{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,11]],"date-time":"2026-07-11T05:50:52Z","timestamp":1783749052249,"version":"3.55.0"},"reference-count":12,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2021,1,6]],"date-time":"2021-01-06T00:00:00Z","timestamp":1609891200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,1,6]],"date-time":"2021-01-06T00:00:00Z","timestamp":1609891200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ir J Med Sci"],"published-print":{"date-parts":[[2021,11]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>To explore the clinical significance of digital tomographic fusion imaging in the diagnosis of avascular disease of the femoral head in adults.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Eighty-two adult patients with avascular necrosis of the femoral head confirmed by MRI in the department of orthopedics of our hospital were studied retrospectively. The related signs of adult avascular necrosis of the femoral head were diagnosed by digital tomographic fusion imaging, and the detection rates of digital X-ray (DR) and digital tomosynthesis (DTS) were compared to clarify the clinical value of digital tomographic fusion imaging in the diagnosis of adult avascular necrosis of the femoral head.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>DTS detected DR and 78 cases identified 55 cases. Taking the results of CT\/MRI as the gold standard, the sensitivity, specificity, positive predictive value, and negative predictive value of DR and DTS in the diagnosis of ANFH were calculated. There was a significant difference in the detection rate between the two methods (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.05).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>The digital tomographic fusion imaging technique has the advantages of high detection rate and excellent image quality, is economical, and is worth popularizing. For those with negative X-rays, DTS diagnosis and CT or\/and MRI can avoid unnecessary CT and MRI examinations, which is helpful to reduce the waste of medical resources.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s11845-020-02451-9","type":"journal-article","created":{"date-parts":[[2021,1,6]],"date-time":"2021-01-06T00:13:58Z","timestamp":1609892038000},"page":"1585-1589","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Clinical value of digital tomographic fusion imaging in the diagnosis of avascular necrosis of the femoral head in adults"],"prefix":"10.1007","volume":"190","author":[{"given":"Jiangang","family":"Zhang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhuhai","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ge","family":"Hong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,1,6]]},"reference":[{"key":"2451_CR1","doi-asserted-by":"publisher","first-page":"107089","DOI":"10.1016\/j.compbiolchem.2019.107089","volume":"83","author":"RS da Silva","year":"2019","unstructured":"da Silva RS, Marins LF, Almeida DV et al (2019) A comparison of classifiers for predicting the class color of fluorescent proteins. Comput Biol Chem 83:107089","journal-title":"Comput Biol Chem"},{"key":"2451_CR2","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1016\/j.revmed.2019.10.332","volume":"41","author":"L Pijnenburg","year":"2020","unstructured":"Pijnenburg L, Felten R, Javier RM (2020) A review of avascular necrosis, of the hip and beyond. Rev Med Interne 41:27\u201336","journal-title":"Rev Med Interne"},{"key":"2451_CR3","doi-asserted-by":"publisher","first-page":"779","DOI":"10.1016\/j.arth.2019.10.003","volume":"35","author":"EM Debbi","year":"2019","unstructured":"Debbi EM, Rajaee SS, Mayeda BF, Penenberg BL (2019) Determining and achieving target limb length and offset in total hip arthroplasty using intraoperative digital radiography. J Arthroplast\u00a035:779\u2013785","journal-title":"J Arthroplast"},{"key":"2451_CR4","doi-asserted-by":"publisher","first-page":"635","DOI":"10.1002\/mp.12735","volume":"45","author":"K Berggren","year":"2018","unstructured":"Berggren K, Cederstrom B, Lundqvist M, Fredenberg E (2018) Technical note: comparison of first- and second-generation photon-counting slit-scanning tomosynthesis systems. Med Phys 45:635\u2013638","journal-title":"Med Phys"},{"key":"2451_CR5","doi-asserted-by":"publisher","first-page":"1072","DOI":"10.1002\/ca.22952","volume":"30","author":"BS Koo","year":"2017","unstructured":"Koo BS, Song Y, Lee S et al (2017) Prevalence and distribution of sesamoid bones and accessory ossicles of the foot as determined by digital tomosynthesis. Clin Anat 30:1072\u20131076","journal-title":"Clin Anat"},{"key":"2451_CR6","doi-asserted-by":"publisher","first-page":"608","DOI":"10.1002\/ca.22881","volume":"30","author":"BS Koo","year":"2017","unstructured":"Koo BS, Song Y, Sung YK et al (2017) Prevalence and distribution of sesamoid bones in the hand determined using digital tomosynthesis. Clin Anat 30:608\u2013613","journal-title":"Clin Anat"},{"key":"2451_CR7","doi-asserted-by":"publisher","first-page":"e1327","DOI":"10.1016\/j.eats.2019.07.008","volume":"8","author":"JN Liu","year":"2019","unstructured":"Liu JN, Shields TG, Gowd AK, Amin NH (2019) Surgical treatment of insufficiency fractures of the knee. Arthrosc Tech 8:e1327\u2013e1332","journal-title":"Arthrosc Tech"},{"key":"2451_CR8","doi-asserted-by":"publisher","first-page":"1258","DOI":"10.1007\/s00330-018-5717-3","volume":"29","author":"R Gillet","year":"2019","unstructured":"Gillet R, Teixeira P, Bonarelli C et al (2019) Comparison of radiographs, tomosynthesis and ct with metal artifact reduction for the detection of hip prosthetic loosening. Eur Radiol 29:1258\u20131266","journal-title":"Eur Radiol"},{"key":"2451_CR9","doi-asserted-by":"publisher","first-page":"173","DOI":"10.2214\/AJR.18.20072","volume":"212","author":"AS Ha","year":"2019","unstructured":"Ha AS, Cunningham SX, Leung AS et al (2019) Weightbearing digital tomosynthesis of foot and ankle arthritis: comparison with radiography and simulated weightbearing ct in a prospective study. AJR Am J Roentgenol 212:173\u2013179","journal-title":"AJR Am J Roentgenol"},{"key":"2451_CR10","doi-asserted-by":"publisher","first-page":"941","DOI":"10.1007\/s00590-015-1632-3","volume":"25","author":"N Al-Mokhtar","year":"2015","unstructured":"Al-Mokhtar N, Shah J, Marson B et al (2015) Initial clinical experience of the use of digital tomosynthesis in the assessment of suspected fracture neck of femur in the elderly. Eur J Orthop Surg Traumatol 25:941\u2013947","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"2451_CR11","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1016\/j.ejmp.2018.07.011","volume":"53","author":"T Gomi","year":"2018","unstructured":"Gomi T, Sakai R, Goto M et al (2018) Development of a novel algorithm for metal artifact reduction in digital tomosynthesis using projection-based dual-energy material decomposition for arthroplasty: a phantom study. Phys Med 53:4\u201316","journal-title":"Phys Med"},{"key":"2451_CR12","doi-asserted-by":"publisher","first-page":"4553","DOI":"10.1002\/mp.13750","volume":"46","author":"D Oravec","year":"2019","unstructured":"Oravec D, Flynn MJ, Zauel R et al (2019) Digital tomosynthesis based digital volume correlation: a clinically viable noninvasive method for direct measurement of intravertebral displacements using images of the human spine under physiological load. Med Phys 46:4553\u20134562","journal-title":"Med Phys"}],"container-title":["Irish Journal of Medical Science (1971 -)"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11845-020-02451-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11845-020-02451-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11845-020-02451-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,10,16]],"date-time":"2021-10-16T13:26:25Z","timestamp":1634390785000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11845-020-02451-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,6]]},"references-count":12,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2021,11]]}},"alternative-id":["2451"],"URL":"https:\/\/doi.org\/10.1007\/s11845-020-02451-9","relation":{},"ISSN":["0021-1265","1863-4362"],"issn-type":[{"value":"0021-1265","type":"print"},{"value":"1863-4362","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1,6]]},"assertion":[{"value":"6 January 2021","order":1,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"The research plan has been submitted to the ethics committee of The Third Hospital of Hebei Medical University for approval. The committee issued a positive decision No. 2018-02 on August 31, 2018. The ethics committee of medical college is part of a large medical university in Shi Jiazhuang. The written informed consent for participation was obtained from the caregivers and relatives of all participants.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}}]}}