{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T17:50:17Z","timestamp":1792605017869,"version":"4.5.0"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2019,6,19]],"date-time":"2019-06-19T00:00:00Z","timestamp":1560902400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,6,19]],"date-time":"2019-06-19T00:00:00Z","timestamp":1560902400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Neurocrit Care"],"published-print":{"date-parts":[[2020,4]]},"DOI":"10.1007\/s12028-019-00762-z","type":"journal-article","created":{"date-parts":[[2019,6,19]],"date-time":"2019-06-19T15:02:32Z","timestamp":1560956552000},"page":"478-485","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":72,"title":["Ratio of Optic Nerve Sheath Diameter to Eyeball Transverse Diameter by Ultrasound Can Predict Intracranial Hypertension in Traumatic Brain Injury Patients: A Prospective Study"],"prefix":"10.1007","volume":"32","author":[{"given":"Jie","family":"Du","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yanjun","family":"Deng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hua","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shigang","family":"Qiao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mengnan","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qingya","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chen","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,6,19]]},"reference":[{"issue":"2","key":"762_CR1","first-page":"113","volume":"50","author":"B Malekpour","year":"2012","unstructured":"Malekpour B, Mehrafshan A, Saki F, Malekmohammadi Z, Saki N. Effect of posttraumatic serum thyroid hormone levels on severity and mortality of patients with severe traumatic brain injury. Acta Med Iran. 2012;50(2):113\u20136.","journal-title":"Acta Med Iran"},{"key":"762_CR2","doi-asserted-by":"publisher","DOI":"10.1007\/s12028-018-0658-x","author":"DA Godoy","year":"2018","unstructured":"Godoy DA, N\u00fa\u00f1ez-Pati\u00f1o RA, Zorrilla-Vaca A, et al. Intracranial hypertension after spontaneous intracerebral hemorrhage: a systematic review and meta-analysis of prevalence and mortality rate. Neurocrit Care. 2018. \nhttps:\/\/doi.org\/10.1007\/s12028-018-0658-x\n\n.","journal-title":"Neurocrit Care"},{"key":"762_CR3","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1227\/NEU.0000000000001050","volume":"78","author":"Q Yuan","year":"2016","unstructured":"Yuan Q, Wu X, Cheng H, et al. Is intracranial pressure monitoring of patients with diffuse traumatic brain injury valuable? An Observational Multicenter Study. Neurosurgery. 2016;78:361\u20138.","journal-title":"Neurosurgery"},{"key":"762_CR4","first-page":"950393","volume":"2012","author":"PH Raboel","year":"2012","unstructured":"Raboel PH, Bartek J, Andresen M, Bellander BM, Romner B. Intracranial pressure monitoring: invasive versus non-invasive methods-a review. Crit Care Res Pract. 2012;2012:950393.","journal-title":"Crit Care Res Pract"},{"issue":"3","key":"762_CR5","doi-asserted-by":"publisher","first-page":"461","DOI":"10.1111\/ene.13225","volume":"24","author":"M Ertl","year":"2017","unstructured":"Ertl M, Aigner R, Krost M, et al. Measuring changes in the optic nerve sheath diameter in patients with idiopathic normal-pressure hydrocephalus: a useful diagnostic supplement to spinal tap tests. Eur J Neurol. 2017;24(3):461\u20137.","journal-title":"Eur J Neurol"},{"issue":"7","key":"762_CR6","doi-asserted-by":"publisher","first-page":"e1002356","DOI":"10.1371\/journal.pmed.1002356","volume":"14","author":"C Robba","year":"2017","unstructured":"Robba C, Cardim D, Tajsic T, et al. Ultrasound non-invasive measurement of intracranial pressure in neurointensive care: a prospective observational study. PLoS Med. 2017;14(7):e1002356.","journal-title":"PLoS Med"},{"key":"762_CR7","doi-asserted-by":"publisher","first-page":"1621428","DOI":"10.1155\/2017\/1621428","volume":"2017","author":"M Toscano","year":"2017","unstructured":"Toscano M, Spadetta G, Pulitano P, et al. Optic nerve sheath diameter ultrasound evaluation in intensive care unit: possible role and clinical aspects in neurological critical patients\u2019 daily monitoring. Biomed Res Int. 2017;2017:1621428.","journal-title":"Biomed Res Int"},{"key":"762_CR8","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1016\/j.jss.2011.03.009","volume":"170","author":"A Strumwasser","year":"2011","unstructured":"Strumwasser A, Kwan RO, Yeung L, et al. Sonographic optic nerve sheath diameter as an estimate of intracranial pressure in adult trauma. J Surg Res. 2011;170:265\u201371.","journal-title":"J Surg Res"},{"key":"762_CR9","doi-asserted-by":"publisher","first-page":"280","DOI":"10.1007\/s12028-018-0540-x","volume":"29","author":"V Rajajee","year":"2018","unstructured":"Rajajee V, Williamson CA, Fontana RJ, et al. Noninvasive intracranial pressure assessment in acute liver failure. Neurocrit Care. 2018;29:280\u201390.","journal-title":"Neurocrit Care"},{"key":"762_CR10","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1186\/1746-160X-10-32","volume":"10","author":"M Vaiman","year":"2014","unstructured":"Vaiman M, Gottlieb P, Bekerman I. Quantitative relations between the eyeball, the optic nerve, and the optic canal important for intracranial pressure monitoring. Head Face Med. 2014;10:32.","journal-title":"Head Face Med"},{"issue":"12","key":"762_CR11","doi-asserted-by":"publisher","first-page":"2336","DOI":"10.1016\/j.ajem.2016.08.045","volume":"34","author":"I Bekerman","year":"2016","unstructured":"Bekerman I, Sigal T, Kimiagar I, Ben EA, Vaiman M. The quantitative evaluation of intracranial pressure by optic nerve sheath diameter\/eye diameter CT measurement. Am J Emerg Med. 2016;34(12):2336\u201342.","journal-title":"Am J Emerg Med"},{"key":"762_CR12","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1016\/j.jns.2016.07.023","volume":"368","author":"I Bekerman","year":"2016","unstructured":"Bekerman I, Sigal T, Kimiagar I, Vaiman M. Initial evaluation of the intracranial pressure in cases of traumatic brain injury without hemorrhage. J Neurol Sci. 2016;368:285\u20139.","journal-title":"J Neurol Sci"},{"key":"762_CR13","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1016\/j.jocn.2016.06.008","volume":"34","author":"M Vaiman","year":"2016","unstructured":"Vaiman M, Sigal T, Kimiagar I, Bekerman I. Noninvasive assessment of the intracranial pressure in non-traumatic intracranial hemorrhage. J Clin Neurosci. 2016;34:177\u201381.","journal-title":"J Clin Neurosci"},{"issue":"1","key":"762_CR14","doi-asserted-by":"publisher","first-page":"15906","DOI":"10.1038\/s41598-017-16173-z","volume":"7","author":"DH Kim","year":"2017","unstructured":"Kim DH, Jun JS, Kim R. Ultrasonographic measurement of the optic nerve sheath diameter and its association with eyeball transverse diameter in 585 healthy volunteers. Sci Rep. 2017;7(1):15906.","journal-title":"Sci Rep"},{"issue":"3","key":"762_CR15","doi-asserted-by":"publisher","first-page":"345","DOI":"10.3988\/jcn.2018.14.3.345","volume":"14","author":"DH Kim","year":"2018","unstructured":"Kim DH, Jun JS, Kim R. Measurement of the optic nerve sheath diameter with magnetic resonance imaging and its association with eyeball diameter in healthy adults. J Clin Neurol. 2018;14(3):345\u201350.","journal-title":"J Clin Neurol."},{"issue":"23","key":"762_CR16","doi-asserted-by":"publisher","first-page":"2147","DOI":"10.1089\/neu.2015.4293","volume":"33","author":"M Vaiman","year":"2016","unstructured":"Vaiman M, Sigal T, Kimiagar I, Bekerman I. Intracranial pressure assessment in traumatic head injury with hemorrhage via optic nerve sheath diameter. J Neurotrauma. 2016;33(23):2147\u201353.","journal-title":"J Neurotrauma"},{"key":"762_CR17","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1186\/1471-2377-13-187","volume":"13","author":"J B\u00e4uerle","year":"2013","unstructured":"B\u00e4uerle J, Schuchardt F, Schroeder L, Egger K, Weigel M, Harloff A. Reproducibility and accuracy of optic nerve sheath diameter assessment using ultrasound compared to magnetic resonance imaging. BMC Neurol. 2013;13:187.","journal-title":"BMC Neurol"},{"issue":"11","key":"762_CR18","doi-asserted-by":"publisher","first-page":"1595","DOI":"10.1016\/j.ajem.2013.07.028","volume":"31","author":"H Kalantari","year":"2013","unstructured":"Kalantari H, Jaiswal R, Bruck I, et al. Correlation of optic nerve sheath diameter measurements by computed tomography and magnetic resonance imaging. Am J Emerg Med. 2013;31(11):1595\u20137.","journal-title":"Am J Emerg Med"},{"issue":"4","key":"762_CR19","doi-asserted-by":"publisher","first-page":"450","DOI":"10.1016\/j.jemermed.2014.09.060","volume":"48","author":"GW Hassen","year":"2015","unstructured":"Hassen GW, Bruck I, Donahue J, et al. Accuracy of optic nerve sheath diameter measurement by emergency physicians using bedside ultrasound. J Emerg Med. 2015;48(4):450\u20137.","journal-title":"J Emerg Med"},{"issue":"8","key":"762_CR20","doi-asserted-by":"publisher","first-page":"466","DOI":"10.4103\/0972-5229.162465","volume":"19","author":"CG Shirodkar","year":"2015","unstructured":"Shirodkar CG, Munta K, Rao SM, Mahesh MU. Correlation of measurement of optic nerve sheath diameter using ultrasound with magnetic resonance imaging. Indian J Crit Care Med. 2015;19(8):466\u201370.","journal-title":"Indian J Crit Care Med"},{"issue":"7","key":"762_CR21","doi-asserted-by":"publisher","first-page":"1118","DOI":"10.1177\/0963689717714102","volume":"26","author":"M Galgano","year":"2017","unstructured":"Galgano M, Toshkezi G, Qiu X, Russell T, Chin L, Zhao LR. Traumatic brain injury: current treatment strategies and future endeavors. Cell Transplant. 2017;26(7):1118\u201330.","journal-title":"Cell Transplant"},{"issue":"1","key":"762_CR22","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1016\/j.ajem.2016.09.044","volume":"35","author":"M Raffiz","year":"2017","unstructured":"Raffiz M, Abdullah JM. Optic nerve sheath diameter measurement: a means of detecting raised ICP in adult traumatic and non-traumatic neurosurgical patients. Am J Emerg Med. 2017;35(1):150\u20133.","journal-title":"Am J Emerg Med"},{"key":"762_CR23","doi-asserted-by":"publisher","first-page":"837","DOI":"10.2307\/2531595","volume":"44","author":"ER DeLong","year":"1988","unstructured":"DeLong ER, DeLong DM. Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics. 1988;44:837\u201345.","journal-title":"Biometrics"},{"issue":"8","key":"762_CR24","doi-asserted-by":"publisher","first-page":"791","DOI":"10.1197\/aemj.9.8.791","volume":"9","author":"M Blaivas","year":"2002","unstructured":"Blaivas M, Theodoro D, Sierzenski PR. A study of bedside ocular ultrasonography in the emergency department. Acad Emerg Med. 2002;9(8):791\u20139.","journal-title":"Acad Emerg Med"}],"container-title":["Neurocritical Care"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12028-019-00762-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s12028-019-00762-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12028-019-00762-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,6,17]],"date-time":"2020-06-17T23:35:17Z","timestamp":1592436917000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s12028-019-00762-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,6,19]]},"references-count":24,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020,4]]}},"alternative-id":["762"],"URL":"https:\/\/doi.org\/10.1007\/s12028-019-00762-z","relation":{},"ISSN":["1541-6933","1556-0961"],"issn-type":[{"value":"1541-6933","type":"print"},{"value":"1556-0961","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,6,19]]},"assertion":[{"value":"19 June 2019","order":1,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declared that they have no conflicts of interest to this work.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflicts of interest"}},{"value":"This study was conducted according to our institution\u2019s guidelines for ethical research. Institutional review board approval was obtained for this study (IRB2019007).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical Approval\/Informed Consent"}}]}}