{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T03:25:43Z","timestamp":1786937143961,"version":"build-2736575974"},"reference-count":67,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T00:00:00Z","timestamp":1786924800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T00:00:00Z","timestamp":1786924800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Curr Urol Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose of review<\/jats:title>\n                    <jats:p>To examine the evidence on contemporary lasers and provide a practical framework for platform selection, parameter optimization, and thermal safety based on the principles of smart lithotripsy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Recent findings<\/jats:title>\n                    <jats:p>Holmium: yttrium-aluminum-garnet (Ho:YAG) remains versatile for fragmentation and dusting, whereas thulium fiber laser (TFL) provides efficient fine-particle dusting with limited retropulsion. Pulsed thulium: YAG (p-Tm:YAG) shows an intermediate profile between Ho:YAG and TFL, but clinical evidence on lithotripsy outcomes is limited. Higher power settings with Ho:YAG may accelerate ablation, but have to be used carefully with high flow rates and access sheaths. For TFL, high-power settings have not been shown to shorten operative time or improve stone-free outcomes and may increase thermal risk. Future systems may incorporate stone recognition, composition prediction, and tissue protection.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Summary<\/jats:title>\n                    <jats:p>There is no ideal laser for every clinical scenario. Urologists should match the platform, settings, and treatment strategy to the intended endpoint, whether fragmentation with active extraction or dusting with passive clearance.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s11934-026-01354-z","type":"journal-article","created":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T01:45:53Z","timestamp":1786931153000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Smart Lithotripsy: Lasers, Energy Sources and Efficiency"],"prefix":"10.1007","volume":"27","author":[{"ORCID":"https:\/\/orcid.org\/0009-0001-7905-4356","authenticated-orcid":false,"given":"Gantapong","family":"Sainont","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Uy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pankaj N","family":"Maheshwari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hsiang Ying","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniele","family":"Castellani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yasser A.","family":"Noureldin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brett A.","family":"Johnson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Horacio","family":"Sanguinetti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Khurshid R.","family":"Ghani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"name":"from the Office of Research FUTURE Collaborative of the Endourological Society","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,8,17]]},"reference":[{"key":"1354_CR1","doi-asserted-by":"publisher","first-page":"57","DOI":"10.3389\/fsurg.2017.00057","volume":"4","author":"AH Aldoukhi","year":"2017","unstructured":"Aldoukhi AH, Roberts WW, Hall TL, Ghani KR. Holmium Laser Lithotripsy in the New Stone Age: Dust or Bust? Front Surg. 2017;4:57.","journal-title":"Front Surg"},{"issue":"4","key":"1354_CR2","doi-asserted-by":"publisher","first-page":"290","DOI":"10.1089\/end.2017.0220","volume":"32","author":"J Tracey","year":"2018","unstructured":"Tracey J, Gagin G, Morhardt D, Hollingsworth J, Ghani KR. Ureteroscopic High-Frequency Dusting Utilizing a 120-W Holmium Laser. J Endourol. 2018;32(4):290\u20135.","journal-title":"J Endourol"},{"issue":"3","key":"1354_CR3","doi-asserted-by":"publisher","first-page":"278","DOI":"10.1002\/(SICI)1096-9101(1996)18:3<278::AID-LSM10>3.0.CO;2-2","volume":"18","author":"ED Jansen","year":"1996","unstructured":"Jansen ED, Asshauer T, Frenz M, Motamedi M, Delacr\u00e9taz G, Welch AJ. Effect of pulse duration on bubble formation and laser-induced pressure waves during holmium laser ablation. Lasers Surg Med. 1996;18(3):278\u201393.","journal-title":"Lasers Surg Med"},{"issue":"10","key":"1354_CR4","doi-asserted-by":"publisher","first-page":"1240","DOI":"10.1002\/jbio.201600010","volume":"10","author":"LA Hardy","year":"2017","unstructured":"Hardy LA, Kennedy JD, Wilson CR, Irby PB, Fried NM. Analysis of thulium fiber laser induced bubble dynamics for ablation of kidney stones. J Biophotonics. 2017;10(10):1240\u20139.","journal-title":"J Biophotonics"},{"issue":"8","key":"1354_CR5","doi-asserted-by":"publisher","first-page":"1883","DOI":"10.1007\/s00345-019-02654-5","volume":"38","author":"O Traxer","year":"2020","unstructured":"Traxer O, Keller EX. Thulium fiber laser: the new player for kidney stone treatment? A comparison with Holmium:YAG laser. World J Urol. 2020;38(8):1883\u201394.","journal-title":"World J Urol"},{"issue":"1","key":"1354_CR6","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1097\/MOU.0000000000001351","volume":"36","author":"D Robesti","year":"2026","unstructured":"Robesti D, La Rezza S, Traxer O, Kartalas Goumas I, Ventimiglia E. All about pulsed thulium:YAG laser: a systematic review from YAU Endourology and EAU Endourology. Curr Opin Urol. 2026;36(1):57\u201365.","journal-title":"Curr Opin Urol"},{"issue":"3","key":"1354_CR7","doi-asserted-by":"publisher","first-page":"555","DOI":"10.1364\/AO.12.000555","volume":"12","author":"GM Hale","year":"1973","unstructured":"Hale GM, Querry MR. Optical Constants of Water in the 200-nm to 200-microm Wavelength Region. Appl Opt. 1973;12(3):555\u201363.","journal-title":"Appl Opt"},{"issue":"3","key":"1354_CR8","doi-asserted-by":"publisher","first-page":"258","DOI":"10.1002\/lsm.1900140308","volume":"14","author":"ED Jansen","year":"1994","unstructured":"Jansen ED, van Leeuwen TG, Motamedi M, Borst C, Welch AJ. Temperature dependence of the absorption coefficient of water for midinfrared laser radiation. Lasers Surg Med. 1994;14(3):258\u201368.","journal-title":"Lasers Surg Med"},{"issue":"1","key":"1354_CR9","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1111\/bju.15079","volume":"126","author":"E Ventimiglia","year":"2020","unstructured":"Ventimiglia E, Doizi S, Kovalenko A, Andreeva V, Traxer O. Effect of temporal pulse shape on urinary stone phantom retropulsion rate and ablation efficiency using holmium:YAG and super-pulse thulium fibre lasers. BJU Int. 2020;126(1):159\u201367.","journal-title":"BJU Int"},{"issue":"2","key":"1354_CR10","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1089\/end.2018.0572","volume":"33","author":"AH Aldoukhi","year":"2019","unstructured":"Aldoukhi AH, Roberts WW, Hall TL, Ghani KR. Watch Your Distance: The Role of Laser Fiber Working Distance on Fragmentation When Altering Pulse Width or Modulation. J Endourol. 2019;33(2):120\u20136.","journal-title":"J Endourol"},{"issue":"4","key":"1354_CR11","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1007\/s00345-014-1429-8","volume":"33","author":"MJ Bader","year":"2015","unstructured":"Bader MJ, Pongratz T, Khoder W, Stief CG, Herrmann T, Nagele U, Sroka R. Impact of pulse duration on Ho:YAG laser lithotripsy: fragmentation and dusting performance. World J Urol. 2015;33(4):471\u20137.","journal-title":"World J Urol"},{"key":"1354_CR12","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1016\/j.urology.2017.01.007","volume":"103","author":"DA Wollin","year":"2017","unstructured":"Wollin DA, Ackerman A, Yang C, Chen T, Simmons WN, Preminger GM, Lipkin ME. Variable Pulse Duration From a New Holmium:YAG Laser: The Effect on Stone Comminution, Fiber Tip Degradation, and Retropulsion in a Dusting Model. Urology. 2017;103:47\u201351.","journal-title":"Urology"},{"issue":"1","key":"1354_CR13","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1016\/j.ajur.2014.08.008","volume":"1","author":"C Netsch","year":"2014","unstructured":"Netsch C, Knipper S, Tiburtius C, Gross AJ. Systematic evaluation of a holmium:yttrium-aluminum-garnet laser lithotripsy device with variable pulse peak power and pulse duration. Asian J Urol. 2014;1(1):60\u20135.","journal-title":"Asian J Urol"},{"issue":"1","key":"1354_CR14","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1007\/s00240-025-01714-3","volume":"53","author":"R Marom","year":"2025","unstructured":"Marom R, Glienke L, Robinson JW, Hall TL, Roberts WW, Ghani KR. Characterizing stone ablation with the thulium fiber laser: a single-pulse comparison of different pulse durations. Urolithiasis. 2025;53(1):42.","journal-title":"Urolithiasis"},{"issue":"21","key":"1354_CR15","doi-asserted-by":"publisher","first-page":"7480","DOI":"10.3390\/app10217480","volume":"10","author":"V Lekarev","year":"2020","unstructured":"Lekarev V, Dymov A, Vinarov A, Sorokin N, Minaev V, Minaev N, et al. Mechanism of Lithotripsy by Superpulse Thulium Fiber Laser and Its Clinical Efficiency. Appl Sci [Internet]. 2020;10(21):7480.","journal-title":"Appl Sci [Internet]"},{"issue":"2","key":"1354_CR16","doi-asserted-by":"publisher","first-page":"497","DOI":"10.1007\/s00345-019-02785-9","volume":"38","author":"V Andreeva","year":"2020","unstructured":"Andreeva V, Vinarov A, Yaroslavsky I, Kovalenko A, Vybornov A, Rapoport L, et al. Preclinical comparison of superpulse thulium fiber laser and a holmium:YAG laser for lithotripsy. World J Urol. 2020;38(2):497\u2013503.","journal-title":"World J Urol"},{"issue":"12","key":"1354_CR17","doi-asserted-by":"publisher","first-page":"1427","DOI":"10.1089\/end.2024.0424","volume":"38","author":"M Chicaud","year":"2024","unstructured":"Chicaud M, Kutchukian S, Berthe L, Corrales M, Solano C, Candela L, et al. In Vitro Comparison of Pulsed-Thulium:YAG, Holmium:YAG, and Thulium Fiber Laser. J Endourol. 2024;38(12):1427\u201335.","journal-title":"J Endourol"},{"issue":"1","key":"1354_CR18","doi-asserted-by":"publisher","first-page":"366","DOI":"10.1007\/s00345-025-05703-4","volume":"43","author":"S Moretto","year":"2025","unstructured":"Moretto S, Madden A, Quar\u00e0 A, Zorzi F, Bravo-Balado A, Jannello LMI, et al. In vitro evaluation of pulse profile, peak power, and fiber safety of the new diode-pumped RevoLix HTL Tm: YAG laser. World J Urol. 2025;43(1):366.","journal-title":"World J Urol"},{"issue":"10","key":"1354_CR19","doi-asserted-by":"publisher","first-page":"2823","DOI":"10.1007\/s00345-023-04549-y","volume":"41","author":"JL Kwok","year":"2023","unstructured":"Kwok JL, Ventimiglia E, De Coninck V, Corrales M, Sierra A, Panthier F, et al. Pulsed thulium:YAG laser-ready to dust all urinary stone composition types? Results from a PEARLS analysis. World J Urol. 2023;41(10):2823\u201331.","journal-title":"World J Urol"},{"key":"1354_CR20","unstructured":"OmniGuide. RevoLix HTL instructions for use: OmniGuide. 2022. Available from: https:\/\/www.omni-guide.com\/wp-content\/uploads\/2024\/04\/IFU_035052011GA_RevoLixHTL_en_USA.pdf"},{"issue":"8","key":"1354_CR21","doi-asserted-by":"publisher","first-page":"914","DOI":"10.1089\/end.2023.0168","volume":"37","author":"F Soto-Palou","year":"2023","unstructured":"Soto-Palou F, Chen J, Medairos R, Zhong P, Antonelli J, Preminger GM, Lipkin ME. In Pursuit of the Optimal Dusting Settings with the Thulium Fiber Laser: An In Vitro Assessment. J Endourol. 2023;37(8):914\u201320.","journal-title":"J Endourol"},{"issue":"3","key":"1354_CR22","doi-asserted-by":"publisher","first-page":"445","DOI":"10.1097\/JU.0000000000003833","volume":"211","author":"J Johnson","year":"2024","unstructured":"Johnson J, Lee J, Movassaghi M, Han D, Pingle SR, Williams J, et al. Comparative Analyses and Ablation Efficiency of Thulium Fiber Laser by Stone Composition. J Urol. 2024;211(3):445\u201354.","journal-title":"J Urol"},{"issue":"8","key":"1354_CR23","doi-asserted-by":"publisher","first-page":"1211","DOI":"10.1089\/end.2020.1116","volume":"35","author":"M Liu","year":"2021","unstructured":"Liu M, Peng Y, Wang Z, Li L, Ming S, Fang Z, et al. Ablation Efficiency of a Novel Thulium Fiber Laser: An In Vitro Study on Laser Setting and Fiber Usage. J Endourol. 2021;35(8):1211\u20136.","journal-title":"J Endourol"},{"issue":"1","key":"1354_CR24","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1007\/s00240-023-01501-y","volume":"51","author":"J Chen","year":"2023","unstructured":"Chen J, Mishra A, Medairos R, Antonelli J, Preminger GM, Lipkin ME, Zhong P. In vitro investigation of stone ablation efficiency, char formation, spark generation, and damage mechanism produced by thulium fiber laser. Urolithiasis. 2023;51(1):124.","journal-title":"Urolithiasis"},{"issue":"1","key":"1354_CR25","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1007\/s00240-024-01585-0","volume":"52","author":"Z Li","year":"2024","unstructured":"Li Z, Wu S, Liu T, Li S, Wang X. Optimal parameter settings of thulium fiber laser for ureteral stone lithotripsy: a comparative study in two different testing environments. Urolithiasis. 2024;52(1):78.","journal-title":"Urolithiasis"},{"issue":"2","key":"1354_CR26","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1111\/bju.16218","volume":"133","author":"A Mishra","year":"2024","unstructured":"Mishra A, Medairos R, Chen J, Soto-Palou F, Wu Y, Antonelli J, et al. Exploring optimal settings for safe and effective thulium fibre laser lithotripsy in a kidney model. BJU Int. 2024;133(2):223\u201330.","journal-title":"BJU Int"},{"issue":"12","key":"1354_CR27","doi-asserted-by":"publisher","first-page":"4037","DOI":"10.1007\/s11255-025-04584-1","volume":"57","author":"Y Liao","year":"2025","unstructured":"Liao Y, Zha R, Mei X, Wang C, Li Z, Wang H, et al. Exploring the influence of laser parameters on retropulsion and ablation rate in thulium fiber laser lithotripsy: an in vitro study. Int Urol Nephrol. 2025;57(12):4037\u201347.","journal-title":"Int Urol Nephrol"},{"key":"1354_CR28","doi-asserted-by":"crossref","unstructured":"Zha R, Wang C, Liao Y, Li Z, Li S, Wang H et al. Optimal thulium fiber laser parameters for non-impacted stone lithotripsy: an in-vitro and ex-vivo evaluation. Urolithiasis. 2026;54:63.","DOI":"10.1007\/s00240-026-01964-9"},{"issue":"3","key":"1354_CR29","doi-asserted-by":"publisher","first-page":"485","DOI":"10.1111\/bju.70123","volume":"137","author":"MS \u00c6s\u00f8y","year":"2026","unstructured":"\u00c6s\u00f8y MS, Julieb\u00f8-Jones P, Gjengst\u00f8 P, Beisland C, Ulvik \u00d8. Watt\u2019s the difference? A randomised trial of high- vs low-power ureteroscopic thulium fibre laser lithotripsy. BJU Int. 2026;137(3):485\u201392.","journal-title":"BJU Int"},{"issue":"4","key":"1354_CR30","doi-asserted-by":"publisher","first-page":"e70182","DOI":"10.1002\/bco2.70182","volume":"7","author":"MS \u00c6s\u00f8y","year":"2026","unstructured":"\u00c6s\u00f8y MS, Beisland C, Ulvik \u00d8. Power is not performance: Analysis of laser-use metrics from a randomised clinical trial comparing low- and high-power ureteroscopic lithotripsy. BJUI Compass. 2026;7(4):e70182.","journal-title":"BJUI Compass"},{"issue":"2","key":"1354_CR31","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1111\/bju.12567","volume":"114","author":"P Kronenberg","year":"2014","unstructured":"Kronenberg P, Traxer O. In vitro fragmentation efficiency of holmium: yttrium-aluminum-garnet (YAG) laser lithotripsy\u2013a comprehensive study encompassing different frequencies, pulse energies, total power levels and laser fibre diameters. BJU Int. 2014;114(2):261\u20137.","journal-title":"BJU Int"},{"issue":"3","key":"1354_CR32","doi-asserted-by":"publisher","first-page":"914","DOI":"10.1016\/j.juro.2011.10.147","volume":"187","author":"J Sea","year":"2012","unstructured":"Sea J, Jonat LM, Chew BH, Qiu J, Wang B, Hoopman J, et al. Optimal power settings for Holmium:YAG lithotripsy. J Urol. 2012;187(3):914\u20139.","journal-title":"J Urol"},{"issue":"10","key":"1354_CR33","doi-asserted-by":"publisher","first-page":"1075","DOI":"10.1089\/end.2020.0149","volume":"34","author":"AH Aldoukhi","year":"2020","unstructured":"Aldoukhi AH, Black KM, Hall TL, Roberts WW, Ghani KR. Frequency Threshold for Ablation During Holmium Laser Lithotripsy: How High Can You Go? J Endourol. 2020;34(10):1075\u201381.","journal-title":"J Endourol"},{"issue":"2","key":"1354_CR34","doi-asserted-by":"publisher","first-page":"442","DOI":"10.1016\/j.urology.2012.11.021","volume":"81","author":"SL Hecht","year":"2013","unstructured":"Hecht SL, Wolf JS. Jr. Techniques for holmium laser lithotripsy of intrarenal calculi. Urology. 2013;81(2):442\u20135.","journal-title":"Urology"},{"key":"1354_CR35","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1016\/j.urology.2018.08.031","volume":"122","author":"AH Aldoukhi","year":"2018","unstructured":"Aldoukhi AH, Roberts WW, Hall TL, Teichman JMH, Ghani KR. Understanding the Popcorn Effect During Holmium Laser Lithotripsy for Dusting. Urology. 2018;122:52\u20137.","journal-title":"Urology"},{"issue":"4","key":"1354_CR36","doi-asserted-by":"publisher","first-page":"645","DOI":"10.1089\/end.2007.9843","volume":"22","author":"SN Chawla","year":"2008","unstructured":"Chawla SN, Chang MF, Chang A, Lenoir J, Bagley DH. Effectiveness of high-frequency holmium:YAG laser stone fragmentation: the popcorn effect. J Endourol. 2008;22(4):645\u201350.","journal-title":"J Endourol"},{"issue":"4","key":"1354_CR37","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1007\/s00240-018-1066-6","volume":"47","author":"DA Wollin","year":"2019","unstructured":"Wollin DA, Tom WR, Jiang R, Simmons WN, Preminger GM, Lipkin ME. An in vitro evaluation of laser settings and location in the efficiency of the popcorn effect. Urolithiasis. 2019;47(4):377\u201382.","journal-title":"Urolithiasis"},{"issue":"6","key":"1354_CR38","doi-asserted-by":"publisher","first-page":"1699","DOI":"10.1007\/s00345-020-03282-0","volume":"39","author":"KM Black","year":"2021","unstructured":"Black KM, Aldoukhi AH, Teichman JMH, Majdalany SE, Hall TL, Roberts WW, Ghani KR. Pulse modulation with Moses technology improves popcorn laser lithotripsy. World J Urol. 2021;39(6):1699\u2013705.","journal-title":"World J Urol"},{"issue":"3","key":"1354_CR39","doi-asserted-by":"publisher","first-page":"702","DOI":"10.1016\/j.juro.2017.02.3371","volume":"198","author":"E Emiliani","year":"2017","unstructured":"Emiliani E, Talso M, Cho SY, Baghdadi M, Mahmoud S, Pinheiro H, Traxer O. Optimal Settings for the Noncontact Holmium:YAG Stone Fragmentation Popcorn Technique. J Urol. 2017;198(3):702\u20136.","journal-title":"J Urol"},{"issue":"6","key":"1354_CR40","doi-asserted-by":"publisher","first-page":"598","DOI":"10.1089\/end.2017.0050","volume":"31","author":"MM Elhilali","year":"2017","unstructured":"Elhilali MM, Badaan S, Ibrahim A, Andonian S. Use of the Moses Technology to Improve Holmium Laser Lithotripsy Outcomes: A Preclinical Study. J Endourol. 2017;31(6):598\u2013604.","journal-title":"J Endourol"},{"key":"1354_CR41","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1016\/j.urology.2024.12.032","volume":"196","author":"K Tominaga","year":"2025","unstructured":"Tominaga K, Inoue T, Usuda T, Ketsuwan C. Optimizing the Appropriate Mode of the Pulse-modulated Holmium Laser in a Pop-dusting Benchtop Model. Urology. 2025;196:75\u201381.","journal-title":"Urology"},{"issue":"12","key":"1354_CR42","doi-asserted-by":"publisher","first-page":"1131","DOI":"10.1089\/end.2018.0660","volume":"32","author":"B Winship","year":"2018","unstructured":"Winship B, Wollin D, Carlos E, Li J, Peters C, Simmons WN, et al. Dusting Efficiency of the Moses Holmium Laser: An Automated In Vitro Assessment. J Endourol. 2018;32(12):1131\u20135.","journal-title":"J Endourol"},{"issue":"3","key":"1354_CR43","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1089\/end.2020.0585","volume":"35","author":"JH Chung","year":"2021","unstructured":"Chung JH, Baek M, Park SS, Han DH. The Feasibility of Pop-Dusting Using High-Power Laser (2 J \u00d7 50 Hz) in Retrograde Intrarenal Surgery for Renal Stones: Retrospective Single-Center Experience. J Endourol. 2021;35(3):279\u201384.","journal-title":"J Endourol"},{"issue":"1","key":"1354_CR44","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1007\/s00240-021-01282-2","volume":"50","author":"D Peretti","year":"2022","unstructured":"Peretti D, Dalmasso E, Pecoraro A, Ambruosi C, Venzano F, Fiori C, et al. Low-energy high-frequency Ho-YAG lithotripsy: is RIRS going forward? A case-control study. Urolithiasis. 2022;50(1):79\u201385.","journal-title":"Urolithiasis"},{"key":"1354_CR45","doi-asserted-by":"publisher","unstructured":"Inoue T, Hamamoto S, Okada S, Yamamichi F, Fujita M, Tominaga K et al. Single-session impact of high-power laser with Moses technology for lower pole stones in retrograde intrarenal surgery: retrospective study. J Clin Med. 2022;12(1):301. https:\/\/doi.org\/10.3390\/jcm12010301.","DOI":"10.3390\/jcm12010301"},{"issue":"2","key":"1354_CR46","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1111\/bju.70083","volume":"137","author":"A Folcia","year":"2026","unstructured":"Folcia A, Perri D, Villa L, Albanese N, Robesti D, Corsini C, et al. In vitro comparison of stone retropulsion between the new holmium:yttrium aluminium garnet laser generator with a very low peak power pulse modulation mode (Magneto technology) and the thulium fibre laser. BJU Int. 2026;137(2):306\u201311.","journal-title":"BJU Int"},{"issue":"7","key":"1354_CR47","doi-asserted-by":"publisher","first-page":"1051","DOI":"10.1089\/end.2020.0526","volume":"35","author":"R Petzold","year":"2021","unstructured":"Petzold R, Suarez-Ibarrola R, Miernik A. Gas Bubble Anatomy During Laser Lithotripsy: An Experimental In Vitro Study of a Pulsed Solid-State Tm:YAG and Ho:YAG Device. J Endourol. 2021;35(7):1051\u20137.","journal-title":"J Endourol"},{"issue":"9","key":"1354_CR48","doi-asserted-by":"publisher","first-page":"3651","DOI":"10.1007\/s00345-021-03668-8","volume":"39","author":"R Petzold","year":"2021","unstructured":"Petzold R, Miernik A, Suarez-Ibarrola R. Retropulsion force in laser lithotripsy-an in vitro study comparing a Holmium device to a novel pulsed solid-state Thulium laser. World J Urol. 2021;39(9):3651\u20136.","journal-title":"World J Urol"},{"issue":"1","key":"1354_CR49","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1007\/s10103-024-04267-w","volume":"39","author":"F Panthier","year":"2024","unstructured":"Panthier F, Solano C, Chicaud M, Kutchukian S, Candela L, Doizi S, et al. Thulium fiber laser versus pulsed Thulium:YAG for laser lithotripsy during flexible ureteroscopy. Lasers Med Sci. 2024;39(1):294.","journal-title":"Lasers Med Sci"},{"key":"1354_CR50","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1016\/j.urology.2025.01.065","volume":"199","author":"D Castellani","year":"2025","unstructured":"Castellani D, Fong KY, Traxer O, Malkhasyan V, Gadzhiev N, Ragoori D, et al. Propensity Score Matched Analysis of Thulium Fiber vs Pulsed Thulium:Yttrium Aluminum Garnet Laser Lithotripsy in Flexible Ureteroscopy for Kidney Stone Disease Using a Flexible and Navigable Suction Ureteral Access Sheath: Results From a Prospective, Multicenter Study of the EAU Section of Endourology. Urology. 2025;199:47\u201353.","journal-title":"Urology"},{"issue":"1","key":"1354_CR51","doi-asserted-by":"publisher","first-page":"30","DOI":"10.5173\/ceju.2025.0044","volume":"79","author":"JA Salvad\u00f3","year":"2026","unstructured":"Salvad\u00f3 JA, Villena JM, Urrea F, Marchant P, Larra\u00f1aga M, Cabello JM, Marchetti P. High-power holmium laser versus pulsed thulium laser for ureteroscopic lithotripsy: Results of a randomized prospective study. Cent Eur J Urol. 2026;79(1):30\u20135.","journal-title":"Cent Eur J Urol"},{"issue":"1","key":"1354_CR52","doi-asserted-by":"publisher","first-page":"685","DOI":"10.1007\/s00345-025-06001-9","volume":"43","author":"A Quar\u00e0","year":"2025","unstructured":"Quar\u00e0 A, Bravo-Balado A, Moretto S, Madden A, Zorzi F, Jannello LMI, et al. In vitro ablation rates of Ho:YAG, p-Tm:YAG and TFL lasers. World J Urol. 2025;43(1):685.","journal-title":"World J Urol"},{"issue":"11","key":"1354_CR53","doi-asserted-by":"publisher","first-page":"1209","DOI":"10.1089\/end.2024.0349","volume":"38","author":"A Sierra","year":"2024","unstructured":"Sierra A, Panthier F, Castillo E, Mercad\u00e9 A, Peri L, Alcaraz A, et al. Assessment of Holmium:YAG, Pulsed-Thulium:YAG and Thulium Fiber Lasers for Urinary Stone Ablation. In Vitro Study. J Endourol. 2024;38(11):1209\u201316.","journal-title":"J Endourol"},{"issue":"1","key":"1354_CR54","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1007\/s00240-025-01866-2","volume":"53","author":"S Moretto","year":"2025","unstructured":"Moretto S, Madden A, Quar\u00e0 A, Zorzi F, Bravo-Balado A, Jannello LMI, et al. In vitro comparative analysis of ablation volume and energy requirements for 1\u00a0mm\u00b3 stone ablation using ho: YAG, p-Tm: YAG, and TFL lasers. Urolithiasis. 2025;53(1):194.","journal-title":"Urolithiasis"},{"issue":"8","key":"1354_CR55","doi-asserted-by":"publisher","first-page":"e70067","DOI":"10.1002\/bco2.70067","volume":"6","author":"F Panthier","year":"2025","unstructured":"Panthier F, Sierra A, Keller EX, Chicaud M, Ventimiglia E, Kwok JL, et al. Comparison of p-Tm:YAG, TFL and Ho:YAG\u2019s in vitro ablation rates on synthetic and human stones. BJUI Compass. 2025;6(8):e70067.","journal-title":"BJUI Compass"},{"issue":"12","key":"1354_CR56","doi-asserted-by":"publisher","first-page":"1308","DOI":"10.1089\/end.2017.0679","volume":"31","author":"AH Aldoukhi","year":"2017","unstructured":"Aldoukhi AH, Ghani KR, Hall TL, Roberts WW. Thermal Response to High-Power Holmium Laser Lithotripsy. J Endourol. 2017;31(12):1308\u201312.","journal-title":"J Endourol"},{"issue":"1","key":"1354_CR57","doi-asserted-by":"publisher","first-page":"453","DOI":"10.1007\/s00345-024-05162-3","volume":"42","author":"E Ventimiglia","year":"2024","unstructured":"Ventimiglia E, Robesti D, Keller EX, Corsini C, Folcia A, Fantin M, et al. Temperature profile during endourological laser activation: introducing the thermal safety distance concept. World J Urol. 2024;42(1):453.","journal-title":"World J Urol"},{"issue":"11","key":"1354_CR58","doi-asserted-by":"publisher","first-page":"1158","DOI":"10.1177\/08927790251377787","volume":"39","author":"EC Riedinger","year":"2025","unstructured":"Riedinger EC, Mohaghegh M, Leshchenko V, Posid T, Katta N, Milner TE, et al. Thulium Fiber Laser: Long Pulse Width as an Independent Risk Factor for Excessive Heat Generation. J Endourol. 2025;39(11):1158\u201364.","journal-title":"J Endourol"},{"issue":"7","key":"1354_CR59","doi-asserted-by":"publisher","first-page":"698","DOI":"10.1089\/end.2024.0637","volume":"39","author":"A Mishra","year":"2025","unstructured":"Mishra A, Margolin EJ, Stewart AW, Medairos RE, Antonelli J, Preminger GM, et al. Optimizing Fragmentation while Minimizing Thermal Injury Risk with the Thulium Fiber Laser in Ureteral Stone Lithotripsy: An In Vitro Study. J Endourol. 2025;39(7):698\u2013707.","journal-title":"J Endourol"},{"issue":"1","key":"1354_CR60","first-page":"17","volume":"40","author":"K Gupta","year":"2026","unstructured":"Gupta K, Connors C, Savin Z, Lundon D, Khargi R, Durbhakula V, et al. Laser Lithotripsy Induces Dose-Dependent Temperature Elevation During Retrograde Intrarenal Surgery. J Endourol. 2026;40(1):17\u201325.","journal-title":"J Endourol"},{"issue":"8","key":"1354_CR61","doi-asserted-by":"publisher","first-page":"1217","DOI":"10.1089\/end.2020.1067","volume":"35","author":"AH Aldoukhi","year":"2021","unstructured":"Aldoukhi AH, Dau JJ, Majdalany SE, Hall TL, Ghani KR, Hollingsworth JM, et al. Patterns of Laser Activation During Ureteroscopic Lithotripsy: Effects on Caliceal Fluid Temperature and Thermal Dose. J Endourol. 2021;35(8):1217\u201322.","journal-title":"J Endourol"},{"issue":"4","key":"1354_CR62","doi-asserted-by":"publisher","first-page":"219","DOI":"10.5152\/tud.2025.24100","volume":"50","author":"V Patel","year":"2025","unstructured":"Patel V, Raghuvanshi K, Jadeja K, Chaudhari R. Comparison of Temperature Changes Between Holmium-YAG Laser and Thulium Fiber Laser in an In Vitro Setting. Urol Res Pract. 2025;50(4):219\u201324.","journal-title":"Urol Res Pract"},{"issue":"6","key":"1354_CR63","doi-asserted-by":"publisher","first-page":"1575","DOI":"10.1007\/s00345-022-03967-8","volume":"40","author":"MM Louters","year":"2022","unstructured":"Louters MM, Dau JJ, Hall TL, Ghani KR, Roberts WW. Laser operator duty cycle effect on temperature and thermal dose: in-vitro study. World J Urol. 2022;40(6):1575\u201380.","journal-title":"World J Urol"},{"issue":"1","key":"1354_CR64","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1186\/s12894-023-01396-2","volume":"24","author":"G Zhu","year":"2024","unstructured":"Zhu G, Li C, Guo Y, Sun L, Jin T, Wang Z, et al. Predicting stone composition via machine-learning models trained on intra-operative endoscopic digital images. BMC Urol. 2024;24(1):5.","journal-title":"BMC Urol"},{"issue":"1","key":"1354_CR65","doi-asserted-by":"publisher","first-page":"649","DOI":"10.1007\/s00345-025-06031-3","volume":"43","author":"A Morozov","year":"2025","unstructured":"Morozov A, Matkovskiy I, Somani B, Baniel J, Traxer O, Lifshitz D, et al. Intraoperative use of artificial intelligence (AI) during endoscopic lithotripsy: a systematic review from EAU endourology. World J Urol. 2025;43(1):649.","journal-title":"World J Urol"},{"issue":"1","key":"1354_CR66","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1002\/lsm.70081","volume":"58","author":"N Korneva","year":"2026","unstructured":"Korneva N, Budylin G, Tseregorodtseva P, Nikitin D, Andreeva V, Baytsaeva O, et al. Optical Feedback for Safe Automatic Laser Lithotripsy: Tissue Sensor Implementation in a Clinical System. Lasers Surg Med. 2026;58(1):38\u201348.","journal-title":"Lasers Surg Med"},{"key":"1354_CR67","doi-asserted-by":"publisher","unstructured":"Traxer O, Zorzi F, Yaroslavsky IV, Kovalenko A, Andreeva V, Childs J et al. Pre-clinical evaluation of a laser system with emission control based on stone vs soft tissue recognition. BJU Int. 2026. https:\/\/doi.org\/10.1111\/bju.70301.","DOI":"10.1111\/bju.70301"}],"container-title":["Current Urology Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11934-026-01354-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11934-026-01354-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11934-026-01354-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T03:12:09Z","timestamp":1786936329000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11934-026-01354-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,17]]},"references-count":67,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["1354"],"URL":"https:\/\/doi.org\/10.1007\/s11934-026-01354-z","relation":{},"ISSN":["1534-6285"],"issn-type":[{"value":"1534-6285","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,17]]},"assertion":[{"value":"20 July 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 August 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 August 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This article does not contain any studies with human or animal subjects performed by any of the authors.","order":1,"name":"Ethics","label":"Human and Animal Rights","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Khurshid R. Ghani has consulting relationships with Boston Scientific, Ambu, Olympus, Coloplast, Hugemed and Karl Storz. Brett A. Johnson reports consulting fees from NextMed LLC. Michael Uy is a co-investigator in a HugeMed-sponsored clinical trial. Gantapong Sainont, Pankaj N. Maheshwari, Hsiang Ying Lee, Daniele Castellani, Horacio Sanguinetti, and Yasser A. Noureldin declare no competing interests.","order":2,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"39"}}