{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T01:28:44Z","timestamp":1790299724821,"version":"4.1.0"},"reference-count":38,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2020,2,17]],"date-time":"2020-02-17T00:00:00Z","timestamp":1581897600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,2,17]],"date-time":"2020-02-17T00:00:00Z","timestamp":1581897600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Curr Cardiol Rep"],"published-print":{"date-parts":[[2020,4]]},"DOI":"10.1007\/s11886-020-1276-8","type":"journal-article","created":{"date-parts":[[2020,2,18]],"date-time":"2020-02-18T15:24:45Z","timestamp":1582039485000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":36,"title":["3D Printing Applications for Transcatheter Aortic Valve Replacement"],"prefix":"10.1007","volume":"22","author":[{"given":"Dmitry","family":"Levin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G. Burkhard","family":"Mackensen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark","family":"Reisman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James M.","family":"McCabe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Danny","family":"Dvir","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Beth","family":"Ripley","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,2,17]]},"reference":[{"issue":"3","key":"1276_CR1","first-page":"415","volume":"7","author":"DD Wang","year":"2018","unstructured":"Wang DD, Gheewala N, Shah R, Levin D, Myers E, Rollet M, et al. Three-dimensional printing for planning of structural heart interventions. Interv Cardiol Clin. 2018;7(3):415\u201323.","journal-title":"Interv Cardiol Clin"},{"issue":"5","key":"1276_CR2","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1097\/RTI.0000000000000217","volume":"31","author":"AA Giannopoulos","year":"2016","unstructured":"Giannopoulos AA, Steigner ML, George E, Barile M, Hunsaker AR, Rybicki FJ, et al. Cardiothoracic applications of 3-dimensional printing. J Thorac Imaging. 2016;31(5):253\u201372.","journal-title":"J Thorac Imaging"},{"key":"1276_CR3","doi-asserted-by":"crossref","unstructured":"Bramlet M, Olivieri L, Farooqi K, Ripley B, Coakley M. Impact of three-dimensional printing on the study and treatment of congenital heart disease. Circ Res. 2017;120(6).","DOI":"10.1161\/CIRCRESAHA.116.310546"},{"issue":"2","key":"1276_CR4","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1016\/j.jcmg.2016.12.001","volume":"10","author":"M Vukicevic","year":"2017","unstructured":"Vukicevic M, Mosadegh B, Min JK, Little SH. Cardiac 3D printing and its future directions. JACC Cardiovasc Imaging. 2017;10(2):171\u201384.","journal-title":"JACC Cardiovasc Imaging"},{"issue":"4","key":"1276_CR5","doi-asserted-by":"publisher","first-page":"398","DOI":"10.1016\/j.echo.2015.02.005","volume":"28","author":"KM Farooqi","year":"2015","unstructured":"Farooqi KM, Sengupta PP. Echocardiography and three-dimensional printing: sound ideas to touch a heart. J Am Soc Echocardiogr. 2015;28(4):398\u2013403.","journal-title":"J Am Soc Echocardiogr"},{"issue":"2","key":"1276_CR6","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1016\/j.hfc.2014.12.003","volume":"11","author":"D Himbert","year":"2015","unstructured":"Himbert D, Vahanian A. Transcatheter aortic valve replacement for patients with heart failure. Heart Fail Clin. 2015;11(2):231\u201342.","journal-title":"Heart Fail Clin"},{"issue":"10034","key":"1276_CR7","doi-asserted-by":"publisher","first-page":"2218","DOI":"10.1016\/S0140-6736(16)30073-3","volume":"387","author":"VH Thourani","year":"2016","unstructured":"Thourani VH, Kodali S, Makkar RR, Herrmann HC, Williams M, Babaliaros V, et al. Transcatheter aortic valve replacement versus surgical valve replacement in intermediate-risk patients: a propensity score analysis. Lancet. 2016;387(10034):2218\u201325.","journal-title":"Lancet."},{"issue":"17","key":"1276_CR8","doi-asserted-by":"publisher","first-page":"1597","DOI":"10.1056\/NEJMoa1008232","volume":"363","author":"MB Leon","year":"2010","unstructured":"Leon MB, Smith CR, Mack M, Miller DC, Moses JW, Svensson LG, et al. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med. 2010;363(17):1597\u2013607.","journal-title":"N Engl J Med"},{"issue":"23","key":"1276_CR9","doi-asserted-by":"publisher","first-page":"2187","DOI":"10.1056\/NEJMoa1103510","volume":"364","author":"CR Smith","year":"2011","unstructured":"Smith CR, Leon MB, Mack MJ, Miller DC, Moses JW, Svensson LG, et al. Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med. 2011;364(23):2187\u201398.","journal-title":"N Engl J Med"},{"issue":"18","key":"1276_CR10","doi-asserted-by":"publisher","first-page":"1706","DOI":"10.1056\/NEJMoa1816885","volume":"380","author":"JJ Popma","year":"2019","unstructured":"Popma JJ, Deeb GM, Yakubov SJ, Mumtaz M, Gada H, O\u2019Hair D, et al. Transcatheter aortic-valve replacement with a self-expanding valve in low-risk patients. N Engl J Med. 2019;380(18):1706\u201315.","journal-title":"N Engl J Med"},{"issue":"7","key":"1276_CR11","doi-asserted-by":"publisher","first-page":"732","DOI":"10.1016\/j.jcmg.2017.05.002","volume":"10","author":"M Alkhouli","year":"2017","unstructured":"Alkhouli M, Sengupta PP. 3-dimensional\u2013printed models for TAVR planning. JACC Cardiovasc Imaging. 2017;10(7):732\u20134.","journal-title":"JACC Cardiovasc Imaging"},{"issue":"6","key":"1276_CR12","doi-asserted-by":"publisher","first-page":"366","DOI":"10.1016\/j.jcct.2012.11.002","volume":"6","author":"S Achenbach","year":"2012","unstructured":"Achenbach S, Delgado V, Hausleiter J, Schoenhagen P, Min JK, Leipsic J. a. SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)\/transcatheter aortic valve replacement (TAVR). J Cardiovasc Comput Tomogr. 2012;6(6):366\u201380.","journal-title":"J Cardiovasc Comput Tomogr."},{"issue":"2","key":"1276_CR13","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1016\/j.jcmg.2012.12.005","volume":"6","author":"AM Kasel","year":"2013","unstructured":"Kasel AM, Cassese S, Bleiziffer S, Amaki M, Hahn RT, Kastrati A, et al. Standardized imaging for aortic annular sizing: implications for transcatheter valve selection. JACC Cardiovasc Imaging. 2013;6(2):249\u201362.","journal-title":"JACC Cardiovasc Imaging"},{"key":"1276_CR14","doi-asserted-by":"crossref","unstructured":"\u2022 Faletti R, Gatti M, Cosentino A, Bergamasco L, Cura Stura E, Garabello D, et al. 3D printing of the aortic annulus based on cardiovascular computed tomography: Preliminary experience in pre-procedural planning for aortic valve sizing. J Cardiovasc Comput Tomogr. 2018;12(5):391\u2013397. In this original research paper, the authors 3D printed the aortic roots of 20 patients from CT data. They then compared measurements of 3D-printed aortic valve size to gold standard CT annular measurements and surgical valve sizing via Hegar dilators. No significant difference was found between intra-operative and 3D model measurements, thus verifying accuracy of the models for pre-surgical planning in this study.","DOI":"10.1016\/j.jcct.2018.05.016"},{"issue":"1","key":"1276_CR15","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1016\/j.jcct.2015.12.004","volume":"10","author":"B Ripley","year":"2016","unstructured":"Ripley B, Kelil T, Cheezum MK, Goncalves A, Di Carli MF, Rybicki FJ, et al. 3D printing based on cardiac CT assists anatomic visualization prior to transcatheter aortic valve replacement. J Cardiovasc Comput Tomogr. 2016;10(1):28\u201336.","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"1276_CR16","doi-asserted-by":"crossref","unstructured":"Bompotis G, Meletidou M, Karakanas A, Sotiriou S, Sachpekidis V, Konstantinidou M, et al. Transcatheter aortic valve implantation using 3-D printing modeling assistance. A single-center experience. Hell J Cardiol. 2019;1.","DOI":"10.1016\/j.hjc.2019.01.012"},{"key":"1276_CR17","unstructured":"Hosny A, Dilley JD, Kelil T, Mathur M, Dean MN, Weaver JC, et al. Pre-procedural fit-testing of TAVR valves using parametric modeling and 3D printing. J Cardiovasc Comput Tomogr. 2018; 2:1\u20130."},{"issue":"2","key":"1276_CR18","doi-asserted-by":"publisher","first-page":"e31","DOI":"10.1016\/j.athoracsur.2011.09.031","volume":"93","author":"D Schmauss","year":"2012","unstructured":"Schmauss D, Schmitz C, Bigdeli AK, Weber S, Gerber N, Beiras-Fernandez A, et al. Three-dimensional printing of models for preoperative planning and simulation of transcatheter valve replacement. Ann Thorac Surg. 2012;93(2):e31\u20133.","journal-title":"Ann Thorac Surg"},{"issue":"12","key":"1276_CR19","doi-asserted-by":"publisher","first-page":"1385","DOI":"10.1093\/ehjci\/jev343","volume":"17","author":"B Fujita","year":"2016","unstructured":"Fujita B, K\u00fctting M, Seiffert M, Scholtz S, Egron S, Prashovikj E, et al. Calcium distribution patterns of the aortic valve as a risk factor for the need of permanent pacemaker implantation after transcatheter aortic valve implantation. Eur Heart J Cardiovasc Imaging. 2016;17(12):1385\u201393.","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"1276_CR20","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1016\/j.ijcard.2017.11.106","volume":"258","author":"Y Tanaka","year":"2018","unstructured":"Tanaka Y, Saito S, Sasuga S, Takahashi A, Aoyama Y, Obama K, et al. Quantitative assessment of paravalvular leakage after transcatheter aortic valve replacement using a patient-specific pulsatile flow model. Int J Cardiol. 2018;258:313\u201320.","journal-title":"Int J Cardiol"},{"issue":"7","key":"1276_CR21","doi-asserted-by":"publisher","first-page":"719","DOI":"10.1016\/j.jcmg.2017.04.005","volume":"10","author":"Z Qian","year":"2017","unstructured":"\u2022\u2022 Qian Z, Wang K, Liu S, Zhou X, Rajagopal V, Meduri C, et al. Quantitative prediction of paravalvular leak in transcatheter aortic valve replacement based on tissue-mimicking 3D printing. JACC Cardiovasc Imaging. 2017;10(7):719\u201331 Building on Wang K et al (ref 38), the authors use a multimaterial 3D printing technique to create models that include hard calcifications and a meta-material meant to reproduce the stress-strain characteristics of aortic tissue. These models were CT scanned before and after benchtop deployment of a self-expanding stent to measure relative displacement of radiodense beads placed on the model surface. From this data, the authors propose a new assessment called the \u201cbulge index\u201d to predict which patients are at risk for paravalvular leak.","journal-title":"JACC Cardiovasc Imaging"},{"issue":"1","key":"1276_CR22","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1007\/s10439-018-02120-0","volume":"47","author":"H Hatoum","year":"2019","unstructured":"Hatoum H, Dollery J, Lilly SM, Crestanello JA, Dasi LP. Sinus hemodynamics variation with tilted transcatheter aortic valve deployments. Ann Biomed Eng. 2019;47(1):75\u201384.","journal-title":"Ann Biomed Eng"},{"issue":"2","key":"1276_CR23","doi-asserted-by":"publisher","first-page":"461","DOI":"10.1253\/circj.CJ-18-0582","volume":"83","author":"M Yamawaki","year":"2019","unstructured":"Yamawaki M, Obama K, Sasuga S, Takahashi A, Ito Y, Umezu M, et al. Underfilled balloon-expandable transcatheter aortic valve implantation with ad hoc post-dilation \u2015 pulsatile flow simulation using a patient-specific three-dimensional printing model \u2015. Circ J. 2019;83(2):461\u201370.","journal-title":"Circ J"},{"issue":"2","key":"1276_CR24","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1001\/jama.2014.7246","volume":"312","author":"D Dvir","year":"2014","unstructured":"Dvir D, Webb JG, Bleiziffer S, Pasic M, Waksman R, Kodali S, et al. Transcatheter aortic valve implantation in failed bioprosthetic surgical valves. JAMA. 2014;312(2):162\u201370.","journal-title":"JAMA."},{"issue":"19","key":"1276_CR25","doi-asserted-by":"publisher","first-page":"2335","DOI":"10.1161\/CIRCULATIONAHA.112.104505","volume":"126","author":"D Dvir","year":"2012","unstructured":"Dvir D, Webb J, Brecker S, Bleiziffer S, Hildick-Smith D, Colombo A, et al. Transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves. Circulation. 2012;126(19):2335\u201344.","journal-title":"Circulation."},{"key":"1276_CR26","doi-asserted-by":"crossref","unstructured":"Allen KB, Chhatriwalla AK, Cohen DJ, Saxon JT, Aggarwal S, Hart A, et al. Bioprosthetic valve fracture to facilitate transcatheter valve-in-valve implantation. In: Annals of Thoracic Surgery. 2017.","DOI":"10.1016\/j.athoracsur.2017.04.007"},{"key":"1276_CR27","first-page":"10(7)","volume":"1","author":"AK Chhatriwalla","year":"2017","unstructured":"Chhatriwalla AK, Allen KB, Saxon JT, Cohen DJ, Aggarwal S, Hart AJ, et al. Bioprosthetic valve fracture improves the hemodynamic results of valve-in-valve transcatheter aortic valve replacement. Circ Cardiovasc Interv. 2017;1:10(7).","journal-title":"Circ Cardiovasc Interv."},{"issue":"8","key":"1276_CR28","doi-asserted-by":"publisher","first-page":"696","DOI":"10.1093\/eurheartj\/ehx529","volume":"39","author":"B Iung","year":"2018","unstructured":"Iung B, Vahanian A. Coronary obstruction: a rare but devastating complication during transcatheter aortic valve-in-valve implantation. Eur Heart J. 2018;39(8):696\u20138.","journal-title":"Eur Heart J"},{"key":"1276_CR29","doi-asserted-by":"crossref","unstructured":"Dvir D, Webb JG, Piazza N, Blanke P, Barbanti M, Bleiziffer S, et al. Multicenter evaluation of transcatheter aortic valve replacement using either SAPIEN XT or CoreValve: degree of device oversizing by computed-tomography and clinical outcomes. Catheter Cardiovasc Interv. 2015;00(January):n\/a-n\/a.","DOI":"10.1002\/ccd.25823"},{"issue":"AB","key":"1276_CR30","doi-asserted-by":"publisher","first-page":"AB74","DOI":"10.4244\/EIJ-D-18-00667","volume":"14","author":"D Dvir","year":"2018","unstructured":"Dvir D, Khan J, Kornowski R, Komatsu I, Chatriwalla A, Mackenson GB, et al. Novel strategies in aortic valve-in-valve therapy including bioprosthetic valve fracture and BASILICA. EuroIntervention. 2018;14(AB):AB74\u201382.","journal-title":"EuroIntervention"},{"issue":"1","key":"1276_CR31","doi-asserted-by":"publisher","first-page":"47","DOI":"10.4244\/EIJ-D-19-00057","volume":"15","author":"I Komatsu","year":"2019","unstructured":"Komatsu I, Mackensen GB, Aldea GS, Reisman M, Dvir D. Bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction. Part 1: how to evaluate patients for BASILICA. EuroIntervention. 2019;15(1):47\u201354.","journal-title":"EuroIntervention."},{"key":"1276_CR32","doi-asserted-by":"crossref","unstructured":"Khan A, Gilani S, Dharmashankar K, Jaffery Z, Rangasetty UC, Fujise K. Percutaneous coronary intervention after transcatheter aortic valve replacement: approach and challenges. J Am Coll Cardiol. 2016.","DOI":"10.1016\/j.jacc.2016.04.051"},{"key":"1276_CR33","unstructured":"Yoon SH, Lef\u00e8vre T, Ahn JM, Perlman GY, Dvir D, Latib A, et al. Transcatheter aortic valve replacement with early- and new-generation devices in bicuspid aortic valve stenosis. J Am Coll Cardiol. 2016."},{"key":"1276_CR34","doi-asserted-by":"crossref","unstructured":"Sievers HH, Schmidtke C. A classification system for the bicuspid aortic valve from 304 surgical specimens. J Thorac Cardiovasc Surg. 2007.","DOI":"10.1016\/j.jtcvs.2007.01.039"},{"key":"1276_CR35","doi-asserted-by":"crossref","unstructured":"Jilaihawi H, Chen M, Webb J, Himbert D, Ruiz CE, Rod\u00e9s-Cabau J, et al. A bicuspid aortic valve imaging classification for the TAVR era. JACC Cardiovasc Imaging. 2016.","DOI":"10.1016\/j.jcmg.2015.12.022"},{"issue":"1","key":"1276_CR36","doi-asserted-by":"publisher","first-page":"e007107","DOI":"10.1161\/CIRCINTERVENTIONS.118.007107","volume":"12","author":"D Tchetche","year":"2019","unstructured":"Tchetche D, de Biase C, van Gils L, Parma R, Ochala A, Lefevre T, et al. Bicuspid aortic valve anatomy and relationship with devices: the BAVARD multicenter registry. Circ Cardiovasc Interv. 2019;12(1):e007107.","journal-title":"Circ Cardiovasc Interv"},{"key":"1276_CR37","doi-asserted-by":"publisher","first-page":"704","DOI":"10.1016\/j.matdes.2015.11.022","volume":"90","author":"K Wang","year":"2016","unstructured":"\u2022 Wang K, Zhao Y, Chang Y-H, Qian Z, Zhang C, Wang B, et al. Controlling the mechanical behavior of dual-material 3D printed meta-materials for patient-specific tissue-mimicking phantoms. Mater Des. 2016;90:704\u201312 This paper is the first description of a method for using sinusoidal elements and double helix structures printed out of high shore value material within flexible 3D printable material to mimic the stress-strain characteristics of arterial tissue.","journal-title":"Mater Des"},{"issue":"10","key":"1276_CR38","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1161\/CIRCIMAGING.115.003626","volume":"8","author":"D Maragiannis","year":"2015","unstructured":"Maragiannis D, Jackson MS, Igo SR, Schutt RC, Connell P, Grande-Allen J, et al. Replicating patient-specific severe aortic valve stenosis with functional 3D modeling. Circ Cardiovasc Imaging. 2015;8(10):1\u20138.","journal-title":"Circ Cardiovasc Imaging"}],"container-title":["Current Cardiology Reports"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11886-020-1276-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11886-020-1276-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11886-020-1276-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,2,18]],"date-time":"2021-02-18T23:48:49Z","timestamp":1613692129000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11886-020-1276-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2,17]]},"references-count":38,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2020,4]]}},"alternative-id":["1276"],"URL":"https:\/\/doi.org\/10.1007\/s11886-020-1276-8","relation":{},"ISSN":["1523-3782","1534-3170"],"issn-type":[{"value":"1523-3782","type":"print"},{"value":"1534-3170","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,2,17]]},"assertion":[{"value":"17 February 2020","order":1,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with Ethical Standards"}},{"value":"Dmitry Levin, G. Burkhard Mackensen, Mark Reisman, James McCabe, Danny Dvir, and Beth Ripley declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of Interest"}},{"value":"All procedures performed in studies involving human participants by the authors were in accordance with the ethical standards of the institutional and\/or national research committee (University of Washington Human Subjects Division + HSD Study # STUDY00003286) and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Human and Animal Rights and Informed Consent"}}],"article-number":"23"}}