{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,30]],"date-time":"2025-03-30T23:40:33Z","timestamp":1743378033769,"version":"3.40.3"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2024,10,2]],"date-time":"2024-10-02T00:00:00Z","timestamp":1727827200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,10,2]],"date-time":"2024-10-02T00:00:00Z","timestamp":1727827200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Neurocrit Care"],"published-print":{"date-parts":[[2025,4]]},"DOI":"10.1007\/s12028-024-02136-6","type":"journal-article","created":{"date-parts":[[2024,10,2]],"date-time":"2024-10-02T20:38:34Z","timestamp":1727901514000},"page":"374-386","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Comparative Efficacy and Safety of External Ventricular Drains and Intraparenchymal Pressure Monitors for Intracranial Pressure Monitoring in Traumatic Brain Injury: A Systematic Review and Meta-analysis"],"prefix":"10.1007","volume":"42","author":[{"given":"Luis A.","family":"Marin-Casta\u00f1eda","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rolando A.","family":"G\u00f3mez-Villarroel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Geronimo","family":"Pacheco Aispuro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nadia","family":"Palomera-Garfias","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Niels","family":"Pacheco-Barrios","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Valery M.","family":"Sandoval-Orellana","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0804-2825","authenticated-orcid":false,"given":"Pavel S.","family":"Pichardo-Rojas","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,10,2]]},"reference":[{"issue":"10","key":"2136_CR1","doi-asserted-by":"crossref","DOI":"10.1136\/bmjopen-2023-075049","volume":"13","author":"B Guan","year":"2023","unstructured":"Guan B, Anderson DB, Chen L, Feng S, Zhou H. Global, regional and national burden of traumatic brain injury and spinal cord injury, 1990\u20132019: a systematic analysis for the Global Burden of Disease Study 2019. BMJ Open. 2023;13(10): e075049.","journal-title":"BMJ Open"},{"issue":"4","key":"2136_CR2","doi-asserted-by":"crossref","first-page":"1080","DOI":"10.3171\/2017.10.JNS17352","volume":"130","author":"MC Dewan","year":"2018","unstructured":"Dewan MC, Rattani A, Gupta S, Baticulon RE, Hung YC, Punchak M, et al. Estimating the global incidence of traumatic brain injury. J Neurosurg. 2018;130(4):1080\u201397.","journal-title":"J Neurosurg"},{"issue":"6","key":"2136_CR3","doi-asserted-by":"crossref","first-page":"650","DOI":"10.1097\/MCC.0000000000001094","volume":"29","author":"I Hossain","year":"2023","unstructured":"Hossain I, Rostami E, Marklund N. The management of severe traumatic brain injury in the initial postinjury hours - current evidence and controversies. Curr Opin Crit Care. 2023;29(6):650\u20138.","journal-title":"Curr Opin Crit Care"},{"issue":"3","key":"2136_CR4","first-page":"37","volume":"7","author":"RA Stocker","year":"2019","unstructured":"Stocker RA. Intensive care in traumatic brain injury including multi-modal monitoring and neuroprotection. Med Sci (Basel). 2019;7(3):37.","journal-title":"Med Sci (Basel)"},{"issue":"6","key":"2136_CR5","doi-asserted-by":"crossref","first-page":"950","DOI":"10.1016\/j.jamcollsurg.2012.03.004","volume":"214","author":"G Kasotakis","year":"2012","unstructured":"Kasotakis G, Michailidou M, Bramos A, Chang Y, Velmahos G, Alam H, et al. Intraparenchymal vs extracranial ventricular drain intracranial pressure monitors in traumatic brain injury: Less is more? J Am Coll Surg. 2012;214(6):950\u20137.","journal-title":"J Am Coll Surg"},{"issue":"6","key":"2136_CR6","doi-asserted-by":"crossref","first-page":"1996","DOI":"10.3390\/jcm9061996","volume":"9","author":"CY Chau","year":"2020","unstructured":"Chau CY, Mediratta S, McKie MA, Gregson B, Tulu S, Ercole A, et al. Optimal timing of external ventricular drainage after severe traumatic brain injury: a systematic review. J Clin Med. 2020;9(6):1996.","journal-title":"J Clin Med"},{"issue":"1","key":"2136_CR7","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1007\/s12028-019-00712-9","volume":"31","author":"JW Bales","year":"2019","unstructured":"Bales JW, Bonow RH, Buckley RT, Barber J, Temkin N, Chesnut RM. Primary external ventricular drainage catheter versus intraparenchymal ICP monitoring: outcome analysis. Neurocrit Care. 2019;31(1):11\u201321.","journal-title":"Neurocrit Care"},{"key":"2136_CR8","doi-asserted-by":"crossref","first-page":"e221","DOI":"10.1016\/j.wneu.2023.07.037","volume":"178","author":"RG Dolmans","year":"2023","unstructured":"Dolmans RG, Harary M, Nawabi N, Taros T, Kilgallon JL, Mekary RA, et al. External ventricular drains versus intraparenchymal pressure monitors in the management of moderate to severe traumatic brain injury: experience at two academic centers over a decade. World Neurosurg. 2023;178:e221\u20139.","journal-title":"World Neurosurg"},{"issue":"1","key":"2136_CR9","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1186\/s13643-021-01626-4","volume":"10","author":"MJ Page","year":"2021","unstructured":"Page MJ, McKenzie JE, Bossuyt PM, Boutron I, Hoffmann TC, Mulrow CD, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. Syst Rev. 2021;10(1):89.","journal-title":"Syst Rev"},{"key":"2136_CR10","doi-asserted-by":"publisher","DOI":"10.1002\/14651858.ED000142","author":"M Cumpston","year":"2019","unstructured":"Cumpston M, Li T, Page MJ, Chandler J, Welch VA, Higgins JPT, Thomas J. Updated guidance for trusted systematic reviews: a new edition of the Cochrane Handbook for Systematic Reviews of Interventions. Cochrane Database Syst Rev. 2019. https:\/\/doi.org\/10.1002\/14651858.ED000142.","journal-title":"Cochrane Database Syst Rev"},{"key":"2136_CR11","volume":"355","author":"JA Sterne","year":"2016","unstructured":"Sterne JA, Hern\u00e1n MA, Reeves BC, Savovi\u0107 J, Berkman ND, Viswanathan M, et al. ROBINS-I: a tool for assessing risk of bias in non-randomised studies of interventions. BMJ. 2016;355: i4919.","journal-title":"BMJ"},{"key":"2136_CR12","unstructured":"Higgins JP, Thomas J, Chandler J, Cumpston M, Li T, Page MJ, et al. Cochrane Handbook for Systematic Reviews of Interventions version 6.3. Cochrane. Published February 2022. Accessed July 24, 2023.\u00a0http:\/\/www.training.cochrane.org\/handbook"},{"key":"2136_CR13","volume":"366","author":"JA Sterne","year":"2019","unstructured":"Sterne JA, Savovi\u0107 J, Page MJ, Elbers RG, Blencowe NS, Boutron I, et al. RoB 2: a revised tool for assessing risk of bias in randomised trials. BMJ. 2019;366: l4898.","journal-title":"BMJ"},{"issue":"3","key":"2136_CR14","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/0197-2456(86)90046-2","volume":"7","author":"R DerSimonian","year":"1986","unstructured":"DerSimonian R, Laird N. Meta-analysis in clinical trials. Control Clin Trials. 1986;7(3):177\u201388.","journal-title":"Control Clin Trials"},{"issue":"7414","key":"2136_CR15","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1136\/bmj.327.7414.557","volume":"327","author":"JP Higgins","year":"2003","unstructured":"Higgins JP, Thompson SG, Deeks JJ, Altman DG. Measuring inconsistency in meta-analyses. BMJ. 2003;327(7414):557\u201360.","journal-title":"BMJ"},{"key":"2136_CR16","volume":"189","author":"Z Li","year":"2020","unstructured":"Li Z, Xu F, Li Y, Wang R, Zhang Z, Qu Y. Assessment of intracranial pressure monitoring in patients with moderate traumatic brain injury: a retrospective cohort study. Clin Neurol Neurosurg. 2020;189: 105538.","journal-title":"Clin Neurol Neurosurg"},{"issue":"5","key":"2136_CR17","doi-asserted-by":"crossref","first-page":"794","DOI":"10.1016\/j.wneu.2014.12.040","volume":"83","author":"H Liu","year":"2015","unstructured":"Liu H, Wang W, Cheng F, Yuan Q, Yang J, Hu J, et al. External ventricular drains versus intraparenchymal intracranial pressure monitors in traumatic brain injury: a prospective observational study. World Neurosurg. 2015;83(5):794\u2013800.","journal-title":"World Neurosurg"},{"issue":"3","key":"2136_CR18","doi-asserted-by":"crossref","first-page":"828","DOI":"10.3171\/2016.11.JNS162198","volume":"128","author":"A Aiolfi","year":"2018","unstructured":"Aiolfi A, Khor D, Cho J, Benjamin E, Inaba K, Demetriades D. Intracranial pressure monitoring in severe blunt head trauma: Does the type of monitoring device matter? J Neurosurg. 2018;128(3):828\u201333.","journal-title":"J Neurosurg"},{"key":"2136_CR19","doi-asserted-by":"crossref","first-page":"e445","DOI":"10.1016\/j.wneu.2023.07.096","volume":"178","author":"N Mouchtouris","year":"2023","unstructured":"Mouchtouris N, Luck T, Yudkoff C, Locke K, Momin A, Khanna O, et al. Ventriculostomy associated with reduced mortality in severe traumatic brain injury compared to parenchymal ICP monitoring: a propensity score-adjusted analysis. World Neurosurg. 2023;178:e445\u201352.","journal-title":"World Neurosurg"},{"issue":"7","key":"2136_CR20","doi-asserted-by":"crossref","first-page":"1693","DOI":"10.1007\/s00701-022-05257-z","volume":"164","author":"V Volovici","year":"2022","unstructured":"Volovici V, Pisic\u0103 D, Gravesteijn BY, Dirven CM, Steyerberg EW, Ercole A, et al. CENTER-TBI investigators, participants for the ICU stratum. Comparative effectiveness of intracranial hypertension management guided by ventricular versus intraparenchymal pressure monitoring: a CENTER-TBI study. Acta Neurochir (Wien). 2022;164(7):1693\u2013705.","journal-title":"Acta Neurochir (Wien)"},{"key":"2136_CR21","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/j.wneu.2022.11.134","volume":"171","author":"N Mahto","year":"2023","unstructured":"Mahto N, Owodunni OP, Okakpu U, Kazim SF, Varela S, Varela Y, et al. Postprocedural complications of external ventricular drains: a meta-analysis evaluating the absolute risk of hemorrhages, infections, and revisions. World Neurosurg. 2023;171:41\u201364.","journal-title":"World Neurosurg"},{"issue":"1","key":"2136_CR22","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1007\/s12028-015-0224-8","volume":"24","author":"HI Fried","year":"2016","unstructured":"Fried HI, Nathan BR, Rowe AS, Zabramski JM, Andaluz N, Bhimraj A, et al. The insertion and management of external ventricular drains: an evidence-based consensus statement: a statement for healthcare professionals from the Neurocritical Care Society. Neurocrit Care. 2016;24(1):61\u201381.","journal-title":"Neurocrit Care"},{"issue":"12","key":"2136_CR23","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1007\/s11910-019-1009-9","volume":"19","author":"DY Chung","year":"2019","unstructured":"Chung DY, Olson DM, John S, Mohamed W, Kumar MA, Thompson BB, et al. Evidence-based management of external ventricular drains. Curr Neurol Neurosci Rep. 2019;19(12):94.","journal-title":"Curr Neurol Neurosci Rep"},{"issue":"7 Suppl 6","key":"2136_CR24","doi-asserted-by":"crossref","first-page":"S271","DOI":"10.4103\/2152-7806.157620","volume":"6","author":"R Muralidharan","year":"2015","unstructured":"Muralidharan R. External ventricular drains: management and complications. Surg Neurol Int. 2015;6(7 Suppl 6):S271\u20134.","journal-title":"Surg Neurol Int"},{"issue":"3","key":"2136_CR25","doi-asserted-by":"crossref","first-page":"574","DOI":"10.3171\/2014.10.JNS1460","volume":"122","author":"Q Yuan","year":"2015","unstructured":"Yuan Q, Wu X, Sun Y, Yu J, Li Z, Du Z, et al. Impact of intracranial pressure monitoring on mortality in patients with traumatic brain injury: a systematic review and meta-analysis. J Neurosurg. 2015;122(3):574\u201387.","journal-title":"J Neurosurg"},{"key":"2136_CR26","first-page":"1956908","volume":"2022","author":"N Han","year":"2022","unstructured":"Han N, Yang F, Zhang X. The significance of intracranial pressure monitoring for reducing mortality in patients with traumatic brain injury: a systematic review and meta-analysis. Comput Math Methods Med. 2022;2022:1956908.","journal-title":"Comput Math Methods Med"},{"issue":"12","key":"2136_CR27","volume":"11","author":"L Shen","year":"2016","unstructured":"Shen L, Wang Z, Su Z, Qiu S, Xu J, Zhou Y, et al. Effects of intracranial pressure monitoring on mortality in patients with severe traumatic brain injury: a meta-analysis. PLoS ONE. 2016;11(12): e0168901.","journal-title":"PLoS ONE"},{"issue":"7","key":"2136_CR28","volume":"95","author":"J Han","year":"2016","unstructured":"Han J, Yang S, Zhang C, Zhao M, Li A. Impact of intracranial pressure monitoring on prognosis of patients with severe traumatic brain injury: a PRISMA systematic review and meta-analysis. Medicine (Baltimore). 2016;95(7): e2827.","journal-title":"Medicine (Baltimore)"}],"container-title":["Neurocritical Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12028-024-02136-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12028-024-02136-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12028-024-02136-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,30]],"date-time":"2025-03-30T23:10:48Z","timestamp":1743376248000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12028-024-02136-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10,2]]},"references-count":28,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2025,4]]}},"alternative-id":["2136"],"URL":"https:\/\/doi.org\/10.1007\/s12028-024-02136-6","relation":{},"ISSN":["1541-6933","1556-0961"],"issn-type":[{"type":"print","value":"1541-6933"},{"type":"electronic","value":"1556-0961"}],"subject":[],"published":{"date-parts":[[2024,10,2]]},"assertion":[{"value":"4 July 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 September 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 October 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare that they have no conflicts of interest.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interests"}}]}}