{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,26]],"date-time":"2026-02-26T09:56:28Z","timestamp":1772099788321,"version":"3.50.1"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,12,1]],"date-time":"2025-12-01T00:00:00Z","timestamp":1764547200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,12,1]],"date-time":"2025-12-01T00:00:00Z","timestamp":1764547200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Curr Cardiol Rep"],"published-print":{"date-parts":[[2025,12]]},"DOI":"10.1007\/s11886-025-02290-z","type":"journal-article","created":{"date-parts":[[2025,12,12]],"date-time":"2025-12-12T08:35:42Z","timestamp":1765528542000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["The New Ice Age in Electrophysiology: Ultra-Low-Temperature Cryoablation for Ventricular Tachycardia"],"prefix":"10.1007","volume":"27","author":[{"given":"Vadivelu","family":"Ramalingam","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elie","family":"Ganni","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Katia","family":"Dyrda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vidal","family":"Essebag","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jacqueline","family":"Joza","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Atul","family":"Verma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,12,12]]},"reference":[{"issue":"2","key":"2290_CR1","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1056\/NEJMoa1513614","volume":"375","author":"JL Sapp","year":"2016","unstructured":"Sapp JL, Wells GA, Parkash R, Stevenson WG, Blier L, Sarrazin JF, Thibault B, Rivard L, Gula L, Leong-Sit P, Essebag V. Ventricular tachycardia ablation versus escalation of antiarrhythmic drugs. N Engl J Med. 2016;375(2):111\u201321.","journal-title":"N Engl J Med"},{"issue":"4","key":"2290_CR2","doi-asserted-by":"publisher","first-page":"euae076","DOI":"10.1093\/europace\/euae076","volume":"26","author":"A Verma","year":"2024","unstructured":"Verma A, Essebag V, Neuzil P, Dyrda K, Balt J, Dinov B, Darma A, Arya A, Sacher F, Reddy VY, Boersma L. Cryocure-VT: the safety and effectiveness of ultra-low-temperature cryoablation of monomorphic ventricular tachycardia in patients with ischaemic and non-ischaemic cardiomyopathies. Europace. 2024;26(4):euae076.","journal-title":"Europace"},{"issue":"9","key":"2290_CR3","doi-asserted-by":"publisher","first-page":"1997","DOI":"10.1016\/j.hrthm.2015.05.036","volume":"12","author":"R Tung","year":"2015","unstructured":"Tung R, Vaseghi M, Frankel DS, Vergara P, Di Biase L, Nagashima K, Yu R, Vangala S, Tseng CH, Choi EK, Khurshid S. Freedom from recurrent ventricular tachycardia after catheter ablation is associated with improved survival in patients with structural heart disease: an international VT ablation center collaborative group study. Heart Rhythm. 2015;12(9):1997\u20132007.","journal-title":"Heart Rhythm"},{"issue":"12","key":"2290_CR4","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.116.004432","volume":"9","author":"KC Siontis","year":"2016","unstructured":"Siontis KC, Kim HM, Stevenson WG, Fujii A, Della Bella P, Vergara P, et al. Prognostic impact of the timing of recurrence of infarct-related ventricular tachycardia after catheter ablation. Circ Arrhythm Electrophysiol. 2016;9(12):e004432.","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"4","key":"2290_CR5","first-page":"502","volume":"38","author":"WG Stevenson","year":"2022","unstructured":"Stevenson WG, Sapp JL. Newer methods for ventricular tachycardia ablation and when to use them. Can J Cardiol. 2022;38(4):502\u201314.","journal-title":"Can J Cardiol"},{"issue":"8","key":"2290_CR6","volume":"15","author":"DL Packer","year":"2022","unstructured":"Packer DL, Wilber DJ, Kapa S, Dyrda K, Nault I, Killu AM, et al. Ablation of refractory ventricular tachycardia using intramyocardial needle delivered heated saline-enhanced radiofrequency energy: a first-in-man feasibility trial. Circulation: Arrhythmia and Electrophysiology. 2022;15(8):e010347.","journal-title":"Circulation: Arrhythmia and Electrophysiology"},{"issue":"6","key":"2290_CR7","doi-asserted-by":"publisher","first-page":"950","DOI":"10.1016\/j.hrthm.2024.01.052","volume":"21","author":"TR Maher","year":"2024","unstructured":"Maher TR, Raza AS, Tapias C, Garcia F, Reynolds MR, Chaudry GM, Saenz LC, Valderr\u00e1bano M, d\u2019Avila A. Ventricular septal defect as a complication of bipolar radiofrequency ablation for ventricular tachycardia. Heart Rhythm. 2024;21(6):950\u20135.","journal-title":"Heart Rhythm"},{"issue":"7","key":"2290_CR8","doi-asserted-by":"publisher","first-page":"968","DOI":"10.1016\/j.hrthm.2011.02.038","volume":"8","author":"L Di Biase","year":"2011","unstructured":"Di Biase L, Al-Ahamad A, Santangeli P, Hsia HH, Sanchez J, Bai R, Bailey S, Horton R, Gallinghouse GJ, Burkhardt DJ, Lakkireddy D. Safety and outcomes of cryoablation for ventricular tachyarrhythmias: results from a multicenter experience. Heart Rhythm. 2011;8(7):968\u201374.","journal-title":"Heart Rhythm"},{"issue":"8","key":"2290_CR9","doi-asserted-by":"publisher","first-page":"1034","DOI":"10.1016\/j.jacep.2022.05.017","volume":"8","author":"T De Potter","year":"2022","unstructured":"De Potter T, Klaver M, Babkin A, Iliodromitis K, Hocini M, Cox J, Boersma L. Ultra-low temperature cryoablation for atrial fibrillation: primary outcomes for efficacy and safety: the cryocure-2 study. Clin Electrophysiol. 2022;8(8):1034\u20139.","journal-title":"Clin Electrophysiol"},{"key":"2290_CR10","doi-asserted-by":"crossref","unstructured":"Subedi J, Hansen B, White M, Patel V, Makara J, Atassi O, Johnson G. Nitrogen Precooling Heat Exchanger replacement and control system upgrade in Superfluid Cryoplant at CMTF. InIOP Conference Series: Materials Science and Engineering 2024 May 1 (Vol. 1301, No. 1, p. 012038). IOP Publishing.","DOI":"10.1088\/1757-899X\/1301\/1\/012038"},{"issue":"3","key":"2290_CR11","doi-asserted-by":"publisher","first-page":"570","DOI":"10.1111\/jce.14907","volume":"32","author":"F Bourier","year":"2021","unstructured":"Bourier F, Takigawa M, Lam A, Vlachos K, Ramirez FD, Martin CA, et al. Ultralow temperature cryoablation: safety and efficacy of preclinical atrial and ventricular lesions. J Cardiovasc Electrophysiol. 2021;32(3):570\u20137.","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"5","key":"2290_CR12","doi-asserted-by":"publisher","first-page":"S92","DOI":"10.1016\/j.hrthm.2023.03.395","volume":"20","author":"TA Dewland","year":"2023","unstructured":"Dewland TA, Higuchi S, Venkateswaran R, Lee C, Gerstenfeld EP. AB-452672-2 ultra-low temperature cryoablation versus ultra-low temperature cryoablation combined with pulsed field ablation in a swine ventricular infarct model. Heart Rhythm. 2023;20(5):S92-3.","journal-title":"Heart Rhythm"},{"issue":"10","key":"2290_CR13","doi-asserted-by":"publisher","first-page":"2124","DOI":"10.1111\/jce.15701","volume":"34","author":"A Verma","year":"2023","unstructured":"Verma A, Feld GK, Cox JL, Dewland TA, Babkin A, De Potter T, et al. Combined pulsed field ablation with ultra-low temperature cryoablation: a preclinical experience. J Cardiovasc Electrophysiol. 2023;34(10):2124\u201333.","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"5","key":"2290_CR14","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1016\/j.hrcr.2022.02.013","volume":"8","author":"M Liebregts","year":"2022","unstructured":"Liebregts M, van Dijk VF, Boersma LV, Balt JC. Ablation of ventricular tachycardia using state-of-the-art preprocedural imaging, magnetic-based 3-dimensional mapping, and ultra-low-temperature cryoablation technology. HeartRhythm Case Rep. 2022;8(5):390.","journal-title":"HeartRhythm Case Rep"},{"issue":"8","key":"2290_CR15","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1016\/j.hrcr.2022.05.009","volume":"8","author":"P Sanchez-Somonte","year":"2022","unstructured":"Sanchez-Somonte P, Kittichamroen N, Verma A. Novel case of linear ultra-low cryoablation catheter for treatment of ventricular tachycardia. HeartRhythm Case Rep. 2022;8(8):549\u201353.","journal-title":"HeartRhythm Case Rep"},{"issue":"5","key":"2290_CR16","doi-asserted-by":"publisher","first-page":"686","DOI":"10.1016\/j.jacep.2022.11.017","volume":"9","author":"T De Potter","year":"2023","unstructured":"De Potter T, Balt JC, Boersma L, Sacher F, Neuzil P, Reddy V, et al. First-in-human experience with ultra-low temperature cryoablation for monomorphic ventricular tachycardia. JACC Clin Electrophysiol. 2023;9(5):686\u201391.","journal-title":"JACC Clin Electrophysiol"},{"issue":"3","key":"2290_CR17","doi-asserted-by":"publisher","first-page":"560","DOI":"10.1016\/j.cjco.2023.11.009","volume":"6","author":"P Sanchez-Somonte","year":"2024","unstructured":"Sanchez-Somonte P, Verma A, Da Rosa LGB, Anglesio V, Poletaev V, Alturki A, et al. Ultra-low\u2013temperature cryoablation for ventricular tachycardia: an early single-centre report of acute results. CJC Open. 2024;6(3):560\u20138.","journal-title":"CJC Open"},{"issue":"7","key":"2290_CR18","doi-asserted-by":"publisher","first-page":"728","DOI":"10.1161\/CIRCULATIONAHA.113.003063","volume":"129","author":"B Dinov","year":"2014","unstructured":"Dinov B, Fiedler L, Sch\u00f6nbauer R, Bollmann A, Rolf S, Piorkowski C, Hindricks G, Arya A. Outcomes in catheter ablation of ventricular tachycardia in dilated nonischemic cardiomyopathy compared with ischemic cardiomyopathy: results from the prospective heart centre of Leipzig VT (HELP-VT) study. Circulation. 2014;129(7):728\u201336.","journal-title":"Circulation"},{"issue":"10","key":"2290_CR19","doi-asserted-by":"publisher","first-page":"1957","DOI":"10.1016\/j.hrthm.2016.07.001","volume":"13","author":"S Kumar","year":"2016","unstructured":"Kumar S, Romero J, Mehta NK, Fujii A, Kapur S, Baldinger SH, et al. Long-term outcomes after catheter ablation of ventricular tachycardia in patients with and without structural heart disease. Heart Rhythm. 2016;13(10):1957\u201363.","journal-title":"Heart Rhythm"},{"issue":"8","key":"2290_CR20","doi-asserted-by":"publisher","first-page":"1143","DOI":"10.1093\/europace\/euz132","volume":"21","author":"EM Cronin","year":"2019","unstructured":"Cronin EM, Bogun FM, Maury P, Peichl P, Chen M, Namboodiri N, Aguinaga L, Leite LR, Al-Khatib SM, Anter E, Berruezo A. 2019 HRS\/EHRA\/APHRS\/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias. EP Europace. 2019;21(8):1143\u20134.","journal-title":"EP Europace"},{"issue":"9","key":"2290_CR21","doi-asserted-by":"publisher","first-page":"1500","DOI":"10.1016\/j.hrthm.2020.04.028","volume":"17","author":"M Igarashi","year":"2020","unstructured":"Igarashi M, Nogami A, Fukamizu S, Sekiguchi Y, Nitta J, Sakamoto N, Sakamoto Y, Kurosaki K, Takahashi Y, Kimata A, Komatsu Y. Acute and long-term results of bipolar radiofrequency catheter ablation of refractory ventricular arrhythmias of deep intramural origin. Heart Rhythm. 2020;17(9):1500\u20137.","journal-title":"Heart Rhythm"},{"issue":"1","key":"2290_CR22","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1007\/s10840-021-00948-6","volume":"63","author":"WY Ding","year":"2022","unstructured":"Ding WY, Pearman CM, Bonnett L, Adlan A, Chin SH, Denham N, et al. Complication rates following ventricular tachycardia ablation in ischaemic and non-ischaemic cardiomyopathies: a systematic review. J Interv Card Electrophysiol. 2022;63(1):59\u201367.","journal-title":"J Interv Card Electrophysiol"},{"issue":"8","key":"2290_CR23","first-page":"1277","volume":"38","author":"P Sanchez-Somonte","year":"2022","unstructured":"Sanchez-Somonte P, Dryda K, Nault I, Rivard L, Verma A. Evaluation of saline-enhanced radiofrequency needle-tip ablation for ventricular tachycardia (SERF VT Canada trial). Can J Cardiol. 2022;38(8):1277\u201385.","journal-title":"Can J Cardiol"},{"issue":"4","key":"2290_CR24","doi-asserted-by":"publisher","first-page":"S46","DOI":"10.1016\/j.hrthm.2025.03.096","volume":"22","author":"A Verma","year":"2025","unstructured":"Verma A, Essebag V, Neuzil P, Dyrda K, Balt JC, Dinov B, et al. AB-499651-005 long-term outcomes of ultra-low temperature cryoablation of monomorphic VT in patients with structural heart disease: 1-year results from cryocure-VT study. Heart Rhythm. 2025;22(4):S46.","journal-title":"Heart Rhythm"},{"issue":"25","key":"2290_CR25","doi-asserted-by":"publisher","first-page":"2773","DOI":"10.1161\/CIRCULATIONAHA.108.788604","volume":"118","author":"WG Stevenson","year":"2008","unstructured":"Stevenson WG, Wilber DJ, Natale A, Jackman WM, Marchlinski FE, Talbert T, et al. Irrigated radiofrequency catheter ablation guided by electroanatomic mapping for recurrent ventricular tachycardia after myocardial infarction: the multicenter thermocool ventricular tachycardia ablation trial. Circulation. 2008;118(25):2773\u201382.","journal-title":"Circulation"},{"issue":"6","key":"2290_CR26","doi-asserted-by":"publisher","first-page":"674","DOI":"10.1016\/j.jacc.2015.11.041","volume":"67","author":"FE Marchlinski","year":"2016","unstructured":"Marchlinski FE, Haffajee CI, Beshai JF, Dickfeld TML, Gonzalez MD, Hsia HH, et al. Long-term success of irrigated radiofrequency catheter ablation of sustained ventricular tachycardia: Post-approval THERMOCOOL VT trial. J Am Coll Cardiol. 2016;67(6):674\u201383.","journal-title":"J Am Coll Cardiol"},{"issue":"4","key":"2290_CR27","doi-asserted-by":"publisher","first-page":"S44","DOI":"10.1016\/j.hrthm.2025.03.092","volume":"22","author":"K Dyrda","year":"2025","unstructured":"Dyrda K, Verma A, Dinov B, Fink T, Raffa S, De Potter T, et al. AB-499651-001 initial pre-clinical evaluation of the augmented ultra-low temperature cryoablation catheter for ventricular ablations. Heart Rhythm. 2025;22(4):S44.","journal-title":"Heart Rhythm"}],"container-title":["Current Cardiology Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11886-025-02290-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11886-025-02290-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11886-025-02290-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,26]],"date-time":"2026-02-26T08:57:02Z","timestamp":1772096222000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11886-025-02290-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12]]},"references-count":27,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2025,12]]}},"alternative-id":["2290"],"URL":"https:\/\/doi.org\/10.1007\/s11886-025-02290-z","relation":{},"ISSN":["1523-3782","1534-3170"],"issn-type":[{"value":"1523-3782","type":"print"},{"value":"1534-3170","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12]]},"assertion":[{"value":"7 August 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 August 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 December 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}},{"value":"This is a review, and no animal or human subjects were used by the authors for this review. Studies referenced in this review with human or animal subjects are published and followed ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Human and Animal Rights and Informed Consent"}},{"value":"Dr AV reports being a consultant for Biosense Webster, Medtronic, Adagio Medical, and Medlumics, unrelated to this manuscript. Dr KD reports being a consultant for Adagio and Thermedical and a speaker for Abbott, Johnson and Johnson, and Boston Scientific, unrelated to this manuscript. Dr VE has received honoraria from Abbott, Adagio, Biosense Webster, Boston Scientific, and Medtronic, unrelated to this manuscript. Dr. VE and Dr. JJ are recipients of Clinical Research Scholar Awards from the Fonds de recherche du Qu\u00e9bec-Sant\u00e9 (FRQS), unrelated to this manuscript. All other authors have nothing to declare.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}],"article-number":"173"}}