{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T15:54:17Z","timestamp":1786982057656,"version":"build-2736575974"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2024,9,26]],"date-time":"2024-09-26T00:00:00Z","timestamp":1727308800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,9,26]],"date-time":"2024-09-26T00:00:00Z","timestamp":1727308800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Gen Thorac Cardiovasc Surg"],"published-print":{"date-parts":[[2025,6]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>Although cerebrospinal fluid drainage has been shown to reduce the risk of ischemic spinal cord injury, serious complications have also been reported. We have been using it selectively in a pressure- and volume-regulated method and aimed to evaluate its safety, and its validity in elective thoracic endovascular aortic repair in a propensity-matched cohort.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Among the 450 patients who underwent open surgery (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u2009169) or thoracic endovascular aortic repair (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u2009281) on the descending or thoracoabdominal aorta, 147 underwent cerebrospinal fluid drainage, which was prophylactic in 135 and therapeutic in 12. Prophylactic drainage was performed in elective open surgery under distal aortic perfusion (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200967) or in selected patients undergoing thoracic endovascular aortic repair (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200968).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Drainage-related complications were observed in 13 (9.6%), one of which was graded severe (0.74%). In patients undergoing prophylactic drainage, spinal cord injury was detected in 2\/135 (1.5%). In patients without prophylactic drainage, 15\/315 (4.8%) developed spinal cord injury. Therapeutic drainage was performed in 12 of these 15 patients, 10 of whom remained paralytic in varying degree. In the inverse probability weighted analysis of the patients undergoing elective thoracic endovascular aortic repair, the incidence of spinal cord injury was lower with prophylactic drainage (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.028).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Pressure- and volume-regulated spinal drainage rarely causes serious complications. Its prophylactic use seems beneficial in selected patients, including those undergoing thoracic endovascular aortic repair with high risk for spinal cord injury.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s11748-024-02085-z","type":"journal-article","created":{"date-parts":[[2024,9,26]],"date-time":"2024-09-26T06:02:14Z","timestamp":1727330534000},"page":"411-419","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Safety and validity of selective cerebrospinal fluid drainage in open and endovascular aortic repair"],"prefix":"10.1007","volume":"73","author":[{"given":"Yuko","family":"Ohashi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naoki","family":"Washiyama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daisuke","family":"Takahashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kazumasa","family":"Tsuda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masahiro","family":"Hirano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1488-716X","authenticated-orcid":false,"given":"Norihiko","family":"Shiiya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,9,26]]},"reference":[{"key":"2085_CR1","doi-asserted-by":"publisher","first-page":"631","DOI":"10.1067\/mva.2002.122024","volume":"35","author":"JS Coselli","year":"2002","unstructured":"Coselli JS, Lemaire SA, Koksoy C, Schmittling ZC, Curling PE. Cerebrospinal fluid drainage reduces paraplegia after thoracoabdominal aortic aneurysm repair: Results and a randomized clinical trial. J Vasc Surg. 2002;35:631\u20139.","journal-title":"J Vasc Surg"},{"key":"2085_CR2","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1016\/S0003-4975(02)03714-1","volume":"74","author":"AT Cheung","year":"2002","unstructured":"Cheung AT, Weiss SJ, McGarvey ML, Stecker MM, Hogan MS, Escherich A, et al. Interventions for reversing delayed-onset postoperative paraplegia after thoracic aortic reconstruction. Ann Thorac Surg. 2002;74:413\u201321.","journal-title":"Ann Thorac Surg"},{"key":"2085_CR3","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1016\/j.jvs.2005.04.016","volume":"42","author":"R Chiesa","year":"2005","unstructured":"Chiesa R, Melissano G, Marrocco-Trischitta MM, Givilini E, Setacci F. Spinal cord ischemia after elective stent-graft repair of the thoracic aorta. J Vasc Surg. 2005;42:11\u20137.","journal-title":"J Vasc Surg"},{"key":"2085_CR4","doi-asserted-by":"publisher","first-page":"1280","DOI":"10.1016\/j.athoracsur.2005.04.027","volume":"80","author":"AT Cheung","year":"2005","unstructured":"Cheung AT, Pochettino A, McGarvey ML, Appoo JJ, Fairman RM, Carpenter JP, et al. Strategies to manage paraplegia risk after endovascular stent repair of descending thoracic aortic aneurysms. Ann Thorac Surg. 2005;80:1280\u20139.","journal-title":"Ann Thorac Surg"},{"key":"2085_CR5","doi-asserted-by":"publisher","first-page":"e223","DOI":"10.1016\/j.jacc.2022.08.004","volume":"80","author":"EM Isselbacher","year":"2022","unstructured":"Isselbacher EM, Preventza O, Black JH, Augoustides JG, Beck AW, Bolen MA, et al. 2022 ACC\/AHA guideline for the diagnosis and management of aortic disease: a report of the American Heart Association\/American College of Cardiology Joint Committee on Clinical Practice Guidelines. J Am Coll Cardiol. 2022;80:e223\u2013393.","journal-title":"J Am Coll Cardiol"},{"issue":"1S","key":"2085_CR6","doi-asserted-by":"publisher","first-page":"55S","DOI":"10.1016\/j.jvs.2020.05.076","volume":"73","author":"GR Upchurch Jr","year":"2021","unstructured":"Upchurch GR Jr, Escobar GA, Azizzadeh A, Beck AW, Conrad MF, Matsumura JS, et al. Society for Vascular Surgery clinical practice guidelines of thoracic endovascular aortic repair for descending thoracic aortic aneurysms. J Vasc Surg. 2021;73(1S):55S-83S.","journal-title":"J Vasc Surg"},{"key":"2085_CR7","doi-asserted-by":"publisher","first-page":"623","DOI":"10.1067\/mva.2001.117334","volume":"34","author":"KD Weaver","year":"2001","unstructured":"Weaver KD, Wiseman DB, Farber M, Ewend MG, Marston W, Keagy BA. Complications of lumbar drainage after thoracoabdominal aortic aneurysm repair. J Vasc Surg. 2001;34:623\u20137.","journal-title":"J Vasc Surg"},{"key":"2085_CR8","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1016\/j.jvs.2008.07.076","volume":"49","author":"MM Wynn","year":"2009","unstructured":"Wynn MM, Mell MW, Tefera G, Hoch JR, Acher CW. Complications of spinal fluid drainage in thoracoabdominal aortic aneurysm repair: A report of 486 patients treated from 1987 to 2008. J Vasc Surg. 2009;49:29\u201335.","journal-title":"J Vasc Surg"},{"issue":"4","key":"2085_CR9","doi-asserted-by":"publisher","first-page":"1478","DOI":"10.1016\/j.jvs.2021.10.050","volume":"75","author":"Z Zhang","year":"2022","unstructured":"Zhang Z, Zhou Y, Lin S, Xiao J, Ai W, Zhang WW. Systematic review and meta-analysis of association of prophylactic cerebrospinal fluid drainage in preventing spinal cord ischemia after thoracic endovascular aortic repair. J Vasc Surg. 2022;75(4):1478\u201389.","journal-title":"J Vasc Surg"},{"issue":"4","key":"2085_CR10","doi-asserted-by":"publisher","first-page":"1466","DOI":"10.1016\/j.jvs.2021.10.015","volume":"75","author":"R Pini","year":"2022","unstructured":"Pini R, Faggioli G, Paraskevas KI, Alaidroos M, Palermo S, Gallitto E, et al. A systematic review and meta-analysis of the occurrence of spinal cord ischemia after endovascular repair of thoracoabdominal aortic aneurysms. J Vasc Surg. 2022;75(4):1466\u201377.","journal-title":"J Vasc Surg"},{"key":"2085_CR11","doi-asserted-by":"publisher","first-page":"552","DOI":"10.1016\/j.jtcvs.2020.04.126","volume":"163","author":"M Gaudino","year":"2020","unstructured":"Gaudino M, Khan FM, Rahouma M, Naik A, Hameed I, Spadaccio C, et al. Spinal cord injury after open and endovascular repair of descending thoracic and thoracoabdominal aortic aneurysms: a meta-analysis. J Thorac Cardiovasc Surg. 2020;163:552\u201364.","journal-title":"J Thorac Cardiovasc Surg"},{"key":"2085_CR12","doi-asserted-by":"publisher","first-page":"904","DOI":"10.1016\/j.bja.2017.12.045","volume":"120","author":"LQ Rong","year":"2018","unstructured":"Rong LQ, Kamel MK, Rahouma M, White RS, Lichtman AD, Pryor KO, et al. Cerebrospinal-fluid drain-related complications in patients undergoing open and endovascular repairs of thoracic and thoraco-abdominal aortic pathologies: a systematic review and meta-analysis. Br J Anaesth. 2018;120:904\u201313.","journal-title":"Br J Anaesth"},{"key":"2085_CR13","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1016\/j.xjtc.2022.05.001","volume":"14","author":"JR Spratt","year":"2022","unstructured":"Spratt JR, Walker KL, Wallen TJ, Neal D, Zasimovich Y, Arnaoutakis GJ, et al. Safety of cerebrospinal fluid drainage for spinal cord ischemia prevention in thoracic endovascular aortic repair. JTCVS Tech. 2022;14:9\u201328.","journal-title":"JTCVS Tech"},{"key":"2085_CR14","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1067\/mva.2002.125022","volume":"36","author":"A Dardik","year":"2002","unstructured":"Dardik A, Perler BA, Roseborough GS, Williams GM. Subdural hematoma after thoracoabdominal aortic aneurysm repair: an underreported complication of spinal fluid drainage? J Vasc Surg. 2002;36:47\u201350.","journal-title":"J Vasc Surg"},{"key":"2085_CR15","doi-asserted-by":"publisher","first-page":"897","DOI":"10.1177\/15266028211028226","volume":"28","author":"R Pini","year":"2021","unstructured":"Pini R, Faggioli G, Fenelli C, Gallitto E, Mascoli C, Spath P, et al. Intracranial hemorrhage after endovascular repair of thoracoabdominal aortic aneurysm. J Endovasc Ther. 2021;28:897\u2013905.","journal-title":"J Endovasc Ther"},{"key":"2085_CR16","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1016\/j.athoracsur.2009.03.039","volume":"88","author":"AL Estrera","year":"2009","unstructured":"Estrera AL, Sheinbaum R, Miller CC, Azizzadeh A, Walkes JC, Lee TY, et al. Cerebrospinal fluid drainage during thoracic aortic repair: safety and current management. Ann Thorac Surg. 2009;88:9\u201315.","journal-title":"Ann Thorac Surg"},{"issue":"6","key":"2085_CR17","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.xjtc.2020.12.039","volume":"9","author":"M Abdelbaky","year":"2021","unstructured":"Abdelbaky M, Papanikolaou D, Zafar MA, Ellauzi H, Shaikh M, Ziganshin BA, et al. Safety of perioperative cerebrospinal fluid drain as a protective strategy during descending and thoracoabdominal open aortic repair. JTCVS Tech. 2021;9(6):1\u20138.","journal-title":"JTCVS Tech"},{"key":"2085_CR18","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1510\/icvts.2011.272211","volume":"13","author":"M Field","year":"2011","unstructured":"Field M, Doolan J, Safar M, Kuduvalli M, Oo A, Milli K, et al. The safe use of spinal drains in thoracic aortic surgery. Interact Cardiovasc Thorac Surg. 2011;13:557\u201365.","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"2085_CR19","doi-asserted-by":"publisher","first-page":"1109","DOI":"10.1016\/j.jvs.2019.06.210","volume":"71","author":"JM K\u00e4rkk\u00e4inen","year":"2020","unstructured":"K\u00e4rkk\u00e4inen JM, Cirillo-Penn NC, Sen I, Tenorio ER, Mauermann WJ, Gilkey GD, et al. Cerebrospinal fluid drainage complications during first stage and completion fenestrated-branched endovascular aortic repair. J Vasc Surg. 2020;71:1109\u201318.","journal-title":"J Vasc Surg"},{"key":"2085_CR20","doi-asserted-by":"publisher","first-page":"399","DOI":"10.1016\/j.jvs.2020.05.070","volume":"73","author":"N Kitpanit","year":"2021","unstructured":"Kitpanit N, Ellozy SH, Connolly PH, Agrusa CJ, Lichtman AD, Schneider DB. Risk factors for spinal cord injury and complications of cerebrospinal fluid drainage in patients undergoing fenestrated and branched endovascular aneurysm repair. J Vasc Surg. 2021;73:399\u2013409.","journal-title":"J Vasc Surg"},{"key":"2085_CR21","doi-asserted-by":"publisher","first-page":"1440","DOI":"10.1016\/j.jvs.2021.04.031","volume":"74","author":"SP Lyden","year":"2021","unstructured":"Lyden SP, Ahmed A, Steenberge S, Caputo FJ, Smolock CJ, Kirksey L, et al. Spinal drainage complications after aortic surgery. J Vasc Surg. 2021;74:1440\u20136.","journal-title":"J Vasc Surg"},{"key":"2085_CR22","doi-asserted-by":"publisher","first-page":"ezac441","DOI":"10.1093\/ejcts\/ezac441","volume":"62","author":"Y Seike","year":"2022","unstructured":"Seike Y, Fukuda T, Yokawa K, Koizumi S, Masada K, Inoue Y, et al. Aggressive use of prophylactic cerebrospinal fluid drainage to prevent spinal cord ischemia during thoracic endovascular aortic repair is not supportive. Eur J Cardiothorac Surg. 2022;62:ezac441.","journal-title":"Eur J Cardiothorac Surg"},{"key":"2085_CR23","doi-asserted-by":"publisher","first-page":"1029","DOI":"10.1016\/j.jtcvs.2010.06.017","volume":"141","author":"CD Etz","year":"2011","unstructured":"Etz CD, Kari FA, Mueller CS, Brenner RM, Lin HM, Griepp RB. The collateral network concept: remodeling of the arterial collateral network after experimental segmental artery sacrifice. J Thorac Cardiovasc Surg. 2011;141:1029\u201336.","journal-title":"J Thorac Cardiovasc Surg"},{"key":"2085_CR24","doi-asserted-by":"publisher","first-page":"2404","DOI":"10.21037\/jtd.2017.07.03","volume":"9","author":"S Song","year":"2017","unstructured":"Song S, Song SW, Kim TH, Lee KH, Yoo KJ. Effects of preemptive cerebrospinal fluid drainage on spinal cord protection during thoracic endovascular aortic repair. J Thorac Dis. 2017;9:2404\u201312.","journal-title":"J Thorac Dis"},{"key":"2085_CR25","doi-asserted-by":"publisher","first-page":"308","DOI":"10.1016\/j.jvs.2008.07.093","volume":"49","author":"FJ Schl\u00f6sser","year":"2009","unstructured":"Schl\u00f6sser FJ, Verhagen HJM, Lin PH, Verhoeven ELG, Herwaarden JA, Moll FL, et al. TEVAR following prior abdominal aortic aneurysm surgery: increased risk of neurological deficit. J Vasc Surg. 2009;49:308\u201314.","journal-title":"J Vasc Surg"},{"key":"2085_CR26","doi-asserted-by":"publisher","first-page":"1438","DOI":"10.1016\/j.jvs.2012.05.075","volume":"56","author":"CS Wong","year":"2012","unstructured":"Wong CS, Healy D, Canning C, Coffey JC, Boyle JR, Walsh SR. A systematic review of spinal cord injury and cerebrospinal fluid drainage after thoracic aortic endografting. J Vasc Surg. 2012;56:1438\u201347.","journal-title":"J Vasc Surg"},{"key":"2085_CR27","doi-asserted-by":"publisher","first-page":"1067","DOI":"10.1016\/j.jvs.2021.01.075","volume":"74","author":"V Aucoin","year":"2021","unstructured":"Aucoin V, Bolaji B, Novak Z, Spangler EL, Sutzko DC, McFarland GE, et al. Trends in the use of cerebrospinal drains and outcomes related to spinal cord ischemia after thoracic endovascular aortic repair and complex endovascular aortic repair in the Vascular Quality Initiative database. J Vasc Surg. 2021;74:1067\u201378.","journal-title":"J Vasc Surg"},{"key":"2085_CR28","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1016\/j.jvs.2018.10.112","volume":"70","author":"A Suarez-Pierre","year":"2019","unstructured":"Suarez-Pierre A, Zhou X, Gonzalez JE, Rizwan M, Fraser CD III, Lui C, et al. Association of preoperative spinal drain placement with spinal cord ischemia among patients undergoing thoracic and thoracoabdominal endovascular aortic repair. J Vasc Surg. 2019;70:393\u2013403.","journal-title":"J Vasc Surg"}],"container-title":["General Thoracic and Cardiovascular Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11748-024-02085-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11748-024-02085-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11748-024-02085-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,21]],"date-time":"2025-05-21T06:08:46Z","timestamp":1747807726000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11748-024-02085-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,26]]},"references-count":28,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2025,6]]}},"alternative-id":["2085"],"URL":"https:\/\/doi.org\/10.1007\/s11748-024-02085-z","relation":{},"ISSN":["1863-6705","1863-6713"],"issn-type":[{"value":"1863-6705","type":"print"},{"value":"1863-6713","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,9,26]]},"assertion":[{"value":"26 January 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 September 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 September 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no conflicts of interest in association with the present study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}