{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,9]],"date-time":"2026-06-09T17:00:52Z","timestamp":1781024452004,"version":"3.54.1"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2026,3,25]],"date-time":"2026-03-25T00:00:00Z","timestamp":1774396800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,3,25]],"date-time":"2026-03-25T00:00:00Z","timestamp":1774396800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Neurocrit Care"],"published-print":{"date-parts":[[2026,6]]},"DOI":"10.1007\/s12028-026-02493-4","type":"journal-article","created":{"date-parts":[[2026,3,25]],"date-time":"2026-03-25T17:34:05Z","timestamp":1774460045000},"page":"1050-1062","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Operator and Modality-Dependent Limitations of Optic Nerve Sheath Diameter Sonography for Raised ICP in TBI: A Meta-Regression of Diagnostic Accuracy"],"prefix":"10.1007","volume":"44","author":[{"given":"Johnson","family":"Kannady","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1107-055X","authenticated-orcid":false,"given":"Andre M. P.","family":"Siahaan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muhammad R. A.","family":"Harahap","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elke","family":"Aprilia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alvin","family":"Ivander","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,3,25]]},"reference":[{"issue":"4","key":"2493_CR1","doi-asserted-by":"publisher","first-page":"491","DOI":"10.3171\/jns.1977.47.4.0491","volume":"47","author":"DP Becker","year":"1977","unstructured":"Becker DP, Miller JD, Ward JD, Greenberg RP, Young HF, Sakalas R. The outcome from severe head injury with early diagnosis and intensive management. J Neurosurg. 1977;47(4):491\u2013502.","journal-title":"J Neurosurg"},{"issue":"22","key":"2493_CR2","doi-asserted-by":"publisher","first-page":"2121","DOI":"10.1056\/NEJMra1208708","volume":"370","author":"N Stocchetti","year":"2014","unstructured":"Stocchetti N, Maas AIR. Traumatic intracranial hypertension. N Engl J Med. 2014;370(22):2121\u201330.","journal-title":"N Engl J Med"},{"issue":"26","key":"2493_CR3","doi-asserted-by":"publisher","first-page":"2471","DOI":"10.1056\/NEJMoa1207363","volume":"367","author":"RM Chesnut","year":"2012","unstructured":"Chesnut RM, Temkin N, Carney N, et\u00a0al. A trial of intracranial-pressure monitoring in traumatic brain injury. N Engl J Med. 2012;367(26):2471\u201381.","journal-title":"N Engl J Med"},{"issue":"1","key":"2493_CR4","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1227\/NEU.0000000000001432","volume":"80","author":"N Carney","year":"2017","unstructured":"Carney N, Totten AM, O\u2019Reilly C, Ullman JS, Hawryluk GW, Bell MJ, et\u00a0al. Guidelines for the management of severe traumatic brain injury, fourth edition. Neurosurgery. 2017;80(1):6\u201315.","journal-title":"Neurosurgery"},{"issue":"5","key":"2493_CR5","doi-asserted-by":"publisher","first-page":"814","DOI":"10.1111\/jon.12906","volume":"31","author":"RRF Stevens","year":"2021","unstructured":"Stevens RRF, Gommer ED, Aries MJH, Ertl M, Mess WH, Huberts W, et\u00a0al. Optic nerve sheath diameter assessment by neurosonology: a review of methodologic discrepancies. J Neuroimaging. 2021;31(5):814\u201325.","journal-title":"J Neuroimaging"},{"issue":"5","key":"2493_CR6","first-page":"467","volume":"66","author":"D Agrawal","year":"2020","unstructured":"Agrawal D, Ranjan A, Singhi SC. Sonographic optic nerve sheath diameter in children with raised intracranial pressure. J Trop Pediatr. 2020;66(5):467\u201374.","journal-title":"J Trop Pediatr"},{"issue":"11","key":"2493_CR7","doi-asserted-by":"publisher","first-page":"2062","DOI":"10.1007\/s00134-008-1149-x","volume":"34","author":"T Geeraerts","year":"2008","unstructured":"Geeraerts T, Merceron S, Benhamou D, Vigu\u00e9 B, Duranteau J. Non-invasive assessment of intracranial pressure using ocular sonography in neurocritical care patients. Intensive Care Med. 2008;34(11):2062\u20137.","journal-title":"Intensive Care Med"},{"issue":"2","key":"2493_CR8","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1111\/j.1553-2712.2007.00031.x","volume":"15","author":"HH Kimberly","year":"2008","unstructured":"Kimberly HH, Shah S, Marill K, Noble V. Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure. Acad Emerg Med. 2008;15(2):201\u20134.","journal-title":"Acad Emerg Med"},{"issue":"8","key":"2493_CR9","doi-asserted-by":"publisher","first-page":"1284","DOI":"10.1007\/s00134-018-5305-7","volume":"44","author":"C Robba","year":"2018","unstructured":"Robba C, Santori G, Czosnyka M, et\u00a0al. Optic nerve sheath diameter measured sonographically as non-invasive estimator of intracranial pressure: a systematic review and meta-analysis. Intensive Care Med. 2018;44(8):1284\u201394.","journal-title":"Intensive Care Med"},{"issue":"6","key":"2493_CR10","first-page":"745","volume":"65","author":"R Ohle","year":"2015","unstructured":"Ohle R, McIsaac SM, Woo MY, Perry JJ. Sonography of the optic nerve sheath diameter for detection of raised intracranial pressure compared to computed tomography. Ann Emerg Med. 2015;65(6):745\u201353.","journal-title":"Ann Emerg Med"},{"key":"2493_CR11","volume":"343","author":"J Dubourg","year":"2011","unstructured":"Dubourg J, Javouhey E, Geeraerts T, Messerer M, Kassai B. Diagnostic accuracy of ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: systematic review and meta-analysis. BMJ. 2011;343:d4277.","journal-title":"BMJ"},{"issue":"5","key":"2493_CR12","doi-asserted-by":"crossref","first-page":"1211","DOI":"10.1007\/s10072-019-04146-1","volume":"41","author":"P Lochner","year":"2020","unstructured":"Lochner P, Czosnyka M, Naldi A, et\u00a0al. B-scan versus A-scan ultrasonography for measuring optic nerve sheath diameter: technical and diagnostic considerations. Neurol Sci. 2020;41(5):1211\u20139.","journal-title":"Neurol Sci"},{"issue":"6","key":"2493_CR13","first-page":"1131","volume":"46","author":"D Cardim","year":"2020","unstructured":"Cardim D, Robba C, Donnelly J, et\u00a0al. Variability in measurement of optic nerve sheath diameter by ultrasound: a systematic review. Intensive Care Med. 2020;46(6):1131\u20133.","journal-title":"Intensive Care Med"},{"issue":"12","key":"2493_CR14","first-page":"3468","volume":"47","author":"S Ozturk","year":"2021","unstructured":"Ozturk S, Ozturk E, Buyukkaya R, et\u00a0al. Interobserver and intraobserver reliability of sonographic optic nerve sheath diameter measurement. Ultrasound Med Biol. 2021;47(12):3468\u201376.","journal-title":"Ultrasound Med Biol"},{"issue":"3","key":"2493_CR15","first-page":"707","volume":"37","author":"F Cour-Andlauer","year":"2022","unstructured":"Cour-Andlauer F, Garnier A, Moulis G, et\u00a0al. Reliability of optic nerve sheath diameter ultrasound in pediatric critical care: multicenter observational study. Neurocrit Care. 2022;37(3):707\u201316.","journal-title":"Neurocrit Care"},{"issue":"7","key":"2493_CR16","first-page":"1295","volume":"39","author":"J Du","year":"2020","unstructured":"Du J, Deng Y, Li H, Qiao S, Ge W. Ratio of optic nerve sheath diameter to eyeball transverse diameter by ultrasound predicts intracranial hypertension in traumatic brain injury: prospective study. J Ultrasound Med. 2020;39(7):1295\u2013303.","journal-title":"J Ultrasound Med"},{"key":"2493_CR17","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1186\/s41983-021-00298-0","volume":"57","author":"AS Altayar","year":"2021","unstructured":"Altayar AS, Abouelela AZ, Abdelshafey EE, et\u00a0al. Optic nerve sheath diameter by ultrasound as a screening tool for high intracranial pressure in traumatic brain injury. Egypt J Neurol Psychiatry Neurosurg. 2021;57:44.","journal-title":"Egypt J Neurol Psychiatry Neurosurg"},{"issue":"8","key":"2493_CR18","first-page":"2591","volume":"37","author":"SR Kerscher","year":"2021","unstructured":"Kerscher SR, Dhanda S, Agrawal D, et\u00a0al. Sonographic optic nerve sheath diameter in pediatric patients with raised intracranial pressure: systematic review. Childs Nerv Syst. 2021;37(8):2591\u2013602.","journal-title":"Childs Nerv Syst"},{"key":"2493_CR19","first-page":"1145782","volume":"14","author":"LM Chen","year":"2023","unstructured":"Chen LM, Wang LJ, Hu Y, et\u00a0al. Diagnostic performance of optic nerve sheath diameter ultrasound for intracranial hypertension: updated meta-analysis. Front Neurol. 2023;14:1145782.","journal-title":"Front Neurol"},{"issue":"1","key":"2493_CR20","first-page":"123","volume":"38","author":"H Berhanu","year":"2023","unstructured":"Berhanu H, Alkhatip AA, Wang J, et\u00a0al. Diagnostic accuracy of optic nerve sheath diameter ultrasonography for raised intracranial pressure: systematic review and meta-analysis. Neurocrit Care. 2023;38(1):123\u201334.","journal-title":"Neurocrit Care"},{"issue":"5","key":"2493_CR21","first-page":"1613","volume":"134","author":"C Robba","year":"2021","unstructured":"Robba C, Cardim D, Sekhon MS, et\u00a0al. Optic nerve sheath diameter ultrasonography in neurocritical care: evidence and practice. J Neurosurg. 2021;134(5):1613\u201322.","journal-title":"J Neurosurg"},{"issue":"3","key":"2493_CR22","first-page":"R94","volume":"11","author":"T Geeraerts","year":"2007","unstructured":"Geeraerts T, Launey Y, Martin L, et\u00a0al. Ultrasonography of the optic nerve sheath may be useful for detecting raised intracranial pressure after brain injury. Crit Care. 2007;11(3):R94.","journal-title":"Crit Care"},{"issue":"1","key":"2493_CR23","first-page":"158","volume":"31","author":"C Robba","year":"2019","unstructured":"Robba C, Donnelly J, Cardim D, et\u00a0al. Optic nerve sheath diameter ultrasonography for raised intracranial pressure: operator-related variability and learning curve. Neurocrit Care. 2019;31(1):158\u201366.","journal-title":"Neurocrit Care"},{"issue":"5","key":"2493_CR24","first-page":"1847","volume":"42","author":"C Robba","year":"2021","unstructured":"Robba C, Bragazzi NL, Bertuccio A, et\u00a0al. ONSD sonography in critical care: a practice-based evidence approach. Neurol Sci. 2021;42(5):1847\u201355.","journal-title":"Neurol Sci"}],"container-title":["Neurocritical Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12028-026-02493-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12028-026-02493-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12028-026-02493-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,9]],"date-time":"2026-06-09T16:28:31Z","timestamp":1781022511000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12028-026-02493-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,25]]},"references-count":24,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,6]]}},"alternative-id":["2493"],"URL":"https:\/\/doi.org\/10.1007\/s12028-026-02493-4","relation":{},"ISSN":["1541-6933","1556-0961"],"issn-type":[{"value":"1541-6933","type":"print"},{"value":"1556-0961","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,25]]},"assertion":[{"value":"30 September 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 March 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 March 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All authors declare no conflicts of interest related to this study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This study is a systematic review\/meta-analysis of published studies; institutional review board approval was not required.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical Approval"}}]}}