{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T00:24:02Z","timestamp":1789086242915,"version":"build-2803163510"},"reference-count":125,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2024,8,20]],"date-time":"2024-08-20T00:00:00Z","timestamp":1724112000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,8,20]],"date-time":"2024-08-20T00:00:00Z","timestamp":1724112000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Herzzentrum G\u00f6ttingen"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Curr Cardiol Rep"],"published-print":{"date-parts":[[2024,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose of the Review<\/jats:title>\n                <jats:p>This review aims to provide a profound overview on most recent studies on the clinical significance of Cardiovascular Computed Tomography (CCT) in diagnostic and therapeutic pathways. Herby, this review helps to pave the way for a more extended but yet purposefully use in modern day cardiovascular medicine.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Recent Findings<\/jats:title>\n                <jats:p>In recent years, new clinical applications of  CCT have emerged. Major applications include the assessment of coronary artery disease and structural heart disease, with corresponding recommendations by major guidelines of international societies. While CCT already allows for a rapid and non-invasive diagnosis, technical improvements enable further in-depth assessments using novel imaging parameters with high temporal and spatial resolution. Those developments facilitate diagnostic and therapeutic decision-making as well as improved prognostication.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Summary<\/jats:title>\n                <jats:p>This review determined that recent advancements in both hardware and software components of CCT allow for highly advanced examinations with little radiation exposure. This particularly strengthens its role in preventive care and coronary artery disease. The addition of functional analyses within and beyond coronary artery disease offers solutions in wide-ranging patient populations. Many techniques still require improvement and validation, however, CCT possesses potential to become a \u201cone-stop-shop\u201d examination.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s11886-024-02110-w","type":"journal-article","created":{"date-parts":[[2024,8,20]],"date-time":"2024-08-20T12:02:22Z","timestamp":1724155342000},"page":"1063-1076","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Clinical Advances in Cardiovascular Computed Tomography: From Present Applications to Promising Developments"],"prefix":"10.1007","volume":"26","author":[{"given":"Alexander","family":"Schulz","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James","family":"Otton","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tarique","family":"Hussain","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tayaba","family":"Miah","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andreas","family":"Schuster","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,8,20]]},"reference":[{"key":"2110_CR1","doi-asserted-by":"publisher","first-page":"2018","DOI":"10.21037\/cdt-20-527","volume":"10","author":"P Toia","year":"2020","unstructured":"Toia P, et al. Technical development in cardiac CT: current standards and future improvements\u2014a narrative review. Cardiovasc Diagn Ther. 2020;10:2018\u201335.","journal-title":"Cardiovasc Diagn Ther"},{"key":"2110_CR2","doi-asserted-by":"publisher","first-page":"e187","DOI":"10.1016\/j.jacc.2021.07.053","volume":"78","author":"M Gulati","year":"2021","unstructured":"Gulati M, et al. 2021 AHA\/ACC\/ASE\/CHEST\/SAEM\/SCCT\/SCMR Guideline for the Evaluation and Diagnosis of Chest Pain: A Report of the American College of Cardiology\/American Heart Association Joint Committee on Clinical Practice Guidelines. J Am Coll Cardiol. 2021;78:e187\u2013285.","journal-title":"J Am Coll Cardiol"},{"key":"2110_CR3","doi-asserted-by":"publisher","first-page":"1397","DOI":"10.1056\/NEJMoa1816897","volume":"380","author":"JS Lemkes","year":"2019","unstructured":"Lemkes JS, et al. Coronary Angiography after Cardiac Arrest without ST-Segment Elevation. N Engl J Med. 2019;380:1397\u2013407.","journal-title":"N Engl J Med"},{"key":"2110_CR4","doi-asserted-by":"publisher","first-page":"2544","DOI":"10.1056\/NEJMoa2101909","volume":"385","author":"S Desch","year":"2021","unstructured":"Desch S, et al. Angiography after Out-of-Hospital Cardiac Arrest without ST-Segment Elevation. N Engl J Med. 2021;385:2544\u201353.","journal-title":"N Engl J Med"},{"key":"2110_CR5","doi-asserted-by":"publisher","first-page":"3997","DOI":"10.1093\/eurheartj\/ehac262","volume":"43","author":"K Zeppenfeld","year":"2022","unstructured":"Zeppenfeld K, et al. 2022 ESC Guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: Developed by the task force for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death of the European Society of Cardiology (ESC) Endorsed by the Association for European Paediatric and Congenital Cardiology (AEPC). Eur Heart J. 2022;43:3997\u20134126.","journal-title":"Eur Heart J"},{"key":"2110_CR6","doi-asserted-by":"publisher","unstructured":"Schmidt B, Grant K, Flohr TG, Allmendinger T. Cardiac CT Platforms: State of the Art. in CT of the Heart (ed. Schoepf, U. J.) 51\u201367 (Humana Press, 2019). https:\/\/doi.org\/10.1007\/978-1-60327-237-7_6","DOI":"10.1007\/978-1-60327-237-7_6"},{"key":"2110_CR7","doi-asserted-by":"publisher","unstructured":"Ohnesorge, B. Future Technical Developments in Cardiac CT. in Multi-slice and Dual-source CT in Cardiac Imaging: Principles \u2014 Protocols \u2014 Indications \u2014 Outlook (eds. Ohnesorge, B. M., Flohr, T. G., Becker, C. R., Knez, A. & Reiser, M. F.) 327\u2013358 (Springer, 2007). https:\/\/doi.org\/10.1007\/978-3-540-49546-8_22","DOI":"10.1007\/978-3-540-49546-8_22"},{"key":"2110_CR8","doi-asserted-by":"publisher","first-page":"362","DOI":"10.1016\/j.ejrad.2008.08.013","volume":"68","author":"M Petersilka","year":"2008","unstructured":"Petersilka M, Bruder H, Krauss B, Stierstorfer K, Flohr TG. Technical principles of dual source CT. Eur J Radiol. 2008;68:362\u20138.","journal-title":"Eur J Radiol"},{"key":"2110_CR9","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1016\/j.jcct.2009.07.003","volume":"3","author":"E Lin","year":"2009","unstructured":"Lin E, Alessio A. What are the basic concepts of temporal, contrast, and spatial resolution in cardiac CT? J Cardiovasc Comput Tomogr. 2009;3:403\u20138.","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"2110_CR10","doi-asserted-by":"publisher","first-page":"665","DOI":"10.1016\/j.ccl.2009.06.006","volume":"27","author":"TC Gerber","year":"2009","unstructured":"Gerber TC, Kantor B, McCollough CH. Radiation Dose and Safety in Cardiac Computed Tomography. Cardiol Clin. 2009;27:665\u201377.","journal-title":"Cardiol Clin"},{"key":"2110_CR11","doi-asserted-by":"publisher","first-page":"981","DOI":"10.1016\/j.repc.2013.05.005","volume":"32","author":"P de Ara\u00fajoGon\u00e7alves","year":"2013","unstructured":"de Ara\u00fajoGon\u00e7alves P, et al. Effective radiation dose of three diagnostic tests in cardiology: Single photon emission computed tomography, invasive coronary angiography and cardiac computed tomography angiography. Rev Port Cardiol Engl Ed. 2013;32:981\u20136.","journal-title":"Rev Port Cardiol Engl Ed"},{"key":"2110_CR12","doi-asserted-by":"publisher","first-page":"278","DOI":"10.1016\/j.jcct.2015.03.001","volume":"9","author":"S Deseive","year":"2015","unstructured":"Deseive S, et al. Image quality and radiation dose of a prospectively electrocardiography-triggered high-pitch data acquisition strategy for coronary CT angiography: The multicenter, randomized PROTECTION IV study. J Cardiovasc Comput Tomogr. 2015;9:278\u201385.","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"2110_CR13","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1016\/j.acra.2014.07.025","volume":"22","author":"M Zheng","year":"2015","unstructured":"Zheng M, et al. Low-Concentration Contrast Medium for 128-Slice Dual-Source CT Coronary Angiography at a Very Low Radiation Dose Using Prospectively ECG-Triggered High-Pitch Spiral Acquisition. Acad Radiol. 2015;22:195\u2013202.","journal-title":"Acad Radiol"},{"key":"2110_CR14","doi-asserted-by":"publisher","first-page":"2227","DOI":"10.1007\/s10554-022-02615-x","volume":"38","author":"FA Bechtiger","year":"2022","unstructured":"Bechtiger FA, et al. Risk stratification using coronary artery calcium scoring based on low tube voltage computed tomography. Int J Cardiovasc Imaging. 2022;38:2227\u201334.","journal-title":"Int J Cardiovasc Imaging"},{"key":"2110_CR15","doi-asserted-by":"publisher","first-page":"358","DOI":"10.1093\/ehjci\/jeu218","volume":"16","author":"HS Hecht","year":"2016","unstructured":"Hecht HS, et al. Low- vs. standard-dose coronary artery calcium scanning. Eur Heart J Cardiovasc Imaging. 2016;16:358\u201363.","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"2110_CR16","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1186\/s40064-015-0866-1","volume":"4","author":"D Utsunomiya","year":"2015","unstructured":"Utsunomiya D, et al. Evaluation of appropriateness of second-generation 320-row computed tomography for coronary artery disease. Springerplus. 2015;4:109.","journal-title":"Springerplus"},{"key":"2110_CR17","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.13122621","author":"MY Chen","year":"2013","unstructured":"Chen MY, Shanbhag SM, Arai AE. Submillisievert Median Radiation Dose for Coronary Angiography with a Second-Generation 320\u2013Detector Row CT Scanner in 107 Consecutive Patients. Radiology. 2013. https:\/\/doi.org\/10.1148\/radiol.13122621.","journal-title":"Radiology"},{"key":"2110_CR18","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1148\/radiol.2020192791","volume":"298","author":"AC Kwan","year":"2021","unstructured":"Kwan AC, Pourmorteza A, Stutman D, Bluemke DA, Lima JAC. Next-Generation Hardware Advances in CT: Cardiac Applications. Radiology. 2021;298:3\u201317.","journal-title":"Radiology"},{"key":"2110_CR19","doi-asserted-by":"crossref","unstructured":"Meinel FG, Renker M (2019) Coronary CT angiography for screening, risk stratification, and management of asymptomatic patients: state of the evidence in Schoepf, U. J. Contemporary medical imaging. CT of the Heart: Second Edition. Humana Totowa, 2019 pp 739-745. https:\/\/doi.org\/10.1007\/978-1-60327-237-7_58","DOI":"10.1007\/978-1-60327-237-7_58"},{"key":"2110_CR20","doi-asserted-by":"crossref","unstructured":"Flohr T, Ohnesorge B (2007) Multi-slice CT technology. In: Ohnesorge B, Flohr T, Becker CR, Knez A, Reiser MF (eds) Multi-slice and dual-source CT in cardiac imaging. Principles \u2013 Protocols \u2013 Indications \u2013 Outlook, 2nd edn. Springer, Berlin, pp 41\u201369","DOI":"10.1007\/978-3-540-49546-8_3"},{"key":"2110_CR21","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1016\/j.jcct.2009.04.004","volume":"3","author":"TG Flohr","year":"2009","unstructured":"Flohr TG, Raupach R, Bruder H. Cardiac CT: how much can temporal resolution, spatial resolution, and volume coverage be improved? J Cardiovasc Comput Tomogr. 2009;3:143\u201352.","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"2110_CR22","doi-asserted-by":"publisher","first-page":"869","DOI":"10.1016\/j.acra.2017.11.017","volume":"25","author":"A Hata","year":"2018","unstructured":"Hata A, et al. Effect of Matrix Size on the Image Quality of Ultra-high-resolution CT of the Lung: Comparison of 512 \u00d7 512, 1024 \u00d7 1024, and 2048 \u00d7 2048. Acad Radiol. 2018;25:869\u201376.","journal-title":"Acad Radiol"},{"key":"2110_CR23","first-page":"1844","volume":"82","author":"S Motoyama","year":"2018","unstructured":"Motoyama S, et al. Ultra-High-Resolution Computed Tomography Angiography for Assessment of Coronary Artery Stenosis. Circ J Off J Jpn Circ Soc. 2018;82:1844\u201351.","journal-title":"Circ J Off J Jpn Circ Soc"},{"key":"2110_CR24","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1016\/j.ejrad.2018.01.030","volume":"101","author":"H Takagi","year":"2018","unstructured":"Takagi H, et al. Diagnostic performance of coronary CT angiography with ultra-high-resolution CT: Comparison with invasive coronary angiography. Eur J Radiol. 2018;101:30\u20137.","journal-title":"Eur J Radiol"},{"key":"2110_CR25","doi-asserted-by":"publisher","first-page":"115","DOI":"10.2967\/jnmt.107.042978","volume":"35","author":"LW Goldman","year":"2007","unstructured":"Goldman LW. Principles of CT and CT technology. J Nucl Med Technol. 2007;35:115\u201328.","journal-title":"J Nucl Med Technol"},{"key":"2110_CR26","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1016\/j.jcct.2012.04.005","volume":"6","author":"S Halliburton","year":"2012","unstructured":"Halliburton S, et al. State-of-the-art in CT hardware and scan modes for cardiovascular CT. J Cardiovasc Comput Tomogr. 2012;6:154\u201363.","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"2110_CR27","first-page":"2064","volume":"36","author":"K Kalisz","year":"2016","unstructured":"Kalisz K, et al. Artifacts at Cardiac CT: Physics and Solutions. Radiogr Rev Publ Radiol Soc N Am Inc. 2016;36:2064\u201383.","journal-title":"Radiogr Rev Publ Radiol Soc N Am Inc"},{"key":"2110_CR28","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1016\/j.rcl.2010.02.006","volume":"48","author":"KK Kumamaru","year":"2010","unstructured":"Kumamaru KK, Hoppel BE, Mather RT, Rybicki FJ. CT Angiography: Current Technology and Clinical Use. Radiol Clin North Am. 2010;48:213\u201335.","journal-title":"Radiol Clin North Am"},{"key":"2110_CR29","doi-asserted-by":"publisher","first-page":"1623","DOI":"10.1007\/s00330-012-2765-y","volume":"23","author":"MJ Willemink","year":"2013","unstructured":"Willemink MJ, et al. Iterative reconstruction techniques for computed tomography Part 1: technical principles. Eur Radiol. 2013;23:1623\u201331.","journal-title":"Eur Radiol"},{"key":"2110_CR30","doi-asserted-by":"publisher","first-page":"527","DOI":"10.21037\/cdt.2017.08.12","volume":"7","author":"SS Halliburton","year":"2017","unstructured":"Halliburton SS, Tanabe Y, Partovi S, Rajiah P. The role of advanced reconstruction algorithms in cardiac CT. Cardiovasc Diagn Ther. 2017;7:527\u201338.","journal-title":"Cardiovasc Diagn Ther"},{"key":"2110_CR31","doi-asserted-by":"publisher","first-page":"3141","DOI":"10.1016\/j.ejrad.2012.04.012","volume":"81","author":"R Wang","year":"2012","unstructured":"Wang R, et al. Image quality and radiation dose of low dose coronary CT angiography in obese patients: sinogram affirmed iterative reconstruction versus filtered back projection. Eur J Radiol. 2012;81:3141\u20135.","journal-title":"Eur J Radiol"},{"key":"2110_CR32","doi-asserted-by":"publisher","first-page":"1262","DOI":"10.1161\/01.ATV.20.5.1262","volume":"20","author":"R Virmani","year":"2000","unstructured":"Virmani R, Kolodgie FD, Burke AP, Farb A, Schwartz SM. Lessons from sudden coronary death: a comprehensive morphological classification scheme for atherosclerotic lesions. Arterioscler Thromb Vasc Biol. 2000;20:1262\u201375.","journal-title":"Arterioscler Thromb Vasc Biol"},{"key":"2110_CR33","doi-asserted-by":"publisher","first-page":"1016","DOI":"10.1259\/0007-1285-46-552-1016","volume":"46","author":"GN Hounsfield","year":"1973","unstructured":"Hounsfield GN. Computerized transverse axial scanning (tomography) Description of system. Br J Radiol. 1973;46:1016\u201322.","journal-title":"Br J Radiol"},{"key":"2110_CR34","unstructured":"Commissioner, O. of the. FDA Clears First Major Imaging Device Advancement for Computed Tomography in Nearly a Decade. FDA https:\/\/www.fda.gov\/news-events\/press-announcements\/fda-clears-first-major-imaging-device-advancement-computed-tomography-nearly-decade (2021)."},{"key":"2110_CR35","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1148\/radiol.2018172656","volume":"289","author":"MJ Willemink","year":"2018","unstructured":"Willemink MJ, Persson M, Pourmorteza A, Pelc NJ, Fleischmann D. Photon-counting CT: Technical Principles and Clinical Prospects. Radiology. 2018;289:293\u2013312.","journal-title":"Radiology"},{"key":"2110_CR36","doi-asserted-by":"publisher","first-page":"100901","DOI":"10.1118\/1.4820371","volume":"40","author":"K Taguchi","year":"2013","unstructured":"Taguchi K, Iwanczyk JS. Vision 20\/20: Single photon counting x-ray detectors in medical imaging. Med Phys. 2013;40:100901.","journal-title":"Med Phys"},{"key":"2110_CR37","doi-asserted-by":"publisher","first-page":"733","DOI":"10.1088\/0031-9155\/21\/5\/002","volume":"21","author":"RE Alvarez","year":"1976","unstructured":"Alvarez RE, Macovski A. Energy-selective reconstructions in X-ray computerized tomography. Phys Med Biol. 1976;21:733\u201344.","journal-title":"Phys Med Biol"},{"key":"2110_CR38","doi-asserted-by":"publisher","first-page":"4679","DOI":"10.1088\/0031-9155\/52\/15\/020","volume":"52","author":"E Roessl","year":"2007","unstructured":"Roessl E, Proksa R. K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors. Phys Med Biol. 2007;52:4679\u201396.","journal-title":"Phys Med Biol"},{"key":"2110_CR39","doi-asserted-by":"publisher","first-page":"15367","DOI":"10.1038\/s41598-020-72417-5","volume":"10","author":"A Yamada","year":"2020","unstructured":"Yamada A, et al. Quantification of extracellular volume fraction by cardiac computed tomography for noninvasive assessment of myocardial fibrosis in hemodialysis patients. Sci Rep. 2020;10:15367.","journal-title":"Sci Rep"},{"key":"2110_CR40","doi-asserted-by":"publisher","first-page":"1655","DOI":"10.1016\/j.jacc.2006.01.041","volume":"47","author":"U Hoffmann","year":"2006","unstructured":"Hoffmann U, et al. Noninvasive assessment of plaque morphology and composition in culprit and stable lesions in acute coronary syndrome and stable lesions in stable angina by multidetector computed tomography. J Am Coll Cardiol. 2006;47:1655\u201362.","journal-title":"J Am Coll Cardiol"},{"key":"2110_CR41","doi-asserted-by":"publisher","first-page":"410","DOI":"10.1148\/radiol.12112363","volume":"265","author":"D Andreini","year":"2012","unstructured":"Andreini D, et al. Coronary In-Stent Restenosis: Assessment with CT Coronary Angiography. Radiology. 2012;265:410\u20137.","journal-title":"Radiology"},{"key":"2110_CR42","doi-asserted-by":"publisher","first-page":"1232","DOI":"10.1093\/eurheartj\/ehv700","volume":"37","author":"M Lubbers","year":"2016","unstructured":"Lubbers M, et al. Calcium imaging and selective computed tomography angiography in comparison to functional testing for suspected coronary artery disease: the multicentre, randomized CRESCENT trial. Eur Heart J. 2016;37:1232\u201343.","journal-title":"Eur Heart J"},{"key":"2110_CR43","doi-asserted-by":"publisher","first-page":"6193","DOI":"10.1007\/s00330-020-07677-w","volume":"31","author":"FG Gassert","year":"2021","unstructured":"Gassert FG, et al. Calcium scoring using virtual non-contrast images from a dual-layer spectral detector CT: comparison to true non-contrast data and evaluation of proportionality factor in a large patient collective. Eur Radiol. 2021;31:6193\u20139.","journal-title":"Eur Radiol"},{"key":"2110_CR44","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/j.jcct.2011.11.004","volume":"6","author":"JM Otton","year":"2012","unstructured":"Otton JM, et al. A method for coronary artery calcium scoring using contrast-enhanced computed tomography. J Cardiovasc Comput Tomogr. 2012;6:37\u201344.","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"2110_CR45","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1056\/NEJMoa0807611","volume":"360","author":"PAL Tonino","year":"2009","unstructured":"Tonino PAL, et al. Fractional Flow Reserve versus Angiography for Guiding Percutaneous Coronary Intervention. N Engl J Med. 2009;360:213\u201324.","journal-title":"N Engl J Med"},{"key":"2110_CR46","doi-asserted-by":"publisher","first-page":"1824","DOI":"10.1056\/NEJMoa1700445","volume":"376","author":"JE Davies","year":"2017","unstructured":"Davies JE, et al. Use of the Instantaneous Wave-free Ratio or Fractional Flow Reserve in PCI. N Engl J Med. 2017;376:1824\u201334.","journal-title":"N Engl J Med"},{"key":"2110_CR47","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1093\/eurheartj\/ehz425","volume":"41","author":"J Knuuti","year":"2020","unstructured":"Knuuti J, et al. 2019 ESC Guidelines for the diagnosis and management of chronic coronary syndromes: The Task Force for the diagnosis and management of chronic coronary syndromes of the European Society of Cardiology (ESC). Eur Heart J. 2020;41:407\u201377.","journal-title":"Eur Heart J"},{"key":"2110_CR48","doi-asserted-by":"publisher","first-page":"300","DOI":"10.1161\/CIRCRESAHA.116.307914","volume":"119","author":"HS Hecht","year":"2016","unstructured":"Hecht HS, Narula J, Fearon WF. Fractional Flow Reserve and Coronary Computed Tomographic Angiography. Circ Res. 2016;119:300\u201316.","journal-title":"Circ Res"},{"key":"2110_CR49","doi-asserted-by":"publisher","first-page":"11535","DOI":"10.1038\/s41598-018-29910-9","volume":"8","author":"P Agasthi","year":"2018","unstructured":"Agasthi P, et al. Comparison of Computed Tomography derived Fractional Flow Reserve to invasive Fractional Flow Reserve in Diagnosis of Functional Coronary Stenosis: A Meta-Analysis. Sci Rep. 2018;8:11535.","journal-title":"Sci Rep"},{"key":"2110_CR50","doi-asserted-by":"publisher","first-page":"340","DOI":"10.1148\/rg.210097","volume":"42","author":"P Rajiah","year":"2022","unstructured":"Rajiah P, Cummings KW, Williamson E, Young PM. CT Fractional Flow Reserve: A Practical Guide to Application, Interpretation, and Problem Solving. Radiographics. 2022;42:340\u201358.","journal-title":"Radiographics"},{"key":"2110_CR51","doi-asserted-by":"publisher","first-page":"550","DOI":"10.1253\/circj.69.550","volume":"69","author":"A Kurata","year":"2005","unstructured":"Kurata A, et al. Myocardial Perfusion Imaging Using Adenosine Triphosphate Stress Multi-Slice Spiral Computed Tomography Alternative to Stress Myocardial Perfusion Scintigraphy: Alternative to Stress Myocardial Perfusion Scintigraphy. Circ J. 2005;69:550\u20137.","journal-title":"Circ J"},{"key":"2110_CR52","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1016\/j.jacc.2006.04.014","volume":"48","author":"RT George","year":"2006","unstructured":"George RT, et al. Multidetector computed tomography myocardial perfusion imaging during adenosine stress. J Am Coll Cardiol. 2006;48:153\u201360.","journal-title":"J Am Coll Cardiol"},{"key":"2110_CR53","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1016\/j.jcct.2013.01.016","volume":"7","author":"J Otton","year":"2013","unstructured":"Otton J, et al. A direct comparison of the sensitivity of CT and MR cardiac perfusion using a myocardial perfusion phantom. J Cardiovasc Comput Tomogr. 2013;7:117\u201324.","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"2110_CR54","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1093\/eurheartj\/ehr268","volume":"33","author":"BS Ko","year":"2012","unstructured":"Ko BS, et al. Computed tomography stress myocardial perfusion imaging in patients considered for revascularization: a comparison with fractional flow reserve. Eur Heart J. 2012;33:67\u201377.","journal-title":"Eur Heart J"},{"key":"2110_CR55","doi-asserted-by":"publisher","first-page":"1099","DOI":"10.1016\/j.jacc.2012.12.020","volume":"61","author":"N Bettencourt","year":"2013","unstructured":"Bettencourt N, et al. Direct Comparison of Cardiac Magnetic Resonance and Multidetector Computed Tomography Stress-Rest Perfusion Imaging for Detection of Coronary Artery Disease. J Am Coll Cardiol. 2013;61:1099\u2013107.","journal-title":"J Am Coll Cardiol"},{"key":"2110_CR56","doi-asserted-by":"crossref","unstructured":"Bettencourt N, Ferreira ND, Leite D, Carvalho M, Ferreira WDS, Schuster A, et al. CAD detection in patients with intermediate-high pre-test probability: low-dose CT delayed enhancement detects ischemic myocardial scar with moderate accuracy but does not improve performance of a stress-rest CT perfusion protocol. JACC Cardiovasc Imaging. 2013;6:1062\u201371.","DOI":"10.1016\/j.jcmg.2013.04.013"},{"key":"2110_CR57","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1148\/radiol.2302030042","volume":"230","author":"KU Juergens","year":"2004","unstructured":"Juergens KU, et al. Multi-Detector Row CT of Left Ventricular Function with Dedicated Analysis Software versus MR Imaging: Initial Experience. Radiology. 2004;230:403\u201310.","journal-title":"Radiology"},{"key":"2110_CR58","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1161\/CIRCULATIONAHA.106.626143","volume":"114","author":"L Sugeng","year":"2006","unstructured":"Sugeng L, et al. Quantitative assessment of left ventricular size and function: side-by-side comparison of real-time three-dimensional echocardiography and computed tomography with magnetic resonance reference. Circulation. 2006;114:654\u201361.","journal-title":"Circulation"},{"key":"2110_CR59","doi-asserted-by":"publisher","first-page":"e757","DOI":"10.1016\/j.ejrad.2012.02.002","volume":"81","author":"C Asferg","year":"2012","unstructured":"Asferg C, Usinger L, Kristensen TS, Abdulla J. Accuracy of multi-slice computed tomography for measurement of left ventricular ejection fraction compared with cardiac magnetic resonance imaging and two-dimensional transthoracic echocardiography: A systematic review and meta-analysis. Eur J Radiol. 2012;81:e757\u201362.","journal-title":"Eur J Radiol"},{"key":"2110_CR60","doi-asserted-by":"publisher","first-page":"254","DOI":"10.1016\/j.ijcard.2008.10.031","volume":"139","author":"Y Guo","year":"2010","unstructured":"Guo Y, et al. Accuracy and reproducibility of assessing right ventricular function with 64-section multi-detector row CT: Comparison with magnetic resonance imaging. Int J Cardiol. 2010;139:254\u201362.","journal-title":"Int J Cardiol"},{"key":"2110_CR61","doi-asserted-by":"publisher","first-page":"372","DOI":"10.1016\/j.jcct.2018.05.002","volume":"12","author":"ER McVeigh","year":"2018","unstructured":"McVeigh ER, et al. Regional myocardial strain measurements from 4DCT in patients with normal LV function. J Cardiovasc Comput Tomogr. 2018;12:372\u20138.","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"2110_CR62","doi-asserted-by":"publisher","first-page":"109485","DOI":"10.1016\/j.ejrad.2020.109485","volume":"135","author":"R Wang","year":"2021","unstructured":"Wang R, et al. Quantitative analysis of three-dimensional left ventricular global strain using coronary computed tomography angiography in patients with heart failure: Comparison with 3T cardiac MR. Eur J Radiol. 2021;135:109485.","journal-title":"Eur J Radiol"},{"key":"2110_CR63","doi-asserted-by":"publisher","first-page":"1167","DOI":"10.1016\/j.jcmg.2009.05.014","volume":"2","author":"AH Mahnken","year":"2009","unstructured":"Mahnken AH, Bruners P, Bornikoel CM, Kr\u00e4mer N, Guenther RW. Assessment of Myocardial Edema by Computed Tomography in Myocardial Infarction. JACC Cardiovasc Imaging. 2009;2:1167\u201374.","journal-title":"JACC Cardiovasc Imaging"},{"key":"2110_CR64","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1016\/j.jcct.2018.10.011","volume":"13","author":"M van Assen","year":"2019","unstructured":"van Assen M, et al. Feasibility of extracellular volume quantification using dual-energy CT. J Cardiovasc Comput Tomogr. 2019;13:81\u20134.","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"2110_CR65","doi-asserted-by":"publisher","first-page":"876","DOI":"10.1148\/radiol.12112458","volume":"264","author":"MS Nacif","year":"2012","unstructured":"Nacif MS, et al. Interstitial myocardial fibrosis assessed as extracellular volume fraction with low-radiation-dose cardiac CT. Radiology. 2012;264:876\u201383.","journal-title":"Radiology"},{"key":"2110_CR66","doi-asserted-by":"publisher","first-page":"923","DOI":"10.1148\/radiol.11110617","volume":"261","author":"S Prevrhal","year":"2011","unstructured":"Prevrhal S, Forsythe CH, Harnish RJ, Saeed M, Yeh BM. CT angiographic measurement of vascular blood flow velocity by using projection data. Radiology. 2011;261:923\u20139.","journal-title":"Radiology"},{"key":"2110_CR67","doi-asserted-by":"crossref","unstructured":"Franke B et al. (2021) Computed Tomography-Based Assessment of Transvalvular Pressure Gradient in Aortic Stenosis. Front. Cardiovasc. Med. 8:706628. doi: 10.3389\/fcvm.2021.706628","DOI":"10.3389\/fcvm.2021.706628"},{"key":"2110_CR68","doi-asserted-by":"publisher","first-page":"1065","DOI":"10.1016\/j.jcp.2015.11.022","volume":"305","author":"R Mittal","year":"2016","unstructured":"Mittal R, et al. Computational modeling of cardiac hemodynamics: Current status and future outlook. J Comput Phys. 2016;305:1065\u201382.","journal-title":"J Comput Phys"},{"issue":"12","key":"2110_CR69","doi-asserted-by":"publisher","first-page":"121004","DOI":"10.1115\/1.4034652","volume":"138","author":"J Lantz","year":"2016","unstructured":"Lantz J, Henriksson L, Persson A, Karlsson M, Ebbers T. Patient-Specific Simulation of Cardiac Blood Flow From High-Resolution Computed Tomography. J Biomech Eng. 2016;138(12):121004.","journal-title":"J. Biomech Eng."},{"key":"2110_CR70","doi-asserted-by":"publisher","first-page":"916","DOI":"10.1161\/CIRCULATIONAHA.121.055340","volume":"144","author":"G Bergstr\u00f6m","year":"2021","unstructured":"Bergstr\u00f6m G, et al. Prevalence of Subclinical Coronary Artery Atherosclerosis in the General Population. Circulation. 2021;144:916\u201329.","journal-title":"Circulation"},{"key":"2110_CR71","doi-asserted-by":"publisher","first-page":"391","DOI":"10.1001\/jamacardio.2016.5493","volume":"2","author":"JJ Carr","year":"2017","unstructured":"Carr JJ, et al. Association of Coronary Artery Calcium in Adults Aged 32 to 46 Years With Incident Coronary Heart Disease and Death. JAMA Cardiol. 2017;2:391\u20139.","journal-title":"JAMA Cardiol"},{"key":"2110_CR72","first-page":"e596","volume":"140","author":"DK Arnett","year":"2019","unstructured":"Arnett DK, et al. 2019 ACC\/AHA Guideline on the Primary Prevention of Cardiovascular Disease: A Report of the American College of Cardiology\/American Heart Association Task Force on Clinical Practice Guidelines. Circulation. 2019;140:e596\u2013646.","journal-title":"Circulation"},{"key":"2110_CR73","doi-asserted-by":"publisher","first-page":"2511","DOI":"10.1016\/j.jacc.2018.02.079","volume":"71","author":"H-J Chang","year":"2018","unstructured":"Chang H-J, et al. Coronary Atherosclerotic Precursors of Acute Coronary Syndromes. J Am Coll Cardiol. 2018;71:2511\u201322.","journal-title":"J Am Coll Cardiol"},{"key":"2110_CR74","doi-asserted-by":"publisher","first-page":"510","DOI":"10.1016\/j.jacc.2010.11.078","volume":"58","author":"FY Lin","year":"2011","unstructured":"Lin FY, et al. Mortality Risk in Symptomatic Patients With Nonobstructive Coronary Artery Disease: A Prospective 2-Center Study of 2,583 Patients Undergoing 64-Detector Row Coronary Computed Tomographic Angiography. J Am Coll Cardiol. 2011;58:510\u20139.","journal-title":"J Am Coll Cardiol"},{"key":"2110_CR75","doi-asserted-by":"publisher","first-page":"1336","DOI":"10.1056\/NEJMoa072100","volume":"358","author":"R Detrano","year":"2008","unstructured":"Detrano R, et al. Coronary Calcium as a Predictor of Coronary Events in Four Racial or Ethnic Groups. N Engl J Med. 2008;358:1336\u201345.","journal-title":"N Engl J Med"},{"key":"2110_CR76","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1016\/j.jacc.2008.07.072","volume":"53","author":"MJ Budoff","year":"2009","unstructured":"Budoff MJ, et al. Coronary Calcium Predicts Events Better With Absolute Calcium Scores Than Age-Sex-Race\/Ethnicity Percentiles: MESA (Multi-Ethnic Study of Atherosclerosis). J Am Coll Cardiol. 2009;53:345\u201352.","journal-title":"J Am Coll Cardiol"},{"key":"2110_CR77","doi-asserted-by":"publisher","first-page":"2803","DOI":"10.1016\/j.jacc.2020.10.021","volume":"76","author":"MB Mortensen","year":"2020","unstructured":"Mortensen MB, et al. Impact of Plaque Burden Versus Stenosis on Ischemic Events in Patients With Coronary Atherosclerosis. J Am Coll Cardiol. 2020;76:2803\u201313.","journal-title":"J Am Coll Cardiol"},{"key":"2110_CR78","doi-asserted-by":"publisher","first-page":"1257","DOI":"10.1001\/jamacardio.2021.3055","volume":"6","author":"AR van Rosendael","year":"2021","unstructured":"van Rosendael AR, et al. Association of Statin Treatment With Progression of Coronary Atherosclerotic Plaque Composition. JAMA Cardiol. 2021;6:1257\u201366.","journal-title":"JAMA Cardiol"},{"key":"2110_CR79","doi-asserted-by":"publisher","first-page":"3233","DOI":"10.1016\/j.jacc.2018.09.051","volume":"72","author":"JD Mitchell","year":"2018","unstructured":"Mitchell JD, et al. Impact of Statins on Cardiovascular Outcomes Following Coronary Artery Calcium Scoring. J Am Coll Cardiol. 2018;72:3233\u201342.","journal-title":"J Am Coll Cardiol"},{"key":"2110_CR80","doi-asserted-by":"publisher","first-page":"434","DOI":"10.1016\/j.jacc.2018.05.027","volume":"72","author":"P Greenland","year":"2018","unstructured":"Greenland P, Blaha MJ, Budoff MJ, Erbel R, Watson KE. Coronary Calcium Score and Cardiovascular Risk. J Am Coll Cardiol. 2018;72:434\u201347.","journal-title":"J Am Coll Cardiol"},{"key":"2110_CR81","doi-asserted-by":"publisher","first-page":"2388","DOI":"10.1093\/eurheartj\/ehad152","volume":"44","author":"R De Bosscher","year":"2023","unstructured":"De Bosscher R, et al. Lifelong endurance exercise and its relation with coronary atherosclerosis. Eur Heart J. 2023;44:2388\u201399.","journal-title":"Eur Heart J"},{"key":"2110_CR82","unstructured":"Recent-onset chest pain of suspected cardiac origin: assessment and diagnosis. London: National Institute for Health and Care Excellence (NICE); 2016 Nov 30. (NICE Clinical Guidelines, No. 95.) Available from: https:\/\/www.ncbi.nlm.nih.gov\/books\/NBK553650\/"},{"key":"2110_CR83","doi-asserted-by":"publisher","first-page":"3097","DOI":"10.1161\/CIR.0b013e3182776f83","volume":"126","author":"SD Fihn","year":"2012","unstructured":"Fihn SD, et al. 2012 ACCF\/AHA\/ACP\/AATS\/PCNA\/SCAI\/STS guideline for the diagnosis and management of patients with stable ischemic heart disease: executive summary: a report of the American College of Cardiology Foundation\/American Heart Association task force on practice guidelines, and the American College of Physicians, American Association for Thoracic Surgery, Preventive Cardiovascular Nurses Association, Society for Cardiovascular Angiography and Interventions, and Society of Thoracic Surgeons. Circulation. 2012;126:3097\u2013137.","journal-title":"Circulation"},{"key":"2110_CR84","doi-asserted-by":"publisher","first-page":"1289","DOI":"10.1093\/eurheartj\/ehaa575","volume":"42","author":"J-P Collet","year":"2021","unstructured":"Collet J-P, et al. 2020 ESC Guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation: The Task Force for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation of the European Society of Cardiology (ESC). Eur Heart J. 2021;42:1289\u2013367.","journal-title":"Eur Heart J"},{"key":"2110_CR85","doi-asserted-by":"publisher","first-page":"3322","DOI":"10.1093\/eurheartj\/ehy267","volume":"39","author":"J Knuuti","year":"2018","unstructured":"Knuuti J, et al. The performance of non-invasive tests to rule-in and rule-out significant coronary artery stenosis in patients with stable angina: a meta-analysis focused on post-test disease probability. Eur Heart J. 2018;39:3322\u201330.","journal-title":"Eur Heart J"},{"key":"2110_CR86","doi-asserted-by":"publisher","first-page":"1993","DOI":"10.1161\/CIRCULATIONAHA.117.030578","volume":"136","author":"MJ Budoff","year":"2017","unstructured":"Budoff MJ, et al. Prognostic Value of Coronary Artery Calcium in the PROMISE Study (Prospective Multicenter Imaging Study for Evaluation of Chest Pain). Circulation. 2017;136:1993\u20132005.","journal-title":"Circulation"},{"key":"2110_CR87","doi-asserted-by":"publisher","first-page":"924","DOI":"10.1056\/NEJMoa1805971","volume":"379","author":"SCOT-HEART Investigators","year":"2018","unstructured":"SCOT-HEART Investigators, et al. Coronary CT Angiography and 5-Year Risk of Myocardial Infarction. N Engl J Med. 2018;379:924\u201333.","journal-title":"N Engl J Med"},{"key":"2110_CR88","doi-asserted-by":"publisher","first-page":"2533","DOI":"10.1016\/j.jacc.2011.10.851","volume":"58","author":"TC Villines","year":"2011","unstructured":"Villines TC, et al. Prevalence and severity of coronary artery disease and adverse events among symptomatic patients with coronary artery calcification scores of zero undergoing coronary computed tomography angiography: results from the CONFIRM (Coronary CT Angiography Evaluation for Clinical Outcomes: An International Multicenter) registry. J Am Coll Cardiol. 2011;58:2533\u201340.","journal-title":"J Am Coll Cardiol"},{"key":"2110_CR89","doi-asserted-by":"crossref","unstructured":"Maurovich-Horvat, P.; Bosserdt, M.; Kofoed, K.F.; Rieckmann, N.; Benedek, T.; Donnelly, P.; Rodriguez-Palomares, J.; Erglis, A.; \u0160t\u011bchovsk\u00fd, C.; \u0160akalyte, G. CT or invasive coronary angiography in stable chest pain. N. Engl. J. Med. 2022, 386, 1591\u20131602","DOI":"10.1056\/NEJMoa2200963"},{"key":"2110_CR90","doi-asserted-by":"publisher","first-page":"e200563","DOI":"10.1148\/ryct.2021200563","volume":"3","author":"LV Kl\u00fcner","year":"2021","unstructured":"Kl\u00fcner LV, Oikonomou EK, Antoniades C. Assessing Cardiovascular Risk by Using the Fat Attenuation Index in Coronary CT Angiography. Radiol Cardiothorac Imaging. 2021;3:e200563.","journal-title":"Radiol Cardiothorac Imaging"},{"key":"2110_CR91","first-page":"356","volume":"102","author":"AM Agus","year":"2016","unstructured":"Agus AM, et al. The cost-effectiveness of cardiac computed tomography for patients with stable chest pain. Heart Br Card Soc. 2016;102:356\u201362.","journal-title":"Heart Br Card Soc"},{"key":"2110_CR92","doi-asserted-by":"publisher","first-page":"1257","DOI":"10.2214\/AJR.09.3209","volume":"194","author":"EJ Halpern","year":"2010","unstructured":"Halpern EJ, Savage MP, Fischman DL, Levin DC. Cost-effectiveness of coronary CT angiography in evaluation of patients without symptoms who have positive stress test results. AJR Am J Roentgenol. 2010;194:1257\u201362.","journal-title":"AJR Am J Roentgenol"},{"key":"2110_CR93","doi-asserted-by":"publisher","first-page":"536","DOI":"10.1016\/j.jcct.2022.07.002","volume":"16","author":"RC Cury","year":"2022","unstructured":"Cury RC, et al. CAD-RADSTM 2.0 - 2022 Coronary Artery Disease-Reporting and Data System: An Expert Consensus Document of the Society of Cardiovascular Computed Tomography (SCCT), the American College of Cardiology (ACC), the American College of Radiology (ACR), and the North America Society of Cardiovascular Imaging (NASCI). J Cardiovasc Comput Tomogr. 2022;16:536\u201357.","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"2110_CR94","doi-asserted-by":"publisher","first-page":"1414","DOI":"10.1016\/j.jacc.2011.03.068","volume":"58","author":"JA Goldstein","year":"2011","unstructured":"Goldstein JA, et al. The CT-STAT (Coronary Computed Tomographic Angiography for Systematic Triage of Acute Chest Pain Patients to Treatment) trial. J Am Coll Cardiol. 2011;58:1414\u201322.","journal-title":"J Am Coll Cardiol"},{"key":"2110_CR95","doi-asserted-by":"publisher","first-page":"1393","DOI":"10.1056\/NEJMoa1201163","volume":"366","author":"HI Litt","year":"2012","unstructured":"Litt HI, et al. CT Angiography for Safe Discharge of Patients with Possible Acute Coronary Syndromes. N Engl J Med. 2012;366:1393\u2013403.","journal-title":"N Engl J Med"},{"key":"2110_CR96","doi-asserted-by":"publisher","first-page":"299","DOI":"10.1056\/NEJMoa1201161","volume":"367","author":"U Hoffmann","year":"2012","unstructured":"Hoffmann U, et al. Coronary CT Angiography versus Standard Evaluation in Acute Chest Pain. N Engl J Med. 2012;367:299\u2013308.","journal-title":"N Engl J Med"},{"key":"2110_CR97","doi-asserted-by":"publisher","first-page":"e190050","DOI":"10.1148\/ryct.2019190050","volume":"1","author":"BL N\u00f8rgaard","year":"2019","unstructured":"N\u00f8rgaard BL, et al. Coronary CT Angiography-derived Fractional Flow Reserve Testing in Patients with Stable Coronary Artery Disease: Recommendations on Interpretation and Reporting. Radiol Cardiothorac Imaging. 2019;1:e190050.","journal-title":"Radiol Cardiothorac Imaging"},{"key":"2110_CR98","doi-asserted-by":"publisher","first-page":"342","DOI":"10.1016\/j.jcct.2014.07.003","volume":"8","author":"J Leipsic","year":"2014","unstructured":"Leipsic J, et al. SCCT guidelines for the interpretation and reporting of coronary CT angiography: a report of the Society of Cardiovascular Computed Tomography Guidelines Committee. J Cardiovasc Comput Tomogr. 2014;8:342\u201358.","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"2110_CR99","doi-asserted-by":"publisher","first-page":"1237","DOI":"10.1001\/2012.jama.11274","volume":"308","author":"JK Min","year":"2012","unstructured":"Min JK, et al. Diagnostic accuracy of fractional flow reserve from anatomic CT angiography. JAMA. 2012;308:1237\u201345.","journal-title":"JAMA"},{"key":"2110_CR100","first-page":"42","volume":"16","author":"Z-Q Wang","year":"2019","unstructured":"Wang Z-Q, et al. Diagnostic accuracy of a deep learning approach to calculate FFR from coronary CT angiography. J Geriatr Cardiol JGC. 2019;16:42\u20138.","journal-title":"J Geriatr Cardiol JGC"},{"key":"2110_CR101","doi-asserted-by":"publisher","first-page":"1469","DOI":"10.1016\/j.amjcard.2015.07.078","volume":"116","author":"JA Gonzalez","year":"2015","unstructured":"Gonzalez JA, et al. Meta-Analysis of Diagnostic Performance of Coronary Computed Tomography Angiography, Computed Tomography Perfusion, and Computed Tomography-Fractional Flow Reserve in Functional Myocardial Ischemia Assessment Versus Invasive Fractional Flow Reserve. Am J Cardiol. 2015;116:1469\u201378.","journal-title":"Am J Cardiol"},{"key":"2110_CR102","doi-asserted-by":"publisher","first-page":"3844","DOI":"10.1093\/eurheartj\/ehab444","volume":"42","author":"N Curzen","year":"2021","unstructured":"Curzen N, et al. Fractional flow reserve derived from computed tomography coronary angiography in the assessment and management of stable chest pain: the FORECAST randomized trial. Eur Heart J. 2021;42:3844\u201352.","journal-title":"Eur Heart J"},{"key":"2110_CR103","doi-asserted-by":"publisher","first-page":"1041","DOI":"10.1007\/s00330-011-2345-6","volume":"22","author":"E Maffei","year":"2012","unstructured":"Maffei E, et al. Left and right ventricle assessment with Cardiac CT: validation study vs. Cardiac MR Eur Radiol. 2012;22:1041\u20139.","journal-title":"Cardiac MR Eur Radiol"},{"key":"2110_CR104","doi-asserted-by":"publisher","first-page":"594","DOI":"10.1016\/j.acra.2016.12.007","volume":"24","author":"FN Rahaghi","year":"2017","unstructured":"Rahaghi FN, et al. Ventricular geometry from non-contrast non-ECG gated CT scans: an imaging marker of cardiopulmonary disease in smokers. Acad Radiol. 2017;24:594\u2013602.","journal-title":"Acad Radiol"},{"key":"2110_CR105","doi-asserted-by":"publisher","first-page":"3798","DOI":"10.1088\/1361-6560\/aa63cb","volume":"62","author":"R Shahzad","year":"2017","unstructured":"Shahzad R, et al. Automatic segmentation and quantification of the cardiac structures from non-contrast-enhanced cardiac CT scans. Phys Med Biol. 2017;62:3798\u2013813.","journal-title":"Phys Med Biol"},{"key":"2110_CR106","doi-asserted-by":"publisher","first-page":"316","DOI":"10.1016\/j.jcct.2018.04.001","volume":"12","author":"MH Fredgart","year":"2018","unstructured":"Fredgart MH, et al. Measurement of left atrial volume by 2D and 3D non-contrast computed tomography compared with cardiac magnetic resonance imaging. J Cardiovasc Comput Tomogr. 2018;12:316\u20139.","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"2110_CR107","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1186\/1532-429X-14-90","volume":"14","author":"S Liu","year":"2012","unstructured":"Liu S, et al. Diffuse myocardial fibrosis evaluation using cardiac magnetic resonance T1 mapping: sample size considerations for clinical trials. J Cardiovasc Magn Reson. 2012;14:90.","journal-title":"J Cardiovasc Magn Reson"},{"key":"2110_CR108","doi-asserted-by":"publisher","first-page":"2638","DOI":"10.1016\/j.jacc.2019.09.056","volume":"74","author":"J Ternacle","year":"2019","unstructured":"Ternacle J, et al. Aortic Stenosis and Cardiac Amyloidosis: JACC Review Topic of the Week. J Am Coll Cardiol. 2019;74:2638\u201351.","journal-title":"J Am Coll Cardiol"},{"key":"2110_CR109","doi-asserted-by":"publisher","first-page":"2177","DOI":"10.1016\/j.jcmg.2020.05.029","volume":"13","author":"PR Scully","year":"2020","unstructured":"Scully PR, et al. Identifying Cardiac Amyloid in Aortic Stenosis: ECV Quantification by CT in TAVR Patients. JACC Cardiovasc Imaging. 2020;13:2177\u201389.","journal-title":"JACC Cardiovasc Imaging"},{"key":"2110_CR110","doi-asserted-by":"publisher","first-page":"e159","DOI":"10.1016\/j.jacc.2020.08.045","volume":"76","author":"SR Ommen","year":"2020","unstructured":"Ommen SR, et al. 2020 AHA\/ACC Guideline for the Diagnosis and Treatment of Patients With Hypertrophic Cardiomyopathy: A Report of the American College of Cardiology\/American Heart Association Joint Committee on Clinical Practice Guidelines. J Am Coll Cardiol. 2020;76:e159\u2013240.","journal-title":"J Am Coll Cardiol"},{"key":"2110_CR111","doi-asserted-by":"publisher","first-page":"597","DOI":"10.1016\/j.jcmg.2015.02.007","volume":"8","author":"ASJM Te Riele","year":"2015","unstructured":"Te Riele ASJM, Tandri H, Sanborn DM, Bluemke DA. Noninvasive Multimodality Imaging in ARVD\/C. JACC Cardiovasc Imaging. 2015;8:597\u2013611.","journal-title":"JACC Cardiovasc Imaging"},{"key":"2110_CR112","doi-asserted-by":"publisher","first-page":"561","DOI":"10.1093\/eurheartj\/ehab395","volume":"43","author":"A Vahanian","year":"2022","unstructured":"Vahanian A, et al. 2021 ESC\/EACTS Guidelines for the management of valvular heart disease: Developed by the Task Force for the management of valvular heart disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS). Eur Heart J. 2022;43:561\u2013632.","journal-title":"Eur Heart J"},{"key":"2110_CR113","doi-asserted-by":"crossref","unstructured":"Evertz R, Hub S, Kowallick JT, Seidler T, Danner BC, Hasenfu\u00df G, et al. Impact of observer experience on multidetector computed tomography aortic valve morphology assessment and valve size selection for transcatheter aortic valve replacement. Sci Rep. 2022;12:21430.","DOI":"10.1038\/s41598-022-23936-w"},{"key":"2110_CR114","doi-asserted-by":"crossref","unstructured":"Evertz R, Hub S, Backhaus SJ, Lange T, Toischer K, Kowallick JT, et al. Head-to-Head Comparison of Different Software Solutions for AVC Quantification Using Contrast-Enhanced MDCT. J Clin Med. 2021;10:3970.","DOI":"10.3390\/jcm10173970"},{"key":"2110_CR115","doi-asserted-by":"crossref","unstructured":"Evertz R, Hub S, Beuthner BE, Backhaus SJ, Lange T, Schulz A, et al. Aortic valve calcification and myocardial fibrosis determine outcome following transcatheter aortic valve replacement. ESC Heart Fail. 2023;10:2307\u201318.","DOI":"10.1002\/ehf2.14307"},{"key":"2110_CR116","doi-asserted-by":"publisher","first-page":"290","DOI":"10.1016\/j.jcct.2018.02.002","volume":"12","author":"NC Hansson","year":"2018","unstructured":"Hansson NC, et al. Aortic valve and left ventricular outflow tract calcium volume and distribution in transcatheter aortic valve replacement: Influence on the risk of significant paravalvular regurgitation. J Cardiovasc Comput Tomogr. 2018;12:290\u20137.","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"2110_CR117","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1161\/CIRCULATIONAHA.113.002947","volume":"128","author":"M Barbanti","year":"2013","unstructured":"Barbanti M, et al. Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement. Circulation. 2013;128:244\u201353.","journal-title":"Circulation"},{"key":"2110_CR118","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1016\/j.jcin.2018.12.001","volume":"12","author":"S-H Yoon","year":"2019","unstructured":"Yoon S-H, et al. Predictors of Left Ventricular Outflow Tract Obstruction After Transcatheter Mitral Valve Replacement. JACC Cardiovasc Interv. 2019;12:182\u201393.","journal-title":"JACC Cardiovasc Interv"},{"key":"2110_CR119","doi-asserted-by":"publisher","first-page":"e136","DOI":"10.1093\/ehjci\/jeab292","volume":"23","author":"G Pontone","year":"2022","unstructured":"Pontone G, et al. Clinical applications of cardiac computed tomography: a consensus paper of the European Association of Cardiovascular Imaging-part II. Eur Heart J Cardiovasc Imaging. 2022;23:e136\u201361.","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"2110_CR120","doi-asserted-by":"publisher","unstructured":"Schulz A, Beuthner BE, B\u00f6ttiger ZM, Gersch SS, Lange T, Gronwald J, et al. Epicardial adipose tissue as an independent predictor of long-term outcome in patients with severe aortic stenosis undergoing transcatheter aortic valve replacement. Clin Res Cardiol. 2024. https:\/\/doi.org\/10.1007\/s00392-024-02387-5.","DOI":"10.1007\/s00392-024-02387-5"},{"key":"2110_CR121","doi-asserted-by":"publisher","first-page":"3948","DOI":"10.1093\/eurheartj\/ehad193","volume":"44","author":"V Delgado","year":"2023","unstructured":"Delgado V, et al. 2023 ESC Guidelines for the management of endocarditis: Developed by the task force on the management of endocarditis of the European Society of Cardiology (ESC) Endorsed by the European Association for Cardio-Thoracic Surgery (EACTS) and the European Association of Nuclear Medicine (EANM). Eur Heart J. 2023;44:3948\u20134042.","journal-title":"Eur Heart J"},{"key":"2110_CR122","doi-asserted-by":"publisher","DOI":"10.1007\/s00246-022-03069-7","author":"M Nagiub","year":"2022","unstructured":"Nagiub M, et al. Value of Time-Resolved Cardiac CT in Children and Young Adults with Congenital Heart Disease and Infective Endocarditis. Pediatr Cardiol. 2022. https:\/\/doi.org\/10.1007\/s00246-022-03069-7.","journal-title":"Pediatr Cardiol"},{"key":"2110_CR123","first-page":"100542","volume":"29","author":"BMF Hendriks","year":"2020","unstructured":"Hendriks BMF, Martens B, Mihl C. Pre-procedural computed tomography in transcatheter pulmonary valve replacement: The first steps towards standardization of image quality. Int J Cardiol Heart Vasc. 2020;29:100542.","journal-title":"Int J Cardiol Heart Vasc"},{"key":"2110_CR124","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1016\/j.jcct.2023.02.003","volume":"17","author":"AM Ferraro","year":"2023","unstructured":"Ferraro AM, et al. Computed tomography angiography (CTA) of anomalous aortic origin of a coronary artery (AAOCA): Which measurements are accurate and reliable? J Cardiovasc Comput Tomogr. 2023;17:130\u20137.","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"2110_CR125","doi-asserted-by":"publisher","first-page":"507","DOI":"10.21037\/cdt.2017.01.12","volume":"7","author":"JM Otton","year":"2017","unstructured":"Otton JM, et al. 3D printing from cardiovascular CT: a practical guide and review. Cardiovasc Diagn Ther. 2017;7:507\u201326.","journal-title":"Cardiovasc Diagn Ther"}],"container-title":["Current Cardiology Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11886-024-02110-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11886-024-02110-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11886-024-02110-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,9]],"date-time":"2024-10-09T04:10:24Z","timestamp":1728447024000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11886-024-02110-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,20]]},"references-count":125,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2024,10]]}},"alternative-id":["2110"],"URL":"https:\/\/doi.org\/10.1007\/s11886-024-02110-w","relation":{},"ISSN":["1523-3782","1534-3170"],"issn-type":[{"value":"1523-3782","type":"print"},{"value":"1534-3170","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,8,20]]},"assertion":[{"value":"26 July 2024","order":1,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 August 2024","order":2,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of Interest"}},{"value":"This article does not contain any studies with human or animal subjects performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Human and Animal Rights and Informed Consent"}}]}}