{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,17]],"date-time":"2026-06-17T01:09:47Z","timestamp":1781658587730,"version":"3.54.5"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2013,9,4]],"date-time":"2013-09-04T00:00:00Z","timestamp":1378252800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Intern Emerg Med"],"published-print":{"date-parts":[[2014,2]]},"DOI":"10.1007\/s11739-013-0995-x","type":"journal-article","created":{"date-parts":[[2013,9,3]],"date-time":"2013-09-03T08:48:37Z","timestamp":1378198117000},"page":"93-98","source":"Crossref","is-referenced-by-count":93,"title":["Comparison of video laryngoscopy to direct laryngoscopy for intubation of patients with difficult airway characteristics in the emergency department"],"prefix":"10.1007","volume":"9","author":[{"given":"John Constantine","family":"Sakles","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Asad E.","family":"Patanwala","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jarrod M.","family":"Mosier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John Michael","family":"Dicken","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2013,9,4]]},"reference":[{"issue":"2","key":"995_CR1","doi-asserted-by":"crossref","first-page":"607","DOI":"10.1213\/01.ANE.0000122825.04923.15","volume":"99","author":"TC Mort","year":"2004","unstructured":"Mort TC (2004) Emergency tracheal intubation: complications associated with repeated laryngoscopic attempts. Anesth Analg 99(2):607\u2013613","journal-title":"Anesth Analg"},{"issue":"1","key":"995_CR2","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1111\/acem.12055","volume":"20","author":"JC Sakles","year":"2013","unstructured":"Sakles JC, Chiu S, Mosier J, Walker C, Stolz U (2013) The importance of first pass success when performing orotracheal intubation in the emergency department. Acad Emerg Med 20(1):71\u201378","journal-title":"Acad Emerg Med"},{"key":"995_CR3","doi-asserted-by":"crossref","unstructured":"Hasegawa K, Shigemitsu K, Hagiwara Y, Chiba T, Watase H, Brown CA 3rd, Brown DF(2012) Japanese Emergency Medicine Research Alliance Investigators.Association between repeated intubation attempts and adverse events in emergency departments: an analysis of a multicenter prospective observational study. Ann Emerg Med 60(6):749\u2013754","DOI":"10.1016\/j.annemergmed.2012.04.005"},{"issue":"1","key":"995_CR4","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/S0736-4679(01)00435-8","volume":"22","author":"SL Orebaugh","year":"2002","unstructured":"Orebaugh SL (2002) Difficult airway management in the emergency department. J Emerg Med 22(1):31\u201348","journal-title":"J Emerg Med"},{"issue":"2","key":"995_CR5","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1007\/s12245-008-0030-6","volume":"1","author":"E Wong","year":"2008","unstructured":"Wong E, Ng YY (2008) The difficult airway in the emergency department. Int J Emerg Med 1(2):107\u2013111","journal-title":"Int J Emerg Med"},{"issue":"8","key":"995_CR6","doi-asserted-by":"crossref","first-page":"905","DOI":"10.1016\/j.ajem.2008.07.003","volume":"27","author":"S Soyuncu","year":"2009","unstructured":"Soyuncu S, Eken C, Cete Y, Bektas F, Akcimen M (2009) Determination of difficult intubation in the ED. Am J Emerg Med 27(8):905\u2013910","journal-title":"Am J Emerg Med"},{"issue":"3","key":"995_CR7","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1016\/S0196-0644(98)70342-7","volume":"31","author":"JC Sakles","year":"1998","unstructured":"Sakles JC, Laurin EG, Rantapaa AA, Panacek EA (1998) Airway management in the emergency department: a one-year study of 610 tracheal intubations. Ann Emerg Med 31(3):325\u2013332","journal-title":"Ann Emerg Med"},{"key":"995_CR8","doi-asserted-by":"crossref","unstructured":"Walls RM, Brown CA 3rd, Bair AE, Pallin DJ (2011) NEAR II Investigators. Emergency airway management: a multi-center report of 8937 emergency department intubations. J Emerg Med 41(4):347\u201354","DOI":"10.1016\/j.jemermed.2010.02.024"},{"issue":"9","key":"995_CR9","doi-asserted-by":"crossref","first-page":"1050","DOI":"10.1111\/j.1399-6576.2010.02285.x","volume":"54","author":"P Niforopoulou","year":"2010","unstructured":"Niforopoulou P, Pantazopoulos I, Demestiha T, Koudouna E, Xanthos T (2010) Video-laryngoscopes in the adult airway management: a topical review of the literature. Acta Anaesthesiol Scand 54(9):1050\u20131061","journal-title":"Acta Anaesthesiol Scand"},{"key":"995_CR10","doi-asserted-by":"crossref","unstructured":"Healy DW, Maties O, Hovord D, Kheterpal S (2012) A systematic review of the role of videolaryngoscopy in successful orotracheal intubation. BMC Anesthesiol 12:32","DOI":"10.1186\/1471-2253-12-32"},{"key":"995_CR11","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1016\/j.tcmj.2012.07.002","volume":"24","author":"JC Chen","year":"2012","unstructured":"Chen JC, Shyr MH (2012) Role of video laryngoscopy in the management of difficult intubations in the emergency department and during prehospital care. Tzu Chi Med J 24:100\u2013103","journal-title":"Tzu Chi Med J"},{"issue":"9","key":"995_CR12","doi-asserted-by":"crossref","first-page":"866","DOI":"10.1111\/j.1553-2712.2009.00492.x","volume":"16","author":"TF Platts-Mills","year":"2009","unstructured":"Platts-Mills TF, Campagne D, Chinnock B, Snowden B, Glickman LT, Hendey GW (2009) A comparison of Glide Scope video laryngoscopy versus direct laryngoscopy intubation in the emergency department. Acad Emerg Med 16(9):866\u2013871","journal-title":"Acad Emerg Med"},{"issue":"6","key":"995_CR13","doi-asserted-by":"crossref","first-page":"739","DOI":"10.1016\/j.annemergmed.2012.03.031","volume":"60","author":"JC Sakles","year":"2012","unstructured":"Sakles JC, Mosier J, Chiu S, Cosentino M, Kalin L (2012) A comparison of the C-MAC video laryngoscope to the Macintosh direct laryngoscope for intubation in the emergency department. Ann Emerg Med 60(6):739\u2013748","journal-title":"Ann Emerg Med"},{"issue":"4","key":"995_CR14","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1016\/j.jemermed.2011.05.019","volume":"42","author":"JC Sakles","year":"2012","unstructured":"Sakles JC, Mosier JM, Chiu S, Keim SM (2012) Tracheal intubation in the emergency department: a comparison of Glide Scope\u00ae video laryngoscopy to direct laryngoscopy in 822 intubations. J Emerg Med 42(4):400\u2013405","journal-title":"J Emerg Med"},{"key":"995_CR15","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/j.jacme.2012.04.003","volume":"2","author":"YK Lee","year":"2012","unstructured":"Lee YK, Chen CC, Wang TL, Lin KJ, Su YC (2012) Comparison of video and direct laryngoscope for tracheal intubation in emergency settings: a meta-analysis. J Acute Med 2:43\u201349","journal-title":"J Acute Med"},{"issue":"5","key":"995_CR16","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1016\/j.jemermed.2008.12.019","volume":"38","author":"AE Bair","year":"2010","unstructured":"Bair AE, Caravelli R, Tyler K, Laurin EG (2010) Feasibility of the preoperative Mallampati airway assessment in emergency department patients. J Emerg Med 38(5):677\u2013680","journal-title":"J Emerg Med"},{"issue":"4","key":"995_CR17","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/j.annemergmed.2004.05.006","volume":"44","author":"RM Levitan","year":"2004","unstructured":"Levitan RM, Everett WW, Ochroch EA (2004) Limitations of difficult airway prediction in patients intubated in the emergency department. Ann Emerg Med 44(4):307\u2013313","journal-title":"Ann Emerg Med"},{"issue":"6","key":"995_CR18","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1016\/j.jemermed.2011.06.007","volume":"42","author":"JM Mosier","year":"2012","unstructured":"Mosier JM, Stolz U, Chiu S, Sakles JC (2012) Difficult airway management in the emergency department: Glide Scope videolaryngoscopy compared to direct laryngoscopy. J Emerg Med 42(6):629\u2013634","journal-title":"J Emerg Med"},{"issue":"3","key":"995_CR19","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1097\/ALN.0b013e318246ea34","volume":"116","author":"MF Aziz","year":"2012","unstructured":"Aziz MF, Dillman D, Fu R, Brambrink AM (2012) Comparative effectiveness of the C-MAC video laryngoscope versus direct laryngoscopy in the setting of the predicted difficult airway. Anesthesiology 116(3):629\u2013636","journal-title":"Anesthesiology"},{"issue":"1","key":"995_CR20","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1097\/EJA.0b013e32832d328d","volume":"27","author":"G Serocki","year":"2010","unstructured":"Serocki G, Bein B, Scholz J, D\u00f6rges V (2010) Management of the predicted difficult airway: a comparison of conventional blade laryngoscopy with video-assisted blade laryngoscopy and the GlideScope. Eur J Anaesthesiol 27(1):24\u201330","journal-title":"Eur J Anaesthesiol"},{"issue":"4","key":"995_CR21","doi-asserted-by":"crossref","first-page":"546","DOI":"10.1093\/bja\/aep013","volume":"102","author":"A Jungbauer","year":"2009","unstructured":"Jungbauer A, Schumann M, Brunkhorst V, B\u00f6rgers A, Groeben H (2009) Expected difficult tracheal intubation: a prospective comparison of direct laryngoscopy and video laryngoscopy in 200 patients. Br J Anaesth 102(4):546\u2013550","journal-title":"Br J Anaesth"}],"container-title":["Internal and Emergency Medicine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11739-013-0995-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11739-013-0995-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11739-013-0995-x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,1]],"date-time":"2019-06-01T17:28:46Z","timestamp":1559410126000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11739-013-0995-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,9,4]]},"references-count":21,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2014,2]]}},"alternative-id":["995"],"URL":"https:\/\/doi.org\/10.1007\/s11739-013-0995-x","relation":{"has-review":[{"id-type":"doi","id":"10.3410\/f.718100181.793511806","asserted-by":"object"}]},"ISSN":["1828-0447","1970-9366"],"issn-type":[{"value":"1828-0447","type":"print"},{"value":"1970-9366","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,9,4]]}}}