{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T14:14:48Z","timestamp":1740147288420,"version":"3.37.3"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2024,5,22]],"date-time":"2024-05-22T00:00:00Z","timestamp":1716336000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,5,22]],"date-time":"2024-05-22T00:00:00Z","timestamp":1716336000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ir J Med Sci"],"published-print":{"date-parts":[[2024,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Medical procedures in the field of electrocardiology belong to a large group of cardiological procedures. Performing them involves exposure to ionizing radiation. In this study, five medical procedures in the field of electrocardiology performed in three medical facilities were analyzed in terms of patients\u2019 exposure to ionizing radiation. A total of 178 patients were analyzed. Depending on the type of procedure, the recorded doses ranged from 7.4 to 614.62\u00a0mGy. The majority of electrocardiological procedures are pacemaker implantations 38% and RF ablation 33%. The results obtained show a significant dispersion of the recorded dose values in the same type of treatment. This is reflected, for example, in the high coefficient of variation for doses in RF ablation. The type of X-ray machine used during the procedure also influences the dose values. Although the exposure of patients undergoing electrocardiological procedures to ionizing radiation is much lower than in the case of cardiac vascular procedures, it may reach a similar level, especially in the case of implantation of devices regulating the correct functioning of the heart.<\/jats:p>","DOI":"10.1007\/s11845-024-03717-2","type":"journal-article","created":{"date-parts":[[2024,5,22]],"date-time":"2024-05-22T14:02:12Z","timestamp":1716386532000},"page":"2217-2221","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Analysis of ionizing radiation doses received by patients during electrocardiological procedures"],"prefix":"10.1007","volume":"193","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0283-5912","authenticated-orcid":false,"given":"Micha\u0142","family":"Biega\u0142a","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"\u0141ukasz","family":"Z\u0105bczy\u0144ski","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2051-2594","authenticated-orcid":false,"given":"Maria Anna","family":"Staniszewska","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,5,22]]},"reference":[{"issue":"6","key":"3717_CR1","doi-asserted-by":"publisher","first-page":"711","DOI":"10.1097\/01.rvi.0000079980.80153.4b","volume":"14","author":"DL Miller","year":"2003","unstructured":"Miller DL et al (2003) RAD-IR study. Radiation doses in interventional radiology procedures: the RAD-IR study: part I: overall measures of dose. J Vasc Interv Radiol 14(6):711\u2013727. https:\/\/doi.org\/10.1097\/01.rvi.0000079980.80153.4b","journal-title":"J Vasc Interv Radiol"},{"issue":"8","key":"3717_CR2","doi-asserted-by":"publisher","first-page":"977","DOI":"10.1097\/01.RVI.0000084601.43811.CB","volume":"14","author":"DL Miller","year":"2003","unstructured":"Miller DL et al (2003) Radiation doses in interventional radiology procedures: the RAD-IR study: part II: skin dose. J Vasc Interv Radiol 14(8):977\u2013990","journal-title":"J Vasc Interv Radiol"},{"issue":"9","key":"3717_CR3","doi-asserted-by":"publisher","first-page":"919","DOI":"10.1097\/01.RVI.0000130864.68139.08","volume":"15","author":"S Balter","year":"2004","unstructured":"Balter S et al (2004) Radiation doses in interventional radiology procedures: the RAD-IR study. Part III: Dosimetric performance of the interventional fluoroscopy units. J Vasc Interv Radiol 15(9):919\u2013926. https:\/\/doi.org\/10.1097\/01.RVI.0000130864.68139.08","journal-title":"J Vasc Interv Radiol"},{"issue":"842","key":"3717_CR4","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1259\/bjr.71.842.9579182","volume":"71","author":"BJ McParland","year":"1998","unstructured":"McParland BJ (1998) A study of patient radiation doses in interventional radiological procedures. Br J Radiol 71(842):175\u2013185","journal-title":"Br J Radiol"},{"issue":"10","key":"3717_CR5","doi-asserted-by":"publisher","first-page":"4281","DOI":"10.1007\/s00330-017-4780-5","volume":"27","author":"C Etard","year":"2017","unstructured":"Etard C et al (2017) Patient dose in interventional radiology: a multicentre study of the most frequent procedures in France. Eur Radiol 27(10):4281\u20134290","journal-title":"Eur Radiol"},{"issue":"12","key":"3717_CR6","doi-asserted-by":"publisher","first-page":"9346","DOI":"10.1007\/s00330-021-08029-y","volume":"31","author":"AA Schegerer","year":"2021","unstructured":"Schegerer AA et al (2021) Radiation dose and diagnostic reference levels for four interventional radiology procedures: results of the prospective European multicenter survey EUCLID. Eur Radiol 31(12):9346\u20139360","journal-title":"Eur Radiol"},{"issue":"36","key":"3717_CR7","doi-asserted-by":"publisher","first-page":"3599","DOI":"10.1093\/eurheartj\/ehab368","volume":"42","author":"TA McDonagh","year":"2021","unstructured":"McDonagh TA et al (2021) ESC scientific document group. 2021 ESC guidelines for the diagnosis and treatment of acute and chronic heart failure. Eur Heart J 42(36):3599\u20133726","journal-title":"Eur Heart J"},{"issue":"1","key":"3717_CR8","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1016\/j.ccep.2010.10.012","volume":"3","author":"C Antzelevitch","year":"2011","unstructured":"Antzelevitch C, Burashnikov A (2011) Overview of basic mechanisms of cardiac arrhythmia. Card Electrophysiol Clin 3(1):23\u201345","journal-title":"Card Electrophysiol Clin"},{"issue":"6","key":"3717_CR9","doi-asserted-by":"publisher","first-page":"3681","DOI":"10.19102\/icrm.2019.100604","volume":"10","author":"A Jafferani","year":"2019","unstructured":"Jafferani A, Leal MA (2019) Advances in cardiac resynchronization therapy. J Innov Card Rhythm Manag 10(6):3681\u20133693","journal-title":"J Innov Card Rhythm Manag"},{"issue":"3","key":"3717_CR10","doi-asserted-by":"publisher","first-page":"e005515","DOI":"10.1161\/JAHA.117.005515","volume":"6","author":"RT Borne","year":"2017","unstructured":"Borne RT et al (2017) Implantable cardioverter-defibrillators for secondary prevention of sudden cardiac death a review. J Am Heart Assoc 6(3):e005515","journal-title":"J Am Heart Assoc"},{"key":"3717_CR11","unstructured":"Regulation of the Minister of Health of December 6, 2022 on diagnostic reference levels\u00a0Dz.U. 2022 poz.\u00a02626"},{"issue":"2","key":"3717_CR12","doi-asserted-by":"publisher","first-page":"589","DOI":"10.1007\/s13246-022-01126-2","volume":"45","author":"KS Wilson-Stewart","year":"2022","unstructured":"Wilson-Stewart KS, Fontanarosa D, Malacova E, Trapp JV (2022) Impact of dose reducing software on patient and staff temple dose during fluoroscopically guided pacemaker insertion, closure devices implantation and coronary angiography procedures. Phys Eng Sci Med 45(2):589\u2013599","journal-title":"Phys Eng Sci Med"},{"issue":"8","key":"3717_CR13","doi-asserted-by":"publisher","first-page":"866","DOI":"10.1016\/j.jcin.2012.05.003","volume":"5","author":"KA Fetterly","year":"2012","unstructured":"Fetterly KA et al (2012) Radiation dose reduction in the invasive cardiovascular laboratory: implementing a culture and philosophy of radiation safety. JACC Cardiovasc Interv 5(8):866\u2013873","journal-title":"JACC Cardiovasc Interv"},{"issue":"1","key":"3717_CR14","doi-asserted-by":"publisher","first-page":"2391","DOI":"10.1038\/s41598-023-28704-y","volume":"13","author":"KS Wilson-Stewart","year":"2023","unstructured":"Wilson-Stewart KS et al (2023) A comparison of patient dose and occupational eye dose to the operator and nursing staff during transcatheter cardiac and endovascular procedures. Sci Rep 13(1):2391","journal-title":"Sci Rep"},{"issue":"1","key":"3717_CR15","doi-asserted-by":"publisher","first-page":"12","DOI":"10.4103\/apc.APC_86_17","volume":"11","author":"D Balaguru","year":"2018","unstructured":"Balaguru D et al (2018) Comparison of skin dose measurement using nanoDot\u00ae dosimeter and machine readings of radiation dose during cardiac catheterization in children. Ann Pediatr Cardiol 11(1):12\u201316. https:\/\/doi.org\/10.4103\/apc.APC_86_17","journal-title":"Ann Pediatr Cardiol"}],"container-title":["Irish Journal of Medical Science (1971 -)"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11845-024-03717-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11845-024-03717-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11845-024-03717-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,3]],"date-time":"2024-10-03T11:21:39Z","timestamp":1727954499000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11845-024-03717-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,22]]},"references-count":15,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2024,10]]}},"alternative-id":["3717"],"URL":"https:\/\/doi.org\/10.1007\/s11845-024-03717-2","relation":{},"ISSN":["0021-1265","1863-4362"],"issn-type":[{"type":"print","value":"0021-1265"},{"type":"electronic","value":"1863-4362"}],"subject":[],"published":{"date-parts":[[2024,5,22]]},"assertion":[{"value":"21 March 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 May 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 May 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was conducted in accordance with the Declaration of Helsinki and approved by the Bioethical Commission of the Medical University of Lodz, Poland (approval no. RNN\/239\/23\/KE, date 10 October 2023).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interest"}}]}}