{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T22:42:09Z","timestamp":1780353729241,"version":"3.54.1"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2016,7,15]],"date-time":"2016-07-15T00:00:00Z","timestamp":1468540800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Forensic Sci Med Pathol"],"published-print":{"date-parts":[[2016,9]]},"DOI":"10.1007\/s12024-016-9798-5","type":"journal-article","created":{"date-parts":[[2016,7,15]],"date-time":"2016-07-15T11:50:19Z","timestamp":1468583419000},"page":"336-342","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Automatic entry point planning for robotic post-mortem CT-based needle placement"],"prefix":"10.1007","volume":"12","author":[{"given":"Lars C.","family":"Ebert","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"F\u00fcrst","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wolfgang","family":"Ptacek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas D.","family":"Ruder","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dominic","family":"Gascho","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wolf","family":"Schweitzer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael J.","family":"Thali","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patricia M.","family":"Flach","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2016,7,15]]},"reference":[{"key":"9798_CR1","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1016\/j.forsciint.2006.05.035","volume":"166","author":"E Aghayev","year":"2007","unstructured":"Aghayev E, Thali MJ, Sonnenschein M, Jackowski C, Dirnhofer R, Vock P. Post-mortem tissue sampling using computed tomography guidance. Forensic Sci Int. 2007;166:199\u2013203.","journal-title":"Forensic Sci Int"},{"key":"9798_CR2","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/j.legalmed.2014.10.002","volume":"17","author":"H Hyodoh","year":"2015","unstructured":"Hyodoh H, Shimizu J, Mizuo K, Okazaki S, Watanabe S, Inoue H. CT-guided percutaneous needle placement in forensic medicine. Leg Med. 2015;17:79\u201381.","journal-title":"Leg Med"},{"key":"9798_CR3","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1111\/1556-4029.12329","volume":"59","author":"RM Martinez","year":"2014","unstructured":"Martinez RM, Ptacek W, Schweitzer W, Kronreif G, F\u00fcrst M, Thali MJ, et al. CT-guided, minimally invasive, postmortem needle biopsy using the B-Rob II needle-positioning robot. J Forensic Sci. 2014;59:517\u201321.","journal-title":"J Forensic Sci"},{"key":"9798_CR4","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1002\/rcs.285","volume":"6","author":"LC Ebert","year":"2010","unstructured":"Ebert LC, Ptacek W, Naether S, F\u00fcrst M, Ross S, Buck U, et al. Virtobot\u2014a multi-functional robotic system for 3D surface scanning and automatic post mortem biopsy. Int J Med Robot Comput Assist Surg. 2010;6:18\u201327.","journal-title":"Int J Med Robot Comput Assist Surg"},{"key":"9798_CR5","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1007\/s12024-013-9520-9","volume":"10","author":"LC Ebert","year":"2014","unstructured":"Ebert LC, Ptacek W, Breitbeck R, F\u00fcrst M, Kronreif G, Martinez RM, et al. Virtobot : the future of automated surface documentation and CT-guided needle placement in forensic medicine. Forensic Sci Med Pathol. 2014;10:179\u201386.","journal-title":"Forensic Sci Med Pathol"},{"key":"9798_CR6","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1007\/s11548-011-0651-8","volume":"7","author":"C Essert","year":"2011","unstructured":"Essert C, Haegelen C, Lalys F, Abadie A, Jannin P. Automatic computation of electrode trajectories for deep brain stimulation: a hybrid symbolic and numerical approach. Int J Comput Assist Radiol Surg. 2011;7:517\u201332.","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"9798_CR7","doi-asserted-by":"crossref","first-page":"3246","DOI":"10.1118\/1.3590374","volume":"38","author":"A Seitel","year":"2011","unstructured":"Seitel A, Engel M, Sommer CM, Radeleff BA, Essert-Villard C, Baegert C, et al. Computer-assisted trajectory planning for percutaneous needle insertions. Med Phys. 2011;38:3246\u201359.","journal-title":"Med Phys"},{"key":"9798_CR8","doi-asserted-by":"publisher","unstructured":"Shamir RR, Joskowicz L, Antiga L, Foroni RI, Shoshan Y. Trajectory planning method for reduced patient risk in image-guided neurosurgery: concept and preliminary results. 2010. p. 76250I\u201376250I\u20138. 10.1117\/12.843991 . Accessed 6 Jan 2016.","DOI":"10.1117\/12.843991"},{"key":"9798_CR9","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1146\/annurev.bioeng.2.1.315","volume":"2","author":"DL Pham","year":"2000","unstructured":"Pham DL, Xu C, Prince JL. Current methods in medical image segmentation. Annu Rev Biomed Eng. 2000;2:315\u201337.","journal-title":"Annu Rev Biomed Eng"},{"key":"9798_CR10","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1007\/s11548-008-0164-2","volume":"3","author":"S Shah","year":"2008","unstructured":"Shah S, Kapoor A, Ding J, Guion P, Petrisor D, Karanian J, et al. Robotically assisted needle driver: evaluation of safety release, force profiles, and needle spin in a swine abdominal model. Int J Comput Assist Radiol Surg. 2008;3:173\u20139.","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"9798_CR11","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1109\/MSPEC.2013.6565554","volume":"50","author":"TS Perry","year":"2013","unstructured":"Perry TS. Profile: veebot [Resources_Start-ups]. IEEE Spectr. 2013;50:23.","journal-title":"IEEE Spectr"},{"key":"9798_CR12","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1109\/34.295913","volume":"16","author":"R Adams","year":"1994","unstructured":"Adams R, Bischof L. Seeded region growing. IEEE Trans Pattern Anal Mach Intell. 1994;16:641\u20137.","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"key":"9798_CR13","doi-asserted-by":"publisher","unstructured":"Lorensen WE, Cline HE. Marching cubes: A high resolution 3D surface construction algorithm. In: Proceedings of the 14th annual conference on computer graphics and interactive techniques. New York, NY: ACM; 1987. p. 163\u2013169. 10.1145\/37401.37422 . Accessed 30 April 2015.","DOI":"10.1145\/37401.37422"},{"key":"9798_CR14","doi-asserted-by":"publisher","unstructured":"Gottschalk S, Lin MC, Manocha D. OBBTree: a hierarchical structure for rapid interference detection. In: Proceedings of the 23rd annual conference on computer graphics and interactive techniques. New York, NY: ACM; 1996. p. 171\u2013180. 10.1145\/237170.237244 . Accessed 30 April 2015.","DOI":"10.1145\/237170.237244"},{"key":"9798_CR15","doi-asserted-by":"crossref","first-page":"1249","DOI":"10.1007\/s00216-015-9234-9","volume":"4","author":"SN Staeheli","year":"2016","unstructured":"Staeheli SN, Gascho D, Fornaro J, Laberke P, Ebert LC, Martinez RM, et al. Development of CT-guided biopsy sampling for time-dependent postmortem redistribution investigations in blood and alternative matrices\u2014proof of concept and application on two cases. Anal Bioanal Chem. 2016;4:1249\u201358.","journal-title":"Anal Bioanal Chem"},{"key":"9798_CR16","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1007\/s10278-009-9176-x","volume":"23","author":"S Banik","year":"2010","unstructured":"Banik S, Rangayyan RM, Boag GS. Automatic segmentation of the ribs, the vertebral column, and the spinal canal in pediatric computed tomographic images. J Digit Imaging. 2010;23:301\u201322.","journal-title":"J Digit Imaging"}],"container-title":["Forensic Science, Medicine, and Pathology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12024-016-9798-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s12024-016-9798-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12024-016-9798-5","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,9,24]],"date-time":"2020-09-24T01:06:52Z","timestamp":1600909612000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s12024-016-9798-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,7,15]]},"references-count":16,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2016,9]]}},"alternative-id":["9798"],"URL":"https:\/\/doi.org\/10.1007\/s12024-016-9798-5","relation":{},"ISSN":["1547-769X","1556-2891"],"issn-type":[{"value":"1547-769X","type":"print"},{"value":"1556-2891","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,7,15]]}}}