{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,10]],"date-time":"2026-07-10T23:21:33Z","timestamp":1783725693371,"version":"3.55.0"},"reference-count":51,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clin Orthop Relat Res"],"published-print":{"date-parts":[[2018,2]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>In 2010, a widely used metal-on-metal hip implant design was voluntarily recalled by the manufacturer because of higher than anticipated failure rates at 5 years. Although there was a large published range of revision rates, numerous studies had reported a higher risk of revision for excessive wear and associated adverse tissue reactions when compared with other metal-on-metal total hips. The reasons for this were suggested by some to be related to cup design features.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Questions\/purposes<\/jats:title>\n            <jats:p>From retrievals of ASR metal-on-metal implants and tissue samples obtained at revision surgery, we asked the following questions: (1) What were the common and uncommon surface features? (2) What were the common and uncommon linear and volumetric wear characteristics? (3) Were there common taper corrosion characteristics? (4) What aseptic lymphocytic vasculitis-associated lesion (ALVAL) features were present in the tissues?<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Five hundred fifty-five ASRs, including 23 resurfacings, were studied at one academic research center. Features of wear (eg, light and moderate scratching), damage (eg, deposits, gouges), and bone attachment on the porous coating were semiquantitatively ranked from 0 (none) to 3 (&gt; 75%) based on the amount of a feature in each region of interest by the same experienced observer throughout the study. Visible features of head taper corrosion were ranked (Goldberg score) from 1 (none) to 4 (severe) by the same observer using a previously published scoring method. An experienced tribologist measured component wear depth using a coordinate measuring machine and quantified wear volume using previously validated methods. All available tissues were sampled and examined for features of ALVAL and scored from 0 to 10 by a single observer using a method they previously developed and published. A score from 0 to 4 is considered low, 5 to 8 is considered moderate, and 9 or 10 is considered high with regard to the risk of metal hypersensitivity features in the tissues.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>The most common bearing surface features were light and moderate scratches and removal or postremoval damage. Discoloration and deposits were commonly observed on femoral heads (55% [305 of 553]) and less commonly on cups (30% [165 of 546]). There was no evidence of impingement or dislocation damage. There was typically a small amount of bone attachment in at least one of eight designated regions of interest (84% [460 of 546]); extensive or no bone attachment was uncommon. Edge wear was highly prevalent. The maximum wear of 469 cups (88%) occurred near the edge, whereas the maximum wear of 508 femoral heads (94%) occurred between the pole and 45\u00b0 from the pole. The median combined head-cup wear volume was 14 mm<jats:sup>3<\/jats:sup> (range, 1-636 mm<jats:sup>3<\/jats:sup>). One hundred sixty-nine pairs (32%) had a combined wear volume of &lt; 10 mm<jats:sup>3<\/jats:sup>, 42 pairs (8%) had volumetric wear of &gt; 100 mm<jats:sup>3<\/jats:sup>, and 319 pairs (60%) had wear volume between 10 and 100 mm\u00b3. Seventy-four percent of tapers (390 of 530) received a Goldberg score of 4, 22% (116 of 530) a score of 3, &lt; 5% (24 of 530) a score of 2, and none received a score of 1. The most frequent ALVAL score was 5 out of 10 (35 of 144 hips [24%]) and ranged from 2 (one hip) to 10 (nine hips); 92 of 144 (64%) had a moderate score, 17 of 144 (12%) had a high score, and 35 (24%) had a low score.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Although edge wear was prevalent, in most cases, this was not associated with high wear. The increased diameter and decreased coverage angle of the ASR design may have resulted in the observed high incidence of edge wear while perhaps decreasing the risk for impingement and dislocation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Clinical Relevance<\/jats:title>\n            <jats:p>The role of bearing wear in the revisions of metal-on-metal implants is controversial, because it is known that there is a large range of in vivo wear rates even within the same implant type and that patient variability affects local tissue responses to wear debris. The observations from our study of 555 retrieved ASR implant sets indicate that there was a wide range of wear including a subset with very high wear. The results suggested that the failure of the ASR and ASR XL was multifactorial, and the failure of different subgroups such as those with low wear may be the result of mechanisms other than reaction to wear debris.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1007\/s11999.0000000000000044","type":"journal-article","created":{"date-parts":[[2018,2,21]],"date-time":"2018-02-21T13:47:55Z","timestamp":1519220875000},"page":"261-278","source":"Crossref","is-referenced-by-count":35,"title":["Five Hundred Fifty-five Retrieved Metal-on-metal Hip Replacements of a Single Design Show a Wide Range of Wear, Surface Features, and Histopathologic Reactions"],"prefix":"10.1097","volume":"476","author":[{"given":"Sang-Hyun","family":"Park","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhen","family":"Lu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert S.","family":"Hastings","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patricia A.","family":"Campbell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edward","family":"Ebramzadeh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2018,1,17]]},"reference":[{"key":"R1-20230814","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1097\/01.blo.0000150310.25603.26","article-title":"Prevention and treatment of dislocation after total hip replacement using large diameter balls","volume":"429","author":"Amstutz","year":"2004","journal-title":"Clin Orthop Relat Res."},{"key":"R2-20230814","doi-asserted-by":"crossref","first-page":"e20","DOI":"10.2106\/JBJS.N.00973","article-title":"A new approach to managing patients with problematic metal hip implants: the use of an Internet-enhanced multidisciplinary team meeting: AAOS exhibit selection","volume":"97","author":"Berber","year":"2015","journal-title":"J Bone Joint Surg Am."},{"key":"R3-20230814","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1016\/j.arth.2011.08.022","article-title":"Disappointing short-term results with the DePuy ASR XL metal-on-metal total hip arthroplasty","volume":"27","author":"Bernthal","year":"2012","journal-title":"J Arthroplasty."},{"key":"R4-20230814","doi-asserted-by":"crossref","first-page":"1116","DOI":"10.1002\/jor.22326","article-title":"Wear patterns of taper connections in retrieved large diameter metal-on-metal bearings","volume":"31","author":"Bishop","year":"2013","journal-title":"J Orthop Res."},{"key":"R5-20230814","doi-asserted-by":"crossref","first-page":"1614","DOI":"10.2106\/JBJS.H.01220","article-title":"The epidemiology of bearing surface usage in total hip arthroplasty in the United States","volume":"91","author":"Bozic","year":"2009","journal-title":"J Bone Joint Surg Am."},{"key":"R6-20230814","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1097\/01.blo.0000238777.34939.82","article-title":"The John Charnley Award: A study of implant failure in metal-on-metal surface arthroplasties","volume":"453","author":"Campbell","year":"2006","journal-title":"Clin Orthop Relat Res."},{"key":"R7-20230814","doi-asserted-by":"crossref","first-page":"2321","DOI":"10.1007\/s11999-010-1372-y","article-title":"Histological features of pseudotumor-like tissues from metal-on-metal hips","volume":"468","author":"Campbell","year":"2010","journal-title":"Clin Orthop Relat Res."},{"key":"R8-20230814","doi-asserted-by":"crossref","first-page":"1080","DOI":"10.1016\/j.arth.2007.09.024","article-title":"Metal sensitivity as a cause of groin pain in metal-on-metal hip resurfacing","volume":"23","author":"Campbell","year":"2008","journal-title":"J Arthroplasty."},{"key":"R9-20230814","doi-asserted-by":"crossref","first-page":"3718","DOI":"10.1007\/s11999-014-3893-2","article-title":"Do retrieval analysis and blood metal measurements contribute to our understanding of adverse local tissue reactions?","volume":"472","author":"Campbell","year":"2014","journal-title":"Clin Orthop Relat Res."},{"key":"R10-20230814","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1302\/0301-620X.90B10.20533","article-title":"Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement","volume":"90","author":"De Haan","year":"2008","journal-title":"J Bone Joint Surg Br."},{"key":"R11-20230814","doi-asserted-by":"crossref","first-page":"2287","DOI":"10.2106\/JBJS.J.01727","article-title":"Five-year results of the ASR XL Acetabular System and the ASR Hip Resurfacing System: an analysis from the Australian Orthopaedic Association National Joint Replacement Registry","volume":"93","author":"de Steiger","year":"2011","journal-title":"J Bone Joint Surg Am."},{"key":"R12-20230814","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1243\/095441105X69114","article-title":"Metal-on-metal hip joint tribology","volume":"220","author":"Dowson","year":"2006","journal-title":"Proc Inst Mech Eng H."},{"key":"R13-20230814","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1007\/s11999-014-3874-5","article-title":"Can wear explain the histological variation around metal-on-metal total hips?","volume":"473","author":"Ebramzadeh","year":"2015","journal-title":"Clin Orthop Relat Res."},{"key":"R14-20230814","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1016\/j.ocl.2011.01.001","article-title":"Failure modes of 433 metal-on-metal hip implants: how, why, and wear","volume":"42","author":"Ebramzadeh","year":"2011","journal-title":"Orthop Clin North Am."},{"key":"R15-20230814","doi-asserted-by":"crossref","first-page":"2180","DOI":"10.2106\/JBJS.J.01206","article-title":"The in vivo linear and volumetric wear of hip resurfacing implants revised for pseudotumor","volume":"93","author":"Glyn-Jones","year":"2011","journal-title":"J Bone Joint Surg Am."},{"key":"R16-20230814","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1097\/00003086-200208000-00018","article-title":"A multicenter retrieval study of the taper interfaces of modular hip prostheses","volume":"401","author":"Goldberg","year":"2002","journal-title":"Clin Orthop Relat Res."},{"key":"R17-20230814","doi-asserted-by":"crossref","first-page":"e81","DOI":"10.2106\/JBJS.L.00775","article-title":"The correlation of wear with histological features after failed hip resurfacing arthroplasty","volume":"95","author":"Grammatopoulos","year":"2013","journal-title":"J Bone Joint Surg Am."},{"key":"R18-20230814","doi-asserted-by":"crossref","first-page":"2328","DOI":"10.1007\/s11999-010-1383-8","article-title":"Reduced articular surface of one-piece cups: a cause of runaway wear and early failure","volume":"468","author":"Griffin","year":"2010","journal-title":"Clin Orthop Relat Res."},{"key":"R19-20230814","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1243\/095441105X69132","article-title":"Development rationale for an articular surface replacement: a science-based evolution","volume":"220","author":"Isaac","year":"2006","journal-title":"Proc Inst Mech Eng H."},{"key":"R21-20230814","doi-asserted-by":"crossref","first-page":"356","DOI":"10.1302\/0301-620X.92B3.23281","article-title":"Analysis of wear of retrieved metal-on-metal hip resurfacing implants revised due to pseudotumours","volume":"92","author":"Kwon","year":"2010","journal-title":"J Bone Joint Surg Br."},{"key":"R22-20230814","doi-asserted-by":"crossref","first-page":"444","DOI":"10.1002\/jor.21015","article-title":"Lymphocyte proliferation responses in patients with pseudotumors following metal-on-metal hip resurfacing arthroplasty","volume":"28","author":"Kwon","year":"2010","journal-title":"J Orthop Res."},{"key":"R23-20230814","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1016\/j.arth.2016.06.060","article-title":"Outcomes of the recalled Articular Surface Replacement metal-on-metal hip implant system: a systematic review","volume":"32","author":"Laaksonen","year":"2017","journal-title":"J Arthroplasty."},{"key":"R24-20230814","doi-asserted-by":"crossref","first-page":"1011","DOI":"10.1302\/0301-620X.93B8.26040","article-title":"Accelerating failure rate of the ASR total hip replacement","volume":"93","author":"Langton","year":"2011","journal-title":"J Bone Joint Surg Br."},{"key":"R25-20230814","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1302\/0301-620X.92B1.22770","article-title":"Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: a consequence of excess wear","volume":"92","author":"Langton","year":"2010","journal-title":"J Bone Joint Surg Br."},{"key":"R26-20230814","doi-asserted-by":"crossref","first-page":"1143","DOI":"10.1302\/0301-620X.90B9.20785","article-title":"The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip","volume":"90","author":"Langton","year":"2008","journal-title":"J Bone Joint Surg Br."},{"key":"R27-20230814","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1302\/0301-620X.93B2.25099","article-title":"Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear","volume":"93","author":"Langton","year":"2011","journal-title":"J Bone Joint Surg Br."},{"key":"R28-20230814","doi-asserted-by":"crossref","first-page":"1287","DOI":"10.1302\/0301-620X.91B10.22308","article-title":"Blood metal ion concentrations after hip resurfacing arthroplasty: a comparative study of articular surface replacement and Birmingham Hip Resurfacing arthroplasties","volume":"91","author":"Langton","year":"2009","journal-title":"J Bone Joint Surg Br."},{"key":"R29-20230814","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/j.wear.2011.07.009","article-title":"Volumetric wear assessment of failed metal-on-metal hip resurfacing prostheses","volume":"272","author":"Lord","year":"2011","journal-title":"Wear."},{"key":"R30-20230814","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1177\/0954411914524188","article-title":"Accuracy of methods for calculating volumetric wear from coordinate measuring machine data of retrieved metal-on-metal hip joint implants","volume":"228","author":"Lu","year":"2014","journal-title":"Proc Inst Mech Eng H."},{"key":"R31-20230814","first-page":"1832","article-title":"Impingement with total hip replacement","volume":"89","author":"Malik","year":"2007","journal-title":"J Bone Joint Surg Am."},{"key":"R32-20230814","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1302\/0301-620X.93B3.25551","article-title":"Retrieval analysis of 240 metal-on-metal hip components, comparing modular total hip replacement with hip resurfacing","volume":"93","author":"Matthies","year":"2011","journal-title":"J Bone Joint Surg Br."},{"key":"R33-20230814","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1002\/jor.22459","article-title":"Predicting wear and blood metal ion levels in metal-on-metal hip resurfacing","volume":"32","author":"Matthies","year":"2014","journal-title":"J Orthop Res."},{"key":"R34-20230814","doi-asserted-by":"crossref","first-page":"1677","DOI":"10.1002\/jor.22431","article-title":"Material loss at the taper junction of retrieved large head metal-on-metal total hip replacements","volume":"31","author":"Matthies","year":"2013","journal-title":"J Orthop Res."},{"issue":"Suppl","key":"R35-20230814","doi-asserted-by":"crossref","first-page":"S128","DOI":"10.1097\/00003086-199608001-00013","article-title":"In vivo wear of three types of metal on metal hip prostheses during two decades of use","volume":"329","author":"McKellop","year":"1996","journal-title":"Clin Orthop Relat Res."},{"key":"R36-20230814","doi-asserted-by":"crossref","first-page":"1221","DOI":"10.1002\/jor.22651","article-title":"A lexicon for wear of metal-on-metal hip prostheses","volume":"32","author":"McKellop","year":"2014","journal-title":"J Orthop Res."},{"key":"R37-20230814","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1243\/095441105X69015","article-title":"Biomechanical, morphological, and histological analysis of early failures in hip resurfacing arthroplasty","volume":"220","author":"Morlock","year":"2006","journal-title":"Proc Inst Mech Eng H."},{"issue":"Suppl 3","key":"R38-20230814","doi-asserted-by":"crossref","first-page":"89","DOI":"10.2106\/JBJS.H.00621","article-title":"Modes of implant failure after hip resurfacing: morphological and wear analysis of 267 retrieval specimens","volume":"90","author":"Morlock","year":"2008","journal-title":"J Bone Joint Surg Am."},{"key":"R39-20230814","doi-asserted-by":"crossref","first-page":"553","DOI":"10.1186\/1756-0500-5-553","article-title":"Risk of dislocation using large- vs small-diameter femoral heads in total hip arthroplasty","volume":"5","author":"Plate","year":"2012","journal-title":"BMC Res Notes."},{"key":"R40-20230814","doi-asserted-by":"crossref","first-page":"1081","DOI":"10.1016\/S0142-9612(02)00410-6","article-title":"Retrieval study of uncemented metal-metal hip prostheses revised for early loosening","volume":"24","author":"Reinisch","year":"2003","journal-title":"Biomaterials."},{"key":"R41-20230814","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1177\/112070000201200202","article-title":"In vivo tribological performance of 231 metal-on-metal hip articulations","volume":"12","author":"Rieker","year":"2002","journal-title":"Hip Int."},{"key":"R42-20230814","doi-asserted-by":"crossref","first-page":"277","DOI":"10.3109\/17453670902988378","article-title":"Mathematical evaluation of jumping distance in total hip arthroplasty: influence of abduction angle, femoral head offset, and head diameter","volume":"80","author":"Sariali","year":"2009","journal-title":"Acta Orthop."},{"key":"R43-20230814","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1302\/2046-3758.25.2000148","article-title":"Blood metal ion testing is an effective screening tool to identify poorly performing metal-on-metal bearing surfaces","volume":"2","author":"Sidaginamale","year":"2013","journal-title":"Bone Joint Res."},{"key":"R44-20230814","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1302\/0301-620X.81B1.0810046","article-title":"Analysis of 118 second-generation metal-on-metal retrieved hip implants","volume":"81","author":"Sieber","year":"1999","journal-title":"J Bone Joint Surg Br."},{"key":"R45-20230814","doi-asserted-by":"crossref","first-page":"1759","DOI":"10.1016\/S0140-6736(12)60989-1","article-title":"Failure rates of metal-on-metal hip resurfacings: analysis of data from the National Joint Registry for England and Wales","volume":"380","author":"Smith","year":"2012","journal-title":"Lancet."},{"key":"R46-20230814","doi-asserted-by":"crossref","first-page":"410","DOI":"10.1016\/j.arth.2013.05.032","article-title":"Wear analysis of 39 Conserve Plus metal-on-metal hip resurfacing retrievals","volume":"29","author":"Takamura","year":"2014","journal-title":"J Arthroplasty."},{"key":"R47-20230814","doi-asserted-by":"crossref","first-page":"2017","DOI":"10.1007\/s00264-014-2369-z","article-title":"The effect of a manufacturer recall on the threshold to revise a metal-on-metal hip","volume":"38","author":"Tibrewal","year":"2014","journal-title":"Int Orthop."},{"key":"R48-20230814","doi-asserted-by":"crossref","first-page":"1169","DOI":"10.1302\/0301-620X.93B9.26511","article-title":"A comparison of explanted Articular Surface Replacement and Birmingham Hip Resurfacing components","volume":"93","author":"Underwood","year":"2011","journal-title":"J Bone Joint Surg Br."},{"key":"R49-20230814","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1177\/0954411911431397","article-title":"Edge loading in metal-on-metal hips: low clearance is a new risk factor","volume":"226","author":"Underwood","year":"2012","journal-title":"Proc Inst Mech Eng H."},{"key":"R50-20230814","doi-asserted-by":"crossref","first-page":"362","DOI":"10.5301\/HIP.2012.9351","article-title":"The articular surface replacement implant recall: a United Kingdom district hospital experience","volume":"22","author":"Whitwell","year":"2012","journal-title":"Hip Int."},{"issue":"Suppl 3","key":"R51-20230814","doi-asserted-by":"crossref","first-page":"111","DOI":"10.2106\/JBJS.H.00485","article-title":"Tribology and wear of metal-on-metal hip prostheses: influence of cup angle and head position","volume":"90","author":"Williams","year":"2008","journal-title":"J Bone Joint Surg Am."},{"key":"R52-20230814","doi-asserted-by":"crossref","first-page":"951","DOI":"10.1016\/j.arth.2008.06.022","article-title":"In vivo wear rate of the Birmingham Hip Resurfacing arthroplasty. A review of 10 retrieved components","volume":"24","author":"Witzleb","year":"2009","journal-title":"J Arthroplasty."}],"container-title":["Clinical Orthopaedics &amp; Related Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00003086-201802000-00017","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,14]],"date-time":"2023-08-14T05:55:43Z","timestamp":1691992543000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00003086-201802000-00017"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,1,17]]},"references-count":51,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1007\/s11999.0000000000000044","relation":{},"ISSN":["0009-921X"],"issn-type":[{"value":"0009-921X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,1,17]]}}}