{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T17:16:46Z","timestamp":1791825406137,"version":"4.3.4"},"reference-count":43,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clin Orthop Relat Res"],"published-print":{"date-parts":[[2018,2]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Crosslinked polyethylene (XLPE) liners used for primary THA have demonstrated lower wear rates than noncrosslinked, conventional polyethylene (CPE) liners through the first decade of clinical service. However, little high-quality evidence is currently available regarding the second decade performance of these implants and it remains uncertain whether the onset of osteolysis has simply been delayed or if the wear associated with XLPE liners will remain low enough that osteolysis will not occur. It is also unknown how the potential reductions in wear and osteolysis will influence long-term revision rates.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Questions\/purposes<\/jats:title>\n                    <jats:p>Do patients who underwent THA with XLPE liners demonstrate (1) a lower rate of revision for wear-related complications; (2) a reduced wear rate; and (3) a lower frequency of osteolysis compared with those with CPE liners?<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Over an 18-month period from 1999 to 2000, 226 patients who had 236 primary THAs consented to participate in a randomized controlled trial conducted at one institution. To be eligible for intraoperative randomization, patients had to be implanted with a 28-mm cobalt-chrome alloy femoral head, a 4-mm lateralized liner, and the same cup and stem design. Six patients with six THAs were excluded intraoperatively because they did not receive study components for reasons unrelated to the liner material. The remaining 230 THAs among 220 patients were randomized to XLPE liners or CPE liners. The mean age at surgery was 62 \u00b1 11 years and there were no differences in age, gender, or body mass index among the groups. There was no differential loss to followup between the study groups; among patients not known to be deceased or having undergone revision, minimum 14-year radiographic followup is available for 85 THAs including 46 with XLPE and 39 with CPE liners. Polyethylene wear was measured radiographically using Martell\u2019s Hip Analysis Suite and areas of osteolysis were evaluated before revision or at most recent followup. Revision rates at 15 years using reoperation for any reason and revision for wear or osteolysis were calculated using cumulative incidence considering patient death as a competing risk.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The cumulative incidence of revision at 15 years using reoperation for wear-related complications as an endpoint was lower in the XLPE group than the CPE group (0%, 95% confidence interval [CI], 0%-0% versus 12%, 95% CI, 7%-19%; p &lt; 0.001). Among unrevised THAs with minimum 14-year radiographic followup, the mean steady-state linear wear rate for THAs with XLPE liners was lower than the mean linear wear rate for the THAs with CPE liners (0.03 \u00b1 0.05 versus 0.17 \u00b1 0.09 mm\/year; mean difference, 0.14; 95% CI, 0.11-0.17; p &lt; 0.001). Osteolysis of any size was noted among 9% (four of 46) of the hips in the XLPE group and 46% (18 of 39) of the hips in the CPE group (odds ratio, 0.19; 95% CI, 0.07-0.51; p &lt; 0.001).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>This randomized study with followup into the second decade demonstrated reductions in revision, wear, and osteolysis associated with the use of XLPE. The low wear rates and absence of any mechanical failures among the XLPE liners at long-term followup affirm the durability of these components that did not incorporate antioxidants. Although osteolysis has not been eliminated, it occurs infrequently and has not caused any clinical problems to date.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of Evidence<\/jats:title>\n                    <jats:p>Level I, therapeutic study.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s11999.0000000000000036","type":"journal-article","created":{"date-parts":[[2018,2,21]],"date-time":"2018-02-21T08:47:55Z","timestamp":1519202875000},"page":"279-290","source":"Crossref","is-referenced-by-count":95,"title":["Otto Aufranc Award: Crosslinking Reduces THA Wear, Osteolysis, and Revision Rates at 15-year Followup Compared With Noncrosslinked Polyethylene"],"prefix":"10.1097","volume":"476","author":[{"given":"Robert H.","family":"Hopper","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Henry","family":"Ho","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Supatra","family":"Sritulanondha","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ann C.","family":"Williams","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Charles A.","family":"Engh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2018,1,17]]},"reference":[{"key":"R2-20230814","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1016\/j.arth.2012.12.005","article-title":"Total hip arthroplasty using highly cross-linked polyethylene in patients younger than 50 years with minimum 10-year follow-up","volume":"28","author":"Babovic","year":"2013","journal-title":"J Arthroplasty"},{"key":"R3-20230814","doi-asserted-by":"crossref","first-page":"1961","DOI":"10.1016\/j.arth.2014.05.008","article-title":"Fixation and wear with a contemporary acetabular component and cross-linked polyethylene at minimum 10-year follow-up","volume":"29","author":"Bedard","year":"2014","journal-title":"J Arthroplasty"},{"key":"R4-20230814","doi-asserted-by":"crossref","first-page":"1487","DOI":"10.2106\/JBJS.F.00991","article-title":"Reduction of osteolysis with use of Marathon cross-linked polyethylene. A concise follow-up, at a minimum of five years, of a previous report","volume":"90","author":"Bitsch","year":"2008","journal-title":"J Bone Joint Surg Am."},{"key":"R5-20230814","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1097\/01.blo.0000150124.34906.34","article-title":"Fatigue crack propagation resistance of highly crosslinked polyethylene","volume":"429","author":"Bradford","year":"2004","journal-title":"Clin Orthop Relat Res."},{"key":"R6-20230814","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1007\/s11999-012-2604-0","article-title":"The 2012 John Charnley Award. Clinical multicenter studies of the wear performance of highly crosslinked remelted polyethylene in THA","volume":"471","author":"Bragdon","year":"2013","journal-title":"Clin Orthop Relat Res."},{"key":"R7-20230814","doi-asserted-by":"crossref","first-page":"1186","DOI":"10.1016\/j.arth.2016.10.037","article-title":"The relationship between polyethylene wear and peri-prosthetic osteolysis in total hip arthroplasty at 12 years in a randomized controlled trial cohort","volume":"32","author":"Broomfield","year":"2017","journal-title":"J Arthroplasty"},{"key":"R8-20230814","doi-asserted-by":"crossref","first-page":"e98","DOI":"10.2106\/JBJS.16.00868","article-title":"The appropriate variable to compare wear in total hip prostheses: commentary on an article by Howie DW, et al. The wear rate of highly cross-linked polyethylene in total hip replacement is not increased by large articulations. A randomized controlled trial","volume":"98","author":"Burstein","year":"2016","journal-title":"J Bone Joint Surg Am."},{"key":"R9-20230814","doi-asserted-by":"crossref","first-page":"1519","DOI":"10.2106\/00004623-200308000-00013","article-title":"Radiographic definition of pelvic osteolysis following total hip arthroplasty","volume":"85","author":"Claus","year":"2003","journal-title":"J Bone Joint Surg Am."},{"key":"R10-20230814","doi-asserted-by":"crossref","first-page":"2409","DOI":"10.2106\/JBJS.I.01006","article-title":"In vivo oxidation in remelted highly cross-linked retrievals","volume":"92","author":"Currier","year":"2010","journal-title":"J Bone Joint Surg Am."},{"key":"R11-20230814","doi-asserted-by":"crossref","first-page":"746","DOI":"10.1080\/17453670710014518","article-title":"5-year experience of highly cross-linked polyethylene in cemented and uncemented sockets: two randomized studies using radiostereometric analysis","volume":"78","author":"Digas","year":"2007","journal-title":"Acta Orthop"},{"key":"R12-20230814","first-page":"1816","article-title":"Clinical performance of a Durasul highly cross-linked polyethylene acetabular liner for total hip arthroplasty at five years","volume":"87","author":"Dorr","year":"2005","journal-title":"J Bone Joint Surg Am."},{"issue":"158","key":"R13-20230814","first-page":"e15","article-title":"Fracture of a cross-linked polyethylene liner due to impingement","volume":"24","author":"Duffy","year":"2009","journal-title":"J Arthroplasty"},{"key":"R14-20230814","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1054\/arth.2002.33664","article-title":"A literature review of the association between wear rate and osteolysis in total hip arthroplasty","volume":"17","author":"Dumbleton","year":"2002","journal-title":"J Arthroplasty"},{"key":"R15-20230814","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1243\/0954411021536333","article-title":"Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses","volume":"216","author":"Endo","year":"2002","journal-title":"Proc Inst Mech Eng H"},{"issue":"Suppl 1","key":"R16-20230814","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/j.arth.2012.03.048","article-title":"A prospective, randomized study of cross-linked and noncross-linked polyethylene for total hip arthroplasty at 10-year follow-up","volume":"27","author":"Engh","year":"2012","journal-title":"J Arthroplasty"},{"issue":"Suppl 2","key":"R17-20230814","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/j.arth.2006.05.002","article-title":"A randomized prospective evaluation of outcomes after total hip arthroplasty using cross-linked Marathon and non-cross-linked Enduron polyethylene liners","volume":"21","author":"Engh","year":"2006","journal-title":"J Arthroplasty"},{"key":"R18-20230814","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1007\/s10856-006-7309-z","article-title":"Wear of crosslinked polyethylene under different tribological conditions","volume":"17","author":"Galvin","year":"2006","journal-title":"J Mater Sci Mater Med"},{"key":"R19-20230814","doi-asserted-by":"crossref","first-page":"977","DOI":"10.1016\/j.wear.2005.02.035","article-title":"Nanometre size wear debris generated from crosslinked and non-crosslinked ultra high molecular weight polyethylene in artificial joints","volume":"259","author":"Galvin","year":"2005","journal-title":"Wear"},{"key":"R20-20230814","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1243\/09544119JEIM99","article-title":"Wear and biological activity of highly crosslinked polyethylene in the hip under low serum protein concentrations","volume":"221","author":"Galvin","year":"2007","journal-title":"Proc Inst Mech Eng H"},{"key":"R21-20230814","doi-asserted-by":"crossref","first-page":"326","DOI":"10.1302\/0301-620X.95B3.29456","article-title":"New polyethylenes in total hip replacement. A ten- to 12-year followup study","volume":"95","author":"Garcia-Rey","year":"2013","journal-title":"Bone Joint J"},{"key":"R22-20230814","doi-asserted-by":"crossref","first-page":"719","DOI":"10.1080\/17453670610012890","article-title":"Crosslinked polyethylene compared to conventional polyethylene in total hip replacement: pre-clinical evaluation, in-vitro testing and prospective clinical follow-up study","volume":"77","author":"Geerdink","year":"2006","journal-title":"Acta Orthop"},{"key":"R23-20230814","doi-asserted-by":"crossref","first-page":"1550","DOI":"10.1016\/j.biomaterials.2005.09.010","article-title":"Fatigue crack propagation resistance of virgin and highly crosslinked, thermally treated ultra-high molecular weight polyethylene","volume":"27","author":"Gencur","year":"2006","journal-title":"Biomaterials"},{"key":"R24-20230814","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1007\/s11999-014-3735-2","article-title":"The John Charnley Award: Highly crosslinked polyethylene in total hip arthroplasty decreases long-term wear: a double-blind randomized trial","volume":"473","author":"Glyn-Jones","year":"2015","journal-title":"Clin Orthop Relat Res."},{"key":"R25-20230814","doi-asserted-by":"crossref","first-page":"748","DOI":"10.2106\/00004623-200404000-00012","article-title":"Short-term in vivo wear of cross-linked polyethylene","volume":"86","author":"Heisel","year":"2004","journal-title":"J Bone Joint Surg Am."},{"key":"R26-20230814","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1016\/j.arth.2008.01.134","article-title":"Highly crosslinked vs conventional polyethylene particles: relative in vivo inflammatory response","volume":"24","author":"Illgen","year":"2009","journal-title":"J Arthroplasty"},{"key":"R27-20230814","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1016\/j.arth.2007.05.043","article-title":"Highly crosslinked vs conventional polyethylene particles\u2013an in vitro comparison of biologic activities","volume":"23","author":"Illgen","year":"2008","journal-title":"J Arthroplasty"},{"key":"R28-20230814","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1054\/arth.2001.19160","article-title":"Socket wear in bilateral simultaneous total hip arthroplasty","volume":"16","author":"Joshi","year":"2001","journal-title":"J Arthroplasty"},{"key":"R29-20230814","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1097\/01.blo.0000246554.41058.8d","article-title":"The value of anteroposterior pelvic radiographs for evaluating pelvic osteolysis","volume":"453","author":"Kitamura","year":"2006","journal-title":"Clin Orthop Relat Res."},{"key":"R30-20230814","doi-asserted-by":"crossref","first-page":"2262","DOI":"10.1007\/s11999-011-1872-4","article-title":"History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene","volume":"469","author":"Kurtz","year":"2011","journal-title":"Clin Orthop Relat Res."},{"key":"R31-20230814","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1007\/s11999-015-4319-5","article-title":"Wear and osteolysis of highly crosslinked polyethylene at 10 to 14 years: the effect of femoral head size","volume":"474","author":"Lachiewicz","year":"2016","journal-title":"Clin Orthop Relat Res."},{"key":"R32-20230814","doi-asserted-by":"crossref","first-page":"2278","DOI":"10.1007\/s11999-010-1728-3","article-title":"Do first-generation highly crosslinked polyethylenes oxidize in vivo?","volume":"469","author":"MacDonald","year":"2011","journal-title":"Clin Orthop Relat Res."},{"key":"R33-20230814","doi-asserted-by":"crossref","first-page":"1635","DOI":"10.2106\/00004623-199711000-00004","article-title":"Determination of polyethylene wear in total hip replacements with the use of digital radiographs","volume":"79","author":"Martell","year":"1997","journal-title":"J Bone Joint Surg Am."},{"key":"R34-20230814","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1002\/jor.1100170203","article-title":"Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements","volume":"17","author":"McKellop","year":"1999","journal-title":"J Orthop Res."},{"key":"R35-20230814","doi-asserted-by":"crossref","first-page":"380","DOI":"10.1002\/jbm.b.30807","article-title":"Comparative fatigue behavior and toughness of remelted and annealed highly crosslinked polyethylenes","volume":"83","author":"Medel","year":"2007","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"R36-20230814","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1002\/jbm.b.31048","article-title":"Wear particle analysis of highly crosslinked polyethylene isolated from a failed total hip arthroplasty","volume":"86","author":"Minoda","year":"2008","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"R37-20230814","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/j.jmbbm.2015.06.028","article-title":"In-vivo degradation of middle-term highly cross-linked and remelted polyethylene cups: modification induced by creep, wear and oxidation","volume":"51","author":"Miura","year":"2015","journal-title":"J Mech Behav Biomed Mater."},{"key":"R38-20230814","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1054\/arth.2003.50023","article-title":"Can component and patient factors account for the variance in wear rates among bilateral total hip arthroplasty patients?","volume":"18","author":"Orishimo","year":"2003","journal-title":"J Arthroplasty"},{"key":"R39-20230814","doi-asserted-by":"crossref","first-page":"1011","DOI":"10.1007\/s11999-014-4105-9","article-title":"Metal-on-conventional polyethylene total hip arthroplasty bearing surfaces have a higher risk of revision than metal-on-highly crosslinked polyethylene: results from a US registry","volume":"473","author":"Paxton","year":"2015","journal-title":"Clin Orthop Relat Res."},{"key":"R40-20230814","doi-asserted-by":"crossref","first-page":"148","DOI":"10.3109\/17453674.2011.652889","article-title":"No adverse effects of submelt-annealed highly crosslinked polyethylene in cemented cups: an RSA study of 8 patients 10 years after surgery","volume":"83","author":"R\u00f6hrl","year":"2012","journal-title":"Acta Orthop"},{"key":"R41-20230814","doi-asserted-by":"crossref","first-page":"743","DOI":"10.1016\/j.arth.2008.02.012","article-title":"Pelvic osteolysis relationship to radiographs and polyethylene wear","volume":"24","author":"Shon","year":"2009","journal-title":"J Arthroplasty"},{"key":"R42-20230814","doi-asserted-by":"crossref","first-page":"821","DOI":"10.2106\/00004623-199906000-00009","article-title":"Analysis of temporal wear patterns of porous-coated acetabular components: distinguishing between true wear and so-called bedding-in","volume":"81","author":"Sychterz","year":"1999","journal-title":"J Bone Joint Surg Am."},{"key":"R43-20230814","doi-asserted-by":"crossref","first-page":"5","DOI":"10.3109\/17453679809002345","article-title":"Short periods of oscillating fluid pressure directed at a titanium-bone interface in rabbits lead to bone lysis","volume":"69","author":"van der Vis","year":"1998","journal-title":"Acta Orthop Scand"},{"key":"R44-20230814","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1016\/j.arth.2003.10.005","article-title":"The pumping of fluid in cementless cups with holes","volume":"19","author":"Walter","year":"2004","journal-title":"J Arthroplasty"}],"container-title":["Clinical Orthopaedics &amp; Related Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00003086-201802000-00018","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,14]],"date-time":"2023-08-14T01:55:47Z","timestamp":1691978147000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00003086-201802000-00018"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,1,17]]},"references-count":43,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1007\/s11999.0000000000000036","relation":{},"ISSN":["0009-921X"],"issn-type":[{"value":"0009-921X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,1,17]]}}}