{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T21:05:21Z","timestamp":1760130321369},"reference-count":29,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clin Orthop Relat Res"],"published-print":{"date-parts":[[2019,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Methods to reduce the revision rate of total knee prostheses because of wear-related issues are important to examine, particularly because younger patients have a disproportionately high risk of revision.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Questions\/purposes<\/jats:title>\n            <jats:p>(1) Are long-term Knee Society knee and function scores better in younger patients with an oxidized zirconium (OxZr) TKA compared with those with a cobalt-chrome (CoCr) TKA? (2) Are there differences in radiographic signs of loosening or CT findings of osteolysis between OxZr TKAs and CoCr TKAs? (3) Are there fewer polyethylene wear particles in the OxZr TKA than CoCr TKA? (4) Do the groups differ in terms of survivorship free from revision surgery at 13 years?<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>From April 2003 to January 2007, we enrolled 110 patients younger than 55 years of age in this randomized, double-blind, prospective trial. Each patient served as his or her own control and each received an OxZr femoral component in one knee and a CoCr femoral component in the other. The minimum followup was 10 years (mean, 13 years; range, 10-14 years); two died and nine were lost to followup before that time, leaving 99 patients (198 knees) for analysis. There were 28 men and 71 women with a mean age of 53 \u00b1 6 years (range, 40-55 years). We obtained Knee Society knee scores for each knee, but Knee Society function scores, WOMAC scores, and UCLA activity scores were obtained for each patient preoperatively and at each followup. Additionally, we performed radiographic examination preoperatively and at each followup. At a minimum of 10 years (mean, 13 years) followup, we obtained CT scans in all patients. Polyethylene wear particles in the synovial fluid were analyzed at the final followup using thermogravimetric methods and scanning electron microscopy. Survivorship was ascertained using the Kaplan-Meier calculator. A sample size calculation determined that to detect a difference in the Knee Society knee score of 5 points, assuming a SD of 5 points, with an \u03b1 = 0.05 and \u03b2 = 0.80, a total of 90 patients would be needed in each group.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>At the most recent followup, the mean Knee Society knee scores (92 versus 93 points; p = 0.857), function scores (85 versus 85 points; p = 1.000), WOMAC scores (23 versus 23 points; p = 1.000), UCLA activity scores (6.5 versus 6.5 points; p = 1.000), and range of knee motion (125\u00b0 versus 127\u00b0; p = 0.365) were not different between the two groups. There was no radiographic evidence of loosening and no osteolysis visible on CT scan in either group. The weight of polyethylene wear particles produced at the bearing surface was 0.046 \u00b1 0.010 g in 1 g of synovial fluid in patients with an OxZr femoral component and 0.0448 \u00b1 0.0108 g in patients with a CoCr femoral component (p = 0.583). Kaplan-Meier survivorship free from revision was 97% for the OxZr group (95% confidence interval [CI], 93\u2013100) and 98% for the CoCr group (95% CI, 93\u2013100) at 13 years after surgery (p = 0.918).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Given the absence of demonstrated superiority of either the CoCr implant or the OxZr implant, we recommend that surgeons and healthcare systems can reasonably choose the less expensive device for routine use, unless there is some compelling reason in an individual patient to choose one over the other (such as severe, documented metal sensitivity).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Level of Evidence<\/jats:title>\n            <jats:p>Level I, therapeutic study.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1007\/s11999.0000000000000271","type":"journal-article","created":{"date-parts":[[2018,6,28]],"date-time":"2018-06-28T15:21:55Z","timestamp":1530199315000},"page":"49-57","source":"Crossref","is-referenced-by-count":10,"title":["The 2018 Mark Coventry, MD Award: Does a Ceramic Bearing Improve Pain, Function, Wear, or Survivorship of TKA in Patients Younger Than 55 Years of Age? A Randomized Trial"],"prefix":"10.1097","volume":"477","author":[{"given":"Young-Hoo","family":"Kim","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jang-Won","family":"Park","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jun-Shik","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2018,3,28]]},"reference":[{"key":"R1-20230814","first-page":"7","article-title":"Osteoarthrosis of the knee: a radiographic investigation","volume":"277","author":"Ahlb\u00e4ck","year":"1968","journal-title":"Acta Radiol Diagn (Stockh)."},{"key":"R2-20230814","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1302\/0301-620X.98B1.36314","article-title":"Total knee arthroplasty with an oxidised zirconium femoral component: ten-year survivorship analysis","volume":"98","author":"Ahmed","year":"2016","journal-title":"Bone Joint J."},{"key":"R4-20230814","first-page":"1833","article-title":"Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee","volume":"15","author":"Bellamy","year":"1988","journal-title":"J Rheumatol"},{"key":"R5-20230814","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1097\/01.blo.0000148576.70780.13","article-title":"Oxidized zirconium femoral component reduce polyethylene wear in a knee wear simulator","volume":"428","author":"Ezzet","year":"2004","journal-title":"Clin Orthop Relat Res."},{"issue":"Suppl 4","key":"R6-20230814","doi-asserted-by":"crossref","first-page":"105","DOI":"10.2106\/00004623-200300004-00013","article-title":"Reduced wear with oxidized zirconium femoral heads","volume":"85","author":"Good","year":"2003","journal-title":"J Bone Joint Surg Am."},{"key":"R8-20230814","doi-asserted-by":"crossref","first-page":"787","DOI":"10.1016\/j.arth.2007.05.041","article-title":"Osteolysis after total knee arthroplasty","volume":"22","author":"Gupta","year":"2007","journal-title":"J Arthroplasty"},{"key":"R9-20230814","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1016\/j.knee.2010.08.011","article-title":"Matched-pair total knee arthroplasty retrieval analysis oxidized zirconium vs CoCrMo","volume":"18","author":"Heyse","year":"2011","journal-title":"Knee"},{"key":"R10-20230814","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1007\/s11999-013-3078-4","article-title":"Oxidized zirconium versus cobalt-chromium in TKA: profilometry of retrieved femoral components","volume":"472","author":"Heyse","year":"2014","journal-title":"Clin Orthop Relat Res."},{"key":"R11-20230814","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1016\/j.knee.2013.08.015","article-title":"A minimum 5-year follow-up of an oxidized zirconium femoral prosthesis used for total knee arthroplasty","volume":"21","author":"Hofer","year":"2014","journal-title":"Knee"},{"key":"R12-20230814","doi-asserted-by":"crossref","first-page":"384","DOI":"10.1016\/j.knee.2012.10.007","article-title":"Five year survival analysis of an oxidized zirconium total knee arthroplasty","volume":"20","author":"Holland","year":"2013","journal-title":"Knee"},{"key":"R13-20230814","doi-asserted-by":"crossref","first-page":"624","DOI":"10.2106\/JBJS.I.01753","article-title":"Five-year comparison of oxidized zirconium and cobalt-chromium femoral components in total knee arthroplasty: a randomized controlled trial","volume":"93","author":"Hui","year":"2011","journal-title":"J Bone Joint Surg Am."},{"key":"R14-20230814","doi-asserted-by":"crossref","first-page":"145","DOI":"10.3109\/17453674.2013.784660","article-title":"Alternative bearings in total knee arthroplasty: risk of early revision compared to traditional bearing: an analysis of 62,177 primary cases","volume":"84","author":"Inacio","year":"2013","journal-title":"Acta Orthop"},{"key":"R15-20230814","doi-asserted-by":"crossref","first-page":"858","DOI":"10.1016\/j.knee.2014.04.005","article-title":"Oxidized zirconium femoral component for TKA: a follow-up note of a previous report at a minimum of 10 years","volume":"21","author":"Innocenti","year":"2014","journal-title":"Knee"},{"key":"R16-20230814","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1097\/00003086-198911000-00004","article-title":"Rationale of the Knee Society Clinical Rating system","volume":"248","author":"Insall","year":"1989","journal-title":"Clin Orthop Relat Res."},{"key":"R17-20230814","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1080\/01621459.1958.10501452","article-title":"Nonparametric estimation from incomplete observation","volume":"53","author":"Kaplan","year":"1958","journal-title":"J Am Stat Assoc."},{"key":"R18-20230814","doi-asserted-by":"crossref","first-page":"1296","DOI":"10.1007\/s11999-009-1179-x","article-title":"Weight of polyethylene wear particles is similar in TKAs with oxidized zirconium and cobalt-chrome prostheses","volume":"468","author":"Kim","year":"2010","journal-title":"Clin Orthop Relat Res."},{"key":"R19-20230814","doi-asserted-by":"crossref","first-page":"1221","DOI":"10.1302\/0301-620X.94B9.28854","article-title":"Comparison of the Genesis II total knee replacement with oxidized zirconium and cobalt-chromium femoral components in the same patients: a prospective, double-blind, randomized controlled study","volume":"94","author":"Kim","year":"2012","journal-title":"J Bone Joint Surg Br."},{"key":"R20-20230814","doi-asserted-by":"crossref","first-page":"2017","DOI":"10.2106\/JBJS.L.00142","article-title":"Computer-navigated versus conventional total knee arthroplasty. A prospective randomized trial","volume":"94","author":"Kim","year":"2012","journal-title":"J Bone Joint Surg Am."},{"key":"R21-20230814","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1243\/0954411971534638","article-title":"The size and shape of particulate polyethylene wear debris in total joint replacement","volume":"211","author":"Kobayashi","year":"1997","journal-title":"Proc Inst Mech Eng H."},{"key":"R22-20230814","doi-asserted-by":"crossref","first-page":"159","DOI":"10.2307\/2529310","article-title":"The measurement of observer agreement for categorical data","volume":"33","author":"Landis","year":"1977","journal-title":"Biometrics"},{"key":"R23-20230814","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1097\/01.blo.0000093003.90435.1f","article-title":"An oxidized Zr ceramic surfaced femoral components for total knee arthroplasty","volume":"416","author":"Laskin","year":"2003","journal-title":"Clin Orthop Relat Res."},{"key":"R24-20230814","doi-asserted-by":"crossref","first-page":"2161","DOI":"10.1016\/j.arth.2017.02.006","article-title":"Clinical results and survivorship of the Genesis II total knee arthroplasty at a minimum of 15 years","volume":"32","author":"McCalden","year":"2017","journal-title":"J Arthroplasty."},{"key":"R25-20230814","doi-asserted-by":"crossref","first-page":"529","DOI":"10.2106\/JBJS.M.00545","article-title":"Younger age is associated with a higher risk of early periprosthetic joint infection and aseptic mechanical failure after total knee arthroplasty","volume":"96","author":"Meehan","year":"2014","journal-title":"J Bone Joint Surg Am."},{"key":"R26-20230814","doi-asserted-by":"crossref","first-page":"680","DOI":"10.1007\/s00167-013-2724-4","article-title":"No difference in in vivo polyethylene wear particles between oxidized zirconium and cobalt-chromium femoral component in total knee arthroplasty","volume":"22","author":"Minoda","year":"2014","journal-title":"Knee Surg Sports Traumatol Arthrosc."},{"key":"R27-20230814","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1055\/s-0035-1551836","article-title":"Oxidized zirconium bearing surfaces in total knee arthroplasty: lessons learned","volume":"28","author":"Sch\u0171ttler","year":"2015","journal-title":"J Knee Surg"},{"issue":"Suppl 2","key":"R28-20230814","doi-asserted-by":"crossref","first-page":"80","DOI":"10.2106\/00004623-200100022-00004","article-title":"Wear performance of ultra-high molecular weight polyethylene on oxidized zirconium total knee femoral components","volume":"83","author":"Spector","year":"2001","journal-title":"J Bone Joint Surg Am."},{"key":"R30-20230814","doi-asserted-by":"crossref","first-page":"275","DOI":"10.2106\/JBJS.16.00092","article-title":"Twelve-year outcomes of an Oxinium total knee replacement compared with the same cobalt-chromium designs: an analysis of 17,577 prostheses from the Australian Orthopaedic Association National Joint Replacement Registry","volume":"99","author":"Vertullo","year":"2017","journal-title":"J Bone Joint Surg Am."},{"key":"R31-20230814","first-page":"176","article-title":"Simulated knee wear with cobalt chromium and oxidized zirconium knee femoral components","volume":"309","author":"White","year":"1994","journal-title":"Clin Orthop Relat Res."},{"key":"R32-20230814","doi-asserted-by":"crossref","first-page":"890","DOI":"10.1016\/S0883-5403(98)90195-4","article-title":"Assessing activity in joint replacement patients","volume":"13","author":"Zahiri","year":"1998","journal-title":"J Arthroplasty"}],"container-title":["Clinical Orthopaedics &amp; Related Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00003086-201901000-00012","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,14]],"date-time":"2023-08-14T06:01:34Z","timestamp":1691992894000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00003086-201901000-00012"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,3,28]]},"references-count":29,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1007\/s11999.0000000000000271","relation":{},"ISSN":["0009-921X"],"issn-type":[{"value":"0009-921X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,3,28]]}}}