{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,31]],"date-time":"2026-10-31T15:19:15Z","timestamp":1793459955327,"version":"4.5.0"},"reference-count":50,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2022,4,9]],"date-time":"2022-04-09T00:00:00Z","timestamp":1649462400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,4,9]],"date-time":"2022-04-09T00:00:00Z","timestamp":1649462400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100002839","name":"Charit\u00e9 - Universit\u00e4tsmedizin Berlin","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100002839","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Curr Rheumatol Rep"],"published-print":{"date-parts":[[2022,6]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose of Review<\/jats:title>\n                <jats:p>Recent technical advances in computed tomography (CT) such as low-dose CT and dual-energy techniques open new applications for this imaging modality in clinical practice and for research purposes. This article will discuss the latest innovations and give a perspective on future developments.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Recent Findings<\/jats:title>\n                <jats:p>Low-dose CT has increasingly been used for assessing structural changes at the sacroiliac joints and the spine. It has developed into a method with similar or even lower radiation exposure than radiography while outperforming radiography for lesion detection. Despite being incompatible with low-dose scanning, some studies have shown that dual-energy CT can provide additional information that is otherwise only assessable with magnetic resonance imaging (MRI). However, it is unclear whether this additional information is reliable enough and if it would justify the additional radiation exposure, i.e. whether the performance of dual-energy CT is close enough to MRI to replace it in clinical practice.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Summary<\/jats:title>\n                <jats:p>While the role of dual-energy CT in patients with axial spondyloarthritis remains to be established, low-dose CT has developed to an appropriate modality that should replace radiography in many circumstances and might supplement MRI.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s11926-022-01075-5","type":"journal-article","created":{"date-parts":[[2022,4,9]],"date-time":"2022-04-09T10:02:50Z","timestamp":1649498570000},"page":"198-205","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":42,"title":["Future of Low-Dose Computed Tomography and Dual-Energy Computed Tomography in Axial Spondyloarthritis"],"prefix":"10.1007","volume":"24","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3593-1449","authenticated-orcid":false,"given":"Torsten","family":"Diekhoff","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kay Geert A.","family":"Hermann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert G.","family":"Lambert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,4,9]]},"reference":[{"issue":"5","key":"1075_CR1","first-page":"052109","volume":"8","author":"J Hsieh","year":"2021","unstructured":"Hsieh J, Flohr T. Computed tomography recent history and future perspectives. J Med Imaging (Bellingham). 2021;8(5):052109.","journal-title":"J Med Imaging (Bellingham)."},{"issue":"4","key":"1075_CR2","doi-asserted-by":"publisher","first-page":"384","DOI":"10.1007\/s11547-019-01126-5","volume":"125","author":"G Cicero","year":"2020","unstructured":"Cicero G, Ascenti G, Albrecht MH, Blandino A, Cavallaro M, D\u2019Angelo T, et al. Extra-abdominal dual-energy CT applications: a comprehensive overview. Radiol Med. 2020;125(4):384\u201397.","journal-title":"Radiol Med"},{"issue":"3","key":"1075_CR3","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1055\/a-1248-2556","volume":"193","author":"C Arndt","year":"2021","unstructured":"Arndt C, G\u00fcttler F, Heinrich A, B\u00fcrckenmeyer F, Diamantis I, Teichgr\u00e4ber U. Deep learning CT image reconstruction in clinical practice. Rofo. 2021;193(3):252\u201361.","journal-title":"Rofo"},{"key":"1075_CR4","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.28067","author":"MC Florkow","year":"2022","unstructured":"Florkow MC, Willemsen K, Mascarenhas VV, Oei EHG, van Stralen M, Seevinck PR. Magnetic resonance imaging versus computed tomography for three-dimensional bone imaging of musculoskeletal pathologies: A Review. J Magn Reson Imaging. 2022. https:\/\/doi.org\/10.1002\/jmri.28067.","journal-title":"J Magn Reson Imaging."},{"issue":"9","key":"1075_CR5","doi-asserted-by":"publisher","first-page":"6810","DOI":"10.1007\/s00330-021-07785-1","volume":"31","author":"MD Crema","year":"2021","unstructured":"Crema MD, Miquel A, Gouvion A, Phan C, Li L, Menu Y, et al. Improved detection of subchondral erosions in the sacroiliac joints with T1-weighted fat-suppressed MRI. Eur Radiol. 2021;31(9):6810\u20135.","journal-title":"Eur Radiol"},{"issue":"9","key":"1075_CR6","doi-asserted-by":"publisher","first-page":"1502","DOI":"10.1136\/annrheumdis-2016-210640","volume":"76","author":"T Diekhoff","year":"2017","unstructured":"Diekhoff T, Hermann KA, Greese J, Schwenke C, Poddubnyy D, Hamm B, et al. Comparison of MRI with radiography for detecting structural lesions of the sacroiliac joint using CT as standard of reference: results from the SIMACT study. Ann Rheum Dis. 2017;76(9):1502\u20138.","journal-title":"Ann Rheum Dis."},{"issue":"4","key":"1075_CR7","doi-asserted-by":"publisher","first-page":"326","DOI":"10.1097\/BOR.0000000000000803","volume":"33","author":"RGW Lambert","year":"2021","unstructured":"Lambert RGW, Hermann KGA, Diekhoff T. Low-dose computed tomography for axial spondyloarthritis: update on use and limitations. Curr Opin Rheumatol. 2021;33(4):326\u201332.","journal-title":"Curr Opin Rheumatol"},{"issue":"1126","key":"1075_CR8","doi-asserted-by":"publisher","first-page":"20210389","DOI":"10.1259\/bjr.20210389","volume":"94","author":"C Brower","year":"2021","unstructured":"Brower C, Rehani MM. Radiation risk issues in recurrent imaging. Br J Radiol. 2021;94(1126):20210389.","journal-title":"Br J Radiol"},{"issue":"6","key":"1075_CR9","doi-asserted-by":"publisher","first-page":"1167","DOI":"10.1016\/j.jpedsurg.2012.03.021","volume":"47","author":"C Calvert","year":"2012","unstructured":"Calvert C, Strauss KJ, Mooney DP. Variation in computed tomography radiation dose in community hospitals. J Pediatr Surg. 2012;47(6):1167\u20139.","journal-title":"J Pediatr Surg"},{"issue":"5","key":"1075_CR10","doi-asserted-by":"publisher","first-page":"1058","DOI":"10.2214\/AJR.18.19678","volume":"211","author":"BS Chahal","year":"2018","unstructured":"Chahal BS, Kwan ALC, Dhillon SS, Olubaniyi BO, Jhiangri GS, Neilson MM, et al. Radiation exposure to the sacroiliac joint from low-dose CT compared with radiography. AJR Am J Roentgenol. 2018;211(5):1058\u201362.","journal-title":"AJR Am J Roentgenol"},{"issue":"1060","key":"1075_CR11","doi-asserted-by":"publisher","first-page":"20150082","DOI":"10.1259\/bjr.20150082","volume":"89","author":"SN Patro","year":"2016","unstructured":"Patro SN, Chakraborty S, Sheikh A. The use of adaptive statistical iterative reconstruction (ASiR) technique in evaluation of patients with cervical spine trauma: impact on radiation dose reduction and image quality. Br J Radiol. 2016;89(1060):20150082.","journal-title":"Br J Radiol"},{"issue":"6","key":"1075_CR12","doi-asserted-by":"publisher","first-page":"815","DOI":"10.1097\/RCT.0000000000000128","volume":"38","author":"MJ Willemink","year":"2014","unstructured":"Willemink MJ, Takx RA, de Jong PA, Budde RP, Bleys RL, Das M, et al. Computed tomography radiation dose reduction: effect of different iterative reconstruction algorithms on image quality. J Comput Assist Tomogr. 2014;38(6):815\u201323.","journal-title":"J Comput Assist Tomogr"},{"issue":"1","key":"1075_CR13","doi-asserted-by":"publisher","first-page":"229","DOI":"10.21037\/qims-21-215","volume":"12","author":"J Greffier","year":"2022","unstructured":"Greffier J, Dabli D, Hamard A, Belaouni A, Akessoul P, Frandon J, et al. Effect of a new deep learning image reconstruction algorithm for abdominal computed tomography imaging on image quality and dose reduction compared with two iterative reconstruction algorithms: a phantom study. Quant Imaging Med Surg. 2022;12(1):229\u201343.","journal-title":"Quant Imaging Med Surg"},{"key":"1075_CR14","doi-asserted-by":"publisher","first-page":"658538","DOI":"10.3389\/fmed.2021.658538","volume":"8","author":"AP Caetano","year":"2021","unstructured":"Caetano AP, Mascarenhas VV, Machado PM. Axial spondyloarthritis: mimics and pitfalls of imaging assessment. Front Med (Lausanne). 2021;8:658538.","journal-title":"Front Med (Lausanne)."},{"issue":"4","key":"1075_CR15","doi-asserted-by":"publisher","first-page":"1295","DOI":"10.1007\/s10067-019-04824-7","volume":"39","author":"L Ye","year":"2020","unstructured":"Ye L, Liu Y, Xiao Q, Dong L, Wen C, Zhang Z, et al. MRI compared with low-dose CT scanning in the diagnosis of axial spondyloarthritis. Clin Rheumatol. 2020;39(4):1295\u2013303.","journal-title":"Clin Rheumatol"},{"issue":"2","key":"1075_CR16","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1136\/annrheumdis-2021-220136","volume":"81","author":"T Diekhoff","year":"2021","unstructured":"\u2022\u2022 Diekhoff T, Eshed I, Radny F, Ziegeler K, Proft F, Greese J, et al. Choose wisely: imaging for diagnosis of axial spondyloarthritis. Ann Rheum Dis. 2021;81(2):237\u201342. This study suggests that ldCT of the SIJ shows higher sensitivity than radiography and is more specific compared to both, MRI and X-ray in a near-clinical setting.","journal-title":"Ann Rheum Dis."},{"issue":"2","key":"1075_CR17","doi-asserted-by":"publisher","first-page":"99","DOI":"10.4103\/picr.PICR_41_18","volume":"9","author":"P Ranganathan","year":"2018","unstructured":"Ranganathan P, Aggarwal R. Understanding the properties of diagnostic tests - part 2: likelihood ratios. Perspect Clin Res. 2018;9(2):99\u2013102.","journal-title":"Perspect Clin Res"},{"issue":"1","key":"1075_CR18","doi-asserted-by":"publisher","first-page":"e001939","DOI":"10.1136\/rmdopen-2021-001939","volume":"8","author":"KGA Hermann","year":"2022","unstructured":"\u2022 Hermann KGA, Ziegeler K, Kreutzinger V, Poddubnyy D, Proft F, Deppe D, et al. What amount of structural damage defines sacroiliitis: a CT study. RMD Open. 2022;8(1):e001939. This study identifies erosion and ankylosis as most important findings in CT of the SIJ. It further provides evidence that erosion in mechanical load zones might also occur in degenerative joints or control patients.","journal-title":"RMD Open."},{"key":"1075_CR19","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1016\/j.media.2019.07.007","volume":"57","author":"Y Shenkman","year":"2019","unstructured":"Shenkman Y, Qutteineh B, Joskowicz L, Szeskin A, Yusef A, Mayer A, et al. Automatic detection and diagnosis of sacroiliitis in CT scans as incidental findings. Med Image Anal. 2019;57:165\u201375.","journal-title":"Med Image Anal"},{"key":"1075_CR20","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-021-08513-5","author":"Y Li","year":"2022","unstructured":"Li Y, Xiong Y, Hou B, Liu C, Wang J, Liu WV, Li X. Comparison of zero echo time MRI with T1-weighted fast spin echo for the recognition of sacroiliac joint structural lesions using CT as the reference standard. Eur Radiol. 2022. https:\/\/doi.org\/10.1007\/s00330-021-08513-5.","journal-title":"Eur Radiol."},{"issue":"2","key":"1075_CR21","doi-asserted-by":"publisher","first-page":"e001656","DOI":"10.1136\/rmdopen-2021-001656","volume":"7","author":"D Deppe","year":"2021","unstructured":"Deppe D, Hermann KG, Proft F, Poddubnyy D, Radny F, Protopopov M, et al. CT-like images of the sacroiliac joint generated from MRI using susceptibility-weighted imaging (SWI) in patients with axial spondyloarthritis. RMD Open. 2021;7(2):e001656.","journal-title":"RMD Open."},{"issue":"2","key":"1075_CR22","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1148\/radiol.2020201537","volume":"298","author":"LBO Jans","year":"2021","unstructured":"\u2022 Jans LBO, Chen M, Elewaut D, Van den Bosch F, Carron P, Jacques P, et al. MRI-based synthetic CT in the detection of structural lesions in patients with suspected sacroiliitis: comparison with MRI. Radiology. 2021;298(2):343\u20139. This study presents one of a few approaches for generating CT-like images from MRI data. It confirms that sensitivity and specificity for erosion, sclerosis and ankylosis can improve compared to standard MRI-sequences.","journal-title":"Radiology."},{"issue":"4","key":"1075_CR23","doi-asserted-by":"publisher","first-page":"2621","DOI":"10.1007\/s00330-020-07304-8","volume":"31","author":"A Hamard","year":"2021","unstructured":"Hamard A, Greffier J, Bastide S, Larbi A, Addala T, Sadate A, et al. Ultra-low-dose CT versus radiographs for minor spine and pelvis trauma: a Bayesian analysis of accuracy. Eur Radiol. 2021;31(4):2621\u201333.","journal-title":"Eur Radiol"},{"key":"1075_CR24","doi-asserted-by":"publisher","first-page":"216","DOI":"10.1016\/j.clinimag.2018.04.007","volume":"50","author":"SH Lee","year":"2018","unstructured":"Lee SH, Yun SJ, Jo HH, Song JG. Diagnosis of lumbar spinal fractures in emergency department: low-dose versus standard-dose CT using model-based iterative reconstruction. Clin Imaging. 2018;50:216\u201322.","journal-title":"Clin Imaging"},{"issue":"4","key":"1075_CR25","doi-asserted-by":"publisher","first-page":"618","DOI":"10.1016\/j.spinee.2020.10.027","volume":"21","author":"NG Shah","year":"2021","unstructured":"Shah NG, Keraliya A, Harris MB, Bono CM, Khurana B. Spinal trauma in DISH and AS: is MRI essential following the detection of vertebral fractures on CT? Spine J. 2021;21(4):618\u201326.","journal-title":"Spine J"},{"issue":"2","key":"1075_CR26","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1136\/annrheumdis-2017-211989","volume":"77","author":"A de Koning","year":"2018","unstructured":"de Koning A, de Bruin F, van den Berg R, Ramiro S, Baraliakos X, Braun J, et al. Low-dose CT detects more progression of bone formation in comparison to conventional radiography in patients with ankylosing spondylitis: results from the SIAS cohort. Ann Rheum Dis. 2018;77(2):293\u20139.","journal-title":"Ann Rheum Dis"},{"issue":"3","key":"1075_CR27","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1136\/annrheumdis-2017-212553","volume":"77","author":"F de Bruin","year":"2018","unstructured":"de Bruin F, de Koning A, van den Berg R, Baraliakos X, Braun J, Ramiro S, et al. Development of the CT syndesmophyte score (CTSS) in patients with ankylosing spondylitis: data from the SIAS cohort. Ann Rheum Dis. 2018;77(3):371\u20137.","journal-title":"Ann Rheum Dis"},{"issue":"12","key":"1075_CR28","doi-asserted-by":"publisher","first-page":"3776","DOI":"10.1093\/rheumatology\/keaa155","volume":"59","author":"R Stal","year":"2020","unstructured":"\u2022 Stal R, van Gaalen F, Sepriano A, Braun J, Reijnierse M, van den Berg R, et al. Facet joint ankylosis in r-axSpA: detection and 2-year progression on whole spine low-dose CT and comparison with syndesmophyte progression. Rheumatology (Oxford, England). 2020;59(12):3776\u201383. In this study, structural lesions of the facet joints were assessed with ldCT. It confirms that structural damage progression at the spine is better depicted by CT and by including facet joint changes.","journal-title":"Rheumatology (Oxford, England)."},{"issue":"5","key":"1075_CR29","doi-asserted-by":"publisher","first-page":"1005","DOI":"10.1016\/j.semarthrit.2021.07.015","volume":"51","author":"JY Jung","year":"2021","unstructured":"Jung JY, Kim MY, Hong YS, Park SH, Kang KY. Association between facet joint ankylosis and functional impairment in patients with radiographic axial spondyloarthritis. Semin Arthritis Rheum. 2021;51(5):1005\u201310.","journal-title":"Semin Arthritis Rheum"},{"issue":"2","key":"1075_CR30","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1016\/j.rdc.2020.01.010","volume":"46","author":"M Chen","year":"2020","unstructured":"Chen M, Bird P, Jans L. Emerging imaging techniques in spondyloarthritis: dual-energy computed tomography and new MRI sequences. Rheum Dis Clin North Am. 2020;46(2):287\u201396.","journal-title":"Rheum Dis Clin North Am"},{"key":"1075_CR31","doi-asserted-by":"publisher","DOI":"10.1007\/s00256-021-03979-2","author":"G Cheraya","year":"2022","unstructured":"Cheraya G, Sharma S, Chhabra A. Dual energy CT in musculoskeletal applications beyond crystal imaging: bone marrow maps and metal artifact reduction. Skeletal Radiol. 2022. https:\/\/doi.org\/10.1007\/s00256-021-03979-2.","journal-title":"Skeletal Radiol."},{"issue":"4","key":"1075_CR32","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1097\/RLI.0000000000000099","volume":"50","author":"T Diekhoff","year":"2015","unstructured":"Diekhoff T, Kiefer T, Stroux A, Pilhofer I, Juran R, Mews J, et al. Detection and characterization of crystal suspensions using single-source dual-energy computed tomography: a phantom model of crystal arthropathies. Invest Radiol. 2015;50(4):255\u201360.","journal-title":"Invest Radiol"},{"issue":"5","key":"1075_CR33","doi-asserted-by":"publisher","first-page":"707","DOI":"10.1007\/s00256-019-03343-5","volume":"49","author":"K Ziegeler","year":"2020","unstructured":"Ziegeler K, Hermann S, Hermann KGA, Hamm B, Diekhoff T. Dual-energy CT in the differentiation of crystal depositions of the wrist: does it have added value? Skeletal Radiol. 2020;49(5):707\u201313.","journal-title":"Skeletal Radiol"},{"issue":"4","key":"1075_CR34","doi-asserted-by":"publisher","first-page":"878","DOI":"10.2214\/AJR.12.9736","volume":"201","author":"A Srinivasan","year":"2013","unstructured":"Srinivasan A, Hoeffner E, Ibrahim M, Shah GV, LaMarca F, Mukherji SK. Utility of dual-energy CT virtual keV monochromatic series for the assessment of spinal transpedicular hardware-bone interface. AJR Am J Roentgenol. 2013;201(4):878\u201383.","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"1075_CR35","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1148\/radiol.2018181168","volume":"290","author":"H Wu","year":"2019","unstructured":"\u2022 Wu H, Zhang G, Shi L, Li X, Chen M, Huang X, et al. Axial spondyloarthritis: dual-energy virtual noncalcium CT in the detection of bone marrow edema in the sacroiliac joints. Radiology. 2019;290(1):157\u201364. This article first described DECT of the sacroiliac joints for bone marrow oedema detection. The diagnostic accuracy was reasonably high when excluding joints with sclerosis. However, the radiation exposure was beyond the levels of low-dose.","journal-title":"Radiology."},{"key":"1075_CR36","doi-asserted-by":"publisher","first-page":"110185","DOI":"10.1016\/j.ejrad.2022.110185","volume":"149","author":"JH Niehoff","year":"2022","unstructured":"Niehoff JH, Woeltjen MM, Saeed S, Michael AE, Boriesosdick J, Borggrefe J, et al. Assessment of hepatic steatosis based on virtual non-contrast computed tomography: initial experiences with a photon counting scanner approved for clinical use. Eur J Radiol. 2022;149:110185.","journal-title":"Eur J Radiol."},{"issue":"6","key":"1075_CR37","doi-asserted-by":"publisher","first-page":"3393","DOI":"10.1007\/s00330-020-06670-7","volume":"30","author":"M Chen","year":"2020","unstructured":"Chen M, Herregods N, Jaremko JL, Carron P, Elewaut D, Van den Bosch F, et al. Bone marrow edema in sacroiliitis: detection with dual-energy CT. Eur Radiol. 2020;30(6):3393\u2013400.","journal-title":"Eur Radiol"},{"issue":"3","key":"1075_CR38","doi-asserted-by":"publisher","first-page":"424","DOI":"10.3390\/tomography7030037","volume":"7","author":"G Foti","year":"2021","unstructured":"Foti G, Serra G, Iacono V, Zorzi C. Identification of traumatic bone marrow oedema: the pearls and pitfalls of dual-energy CT (DECT). Tomography. 2021;7(3):424\u201333.","journal-title":"Tomography"},{"issue":"1","key":"1075_CR39","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1007\/s00330-018-5568-y","volume":"29","author":"T Diekhoff","year":"2019","unstructured":"Diekhoff T, Engelhard N, Fuchs M, Pumberger M, Putzier M, Mews J, et al. Single-source dual-energy computed tomography for the assessment of bone marrow oedema in vertebral compression fractures: a prospective diagnostic accuracy study. Eur Radiol. 2019;29(1):31\u20139.","journal-title":"Eur Radiol"},{"issue":"2","key":"1075_CR40","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1007\/s00256-016-2533-1","volume":"46","author":"T Diekhoff","year":"2017","unstructured":"Diekhoff T, Scheel M, Hermann S, Mews J, Hamm B, Hermann KA. Osteitis: a retrospective feasibility study comparing single-source dual-energy CT to MRI in selected patients with suspected acute gout. Skeletal Radiol. 2017;46(2):185\u201390.","journal-title":"Skeletal Radiol"},{"issue":"6","key":"1075_CR41","doi-asserted-by":"publisher","first-page":"958","DOI":"10.1136\/annrheumdis-2018-213152","volume":"77","author":"L Jans","year":"2018","unstructured":"Jans L, De Kock I, Herregods N, Verstraete K, Van den Bosch F, Carron P, Oei EH, Elewaut D, Jacques P. Dual-energy CT: a new imaging modality for bone marrow oedema in rheumatoid arthritis. Ann Rheum Dis. 2018;77(6):958\u201360. https:\/\/doi.org\/10.1136\/annrheumdis-2018-213152.","journal-title":"Ann Rheum Dis."},{"key":"1075_CR42","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-021-08323-9","author":"LD Gruenewald","year":"2021","unstructured":"Gruenewald LD, Koch V, Martin SS, Yel I, Eichler K, Gruber-Rouh T, Lenga L, Wichmann JL, Alizadeh LS, Albrecht MH, Mader C, Huizinga NA, D\u2019Angelo T, Mazziotti S, Wesarg S, Vogl TJ, Booz C. Diagnostic accuracy of quantitative dual-energy CT-based volumetric bone mineral density assessment for the prediction of osteoporosis-associated fractures. Eur Radiol. 2021. https:\/\/doi.org\/10.1007\/s00330-021-08323-9.","journal-title":"Eur Radiol."},{"key":"1075_CR43","doi-asserted-by":"publisher","first-page":"109321","DOI":"10.1016\/j.ejrad.2020.109321","volume":"132","author":"C Booz","year":"2020","unstructured":"Booz C, Noeske J, Albrecht MH, Lenga L, Martin SS, Yel I, et al. Diagnostic accuracy of quantitative dual-energy CT-based bone mineral density assessment in comparison to Hounsfield unit measurements using dual x-ray absorptiometry as standard of reference. Eur J Radiol. 2020;132:109321.","journal-title":"Eur J Radiol."},{"issue":"12","key":"1075_CR44","doi-asserted-by":"publisher","first-page":"9221","DOI":"10.1007\/s00330-021-07989-5","volume":"31","author":"V Koch","year":"2021","unstructured":"Koch V, Yel I, Gr\u00fcnewald LD, Beckers S, Burck I, Lenga L, et al. Assessment of thoracic disk herniation by using virtual noncalcium dual-energy CT in comparison with standard grayscale CT. Eur Radiol. 2021;31(12):9221\u201331.","journal-title":"Eur Radiol"},{"issue":"2","key":"1075_CR45","doi-asserted-by":"publisher","first-page":"446","DOI":"10.1148\/radiol.2018181286","volume":"290","author":"C Booz","year":"2019","unstructured":"Booz C, N\u00f6ske J, Martin SS, Albrecht MH, Yel I, Lenga L, et al. Virtual noncalcium dual-energy CT: detection of lumbar disk herniation in comparison with standard Gray-scale CT. Radiology. 2019;290(2):446\u201355.","journal-title":"Radiology"},{"issue":"7","key":"1075_CR46","doi-asserted-by":"publisher","first-page":"1359","DOI":"10.1007\/s00256-020-03685-5","volume":"50","author":"F Sch\u00f6mig","year":"2021","unstructured":"Sch\u00f6mig F, Pumberger M, Palmowski Y, Ditges AK, Diekhoff T, G\u00f6hler F. Vertebral disk morphology of the lumbar spine: a retrospective analysis of collagen-sensitive mapping using dual-energy computed tomography. Skeletal Radiol. 2021;50(7):1359\u201367.","journal-title":"Skeletal Radiol"},{"issue":"8","key":"1075_CR47","doi-asserted-by":"publisher","first-page":"4495","DOI":"10.1007\/s00330-018-5963-4","volume":"29","author":"M Pumberger","year":"2019","unstructured":"Pumberger M, Fuchs M, Engelhard N, Hermann KG, Putzier M, Makowski MR, et al. Disk injury in patients with vertebral fractures-a prospective diagnostic accuracy study using dual-energy computed tomography. Eur Radiol. 2019;29(8):4495\u2013502.","journal-title":"Eur Radiol"},{"issue":"12","key":"1075_CR48","doi-asserted-by":"publisher","first-page":"9390","DOI":"10.1007\/s00330-021-08028-z","volume":"31","author":"J Pohlan","year":"2021","unstructured":"Pohlan J, Stelbrink C, Pumberger M, Deppe D, Sch\u00f6mig F, Hecht N, et al. Age-dependent microstructural changes of the intervertebral disc: a validation of proteoglycan-sensitive spectral CT. Eur Radiol. 2021;31(12):9390\u20138.","journal-title":"Eur Radiol"},{"key":"1075_CR49","doi-asserted-by":"publisher","first-page":"100383","DOI":"10.1016\/j.ejro.2021.100383","volume":"8","author":"S Ogiwara","year":"2021","unstructured":"Ogiwara S, Fukuda T, Kawakami R, Ojiri H, Fukuda K. Anatomical analysis of inflammation in hand psoriatic arthritis by dual-energy CT iodine map. Eur J Radiol Open. 2021;8:100383.","journal-title":"Eur J Radiol Open."},{"issue":"1","key":"1075_CR50","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1136\/annrheumdis-2018-213904","volume":"78","author":"T Diekhoff","year":"2019","unstructured":"Diekhoff T, Ulas ST, Poddubnyy D, Schneider U, Hermann S, Biesen R, et al. Ultra-low-dose CT detects synovitis in patients with suspected rheumatoid arthritis. Ann Rheum Dis. 2019;78(1):31\u20135.","journal-title":"Ann Rheum Dis"}],"container-title":["Current Rheumatology Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11926-022-01075-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11926-022-01075-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11926-022-01075-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,8,13]],"date-time":"2022-08-13T12:19:42Z","timestamp":1660393182000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11926-022-01075-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4,9]]},"references-count":50,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2022,6]]}},"alternative-id":["1075"],"URL":"https:\/\/doi.org\/10.1007\/s11926-022-01075-5","relation":{},"ISSN":["1523-3774","1534-6307"],"issn-type":[{"value":"1523-3774","type":"print"},{"value":"1534-6307","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,4,9]]},"assertion":[{"value":"22 March 2022","order":1,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 April 2022","order":2,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 August 2022","order":3,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Update","order":4,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Missing Open Access funding information has been added in the Funding Note.","order":5,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"TD declares grants from the Berlin Institute of Health and Canon Medical Systems and consulting fees from Eli Lilly and lecture fees from Novartis, MSD and Canon Medical Systems. KGH reports consulting fees from Calyx and AbbVie and lecture fees from Novartis, MSD and Pfizer; he is co-founder of BerlinFlame GmbH. RGL reports consulting fees by Calyx, CARE Arthritis and Image Analysis Group and lecture fees from CARE Arthritis.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of Interest"}},{"value":"This article does not contain any studies with human or animal subjects performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Human and Animal Rights and Informed Consent"}}]}}