{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T02:42:08Z","timestamp":1778726528500,"version":"3.51.4"},"reference-count":53,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2023,1,26]],"date-time":"2023-01-26T00:00:00Z","timestamp":1674691200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,1,26]],"date-time":"2023-01-26T00:00:00Z","timestamp":1674691200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Appl Biochem Biotechnol"],"published-print":{"date-parts":[[2023,7]]},"DOI":"10.1007\/s12010-023-04350-y","type":"journal-article","created":{"date-parts":[[2023,1,26]],"date-time":"2023-01-26T07:02:36Z","timestamp":1674716556000},"page":"4485-4502","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":26,"title":["A Novel Electrochemical Biosensor Based on Polyaniline-Embedded Copper Oxide Nanoparticles for High-Sensitive Paraoxon-Ethyl (PE) Detection"],"prefix":"10.1007","volume":"195","author":[{"given":"Saroj","family":"Paneru","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9118-2070","authenticated-orcid":false,"given":"Devendra","family":"Kumar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,1,26]]},"reference":[{"issue":"9","key":"4350_CR1","doi-asserted-by":"publisher","first-page":"3461","DOI":"10.1007\/s00604-017-2380-3","volume":"184","author":"M Wei","year":"2017","unstructured":"Wei, M., & Feng, S. (2017). Amperometric determination of organophosphate pesticides using a acetylcholinesterase based biosensor made from nitrogen-doped porous carbon deposited on a boron-doped diamond electrode. Microchimica Acta, 184(9), 3461\u20133468.","journal-title":"Microchimica Acta"},{"issue":"21","key":"4350_CR2","doi-asserted-by":"publisher","first-page":"24865","DOI":"10.1021\/acsami.1c04597","volume":"13","author":"U Rajaji","year":"2021","unstructured":"Rajaji, U., Chinnapaiyan, S., Chen, S. M., Govindasamy, M., Oliveira Filho, J. I. D., Khushaim, W., & Mani, V. (2021). Design and fabrication of yttrium ferrite garnet-embedded graphitic carbon nitride: A sensitive electrocatalyst for smartphone-enabled point-of-care pesticide (mesotrione) analysis in food samples. ACS Applied Materials & Interfaces, 13(21), 24865\u201324876.","journal-title":"ACS Applied Materials & Interfaces"},{"key":"4350_CR3","doi-asserted-by":"crossref","unstructured":"Ma, L., He, Y., Wang, Y., Wang, Y., Li, R., Huang, Z., ..., & Gao, J. (2019). Nanocomposites of Pt nanoparticles anchored on UiO66-NH2 as carriers to construct acetylcholinesterase biosensors for organophosphorus pesticide detection.\u00a0Electrochimica Acta,\u00a0318, 525\u2013533.","DOI":"10.1016\/j.electacta.2019.06.110"},{"key":"4350_CR4","doi-asserted-by":"crossref","unstructured":"Zhang, Y., Liu, H., Yang, Z., Ji, S., Wang, J., Pang, P., ..., & Yang, W. (2015). An acetylcholinesterase inhibition biosensor based on a reduced graphene oxide\/silver nanocluster\/chitosan nanocomposite for detection of organophosphorus pesticides.\u00a0Analytical methods,\u00a07(15), 6213\u20136219.","DOI":"10.1039\/C5AY01439E"},{"key":"4350_CR5","doi-asserted-by":"crossref","unstructured":"Shin, Y., Lee, J., Lee, J., Lee, J., Kim, E., Liu, K. H., ..., & Kim, J. H. (2018). Validation of a multiresidue analysis method for 379 pesticides in human serum using liquid chromatography\u2013tandem mass spectrometry.\u00a0Journal of agricultural and food chemistry,\u00a066(13), 3550\u20133560.","DOI":"10.1021\/acs.jafc.8b00094"},{"issue":"1\u20132","key":"4350_CR6","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1016\/j.aca.2009.09.044","volume":"655","author":"L He","year":"2009","unstructured":"He, L., Luo, X., Xie, H., Wang, C., Jiang, X., & Lu, K. (2009). Ionic liquid-based dispersive liquid\u2013liquid microextraction followed high-performance liquid chromatography for the determination of organophosphorus pesticides in water sample. Analytica chimica acta, 655(1\u20132), 52\u201359.","journal-title":"Analytica chimica acta"},{"issue":"5","key":"4350_CR7","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1093\/jat\/bky004","volume":"42","author":"C Santos","year":"2018","unstructured":"Santos, C., Oppolzer, D., Gon\u00e7alves, A., Barroso, M., & Gallardo, E. (2018). Determination of organophosphorous pesticides in blood using microextraction in packed sorbent and gas chromatography\u2013tandem mass spectrometry. Journal of analytical toxicology, 42(5), 321\u2013329.","journal-title":"Journal of analytical toxicology"},{"key":"4350_CR8","doi-asserted-by":"publisher","first-page":"268","DOI":"10.1016\/j.compositesb.2018.10.042","volume":"160","author":"U Rajaji","year":"2019","unstructured":"Rajaji, U., Murugan, K., Chen, S. M., Govindasamy, M., Chen, T. W., & Lin, P. H. (2019). Graphene oxide encapsulated 3D porous chalcopyrite (CuFeS2) nanocomposite as an emerging electrocatalyst for agro-hazardous (methyl paraoxon) detection in vegetables. Composites Part B: Engineering, 160, 268\u2013276.","journal-title":"Composites Part B: Engineering"},{"issue":"1","key":"4350_CR9","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/srep46471","volume":"7","author":"M Govindasamy","year":"2017","unstructured":"Govindasamy, M., Mani, V., Chen, S. M., Chen, T. W., & Sundramoorthy, A. K. (2017). Methyl parathion detection in vegetables and fruits using silver@ graphene nanoribbons nanocomposite modified screen printed electrode. Scientific reports, 7(1), 1\u201311.","journal-title":"Scientific reports"},{"issue":"9","key":"4350_CR10","doi-asserted-by":"publisher","first-page":"B403","DOI":"10.1149\/2.0371709jes","volume":"164","author":"M Govindasamy","year":"2017","unstructured":"Govindasamy, M., Umamaheswari, R., Chen, S. M., Mani, V., & Su, C. (2017). Graphene oxide nanoribbons film modified screen-printed carbon electrode for real-time detection of methyl parathion in food samples. Journal of The Electrochemical Society, 164(9), B403.","journal-title":"Journal of The Electrochemical Society"},{"key":"4350_CR11","doi-asserted-by":"crossref","unstructured":"Govindasamy, M., Rajaji, U., Chen, S. M., Kumaravel, S., Chen, T. W., Al-Hemaid, F. M., ..., & Elshikh, M. S. (2018). Detection of pesticide residues (Fenitrothion) in fruit samples based on niobium carbide@ molybdenum nanocomposite: An electrocatalytic approach.\u00a0Analytica Chimica Acta,\u00a01030, 52\u201360.","DOI":"10.1016\/j.aca.2018.05.044"},{"issue":"3","key":"4350_CR12","doi-asserted-by":"publisher","first-page":"725","DOI":"10.1007\/s00604-016-2062-6","volume":"184","author":"M Govindasamy","year":"2017","unstructured":"Govindasamy, M., Chen, S. M., Mani, V., Akilarasan, M., Kogularasu, S., & Subramani, B. (2017). Nanocomposites composed of layered molybdenum disulfide and graphene for highly sensitive amperometric determination of methyl parathion. Microchimica Acta, 184(3), 725\u2013733.","journal-title":"Microchimica Acta"},{"key":"4350_CR13","doi-asserted-by":"publisher","first-page":"290","DOI":"10.1016\/j.snb.2015.01.112","volume":"211","author":"M Wei","year":"2015","unstructured":"Wei, M., & Wang, J. (2015). A novel acetylcholinesterase biosensor based on ionic liquids-AuNPs-porous carbon composite matrix for detection of organophosphate pesticides. Sensors and Actuators B: Chemical, 211, 290\u2013296.","journal-title":"Sensors and Actuators B: Chemical"},{"issue":"8","key":"4350_CR14","doi-asserted-by":"publisher","first-page":"1405","DOI":"10.1016\/j.bios.2005.07.012","volume":"21","author":"A Amine","year":"2006","unstructured":"Amine, A., Mohammadi, H., Bourais, I., & Palleschi, G. (2006). Enzyme inhibition-based biosensors for food safety and environmental monitoring. Biosensors and Bioelectronics, 21(8), 1405\u20131423.","journal-title":"Biosensors and Bioelectronics"},{"issue":"1","key":"4350_CR15","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1002\/elan.200403118","volume":"17","author":"KA Joshi","year":"2005","unstructured":"Joshi, K. A., Tang, J., Haddon, R., Wang, J., Chen, W., & Mulchandani, A. (2005). A disposable biosensor for organophosphorus nerve agents based on carbon nanotubes modified thick film strip electrode. Electroanalysis: An International Journal Devoted to Fundamental and Practical Aspects of Electroanalysis, 17(1), 54\u201358.","journal-title":"Electroanalysis: An International Journal Devoted to Fundamental and Practical Aspects of Electroanalysis"},{"key":"4350_CR16","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1016\/j.snb.2014.08.058","volume":"205","author":"M Kesik","year":"2014","unstructured":"Kesik, M., Kanik, F. E., Turan, J., Kolb, M., Timur, S., Bahadir, M., & Toppare, L. (2014). An acetylcholinesterase biosensor based on a conducting polymer using multiwalled carbon nanotubes for amperometric detection of organophosphorous pesticides. Sensors and Actuators B: Chemical, 205, 39\u201349.","journal-title":"Sensors and Actuators B: Chemical"},{"key":"4350_CR17","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1016\/j.bios.2013.08.050","volume":"52","author":"RR Dutta","year":"2014","unstructured":"Dutta, R. R., & Puzari, P. (2014). Amperometric biosensing of organophosphate and organocarbamate pesticides utilizing polypyrrole entrapped acetylcholinesterase electrode. Biosensors and Bioelectronics, 52, 166\u2013172.","journal-title":"Biosensors and Bioelectronics"},{"key":"4350_CR18","doi-asserted-by":"crossref","unstructured":"Zhang, P., Sun, T., Rong, S., Zeng, D., Yu, H., Zhang, Z., ..., & Pan, H. (2019). A sensitive amperometric AChE-biosensor for organophosphate pesticides detection based on conjugated polymer and Ag-rGO-NH2 nanocomposite.\u00a0Bioelectrochemistry,\u00a0127, 163\u2013170.","DOI":"10.1016\/j.bioelechem.2019.02.003"},{"key":"4350_CR19","doi-asserted-by":"publisher","first-page":"278","DOI":"10.1016\/j.snb.2016.01.034","volume":"228","author":"J Turan","year":"2016","unstructured":"Turan, J., Kesik, M., Soylemez, S., Goker, S., Coskun, S., Unalan, H. E., & Toppare, L. (2016). An effective surface design based on a conjugated polymer and silver nanowires for the detection of paraoxon in tap water and milk. Sensors and Actuators B: Chemical, 228, 278\u2013286.","journal-title":"Sensors and Actuators B: Chemical"},{"key":"4350_CR20","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1016\/j.jelechem.2016.05.037","volume":"775","author":"N Kaur","year":"2016","unstructured":"Kaur, N., Thakur, H., & Prabhakar, N. (2016). Conducting polymer and multi-walled carbon nanotubes nanocomposites based amperometric biosensor for detection of organophosphate. Journal of Electroanalytical Chemistry, 775, 121\u2013128.","journal-title":"Journal of Electroanalytical Chemistry"},{"key":"4350_CR21","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1016\/j.bios.2014.01.017","volume":"56","author":"L Fang","year":"2014","unstructured":"Fang, L., Liang, B., Yang, G., Hu, Y., Zhu, Q., & Ye, X. (2014). Study of glucose biosensor lifetime improvement in 37 C serum based on PANI enzyme immobilization and PLGA biodegradable membrane. Biosensors and Bioelectronics, 56, 91\u201396.","journal-title":"Biosensors and Bioelectronics"},{"key":"4350_CR22","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1016\/j.jelechem.2016.10.033","volume":"782","author":"J Lai","year":"2016","unstructured":"Lai, J., Yi, Y., Zhu, P., Shen, J., Wu, K., Zhang, L., & Liu, J. (2016). Polyaniline-based glucose biosensor: A review. Journal of Electroanalytical Chemistry, 782, 138\u2013153.","journal-title":"Journal of Electroanalytical Chemistry"},{"key":"4350_CR23","doi-asserted-by":"publisher","first-page":"813","DOI":"10.1016\/j.snb.2017.11.161","volume":"258","author":"L He","year":"2018","unstructured":"He, L., Cui, B., Liu, J., Song, Y., Wang, M., Peng, D., & Zhang, Z. (2018). Novel electrochemical biosensor based on core-shell nanostructured composite of hollow carbon spheres and polyaniline for sensitively detecting malathion. Sensors and Actuators B: Chemical, 258, 813\u2013821.","journal-title":"Sensors and Actuators B: Chemical"},{"key":"4350_CR24","doi-asserted-by":"publisher","first-page":"638","DOI":"10.1016\/j.bios.2016.10.038","volume":"92","author":"H Al-Sagur","year":"2017","unstructured":"Al-Sagur, H., Komathi, S., Khan, M. A., Gurek, A. G., & Hassan, A. (2017). A novel glucose sensor using lutetium phthalocyanine as redox mediator in reduced graphene oxide conducting polymer multifunctional hydrogel. Biosensors and Bioelectronics, 92, 638\u2013645.","journal-title":"Biosensors and Bioelectronics"},{"key":"4350_CR25","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1016\/j.biomaterials.2017.04.010","volume":"133","author":"L Bai","year":"2017","unstructured":"Bai, L., Chen, Y., Bai, Y., Chen, Y., Zhou, J., & Huang, A. (2017). Fullerene-doped polyaniline as new redox nanoprobe and catalyst in electrochemical aptasensor for ultrasensitive detection of Mycobacterium tuberculosis MPT64 antigen in human serum. Biomaterials, 133, 11\u201319.","journal-title":"Biomaterials"},{"key":"4350_CR26","doi-asserted-by":"crossref","unstructured":"Zhao, Y., Tan, R., Yang, J., Wang, K., Gao, R., Liu, D., ..., & Pan, F. (2017). 3D-hybrid material design with electron\/lithium-ion dual-conductivity for high-performance Li-sulfur batteries.\u00a0Journal of Power Sources,\u00a0340, 160\u2013166.","DOI":"10.1016\/j.jpowsour.2016.11.067"},{"issue":"2","key":"4350_CR27","doi-asserted-by":"publisher","first-page":"790","DOI":"10.1016\/j.bios.2010.06.023","volume":"26","author":"A Kausaite-Minkstimiene","year":"2010","unstructured":"Kausaite-Minkstimiene, A., Mazeiko, V., Ramanaviciene, A., & Ramanavicius, A. (2010). Enzymatically synthesized polyaniline layer for extension of linear detection region of amperometric glucose biosensor. Biosensors and Bioelectronics, 26(2), 790\u2013797.","journal-title":"Biosensors and Bioelectronics"},{"key":"4350_CR28","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1016\/j.enzmictec.2014.08.001","volume":"66","author":"RE Kim","year":"2014","unstructured":"Kim, R. E., Hong, S. G., Ha, S., & Kim, J. (2014). Enzyme adsorption, precipitation and crosslinking of glucose oxidase and laccase on polyaniline nanofibers for highly stable enzymatic biofuel cells. Enzyme and microbial technology, 66, 35\u201341.","journal-title":"Enzyme and microbial technology"},{"key":"4350_CR29","doi-asserted-by":"publisher","first-page":"562","DOI":"10.1016\/j.snb.2013.09.049","volume":"190","author":"Q Xu","year":"2014","unstructured":"Xu, Q., Gu, S. X., Jin, L., Zhou, Y. E., Yang, Z., Wang, W., & Hu, X. (2014). Graphene\/polyaniline\/gold nanoparticles nanocomposite for the direct electron transfer of glucose oxidase and glucose biosensing. Sensors and Actuators B: Chemical, 190, 562\u2013569.","journal-title":"Sensors and Actuators B: Chemical"},{"key":"4350_CR30","doi-asserted-by":"crossref","unstructured":"Cai, Q., Xu, B., Ye, L., Di, Z., Zhang, J., Jin, Q., ..., & Chen, X. (2014). Immobilization of biomolecules on cysteamine-modified polyaniline film for highly sensitive biosensing.\u00a0Talanta,\u00a0120, 462\u2013469.","DOI":"10.1016\/j.talanta.2013.11.013"},{"key":"4350_CR31","doi-asserted-by":"publisher","first-page":"126784","DOI":"10.1016\/j.foodchem.2020.126784","volume":"323","author":"S Nagabooshanam","year":"2020","unstructured":"Nagabooshanam, S., John, A. T., Wadhwa, S., Mathur, A., Krishnamurthy, S., & Bharadwaj, L. M. (2020). Electro-deposited nano-webbed structures based on polyaniline\/multi walled carbon nanotubes for enzymatic detection of organophosphates. Food chemistry, 323, 126784.","journal-title":"Food chemistry"},{"issue":"9","key":"4350_CR32","doi-asserted-by":"publisher","first-page":"6899","DOI":"10.1039\/C5NJ01049G","volume":"39","author":"B Kaur","year":"2015","unstructured":"Kaur, B., & Srivastava, R. (2015). A polyaniline\u2013zeolite nanocomposite material based acetylcholinesterase biosensor for the sensitive detection of acetylcholine and organophosphates. New Journal of Chemistry, 39(9), 6899\u20136906.","journal-title":"New Journal of Chemistry"},{"key":"4350_CR33","doi-asserted-by":"crossref","unstructured":"Thakur, D., Pandey, C. M., & Kumar, D. (2022). Highly sensitive enzymatic biosensor based on polyaniline-wrapped titanium dioxide nanohybrid for fish freshness detection. Applied Biochemistry and Biotechnology, 194, 3765\u20133778.","DOI":"10.1007\/s12010-022-03931-7"},{"key":"4350_CR34","doi-asserted-by":"publisher","first-page":"875","DOI":"10.1016\/j.snb.2017.03.108","volume":"247","author":"D Zhang","year":"2017","unstructured":"Zhang, D., Jiang, C., Liu, J., & Cao, Y. (2017). Carbon monoxide gas sensing at room temperature using copper oxide-decorated graphene hybrid nanocomposite prepared by layer-by-layer self-assembly. Sensors and Actuators B: Chemical, 247, 875\u2013882.","journal-title":"Sensors and Actuators B: Chemical"},{"issue":"1","key":"4350_CR35","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1016\/j.bios.2012.03.043","volume":"38","author":"K Jindal","year":"2012","unstructured":"Jindal, K., Tomar, M., & Gupta, V. (2012). CuO thin film based uric acid biosensor with enhanced response characteristics. Biosensors and Bioelectronics, 38(1), 11\u201318.","journal-title":"Biosensors and Bioelectronics"},{"key":"4350_CR36","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1016\/j.electacta.2014.11.171","volume":"152","author":"K Wang","year":"2015","unstructured":"Wang, K., Dong, X., Zhao, C., Qian, X., & Xu, Y. (2015). Facile synthesis of Cu2O\/CuO\/RGO nanocomposite and its superior cyclability in supercapacitor. Electrochimica Acta, 152, 433\u2013442.","journal-title":"Electrochimica Acta"},{"key":"4350_CR37","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1016\/j.jallcom.2019.01.349","volume":"788","author":"M He","year":"2019","unstructured":"He, M., Xie, L., Zhao, X., Hu, X., Li, S., & Zhu, Z. G. (2019). Highly sensitive and selective H2S gas sensors based on flower-like WO3\/CuO composites operating at low\/room temperature. Journal of Alloys and Compounds, 788, 36\u201343.","journal-title":"Journal of Alloys and Compounds"},{"key":"4350_CR38","doi-asserted-by":"crossref","unstructured":"Bao, J., Huang, T., Wang, Z., Yang, H., Geng, X., Xu, G., ..., & Hou, C. (2019). 3D graphene\/copper oxide nano-flowers based acetylcholinesterase biosensor for sensitive detection of organophosphate pesticides.\u00a0Sensors and Actuators B: Chemical,\u00a0279, 95\u2013101.","DOI":"10.1016\/j.snb.2018.09.118"},{"key":"4350_CR39","doi-asserted-by":"publisher","first-page":"129875","DOI":"10.1016\/j.snb.2021.129875","volume":"339","author":"LF Loguercio","year":"2021","unstructured":"Loguercio, L. F., Thesing, A., Demingos, P., de Albuquerque, C. D., Rodrigues, R. S., Brolo, A. G., & Santos, J. F. (2021). Efficient acetylcholinesterase immobilization for improved electrochemical performance in polypyrrole nanocomposite-based biosensors for carbaryl pesticide. Sensors and Actuators B: Chemical, 339, 129875.","journal-title":"Sensors and Actuators B: Chemical"},{"key":"4350_CR40","doi-asserted-by":"crossref","unstructured":"Iqbal, S., Javed, M., Bahadur, A., Qamar, M. A., Ahmad, M., Shoaib, M., ..., & Li, H. (2020). Controlled synthesis of Ag-doped CuO nanoparticles as a core with poly (acrylic acid) microgel shell for efficient removal of methylene blue under visible light.\u00a0Journal of Materials Science: Materials in Electronics,\u00a031(11), 8423\u20138435.","DOI":"10.1007\/s10854-020-03377-9"},{"issue":"49","key":"4350_CR41","first-page":"1989","volume":"1","author":"M Nagaraja","year":"2022","unstructured":"Nagaraja, M., Prashanth, S., Pattar, J., Mahesh, H. M., & Rajanna, K. (2022). Polyaniline-CuO nanocomposite: Electrical, structural and sensor properties. Materials Today: Proceedings, 1(49), 1989\u20131992.","journal-title":"Materials Today: Proceedings."},{"key":"4350_CR42","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1016\/j.molstruc.2017.04.104","volume":"1143","author":"AA Ferreira","year":"2017","unstructured":"Ferreira, A. A., & Sanches, E. A. (2017). Multimorphologies of hydrochloride polyaniline synthesized by conventional and interfacial polymerization. Journal of Molecular Structure, 1143, 294\u2013305.","journal-title":"Journal of Molecular Structure"},{"key":"4350_CR43","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1016\/j.molstruc.2017.09.084","volume":"1153","author":"VS de Souza","year":"2018","unstructured":"de Souza, V. S., da Frota, H. O., & Sanches, E. A. (2018). Polyaniline-CuO hybrid nanocomposite with enhanced electrical conductivity. Journal of Molecular Structure, 1153, 20\u201327.","journal-title":"Journal of Molecular Structure"},{"key":"4350_CR44","first-page":"00104","volume":"5","author":"A Mehto","year":"2017","unstructured":"Mehto, A., Mehto, V. R., Chauhan, J., Singh, I., & Pandey, R. (2017). Preparation and characterization of polyaniline\/ZnO composite sensor. J. Nanomed. Res, 5, 00104.","journal-title":"J. Nanomed. Res"},{"issue":"5","key":"4350_CR45","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s00604-020-04233-7","volume":"187","author":"O Jalil","year":"2020","unstructured":"Jalil, O., Pandey, C. M., & Kumar, D. (2020). Electrochemical biosensor for the epithelial cancer biomarker EpCAM based on reduced graphene oxide modified with nanostructured titanium dioxide. Microchimica Acta, 187(5), 1\u20139.","journal-title":"Microchimica Acta"},{"key":"4350_CR46","doi-asserted-by":"crossref","unstructured":"Verma, S., Pandey, C. M., & Kumar, D. (2022). A highly efficient rGO grafted MoS 2 nanocomposite for dye adsorption and electrochemical detection of hydroquinone in wastewater. New Journal of Chemistry, 46(44), 21190\u201321200.","DOI":"10.1039\/D2NJ04285A"},{"key":"4350_CR47","doi-asserted-by":"publisher","first-page":"107392","DOI":"10.1016\/j.bioelechem.2019.107392","volume":"131","author":"L Jia","year":"2020","unstructured":"Jia, L., Zhou, Y., Wu, K., Feng, Q., Wang, C., & He, P. (2020). Acetylcholinesterase modified AuNPs-MoS2-rGO\/PI flexible film biosensor: Towards efficient fabrication and application in paraoxon detection. Bioelectrochemistry, 131, 107392.","journal-title":"Bioelectrochemistry"},{"issue":"220672","key":"4350_CR48","first-page":"2","volume":"17","author":"B Xiao","year":"2022","unstructured":"Xiao, B. (2022). Electrochemical sensor based on Bimetallic phosphosulfide Zn\u2013Ni\u2013P\u2013S Nanocomposite-reduced graphene oxide for determination of paraoxon ethyl in agriculture wastewater. International Journal of Electrochemical Science, 17(220672), 2.","journal-title":"International Journal of Electrochemical Science"},{"issue":"27","key":"4350_CR49","doi-asserted-by":"publisher","first-page":"3439","DOI":"10.1039\/C9AY00852G","volume":"11","author":"QT Hua","year":"2019","unstructured":"Hua, Q. T., Ruecha, N., Hiruta, Y., & Citterio, D. (2019). Disposable electrochemical biosensor based on surface-modified screen-printed electrodes for organophosphorus pesticide analysis. Analytical Methods, 11(27), 3439\u20133445.","journal-title":"Analytical Methods"},{"issue":"17","key":"4350_CR50","doi-asserted-by":"publisher","first-page":"1900632","DOI":"10.1002\/smll.201900632","volume":"15","author":"Y Wu","year":"2019","unstructured":"Wu, Y., Jiao, L., Xu, W., Gu, W., Zhu, C., Du, D., & Lin, Y. (2019). Polydopamine-capped bimetallic AuPt hydrogels enable robust biosensor for organophosphorus pesticide detection. Small, 15(17), 1900632.","journal-title":"Small"},{"key":"4350_CR51","doi-asserted-by":"publisher","first-page":"290","DOI":"10.1016\/j.bios.2017.09.019","volume":"100","author":"LF Sgobbi","year":"2018","unstructured":"Sgobbi, L. F., & Machado, S. A. (2018). Functionalized polyacrylamide as an acetylcholinesterase-inspired biomimetic device for electrochemical sensing of organophosphorus pesticides. Biosensors and Bioelectronics, 100, 290\u2013297.","journal-title":"Biosensors and Bioelectronics"},{"issue":"7","key":"4350_CR52","doi-asserted-by":"publisher","first-page":"8615","DOI":"10.1021\/acssuschemeng.8b00936","volume":"6","author":"R Karthik","year":"2018","unstructured":"Karthik, R., Kumar, J. V., Chen, S. M., Kokulnathan, T., Yang, H. Y., & Muthuraj, V. (2018). Design of novel ytterbium molybdate nanoflakes anchored carbon nanofibers: Challenging sustainable catalyst for the detection and degradation of assassination weapon (Paraoxon-Ethyl). ACS Sustainable Chemistry & Engineering, 6(7), 8615\u20138630.","journal-title":"ACS Sustainable Chemistry & Engineering"},{"issue":"3","key":"4350_CR53","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s00604-018-3206-7","volume":"186","author":"B Mutharani","year":"2019","unstructured":"Mutharani, B., Ranganathan, P., Chen, S. M., & Karuppiah, C. (2019). Enzyme-free electrochemical detection of nanomolar levels of the organophosphorus pesticide paraoxon-ethyl by using a poly (N-isopropyl acrylamide)-chitosan microgel decorated with palladium nanoparticles. Microchimica Acta, 186(3), 1\u201311.","journal-title":"Microchimica Acta"}],"container-title":["Applied Biochemistry and Biotechnology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12010-023-04350-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12010-023-04350-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12010-023-04350-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,6,30]],"date-time":"2023-06-30T10:40:26Z","timestamp":1688121626000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12010-023-04350-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1,26]]},"references-count":53,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2023,7]]}},"alternative-id":["4350"],"URL":"https:\/\/doi.org\/10.1007\/s12010-023-04350-y","relation":{},"ISSN":["0273-2289","1559-0291"],"issn-type":[{"value":"0273-2289","type":"print"},{"value":"1559-0291","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1,26]]},"assertion":[{"value":"10 January 2023","order":1,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 January 2023","order":2,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics Approval"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to Participate"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for Publication"}},{"value":"The authors declare no competing interests.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}]}}