-page":"661","DOI":"10.1097\/EJA.0b013e32832a0be3","volume":"26","author":"M Yamakage","year":"2009","unstructured":"Yamakage M, Takahashi M, Tachibana N, Takahashi K, Namiki A (2009) Usefulness of Endoflex endotracheal tube for oral and nasal tracheal intubations. Eur J Anaesthesiol 26:661\u2013665","journal-title":"Eur J Anaesthesiol"},{"key":"691_CR14","doi-asserted-by":"publisher","first-page":"1172","DOI":"10.1111\/j.1365-2044.2009.06058.x","volume":"64","author":"WL Teoh","year":"2009","unstructured":"Teoh WL, Sia ATH, Fun WLL (2009) A prospective, randomised, cross-over trial comparing the EndoFlex and standard tracheal tubes in patients with predicted easy intubation. Anaesthesia 64:1172\u20131177","journal-title":"Anaesthesia"},{"key":"691_CR15","doi-asserted-by":"publisher","first-page":"473","DOI":"10.1007\/BF03016316","volume":"55","author":"D Phua","year":"2008","unstructured":"Phua D, Wang CF, Yoong CS (2008) Use of the Endoflex endotracheal tube as a stylet-free alternative in GlideScope intubations. Can J Anesth 55:473\u2013474","journal-title":"Can J Anesth"},{"key":"691_CR16","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1213\/00000539-199407000-00025","volume":"79","author":"T Shigematsu","year":"1994","unstructured":"Shigematsu T, Miyazawa N, Kobayashi M, Yorozu T, Toyoda Y, Morisaki H (1994) Nasal intubation with Bullard laryngoscope: a useful approach for difficult airways. Anesth Analg 79:132\u2013135","journal-title":"Anesth Analg"},{"key":"691_CR17","doi-asserted-by":"publisher","first-page":"960","DOI":"10.1111\/j.1399-6576.2009.02017.x","volume":"53","author":"K Sugiyama","year":"2009","unstructured":"Sugiyama K, Takahashi N, Kohjitani A (2009) Combining the EndoFlex tube with fiberoptic bronchoscopy in difficult intubation. Acta Anaesthesiol Scand 53:960\u2013963","journal-title":"Acta Anaesthesiol Scand"}],"container-title":["Internal and Emergency Medicine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11739-011-0691-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11739-011-0691-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11739-011-0691-7","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11739-011-0691-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,2,18]],"date-time":"2020-02-18T04:23:03Z","timestamp":1581999783000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11739-011-0691-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,9,23]]},"references-count":17,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2012,2]]}},"alternative-id":["691"],"URL":"https:\/\/doi.org\/10.1007\/s11739-011-0691-7","relation":{},"ISSN":["1828-0447","1970-9366"],"issn-type":[{"value":"1828-0447","type":"print"},{"value":"1970-9366","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,9,23]]}}}