{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T22:36:36Z","timestamp":1790202996886,"version":"4.1.0"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2017,4,19]],"date-time":"2017-04-19T00:00:00Z","timestamp":1492560000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Gen Thorac Cardiovasc Surg"],"published-print":{"date-parts":[[2017,8]]},"DOI":"10.1007\/s11748-017-0778-9","type":"journal-article","created":{"date-parts":[[2017,4,19]],"date-time":"2017-04-19T09:46:16Z","timestamp":1492595176000},"page":"435-440","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["10-year results of On-X bileaflet mechanical heart valve in the aortic position: low target INR regimen in Japanese"],"prefix":"10.1007","volume":"65","author":[{"given":"Hideki","family":"Teshima","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masahiko","family":"Ikebuchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yosuke","family":"Miyamoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryuta","family":"Tai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshikazu","family":"Sano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yusuke","family":"Kinugasa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroyuki","family":"Irie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2017,4,19]]},"reference":[{"key":"778_CR1","unstructured":"Guidelines for management of anticoagulant and antiplatelet therapy in cardiovascular disease, revised on 10\/7\/2015. \n                        http:\/\/www.j-circ.or.jp\/guideline\/pdf\/JCS2009_hori_d.pdf\n                        \n                    . Accessed 30 Jan 2016."},{"issue":"4","key":"778_CR2","doi-asserted-by":"publisher","first-page":"1202","DOI":"10.1016\/j.jtcvs.2014.01.004","volume":"147","author":"J Puskas","year":"2014","unstructured":"Puskas J, Gerdisch M, Nichols D, Quinn R, Anderson C, Rhenman B, Fermin L, McGrath M, Kong B, Hughes C, Sethi G, Wait M, Martin T, Graeve A, PROACT Investigators. Reduced anticoagulation after mechanical aortic valve replacement: interim results from the prospective randomized on-X valve anticoagulation clinical trial randomized Food and Drug Administration investigational device exemption trial. J Thorac Cardiovasc Surg. 2014;147(4):1202\u201310. doi:\n                        10.1016\/j.jtcvs.2014.01.004\n                        \n                     (discussion 1210\u20131, Epub 2014 Jan 12).","journal-title":"J Thorac Cardiovasc Surg."},{"key":"778_CR3","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1016\/j.jacc.2006.05.021","volume":"48","author":"RO Bonow","year":"2006","unstructured":"Bonow RO, Carabello BA, Chatterjee K, de Leon AC, Jr Faxon DP, Freed MD, Gaasch WH, Lytle BW, Nishimura RA, O\u2019Gara PT, O\u2019Rourke RA, Otto CM, Shah PM, Shanewise JS, Smith SC Jr, Jacobs AK, Adams CD, Anderson JL, Antman EM, Fuster V, Halperin JL, Hiratzka LF, Hunt SA, Lytle BW, Nishimura R, Page RL, Riegel B. ACC\/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology\/American Heart Association Task Force on Practice Guidelines. J Am Coll Cardiol. 2006;48:e1\u2013148.","journal-title":"J Am Coll Cardiol"},{"key":"778_CR4","doi-asserted-by":"crossref","first-page":"881","DOI":"10.1016\/j.jtcvs.2008.09.028","volume":"137","author":"MW Geldorp van","year":"2009","unstructured":"van Geldorp MW, Eric Jamieson WR, Kappetein AP, Ye J, Fradet GJ, Eijkemans MJ, Grunkemeier GL, Bogers AJ, Takkenberg JJ. Patient outcome after aortic valve replacement with a mechanical or biological prosthesis: weighing lifetime anticoagulant-related event risk against reoperation risk. J Thorac Cardiovasc Surg. 2009;137:881\u20136.","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"3","key":"778_CR5","doi-asserted-by":"publisher","first-page":"258","DOI":"10.1007\/s10047-014-0770-4","volume":"17","author":"H Teshima","year":"2014","unstructured":"Teshima H, Ikebuchi M, Sano T, Tai R, Horio N, Irie H. Mid-term results of 17-mm St. Jude Medical Regent prosthetic valves in elder patients with small aortic annuli: comparison with 19-mm bioprosthetic valves. J Artif Organs. 2014;17(3):258\u201364. doi:\n                        10.1007\/s10047-014-0770-4\n                        \n                     (Epub 2014 May 31).","journal-title":"J Artif Organs."},{"key":"778_CR6","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1253\/circj.CJ-11-0733","volume":"76","author":"H Okamura","year":"2012","unstructured":"Okamura H, Yamaguchi A, Nagano H, Itoh S, Morita H, Naito K, Yuri K, Adachi H. Mid-term outcomes after aortic valve replacement with the 17-mm St. Jude Medical Regent valve. Circ J. 2012;76:365\u201371.","journal-title":"Circ J."},{"key":"778_CR7","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1177\/021849230601400304","volume":"14","author":"S Sawaki","year":"2006","unstructured":"Sawaki S, Usui A, Abe T, Yoshikawa M, Akita T, Ueda Y. Late mortality and morbidity in elderly patients with mechanical heart valves. Asian Cardiovasc Thorac Ann. 2006;14:189\u201394.","journal-title":"Asian Cardiovasc Thorac Ann."},{"key":"778_CR8","doi-asserted-by":"crossref","first-page":"1152","DOI":"10.1016\/S0735-1097(00)00834-2","volume":"36","author":"K Hammermeister","year":"2000","unstructured":"Hammermeister K, Sethi GK, Henderson WG, Grover FL, Oprian C, Rahimtoola SH. Outcomes 15\u00a0years after valve replacement with a mechanical versus a bioprosthetic valve: final report of the Veterans Affairs randomized trial. J Am Coll Cardiol. 2000;36:1152\u20138.","journal-title":"J Am Coll Cardiol"},{"key":"778_CR9","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1136\/heart.89.5.481","volume":"89","author":"G Hanania","year":"2003","unstructured":"Hanania G. Which heart valve prosthesis for patients aged between 60 and 70\u00a0years? Heart. 2003;89:481\u20132.","journal-title":"Heart"},{"key":"778_CR10","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1067\/mtc.2001.115238","volume":"122","author":"SS Kahn","year":"2001","unstructured":"Kahn SS, Trento A, DeRobertis M, Kass RM, Sandhu M, Czer LS, Blanche C, Raissi S, Fontana GP, Cheng W, Chaux A, Matloff JM. Twenty-year comparison of tissue and mechanical valve replacement. J Thorac Cardiovasc Surg. 2001;122:257\u201369.","journal-title":"J Thorac Cardiovasc Surg"},{"key":"778_CR11","doi-asserted-by":"crossref","first-page":"1267","DOI":"10.1016\/j.jtcvs.2005.11.052","volume":"131","author":"V Chan","year":"2006","unstructured":"Chan V, Jamieson WR, Germann E, Chang F, Miyagishima RT, Burr LH, Janusz MT, Ling H, Fradet GJ. Performance of bioprostheses and mechanical prostheses assessed by composites of valve-related complications to 15\u00a0years after aortic valve replacement. J Thorac Cardiovasc Surg. 2006;131:1267\u201373.","journal-title":"J Thorac Cardiovasc Surg"},{"key":"778_CR12","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1016\/j.ejcts.2006.06.013","volume":"30","author":"A Kulik","year":"2006","unstructured":"Kulik A, Bedard P, Lam BK, Rubens FD, Hendry PJ, Masters RG, Mesana TG, Ruel M. Mechanical versus bioprosthetic valve replacements in middle-aged patients. Eur J Cardiothorac Surg. 2006;30:485\u201391.","journal-title":"Eur J Cardiothorac Surg"},{"key":"778_CR13","first-page":"115","volume":"102","author":"V Rao","year":"2000","unstructured":"Rao V, Jamieson WR, Ivanov J, Armstrong S, David TE. Prosthesis-patient mismatch affects survival after aortic valve replacement. Circulation. 2000;102:115\u20139.","journal-title":"Circulation"},{"key":"778_CR14","doi-asserted-by":"crossref","first-page":"732","DOI":"10.1016\/j.jtcvs.2007.12.002","volume":"135","author":"CW Akins","year":"2008","unstructured":"Akins CW, Miller DC, Turina MI, Kouchoukos NT, Blackstone EH, Grunkemeier GL, Takkenberg JJ, David TE, Butchart EG, Adams DH, Shahian DM, Hagl S, Mayer JE, Lytle BW, Councils of the American Association for Thoracic Surgery; Society of Thoracic Surgeons; European Association for Cardio-Thoracic Surgery; Ad Hoc Liaison Committee for Standardizing Definitions of Prosthetic Heart Valve Morbidity. Guidelines for reporting mortality and morbidity after cardiac valve interventions. J Thorac Cardiovasc Surg. 2008;135:732\u20138.","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"2","key":"778_CR15","doi-asserted-by":"publisher","first-page":"420","DOI":"10.1016\/j.jtcvs.2011.12.059","volume":"145","author":"JB Chambers","year":"2013","unstructured":"Chambers JB, Pomar JL, Mestres CA, Palatianos GM. Clinical event rates with the On-X bileaflet mechanical heart valve: a multicenterexperience with follow-up to 12 years. J Thorac Cardiovasc Surg. 2013;145(2):420\u20134. doi:\n                        10.1016\/j.jtcvs.2011.12.059\n                        \n                     (Epub 2012 Feb 17).","journal-title":"J Thorac Cardiovasc Surg"},{"key":"778_CR16","doi-asserted-by":"publisher","unstructured":"Chan V, Jamieson WR, Lam BK, Ruel M, Ling H, Fradet G, Mesana TG. Influence of the On-X mechanical prosthesis on intermediate-term major thromboembolism and hemorrhage: a prospective multicenter study. J Thorac Cardiovasc Surg. 2010;140(5):1053\u20138.e2. doi:\n                        10.1016\/j.jtcvs.2009.10.068\n                        \n                     (Epub 2010 May 23).","DOI":"10.1016\/j.jtcvs.2009.10.068"},{"issue":"5","key":"778_CR17","first-page":"551","volume":"16","author":"P Tossios","year":"2007","unstructured":"Tossios P, Reber D, Oustria M, Holland-Letz T, Germing A, Buchwald D, Laczkovics A. Single-center experience with the On-X prosthetic heart valve between 1996 and 2005. J Heart Valve Dis. 2007;16(5):551\u20137.","journal-title":"J Heart Valve Dis"},{"issue":"6","key":"778_CR18","doi-asserted-by":"crossref","first-page":"588","DOI":"10.1510\/icvts.2005.114843","volume":"4","author":"U Ozyurda","year":"2005","unstructured":"Ozyurda U, Akar AR, Uymaz O, Oguz M, Ozkan M, Yildirim C, Aslan A, Tasoz R. Early clinical experience with the On-X prosthetic heart valve. Interact Cardiovasc Thorac Surg. 2005;4(6):588\u201394 (Epub 2005 Sep 16).","journal-title":"Interact Cardiovasc Thorac Surg."},{"issue":"1","key":"778_CR19","first-page":"80","volume":"15","author":"MA Williams","year":"2006","unstructured":"Williams MA, van Riet S. The On-X heart valve: mid-term results in a poorly anticoagulated population. J Heart Valve Dis. 2006;15(1):80\u20136.","journal-title":"J Heart Valve Dis"},{"issue":"1","key":"778_CR20","first-page":"73","volume":"15","author":"KW McNicholas","year":"2006","unstructured":"McNicholas KW, Ivey TD, Metras J, Szentpetery S, Marra SW, Masters RG, Dilling EW, Slaughter MS, Mack MJ. North American multicenter experience with the On-X prosthetic heart valve. J Heart Valve Dis. 2006;15(1):73\u20138 (discussion 79).","journal-title":"J Heart Valve Dis."},{"key":"778_CR21","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1067\/mtc.2002.121162","volume":"123","author":"EG Butchart","year":"2002","unstructured":"Butchart EG, Payne N, Li HH, Buchan K, Mandana K, Grunkemeier GL. Better anticoagulation control improves survival after valve replacement. J Thorac Cardiovasc Surg. 2002;123:715\u201323.","journal-title":"J Thorac Cardiovasc Surg"},{"key":"778_CR22","doi-asserted-by":"crossref","first-page":"668","DOI":"10.1253\/circj.66.668","volume":"66","author":"K Matsuyama","year":"2002","unstructured":"Matsuyama K, Matsumoto M, Sugita T, Nishizawa J, Yoshida K, Tokuda Y, Matsuo T. Anticoagulant therapy in Japanese patients with mechanical mitral valves. Circ J. 2002;66:668\u201370.","journal-title":"Circ J"},{"key":"778_CR23","first-page":"83","volume":"8","author":"T Mori","year":"2002","unstructured":"Mori T, Asano M, Ohtake H, Bitoh A, Sekiguchi S, Matsuo Y, Aiba M, Yamada M, Kawada T, Takaba T. Anticoagulant therapy after prosthetic valve replacement -optimal PT-INR in Japanese patients. Ann Thorac Cardiovasc Surg. 2002;8:83\u20137.","journal-title":"Ann Thorac Cardiovasc Surg."},{"issue":"1","key":"778_CR24","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1016\/S1010-7940(02)00658-9","volume":"23","author":"JB Borman","year":"2003","unstructured":"Borman JB, De Riberolles C. Sorin Bicarbon bileaflet valve: a 10-year experience. Eur J Cardiothorac Surg. 2003;23(1):86\u201392.","journal-title":"Eur J Cardiothorac Surg"},{"issue":"3","key":"778_CR25","doi-asserted-by":"crossref","first-page":"847","DOI":"10.1016\/j.athoracsur.2006.04.042","volume":"82","author":"D Baykut","year":"2006","unstructured":"Baykut D, Grize L, Schindler C, Keil AS, Bernet F, Zerkowski HR. Eleven-year single-center experience with the ATS Open Pivot Bileaflet heart valve. Ann Thorac Surg. 2006;82(3):847\u201352.","journal-title":"Ann Thorac Surg"},{"issue":"11","key":"778_CR26","doi-asserted-by":"publisher","first-page":"1198","DOI":"10.1161\/CIRCULATIONAHA.113.002424","volume":"128","author":"J Hata","year":"2013","unstructured":"Hata J, Ninomiya T, Hirakawa Y, Nagata M, Mukai N, Gotoh S, Fukuhara M, Ikeda F, Shikata K, Yoshida D, Yonemoto K, Kamouchi M, Kitazono T, Kiyohara Y. Secular trends in cardiovascular disease and its risk factors in Japanese: half-century data from the Hisayama Study (1961\u20132009). Circulation. 2013;128(11):1198\u2013205. doi:\n                        10.1161\/CIRCULATIONAHA.113.002424\n                        \n                     (Epub 2013 Jul 31).","journal-title":"Circulation"},{"key":"778_CR27","unstructured":"Teshima H, Ikebuchi M, Sano T, Kinugasa Y, Nakaoka Y, Tadokoro M, Irie H. Evaluation of the On-X valve in the aortic position by multidetector-row CT. J Heart Valve Dis. 2015 (in press)."}],"container-title":["General Thoracic and Cardiovascular Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11748-017-0778-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11748-017-0778-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11748-017-0778-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,7,21]],"date-time":"2017-07-21T17:14:01Z","timestamp":1500657241000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11748-017-0778-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,4,19]]},"references-count":27,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2017,8]]}},"alternative-id":["778"],"URL":"https:\/\/doi.org\/10.1007\/s11748-017-0778-9","relation":{},"ISSN":["1863-6705","1863-6713"],"issn-type":[{"value":"1863-6705","type":"print"},{"value":"1863-6713","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,4,19]]}}}