{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,18]],"date-time":"2025-12-18T08:45:13Z","timestamp":1766047513220,"version":"3.37.3"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2023,10,10]],"date-time":"2023-10-10T00:00:00Z","timestamp":1696896000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,10,10]],"date-time":"2023-10-10T00:00:00Z","timestamp":1696896000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Curr Cardiol Rep"],"published-print":{"date-parts":[[2023,11]]},"DOI":"10.1007\/s11886-023-01959-7","type":"journal-article","created":{"date-parts":[[2023,10,10]],"date-time":"2023-10-10T10:02:15Z","timestamp":1696932135000},"page":"1425-1431","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["TAVR in TAVR: Where Are We in 2023 for Management of Failed TAVR Valves?"],"prefix":"10.1007","volume":"25","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5524-5844","authenticated-orcid":false,"given":"David","family":"Meier","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Georgios","family":"Tzimas","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mariama","family":"Akodad","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stephane","family":"Fournier","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jonathon A.","family":"Leipsic","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philipp","family":"Blanke","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David A.","family":"Wood","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stephanie L.","family":"Sellers","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John G.","family":"Webb","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Janarthanan","family":"Sathananthan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,10,10]]},"reference":[{"key":"1959_CR1","first-page":"e35","volume":"143","author":"CM Otto","year":"2021","unstructured":"Otto CM, Nishimura RA, Bonow RO, et al. 2020 ACC\/AHA guideline for the management of patients with valvular heart disease: executive summary: a report of the American College of Cardiology\/American Heart Association Joint Committee on Clinical Practice Guidelines. Circulation. 2021;143:e35\u201371.","journal-title":"Circulation"},{"key":"1959_CR2","doi-asserted-by":"crossref","first-page":"524","DOI":"10.1016\/j.recesp.2021.11.023","volume":"75","author":"A Vahanian","year":"2022","unstructured":"Vahanian A, Beyersdorf F, Praz F, et al. 2021 ESC\/EACTS guidelines for the management of valvular heart disease: developed by the Task Force for the management of valvular heart disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS). Rev Esp Cardiol (Engl Ed). 2022;75:524.","journal-title":"Rev Esp Cardiol (Engl Ed)"},{"key":"1959_CR3","doi-asserted-by":"publisher","first-page":"1696","DOI":"10.1056\/NEJMoa1202277","volume":"366","author":"RR Makkar","year":"2012","unstructured":"Makkar RR, Fontana GP, Jilaihawi H, et al. Transcatheter aortic-valve replacement for inoperable severe aortic stenosis. N Engl J Med. 2012;366:1696\u2013704.","journal-title":"N Engl J Med"},{"key":"1959_CR4","doi-asserted-by":"publisher","first-page":"799","DOI":"10.1056\/NEJMoa1910555","volume":"382","author":"RR Makkar","year":"2020","unstructured":"Makkar RR, Thourani VH, Mack MJ, et al. Five-year outcomes of transcatheter or surgical aortic-valve replacement. N Engl J Med. 2020;382:799\u2013809.","journal-title":"N Engl J Med"},{"key":"1959_CR5","doi-asserted-by":"crossref","unstructured":"Barbanti M, Webb JG, Tamburino C, et al. Outcomes of redo transcatheter aortic valve replacement for the treatment of postprocedural and late occurrence of paravalvular regurgitation and transcatheter valve failure. Circ Cardiovasc Interv. 2016;9.","DOI":"10.1161\/CIRCINTERVENTIONS.116.003930"},{"key":"1959_CR6","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.120.010440","volume":"14","author":"L Testa","year":"2021","unstructured":"Testa L, Agnifili M, Van Mieghem NM, et al. Transcatheter aortic valve replacement for degenerated transcatheter aortic valves: the TRANSIT international project. Circ Cardiovasc Interv. 2021;14: e010440.","journal-title":"Circ Cardiovasc Interv"},{"key":"1959_CR7","doi-asserted-by":"publisher","first-page":"1882","DOI":"10.1016\/j.jacc.2020.02.051","volume":"75","author":"U Landes","year":"2020","unstructured":"\u2022 Landes U, Webb JG, De Backer O, et al. Repeat transcatheter aortic valve replacement for transcatheter prosthesis dysfunction. J Am Coll Cardiol. 2020;75:1882\u201393.\u00a0Important multicentric registry showing frequency and outcomes of redo-TAVR procedures.","journal-title":"J Am Coll Cardiol"},{"key":"1959_CR8","doi-asserted-by":"publisher","first-page":"1717","DOI":"10.1016\/j.jcin.2021.06.011","volume":"14","author":"ED Percy","year":"2021","unstructured":"Percy ED, Harloff MT, Hirji S, et al. Nationally representative repeat transcatheter aortic valve replacement outcomes: report from the centers for medicare and medicaid services. JACC Cardiovasc Interv. 2021;14:1717\u201326.","journal-title":"JACC Cardiovasc Interv"},{"issue":"539\u2013547","key":"1959_CR9","volume":"162","author":"S Fukuhara","year":"2021","unstructured":"Fukuhara S, Brescia AA, Shiomi S, et al. Surgical explantation of transcatheter aortic bioprostheses: results and clinical implications. J Thorac Cardiovasc Surg. 2021;162(539\u2013547): e1.","journal-title":"J Thorac Cardiovasc Surg"},{"key":"1959_CR10","doi-asserted-by":"publisher","first-page":"2083","DOI":"10.1007\/s00380-022-02119-7","volume":"37","author":"A Muensterer","year":"2022","unstructured":"Muensterer A, Puluca N, Ruge H, Vitanova K, Lange R. Surgical explantation of failed transcatheter heart valves: indications and results. Heart Vessels. 2022;37:2083\u201392.","journal-title":"Heart Vessels"},{"key":"1959_CR11","doi-asserted-by":"publisher","first-page":"927","DOI":"10.1016\/j.jcin.2023.01.376","volume":"16","author":"GHL Tang","year":"2023","unstructured":"\u2022 Tang GHL, Zaid S, Kleiman NS, et al. Explant vs redo-TAVR after transcatheter valve failure: mid-term outcomes from the EXPLANTORREDO-TAVR international registry. JACC Cardiovasc Interv. 2023;16:927\u201341.\u00a0Large registry on outcomes of patients undergoing redo-TAVR versus TAVR explant.","journal-title":"JACC Cardiovasc Interv"},{"key":"1959_CR12","doi-asserted-by":"publisher","DOI":"10.1161\/JAHA.120.019588","volume":"10","author":"MN Young","year":"2021","unstructured":"Young MN, Kearing S, Malenka D, Goodney PP, Skinner J, Iribarne A. Geographic and demographic variability in transcatheter aortic valve replacement dispersion in the United States. J Am Heart Assoc. 2021;10: e019588.","journal-title":"J Am Heart Assoc"},{"key":"1959_CR13","doi-asserted-by":"publisher","first-page":"2054","DOI":"10.1016\/j.jacc.2022.08.787","volume":"80","author":"T Sharma","year":"2022","unstructured":"Sharma T, Krishnan AM, Lahoud R, Polomsky M, Dauerman HL. National trends in TAVR and SAVR for patients with severe isolated aortic stenosis. J Am Coll Cardiol. 2022;80:2054\u20136.","journal-title":"J Am Coll Cardiol"},{"key":"1959_CR14","doi-asserted-by":"publisher","first-page":"1391","DOI":"10.1016\/j.jcin.2022.04.038","volume":"15","author":"M Vanhaverbeke","year":"2022","unstructured":"Vanhaverbeke M, Nuyens P, Baekke PS, et al. Temporal trends in survival rates after transcatheter aortic valve replacement. JACC Cardiovasc Interv. 2022;15:1391\u20133.","journal-title":"JACC Cardiovasc Interv"},{"key":"1959_CR15","doi-asserted-by":"publisher","first-page":"1978","DOI":"10.1016\/j.jcin.2021.07.015","volume":"14","author":"VN Bapat","year":"2021","unstructured":"Bapat VN, Zaid S, Fukuhara S, et al. Surgical explantation after TAVR failure: mid-term outcomes from the EXPLANT-TAVR international registry. JACC Cardiovasc Interv. 2021;14:1978\u201391.","journal-title":"JACC Cardiovasc Interv"},{"key":"1959_CR16","doi-asserted-by":"publisher","first-page":"1543","DOI":"10.1016\/j.jcin.2022.05.016","volume":"15","author":"U Landes","year":"2022","unstructured":"Landes U, Richter I, Danenberg H, et al. Outcomes of redo transcatheter aortic valve replacement according to the initial and subsequent valve type. JACC Cardiovasc Interv. 2022;15:1543\u201354.","journal-title":"JACC Cardiovasc Interv"},{"key":"1959_CR17","doi-asserted-by":"publisher","first-page":"480","DOI":"10.1161\/CIRCULATIONAHA.121.058339","volume":"146","author":"M Fukui","year":"2022","unstructured":"\u2022\u2022 Fukui M, Bapat VN, Garcia S, et al. Deformation of transcatheter aortic valve prostheses: implications for hypoattenuating leaflet thickening and clinical outcomes. Circulation. 2022;146:480\u201393.\u00a0This study shows the link between THV deformation and HALT as well as its association with adverse clinical outcomes.","journal-title":"Circulation"},{"key":"1959_CR18","doi-asserted-by":"crossref","unstructured":"Meier D, Landes U, Sondergaard L, et al. Redo-TAVI with SAPIEN 3 in SAPIEN XT and SAPIEN 3 \u2013 impact of pre- and post-dilatation on final THV expansion. EuroIntervention. 2023 (in press).","DOI":"10.4244\/EIJ-D-23-00308"},{"key":"1959_CR19","doi-asserted-by":"publisher","first-page":"368","DOI":"10.1016\/j.jcin.2021.12.021","volume":"15","author":"M Akodad","year":"2022","unstructured":"Akodad M, Sellers S, Landes U, et al. Balloon-expandable valve for treatment of evolut valve failure: implications on neoskirt height and leaflet overhang. JACC Cardiovasc Interv. 2022;15:368\u201377.","journal-title":"JACC Cardiovasc Interv"},{"key":"1959_CR20","doi-asserted-by":"crossref","unstructured":"Akodad M, Meier D, Sellers S, et al. A bench study of balloon-expandable valves for the treatment of self-expanding valve failure. EuroIntervention. 2023.","DOI":"10.4244\/EIJ-D-22-00769"},{"key":"1959_CR21","doi-asserted-by":"publisher","first-page":"1519","DOI":"10.1016\/j.jcin.2022.05.005","volume":"15","author":"D Meier","year":"2022","unstructured":"Meier D, Akodad M, Landes U, et al. Coronary access following redo TAVR: impact of THV design, implant technique, and cell misalignment. JACC Cardiovasc Interv. 2022;15:1519\u201331.","journal-title":"JACC Cardiovasc Interv"},{"key":"1959_CR22","doi-asserted-by":"publisher","first-page":"2298","DOI":"10.1016\/j.jcin.2021.07.034","volume":"14","author":"M Akodad","year":"2021","unstructured":"Akodad M, Sellers S, Gulsin GS, et al. Leaflet and neoskirt height in transcatheter heart valves: implications for repeat procedures and coronary access. JACC Cardiovasc Interv. 2021;14:2298\u2013300.","journal-title":"JACC Cardiovasc Interv"},{"key":"1959_CR23","doi-asserted-by":"publisher","first-page":"687","DOI":"10.1093\/eurheartj\/ehx455","volume":"39","author":"HB Ribeiro","year":"2018","unstructured":"Ribeiro HB, Rodes-Cabau J, Blanke P, et al. Incidence, predictors, and clinical outcomes of coronary obstruction following transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves: insights from the VIVID registry. Eur Heart J. 2018;39:687\u201395.","journal-title":"Eur Heart J"},{"key":"1959_CR24","doi-asserted-by":"publisher","first-page":"1497","DOI":"10.1016\/j.jcin.2022.06.001","volume":"15","author":"GHL Tang","year":"2022","unstructured":"Tang GHL, Amat-Santos IJ, De Backer O, et al. Rationale, definitions, techniques, and outcomes of commissural alignment in TAVR: from the ALIGN-TAVR consortium. JACC Cardiovasc Interv. 2022;15:1497\u2013518.","journal-title":"JACC Cardiovasc Interv"},{"key":"1959_CR25","doi-asserted-by":"publisher","first-page":"1154556","DOI":"10.3389\/fcvm.2023.1154556","volume":"10","author":"M Akodad","year":"2023","unstructured":"Akodad M, Lounes Y, Meier D, et al. Transcatheter heart valve commissural alignment: an updated review. Front Cardiovasc Med. 2023;10:1154556.","journal-title":"Front Cardiovasc Med"},{"key":"1959_CR26","doi-asserted-by":"publisher","first-page":"1733","DOI":"10.1016\/j.jcin.2018.05.043","volume":"11","author":"A Fuchs","year":"2018","unstructured":"Fuchs A, Kofoed KF, Yoon SH, et al. Commissural alignment of bioprosthetic aortic valve and native aortic valve following surgical and transcatheter aortic valve replacement and its impact on valvular function and coronary filling. JACC Cardiovasc Interv. 2018;11:1733\u201343.","journal-title":"JACC Cardiovasc Interv"},{"key":"1959_CR27","doi-asserted-by":"crossref","unstructured":"Abdel-Wahab M, Richter I, Taramasso M, et al. Procedural and one-year outcomes of the BASILICA technique in Europe: the multicentre EURO-BASILICA registry. EuroIntervention. 2023.","DOI":"10.4244\/EIJ-D-22-00960"},{"key":"1959_CR28","doi-asserted-by":"publisher","first-page":"941","DOI":"10.1016\/j.jcin.2021.02.035","volume":"14","author":"JM Khan","year":"2021","unstructured":"Khan JM, Babaliaros VC, Greenbaum AB, et al. Preventing coronary obstruction during transcatheter aortic valve replacement: results from the multicenter international BASILICA registry. JACC Cardiovasc Interv. 2021;14:941\u20138.","journal-title":"JACC Cardiovasc Interv"},{"key":"1959_CR29","doi-asserted-by":"publisher","first-page":"787","DOI":"10.1016\/j.jcin.2019.10.010","volume":"13","author":"JM Khan","year":"2020","unstructured":"Khan JM, Bruce CG, Babaliaros VC, Greenbaum AB, Rogers T, Lederman RJ. TAVR roulette: caution regarding BASILICA laceration for TAVR-in-TAVR. JACC Cardiovasc Interv. 2020;13:787\u20139.","journal-title":"JACC Cardiovasc Interv"},{"key":"1959_CR30","doi-asserted-by":"publisher","first-page":"578","DOI":"10.1016\/j.jcin.2020.10.056","volume":"14","author":"AB Greenbaum","year":"2021","unstructured":"Greenbaum AB, Kamioka N, Vavalle JP, et al. Balloon-assisted BASILICA to facilitate redo TAVR. JACC Cardiovasc Interv. 2021;14:578\u201380.","journal-title":"JACC Cardiovasc Interv"},{"key":"1959_CR31","doi-asserted-by":"publisher","first-page":"1431","DOI":"10.1016\/j.jcin.2023.04.031","volume":"16","author":"A Beneduce","year":"2023","unstructured":"Beneduce A, Khokhar AA, Curio J, et al. Comparison of BASILICA and balloon-assisted BASILICA coronary protection for redo-TAVR: insights from bench testing. JACC Cardiovasc Interv. 2023;16:1431\u20133.","journal-title":"JACC Cardiovasc Interv"},{"key":"1959_CR32","doi-asserted-by":"publisher","first-page":"e407","DOI":"10.4244\/EIJ-D-21-01091","volume":"18","author":"GA Medranda","year":"2022","unstructured":"Medranda GA, Soria Jimenez CE, Torguson R, et al. Lifetime management of patients with symptomatic severe aortic stenosis: a computed tomography simulation study. EuroIntervention. 2022;18:e407\u201316.","journal-title":"EuroIntervention"},{"key":"1959_CR33","doi-asserted-by":"publisher","first-page":"2617","DOI":"10.1016\/j.jcin.2020.09.022","volume":"13","author":"T Ochiai","year":"2020","unstructured":"Ochiai T, Oakley L, Sekhon N, et al. Risk of coronary obstruction due to sinus sequestration in redo transcatheter aortic valve replacement. JACC Cardiovasc Interv. 2020;13:2617\u201327.","journal-title":"JACC Cardiovasc Interv"},{"key":"1959_CR34","doi-asserted-by":"crossref","unstructured":"Grubb KJ, Shekiladze N, Spencer J, et al. Feasibility of redo-TAVI in self-expanding Evolut valves: a CT analysis from the Evolut Low Risk Trial substudy. EuroIntervention. 2023.","DOI":"10.4244\/EIJ-D-22-01125"},{"key":"1959_CR35","doi-asserted-by":"crossref","unstructured":"Tarantini G, Delgado V, de Backer O, et al. Redo-transcatheter aortic valve implantation using the SAPIEN 3\/ultra transcatheter heart valves-expert consensus on procedural planning and techniques. Am J Cardiol. 2023.","DOI":"10.1016\/j.amjcard.2023.01.010"},{"key":"1959_CR36","doi-asserted-by":"publisher","first-page":"1777","DOI":"10.1016\/j.jcin.2022.07.035","volume":"15","author":"G Tarantini","year":"2022","unstructured":"Tarantini G, Sathananthan J, Fabris T, et al. Transcatheter aortic valve replacement in failed transcatheter bioprosthetic valves. JACC Cardiovasc Interv. 2022;15:1777\u201393.","journal-title":"JACC Cardiovasc Interv"}],"container-title":["Current Cardiology Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11886-023-01959-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11886-023-01959-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11886-023-01959-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,28]],"date-time":"2023-11-28T03:18:10Z","timestamp":1701141490000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11886-023-01959-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10,10]]},"references-count":36,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2023,11]]}},"alternative-id":["1959"],"URL":"https:\/\/doi.org\/10.1007\/s11886-023-01959-7","relation":{},"ISSN":["1523-3782","1534-3170"],"issn-type":[{"type":"print","value":"1523-3782"},{"type":"electronic","value":"1534-3170"}],"subject":[],"published":{"date-parts":[[2023,10,10]]},"assertion":[{"value":"6 September 2023","order":1,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 October 2023","order":2,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with Ethical Standards"}},{"value":"D. Meier has received an institutional grant from Edwards Lifesciences. M. Akodad is a consultant to Edwards Lifesciences and Medtronic. J. Leipsic has received an unrestricted research grant from GE Healthcare; holds stock options in and has received consulting fees from HeartFlow and Circle CVI; and has received speaker fees from GE and Philips. P. Blanke provides institutional CT core laboratory services to Edwards Lifesciences, Medtronic, Boston Scientific, Abbott Laboratories, PiCardia, and Neovasc without direct personal reimbursements, and is a consultant to Edwards Lifesciences. J D. Wood is a consultant and has received unrestricted grant support from Edwards Lifesciences, Medtronic, Abbott, and Boston Scientific. S. Sellers is a consultant to Anteris, Medtronic, Edwards Lifesciences, and Excision Medical. She has received research support from Vivtro Labs, Heartflow, Edwards Lifesciences, and Medtronic. J. Webb is a consultant to Edwards Lifesciences. He has received research funding from Edwards Lifesciences, Medtronic, Boston Scientific, and Abbott. J. Sathananthan is a consultant to Edwards Lifesciences, Medtronic, Anteris, and Boston Scientific. He has received research support from Edwards Lifesciences and Medtronic. The other authors have nothing to disclose.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"<!--Emphasis Type='Bold' removed-->Conflict of Interest"}},{"value":"This article does not contain any studies with human or animal subjects performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Human and Animal Rights and Informed Consent"}}]}}