{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T03:54:51Z","timestamp":1793332491400,"version":"4.5.0"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2021,6,9]],"date-time":"2021-06-09T00:00:00Z","timestamp":1623196800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,6,9]],"date-time":"2021-06-09T00:00:00Z","timestamp":1623196800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100006447","name":"Universit\u00e4t Z\u00fcrich","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100006447","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Forensic Sci Med Pathol"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The computed tomography (CT) scan of a 19-year-old man who died from an occipito-frontal gunshot wound presented an impressive radiating fracture line where the entire sagittal suture burst due to the high intracranial pressure that arose from a near-contact shot from a 9\u00a0mm bullet fired from a Glock 17 pistol. Photorealistic depictions of the radiating fracture lines along the cranial bones were created using three-dimensional reconstruction methods, such as the novel cinematic rendering technique that simulates the propagation and interaction of light when it passes through volumetric data. Since the brain had collapsed, depiction of soft tissue was insufficient on CT images. An additional magnetic resonance imaging (MRI) examination was performed, which enabled the diagnostic assessment of cerebral injuries.<\/jats:p>","DOI":"10.1007\/s12024-021-00387-9","type":"journal-article","created":{"date-parts":[[2021,6,9]],"date-time":"2021-06-09T08:06:48Z","timestamp":1623226008000},"page":"726-729","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Cinematic rendering of a burst sagittal suture caused by an occipito-frontal gunshot wound"],"prefix":"10.1007","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9004-4362","authenticated-orcid":false,"given":"Dominic","family":"Gascho","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael J.","family":"Thali","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rosa M.","family":"Martinez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephan A.","family":"Bolliger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,6,9]]},"reference":[{"key":"387_CR1","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1177\/0025802417747167","volume":"58","author":"D Gascho","year":"2018","unstructured":"Gascho D, Thali MJ, Niemann T. Post-mortem computed tomography: technical principles and recommended parameter settings for high-resolution imaging. Med Sci Law. 2018;58:70\u201382.","journal-title":"Med Sci Law"},{"key":"387_CR2","doi-asserted-by":"publisher","first-page":"233","DOI":"10.2214\/AJR.16.16499","volume":"208","author":"LC Ebert","year":"2016","unstructured":"Ebert LC, Schweitzer W, Gascho D, Ruder TD, Flach PM, Thali MJ, et al. Forensic 3D visualization of ct data using cinematic volume rendering: a preliminary study. Am J Roentgenol. 2016;208:233\u201340.","journal-title":"Am J Roentgenol"},{"key":"387_CR3","doi-asserted-by":"publisher","first-page":"370","DOI":"10.2214\/AJR.17.17850","volume":"209","author":"M Eid","year":"2017","unstructured":"Eid M, De Cecco CN, Nance JW, Caruso D, Albrecht MH, Spandorfer AJ, et al. Cinematic rendering in CT: a novel, lifelike 3D visualization technique. Am J Roentgenol. 2017;209:370\u20139.","journal-title":"Am J Roentgenol"},{"key":"387_CR4","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1007\/s12024-019-00199-y","volume":"16","author":"D Gascho","year":"2020","unstructured":"Gascho D, Tappero C, Zoelch N, Deininger-Czermak E, Richter H, Thali MJ, et al. Synergy of CT and MRI in detecting trajectories of lodged bullets in decedents and potential hazards concerning the heating and movement of bullets during MRI. Forensic Sci Med Pathol. 2020;16:20\u201331.","journal-title":"Forensic Sci Med Pathol"},{"key":"387_CR5","volume-title":"Gunshot wounds: Practical aspects of firearms, ballistics, and forensic techniques","author":"VJMD DiMaio","year":"1999","unstructured":"DiMaio VJMD. Gunshot wounds: practical aspects of firearms, ballistics, and forensic techniques. Boca Raton: CRC-Press; 1999."},{"key":"387_CR6","volume-title":"Wound ballistics: Basics and applications","year":"2011","unstructured":"Kneubuehl B, editor. Wound ballistics: basics and applications. Berlin Heidelberg: Springer-Verlag; 2011."},{"key":"387_CR7","doi-asserted-by":"publisher","first-page":"140","DOI":"10.1007\/BF01508103","volume":"4","author":"JA Stone","year":"1997","unstructured":"Stone JA, Slone HW, Yu JS, Irsik RD, Spigos DG. Gunshot wounds of the brain: influence of ballistics and predictors of outcome by computed tomography. Emerg Radiol. 1997;4:140\u20139.","journal-title":"Emerg Radiol"},{"key":"387_CR8","doi-asserted-by":"publisher","first-page":"e1","DOI":"10.1016\/j.forsciint.2014.08.001","volume":"244","author":"A Viero","year":"2014","unstructured":"Viero A, Giraudo C, Cecchetto G, Muscovich C, Favretto D, Puglisi M, et al. An unusual case of \u201cdyadic-death\u201d with a single gunshot. Forensic Sci Int. 2014;244:e1-5.","journal-title":"Forensic Sci Int"},{"key":"387_CR9","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1016\/j.forsciint.2015.01.030","volume":"249","author":"S Torimitsu","year":"2015","unstructured":"Torimitsu S, Nishida Y, Takano T, Koizumi Y, Hayakawa M, Yajima D, et al. Statistical analysis of biomechanical properties of the adult sagittal suture using a bending method in a Japanese forensic sample. Forensic Sci Int. 2015;249:101\u20136.","journal-title":"Forensic Sci Int"},{"key":"387_CR10","volume-title":"Knight's Forensic Pathology","author":"B Knight","year":"2004","unstructured":"Knight B, Saukko P. Knight\u2019s Forensic Pathology. 3rd ed. London: Arnold; 2004.","edition":"3"},{"key":"387_CR11","doi-asserted-by":"publisher","first-page":"611","DOI":"10.1016\/j.diii.2020.02.010","volume":"101","author":"D Gascho","year":"2020","unstructured":"Gascho D, Zoelch N, Tappero C, Kottner S, Bruellmann E, Thali MJ, et al. Fracture MRI: optimized 3D multi-echo in-phase sequence for bone damage assessment in craniocerebral gunshot injuries. Diagnost Intervent Imag. 2020;101:611\u20135.","journal-title":"Diagnost Intervent Imag"},{"key":"387_CR12","doi-asserted-by":"publisher","first-page":"595","DOI":"10.1007\/s12024-020-00300-w","volume":"16","author":"D Gascho","year":"2020","unstructured":"Gascho D, Deininger-Czermak E, Zoelch N, Tappero C, Sommer S, Hinterholzer N, et al. Noninvasive 7 tesla MRI of fatal craniocerebral gunshots \u2013 a glance into the future of radiologic wound ballistics. Forensic Sci Med Pathol. 2020;16:595\u2013604.","journal-title":"Forensic Sci Med Pathol"},{"key":"387_CR13","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1016\/j.forsciint.2013.08.012","volume":"233","author":"O Peschel","year":"2013","unstructured":"Peschel O, Szeimies U, Vollmar C, Kirchhoff S. Postmortem 3-D reconstruction of skull gunshot injuries. Forensic Sci Int. 2013;233:45\u201350.","journal-title":"Forensic Sci Int"},{"key":"387_CR14","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1016\/S0379-0738(03)00225-1","volume":"138","author":"MJ Thali","year":"2003","unstructured":"Thali MJ, Yen K, Vock P, Ozdoba C, Kneubuehl BP, Sonnenschein M, et al. Image-guided virtual autopsy findings of gunshot victims performed with multi-slice computed tomography (MSCT) and magnetic resonance imaging (MRI) and subsequent correlation between radiology and autopsy findings. Forensic Sci Int. 2003;138:8\u201316.","journal-title":"Forensic Sci Int"},{"key":"387_CR15","doi-asserted-by":"publisher","first-page":"570","DOI":"10.1007\/s00401-003-0683-4","volume":"105","author":"M Oehmichen","year":"2003","unstructured":"Oehmichen M, Gehl H-B, Meissner C, Petersen D, H\u00f6che W, Gerling I, et al. Forensic pathological aspects of postmortem imaging of gunshot injury to the head: documentation and biometric data. Acta Neuropathol. 2003;105:570\u201380.","journal-title":"Acta Neuropathol"}],"container-title":["Forensic Science, Medicine and Pathology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12024-021-00387-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12024-021-00387-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12024-021-00387-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,11,30]],"date-time":"2021-11-30T17:14:13Z","timestamp":1638292453000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12024-021-00387-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,6,9]]},"references-count":15,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["387"],"URL":"https:\/\/doi.org\/10.1007\/s12024-021-00387-9","relation":{},"ISSN":["1547-769X","1556-2891"],"issn-type":[{"value":"1547-769X","type":"print"},{"value":"1556-2891","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,6,9]]},"assertion":[{"value":"4 May 2021","order":1,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 June 2021","order":2,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethical approval was waived by the responsible ethics committee of the Canton of Zurich (waiver number: 2015-0686).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"The internal review board permitted the publication.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication\u00a0"}},{"value":"None of the authors has a real or perceived conflict of interest in any of the material that is presented in this manuscript.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflicts of interest"}}]}}