{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,14]],"date-time":"2026-02-14T06:53:25Z","timestamp":1771052005119,"version":"3.50.1"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2016,10,24]],"date-time":"2016-10-24T00:00:00Z","timestamp":1477267200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"name":"Boston Scientific Corporation (US)"},{"name":"Century Medical Inc."},{"name":"Zeon Medical Inc."}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Curr Gastroenterol Rep"],"published-print":{"date-parts":[[2016,12]]},"DOI":"10.1007\/s11894-016-0538-5","type":"journal-article","created":{"date-parts":[[2016,10,24]],"date-time":"2016-10-24T07:28:27Z","timestamp":1477294107000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":42,"title":["Understanding the Mechanical forces of Self-Expandable Metal Stents in the Biliary Ducts"],"prefix":"10.1007","volume":"18","author":[{"given":"Hiroyuki","family":"Isayama","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yousuke","family":"Nakai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tsuyoshi","family":"Hamada","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Saburo","family":"Matsubara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hirofumi","family":"Kogure","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kazuhiko","family":"Koike","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2016,10,24]]},"reference":[{"key":"538_CR1","doi-asserted-by":"crossref","first-page":"1488","DOI":"10.1016\/0140-6736(92)92752-2","volume":"340","author":"PH Davids","year":"1992","unstructured":"Davids PH, Groen AK, Rauws EA, Tytgat GN, Huibregtse K. Randomised trial of self-expanding metal stents versus polyethylene stents for distal malignant biliary obstruction. Lancet. 1992;340:1488\u201392.","journal-title":"Lancet"},{"key":"538_CR2","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1111\/den.12379","volume":"27","author":"K Knyrim","year":"2015","unstructured":"Knyrim K, Wagner HJ, Pausch J, Vakil N. A prospective, randomized, controlled trial of metal stents for malignant obstruction of the common bile duct. Endoscopy. 1993; 25: 207\u201312.Isayama H, Hamada T, Yasuda I, Itoi T, Ryozawa S, Nakai Y, et al. The TOKYO Criteria 2014 for Transpapillary Biliary Stenting. Dig Endosc. 2015;27:259\u201364.","journal-title":"Dig Endosc"},{"issue":"4","key":"538_CR3","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1111\/j.1443-1661.2011.01124.x","volume":"23","author":"H Isayama","year":"2011","unstructured":"Isayama H, Yasuda I, Ryozawa S, Maguchi H, Igarashi Y, Matsuyama Y, et al. Results of a Japanese multicenter, randomized trial of endoscopic stenting for non-resectable pancreatic head cancer (JM-test): covered wallstent versus doublelayer stent. Dig Endosc. 2011;23(4):310\u20135.","journal-title":"Dig Endosc"},{"key":"538_CR4","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/j.gie.2008.09.032","volume":"70","author":"H Isayama","year":"2009","unstructured":"\u2022 Isayama H, Nakai Y, Toyokawa Y, Togawa O, Gon C, Ito Y, et al. Measurement of radial and axial forces of biliary self-expandable metallic stents. Gastrointest Endosc. 2009;70:37\u201344. This article measured mechanical properties, radial and axil force and proposed axial force as new concept of mechanical properties of self-expandable metallic stent.","journal-title":"Gastrointest Endosc"},{"key":"538_CR5","doi-asserted-by":"crossref","first-page":"997","DOI":"10.1055\/s-0033-1344985","volume":"45","author":"MM Hirdes","year":"2013","unstructured":"Hirdes MM, Vleggaar FP, de Beule M, Siersema PD. In vitro evaluation of the radial and axial force of self-expanding esophageal stents. Endoscopy. 2013;45:997\u20131005.","journal-title":"Endoscopy"},{"key":"538_CR6","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1007\/s002709910007","volume":"23","author":"JF Dyet","year":"2000","unstructured":"Dyet JF, Watts WG, Ettles DF, et al. Mechanical properties of metallic stents: how do these properties influence the choice of stents for specific lesions? Cardiovasc Intervent Radiol. 2000;23:47\u201354.","journal-title":"Cardiovasc Intervent Radiol"},{"key":"538_CR7","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1016\/S1051-0443(07)61620-0","volume":"11","author":"S Duda","year":"2000","unstructured":"Duda S, Wiskirchen J, Tepe G, et al. Physical properties of endovascular stents: an experimental comparison. Soc Cardiovasc Intervent Radiol. 2000;11:645\u201354.","journal-title":"Soc Cardiovasc Intervent Radiol"},{"key":"538_CR8","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1002\/jab.770040111","volume":"4","author":"MR Jedwab","year":"1993","unstructured":"Jedwab MR, Clerc CO. A study of geometrical and mechanical properties of a self-expanding metallic stentdtheory and experiment. J Appl Biomater. 1993;4:77\u201385.","journal-title":"J Appl Biomater"},{"key":"538_CR9","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1007\/s00330-003-2022-5","volume":"14","author":"D Stoeckel","year":"2004","unstructured":"Stoeckel D, Pelton A, Duerig T. Self-expanding nitinol stents: material and design considerations. Eur Radiol. 2004;14:292\u2013301.","journal-title":"Eur Radiol"},{"key":"538_CR10","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1111\/j.1443-1661.2010.01043.x","volume":"23","author":"Y Nakai","year":"2011","unstructured":"Nakai Y, Isayama H, Togawa O, Kogure H, Tsujino T, Yagioka H, et al. New method of covered wallstents for distal malignant biliary obstruction to reduce early stent-related complications based on characteristics. Dig Endosc. 2011;23:49\u201355.","journal-title":"Dig Endosc"},{"key":"538_CR11","doi-asserted-by":"crossref","first-page":"646","DOI":"10.1007\/s00534-011-0406-5","volume":"18","author":"T Mukai","year":"2011","unstructured":"Mukai T, Yasuda I, Isayama H, Nakashima M, Doi S, Iwashita T, et al. Comparison of axial force and cell width of self-expandable metallic stents: which type of stent is better suited for hilar biliary strictures? J Hepatobiliary Pancreat Sci. 2011;18:646\u201352.","journal-title":"J Hepatobiliary Pancreat Sci"},{"key":"538_CR12","doi-asserted-by":"crossref","first-page":"748","DOI":"10.1016\/j.gie.2010.05.023","volume":"72","author":"GA Cot\u00e9","year":"2010","unstructured":"Cot\u00e9 GA, Kumar N, Ansstas M, Edmundowicz SA, Jonnalagadda S, Mullady DK, et al. Risk of post-ERCP pancreatitis with placement of self-expandable metallic stents. Gastrointest Endosc. 2010;72:748\u201354.","journal-title":"Gastrointest Endosc"},{"key":"538_CR13","doi-asserted-by":"crossref","first-page":"1151","DOI":"10.1016\/j.cgh.2015.01.008","volume":"13","author":"T Hayashi","year":"2015","unstructured":"Hayashi T, Kawakami H, Osanai M, Ishiwatari H, Naruse H, Hisai H, et al. No benefit of endoscopic sphincterotomy before biliary placement of self-expandable metal stents for unresectable pancreatic cancer. Clin Gastroenterol Hepatol. 2015;13:1151\u20138.","journal-title":"Clin Gastroenterol Hepatol"},{"key":"538_CR14","doi-asserted-by":"crossref","first-page":"771","DOI":"10.1007\/s00464-011-1950-4","volume":"26","author":"K Kawakubo","year":"2012","unstructured":"\u2022\u2022 Kawakubo K, Isayama H, Nakai Y, Togawa O, Sasahira N, Kogure H, et al. Risk factors for pancreatitis following transpapillary self-expandable metal stent placement. Surg Endosc. 2012;26:771\u20136. This article is the first report to reveal the relation between mechanical properties of SEMS and complications after placement.","journal-title":"Surg Endosc."},{"key":"538_CR15","doi-asserted-by":"crossref","first-page":"1148","DOI":"10.1016\/j.cgh.2006.06.004","volume":"4","author":"H Isayama","year":"2006","unstructured":"Isayama H, Kawabe T, Nakai Y, Tsujino T, Sasahira N, Yamamoto N, et al. Cholecystitis after metallic stent placement in patients with malignant distal biliary obstruction. Clin Gastroenterol Hepatol. 2006;4:1148\u201353.","journal-title":"Clin Gastroenterol Hepatol"},{"key":"538_CR16","doi-asserted-by":"crossref","first-page":"522","DOI":"10.1016\/j.gie.2006.06.022","volume":"64","author":"KT Suk","year":"2006","unstructured":"Suk KT, Kim HS, Kim JW, Baik SK, Kwon SO, Kim HG, et al. Risk factors for cholecystitis after metal stent placement in malignant biliary obstruction. Gastrointest Endosc. 2006;64:522\u20139.","journal-title":"Gastrointest Endosc"},{"issue":"1","key":"538_CR17","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1016\/j.gie.2007.12.063","volume":"68","author":"Y Nakai","year":"2008","unstructured":"Nakai Y, Isayama H, Tsujino T, Kawabe T, Yashima Y, Yagioka H, et al. Intraductal US in the assessment of tumor involvement to the orifice of the cystic duct by malignant biliary obstruction. Gastrointest Endosc. 2008;68(1):78\u201383.","journal-title":"Gastrointest Endosc"},{"key":"538_CR18","doi-asserted-by":"crossref","first-page":"1557","DOI":"10.1111\/jgh.12582","volume":"29","author":"Y Nakai","year":"2014","unstructured":"Nakai Y, Isayama H, Kawakubo K, Kogure H, Hamada T, Togawa O, et al. A metallic stent with high axial force was a risk factor for cholecystitis in distal malignant biliary obstruction. J Gastroenterol Hepatol. 2014;29:1557\u201362.","journal-title":"J Gastroenterol Hepatol"},{"key":"538_CR19","doi-asserted-by":"crossref","first-page":"907","DOI":"10.1016\/j.gie.2010.08.021","volume":"72","author":"JJ Telford","year":"2010","unstructured":"Telford JJ, Carr-Locke DL, Baron TH, Poneros JM, Bounds BC, Kelsey PB, et al. A randomized trial comparing uncovered and partially covered self-expandable metal stents in the palliation of distal malignant biliary obstruction. Gastrointest Endosc. 2010;72:907\u201314.","journal-title":"Gastrointest Endosc"},{"key":"538_CR20","doi-asserted-by":"crossref","first-page":"915","DOI":"10.1016\/j.gie.2010.07.036","volume":"72","author":"E Kullman","year":"2010","unstructured":"Kullman E, Frozanpor F, S\u00f6derlund C, et al. Covered versus uncovered self-expandable nitinol stents in the palliative treatment of malignant distal biliary obstruction: results from a randomized, multicenter study. Gastrointest Endosc. 2010;72:915\u201323.","journal-title":"Gastrointest Endosc"},{"key":"538_CR21","doi-asserted-by":"crossref","first-page":"1744","DOI":"10.1111\/jgh.12602","volume":"29","author":"Y Nakai","year":"2014","unstructured":"Nakai Y, Isayama H, Kogure H, Hamada T, Togawa O, Ito Y, et al. Risk factors for covered metallic stent migration in patients with distal malignant biliary obstruction due to pancreatic cancer. J Gastroenterol Hepatol. 2014;29:1744\u20139.","journal-title":"J Gastroenterol Hepatol"},{"key":"538_CR22","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1016\/j.gie.2010.09.039","volume":"73","author":"H Park do","year":"2011","unstructured":"do Park H, Lee SS, Lee TH, Ryu CH, Kim HJ, Seo DW, et al. Anchoring flap versus flared end, fully covered self-expandable metal stents to prevent migration in patients with benign biliary strictures: a multicenter, prospective, comparative pilot study (with videos). Gastrointest Endosc. 2011;73:64\u201370.","journal-title":"Gastrointest Endosc."},{"key":"538_CR23","doi-asserted-by":"crossref","first-page":"725","DOI":"10.5009\/gnl.2013.7.6.725","volume":"7","author":"H Isayama","year":"2013","unstructured":"Isayama H, Kawakubo K, Nakai Y, Inoue K, Gon C, Matsubara S, et al. A novel, fully covered laser-cut nitinol stent with antimigration properties for nonresectable distal malignant biliary obstruction: a multicenter feasibility study. Gut Liver. 2013;7:725\u201330.","journal-title":"Gut Liver"},{"key":"538_CR24","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1016\/j.gie.2012.02.039","volume":"76","author":"H Isayama","year":"2012","unstructured":"Isayama H, Mukai T, Itoi T, Maetani I, Nakai Y, Kawakami H, et al. Comparison of partially-covered nitinol stents with partially-covered stainless stents as a historical control by Japanese multicenter study in distal malignant biliary obstruction: WATCH study. Gastrointest Endosc. 2012;76:84\u201392.","journal-title":"Gastrointest Endosc"},{"key":"538_CR25","doi-asserted-by":"crossref","first-page":"1713","DOI":"10.1038\/ajg.2013.305","volume":"108","author":"M Kitano","year":"2013","unstructured":"Kitano M, Yamashita Y, Tanaka K, Konishi H, Yazumi S, Nakai Y, et al. Covered self-expandable metal stents with an anti-migration system improve patency duration without increased complications compared with uncovered stents for distal biliary obstruction caused by pancreatic carcinoma: a randomized multicenter trial. Am J Gastroenterol. 2013;108:1713\u201322.","journal-title":"Am J Gastroenterol"},{"key":"538_CR26","doi-asserted-by":"crossref","first-page":"729","DOI":"10.1136\/gut.2003.018945","volume":"53","author":"H Isayama","year":"2004","unstructured":"\u2022 Isayama H, Komatsu Y, Tsujino T, Sasahira N, Hirano K, Toda N, et al. A prospective randomized study of \u201ccovered\u201d versus \u201cuncovered\u201d diamond stents for the management of distal malignant biliary obstruction. Gut. 2004;53:729\u201334. This article is the first randomized controlled trial to show the superiority of covered metallic stent for the management of unresectable malignant distal biliary obstruction.","journal-title":"Gut"},{"key":"538_CR27","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1016\/j.gii.2015.03.002","volume":"4","author":"H Isayama","year":"2015","unstructured":"Isayama H, Nakai Y, Hamada T, Yamamoto N, Koike K. Development of an ideal self-expandable metallic stent design. Review article. Gastrointest Interv. 2015;4:46\u20139.","journal-title":"Gastrointest Interv"}],"container-title":["Current Gastroenterology Reports"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11894-016-0538-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11894-016-0538-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11894-016-0538-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,5,17]],"date-time":"2020-05-17T08:04:33Z","timestamp":1589702673000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11894-016-0538-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,10,24]]},"references-count":27,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2016,12]]}},"alternative-id":["538"],"URL":"https:\/\/doi.org\/10.1007\/s11894-016-0538-5","relation":{},"ISSN":["1522-8037","1534-312X"],"issn-type":[{"value":"1522-8037","type":"print"},{"value":"1534-312X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,10,24]]},"article-number":"64"}}