{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T18:07:55Z","timestamp":1791828475231,"version":"4.3.4"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2020,5,17]],"date-time":"2020-05-17T00:00:00Z","timestamp":1589673600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,5,17]],"date-time":"2020-05-17T00:00:00Z","timestamp":1589673600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Clin Transl Oncol"],"published-print":{"date-parts":[[2020,12]]},"DOI":"10.1007\/s12094-020-02374-y","type":"journal-article","created":{"date-parts":[[2020,5,17]],"date-time":"2020-05-17T09:02:31Z","timestamp":1589706151000},"page":"2286-2292","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Radiotherapy is safe in patients with implantable cardiac devices. Analysis of a systematic interrogation follow-up"],"prefix":"10.1007","volume":"22","author":[{"given":"V.","family":"L\u00f3pez-Honrubia","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"V. M.","family":"Hidalgo-Olivares","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Dob\u00f3n-Roux","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M. M.","family":"Mart\u00ed-Laosa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Castro-Larefors","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Fernandez-Lopez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"I.","family":"Andres","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"O.","family":"Roche","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Rovirosa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Arenas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"F.","family":"Martinez-Terol","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T.","family":"L\u00f3pez Fern\u00e1ndez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0111-9540","authenticated-orcid":false,"given":"S.","family":"Sabater","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,5,17]]},"reference":[{"issue":"841","key":"2374_CR1","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1259\/bjr.71.841.9534692","volume":"71","author":"A Last","year":"1998","unstructured":"Last A. Radiotherapy in patients with cardiac pacemakers. Br J Radiol. 1998;71(841):4\u201310. https:\/\/doi.org\/10.1259\/bjr.71.841.9534692.","journal-title":"Br J Radiol"},{"issue":"1","key":"2374_CR2","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1118\/1.597259","volume":"21","author":"JR Marbach","year":"1994","unstructured":"Marbach JR, Sontag MR, Van Dyk J, Wolbarst AB. Management of radiation oncology patients with implanted cardiac pacemakers: report of AAPM task group no. 34. Med Phys. 1994;21(1):85\u201390.","journal-title":"Med Phys."},{"issue":"12","key":"2374_CR3","doi-asserted-by":"publisher","first-page":"e757","DOI":"10.1002\/mp.13838","volume":"46","author":"M Miften","year":"2019","unstructured":"Miften M, Mihailidis D, Kry SF, Reft C, Esquivel C, Farr J, et al. Management of radiotherapy patients with implanted cardiac pacemakers and defibrillators: a report of the AAPM TG-203(dagger). Med Phys. 2019;46(12):e757\u2013e788788. https:\/\/doi.org\/10.1002\/mp.13838.","journal-title":"Med Phys"},{"issue":"6","key":"2374_CR4","doi-asserted-by":"publisher","first-page":"474","DOI":"10.1016\/j.ctrv.2005.05.002","volume":"31","author":"S Sundar","year":"2005","unstructured":"Sundar S, Symonds RP, Deehan C. Radiotherapy to patients with artificial cardiac pacemakers. Cancer Treat Rev. 2005;31(6):474\u201386. https:\/\/doi.org\/10.1016\/j.ctrv.2005.05.002.","journal-title":"Cancer Treat Rev"},{"issue":"5","key":"2374_CR5","doi-asserted-by":"publisher","first-page":"666","DOI":"10.1097\/01.HP.0000326342.47348.06","volume":"95","author":"JA Purdy","year":"2008","unstructured":"Purdy JA. Dose to normal tissues outside the radiation therapy patient's treated volume: a review of different radiation therapy techniques. Health Phys. 2008;95(5):666\u201376. https:\/\/doi.org\/10.1097\/01.HP.0000326342.47348.06.","journal-title":"Health Phys"},{"issue":"2","key":"2374_CR6","first-page":"111","volume":"13","author":"GM Mart\u00edn","year":"2013","unstructured":"Mart\u00edn GM. Tratamiento de pacientes en radioterapia con marcapasos o desfibriladores autom\u00e1ticos implantables. Rev F\u00edsica M\u00e9d. 2013;13(2):111\u201324.","journal-title":"Rev F\u00edsica M\u00e9d"},{"key":"2374_CR7","doi-asserted-by":"publisher","first-page":"198","DOI":"10.1186\/1748-717X-7-198","volume":"7","author":"CW Hurkmans","year":"2012","unstructured":"Hurkmans CW, Knegjens JL, Oei BS, Maas AJ, Uiterwaal GJ, van der Borden AJ, et al. Management of radiation oncology patients with a pacemaker or ICD: a new comprehensive practical guideline in The Netherlands Dutch society of radiotherapy and oncology (NVRO). Radiation oncology. 2012;7:198. https:\/\/doi.org\/10.1186\/1748-717X-7-198.","journal-title":"Radiation oncology."},{"issue":"5","key":"2374_CR8","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1007\/s00066-015-0817-3","volume":"191","author":"B Gauter-Fleckenstein","year":"2015","unstructured":"Gauter-Fleckenstein B, Israel CW, Dorenkamp M, Dunst J, Roser M, Schimpf R, et al. DEGRO\/DGK guideline for radiotherapy in patients with cardiac implantable electronic devices. Strahlentherapie Onkol. 2015;191(5):393\u2013404. https:\/\/doi.org\/10.1007\/s00066-015-0817-3.","journal-title":"Strahlentherapie Onkol"},{"issue":"12","key":"2374_CR9","doi-asserted-by":"publisher","first-page":"1577","DOI":"10.1007\/s12094-018-1893-5","volume":"20","author":"S Sabater","year":"2018","unstructured":"Sabater S, Montero A, Lopez Fernandez T, Gonzalez Ferrer JJ, Arenas M. Management of patients with implanted cardiac devices during radiotherapy: results of a Spanish survey in radiation oncology departments. Clin Trans Oncol. 2018;20(12):1577\u201381. https:\/\/doi.org\/10.1007\/s12094-018-1893-5.","journal-title":"Clin Trans Oncol"},{"issue":"10","key":"2374_CR10","doi-asserted-by":"publisher","first-page":"2148","DOI":"10.1016\/j.hrthm.2015.06.003","volume":"12","author":"M Brambatti","year":"2015","unstructured":"Brambatti M, Mathew R, Strang B, Dean J, Goyal A, Hayward JE, et al. Management of patients with implantable cardioverter-defibrillators and pacemakers who require radiation therapy. Heart Rhythm. 2015;12(10):2148\u201354. https:\/\/doi.org\/10.1016\/j.hrthm.2015.06.003.","journal-title":"Heart Rhythm"},{"issue":"2","key":"2374_CR11","doi-asserted-by":"publisher","first-page":"284","DOI":"10.1016\/j.amjcard.2016.09.036","volume":"119","author":"R Bagur","year":"2017","unstructured":"Bagur R, Chamula M, Brouillard E, Lavoie C, Nombela-Franco L, Julien AS, et al. Radiotherapy-induced cardiac implantable electronic device dysfunction in patients with cancer. Am J Cardiol. 2017;119(2):284\u20139. https:\/\/doi.org\/10.1016\/j.amjcard.2016.09.036.","journal-title":"Am J Cardiol"},{"key":"2374_CR12","doi-asserted-by":"publisher","unstructured":"Soejima T, Yoden E, Y NI, Ono S, Yoshida A, Fukuda H, et al. Radiation therapy in patients with implanted cardiac pacemakers and implantable cardioverter defibrillators: a prospective survey in Japan. J Radiat Res. 2011;52(4):516\u201321. https:\/\/doi.org\/10.1269\/jrr.10143.","DOI":"10.1269\/jrr.10143"},{"issue":"12","key":"2374_CR13","doi-asserted-by":"publisher","first-page":"1964","DOI":"10.1016\/j.hrthm.2012.08.018","volume":"9","author":"A Makkar","year":"2012","unstructured":"Makkar A, Prisciandaro J, Agarwal S, Lusk M, Horwood L, Moran J, et al. Effect of radiation therapy on permanent pacemaker and implantable cardioverter-defibrillator function. Heart Rhythm. 2012;9(12):1964\u20138. https:\/\/doi.org\/10.1016\/j.hrthm.2012.08.018.","journal-title":"Heart Rhythm"},{"issue":"1","key":"2374_CR14","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1177\/030089161009600113","volume":"96","author":"T Ferrara","year":"2010","unstructured":"Ferrara T, Baiotto B, Malinverni G, Caria N, Garibaldi E, Barboni G, et al. Irradiation of pacemakers and cardio-defibrillators in patients submitted to radiotherapy: a clinical experience. Tumori. 2010;96(1):76\u201383.","journal-title":"Tumori"},{"key":"2374_CR15","doi-asserted-by":"publisher","DOI":"10.1007\/s00066-019-01502-0","author":"F Steger","year":"2019","unstructured":"Steger F, Hautmann MG, Suss C, Hubauer U, Ucer E, Maier L, et al. Radiotherapy of patients with cardiac implantable electronic devices according to the DEGRO\/DGK guideline-is the risk of relevant errors overestimated? Strahlentherapie Onkol. 2019. https:\/\/doi.org\/10.1007\/s00066-019-01502-0.","journal-title":"Strahlentherapie Onkol"},{"issue":"4","key":"2374_CR16","doi-asserted-by":"publisher","first-page":"509","DOI":"10.1177\/0003319708315305","volume":"60","author":"A Zweng","year":"2009","unstructured":"Zweng A, Schuster R, Hawlicek R, Weber HS. Life-threatening pacemaker dysfunction associated with therapeutic radiation: a case report. Angiology. 2009;60(4):509\u201312. https:\/\/doi.org\/10.1177\/0003319708315305.","journal-title":"Angiology"},{"issue":"16","key":"2374_CR17","doi-asserted-by":"crossref","first-page":"2879","DOI":"10.1088\/0031-9155\/47\/16\/304","volume":"47","author":"J Mouton","year":"2002","unstructured":"Mouton J, Haug R, Bridier A, Dodinot B, Eschwege F. Influence of high-energy photon beam irradiation on pacemaker operation. Phys Med Biol. 2002;47(16):2879\u201393.","journal-title":"Phys Med Biol"},{"issue":"8","key":"2374_CR18","doi-asserted-by":"publisher","first-page":"2212","DOI":"10.1200\/JCO.2002.20.8.2212","volume":"20","author":"S Hoecht","year":"2002","unstructured":"Hoecht S, Rosenthal P, Sancar D, Behrens S, Hinkelbein W, Hoeller U. Implantable cardiac defibrillators may be damaged by radiation therapy. J Clin Oncol. 2002;20(8):2212\u20133. https:\/\/doi.org\/10.1200\/JCO.2002.20.8.2212.","journal-title":"J Clin Oncol"},{"issue":"1","key":"2374_CR19","doi-asserted-by":"publisher","first-page":"282","DOI":"10.1016\/j.ijrobp.2005.04.047","volume":"63","author":"CW Hurkmans","year":"2005","unstructured":"Hurkmans CW, Scheepers E, Springorum BG, Uiterwaal H. Influence of radiotherapy on the latest generation of implantable cardioverter-defibrillators. Int J Radiat Oncol Biol Phys. 2005;63(1):282\u20139. https:\/\/doi.org\/10.1016\/j.ijrobp.2005.04.047.","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"10","key":"2374_CR20","first-page":"330","volume":"14","author":"GJ Uiterwaal","year":"2006","unstructured":"Uiterwaal GJ, Springorum BG, Scheepers E, de Ruiter GS, Hurkmans CW. Interference detection in implantable defibrillators induced by therapeutic radiation therapy. Neth Heart J. 2006;14(10):330\u20134.","journal-title":"Neth Heart J"},{"issue":"5","key":"2374_CR21","doi-asserted-by":"publisher","first-page":"1525","DOI":"10.1016\/j.ijrobp.2008.06.1903","volume":"73","author":"DY Gelblum","year":"2009","unstructured":"Gelblum DY, Amols H. Implanted cardiac defibrillator care in radiation oncology patient population. Int J Radiat Oncol Biol Phys. 2009;73(5):1525\u201331. https:\/\/doi.org\/10.1016\/j.ijrobp.2008.06.1903.","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"2374_CR22","doi-asserted-by":"publisher","first-page":"260","DOI":"10.1186\/s13014-014-0260-0","volume":"9","author":"M Arenas","year":"2014","unstructured":"Arenas M, Sabater S, Gascon M, Henriquez I, Bueno MJ, Rius A, et al. Quality assurance in radiotherapy: analysis of the causes of not starting or early radiotherapy withdrawal. Radiat Oncol. 2014;9:260. https:\/\/doi.org\/10.1186\/s13014-014-0260-0.","journal-title":"Radiat Oncol"},{"issue":"3","key":"2374_CR23","doi-asserted-by":"publisher","first-page":"840","DOI":"10.1016\/j.ijrobp.2012.05.043","volume":"85","author":"H Hashii","year":"2013","unstructured":"Hashii H, Hashimoto T, Okawa A, Shida K, Isobe T, Hanmura M, et al. Comparison of the effects of high-energy photon beam irradiation (10 and 18 MV) on 2 types of implantable cardioverter-defibrillators. Int J Radiat Oncol Biol Phys. 2013;85(3):840\u20135. https:\/\/doi.org\/10.1016\/j.ijrobp.2012.05.043.","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"1","key":"2374_CR24","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1093\/europace\/eus197","volume":"15","author":"J Elders","year":"2013","unstructured":"Elders J, Kunze-Busch M, Jan Smeenk R, Smeets JL. High incidence of implantable cardioverter defibrillator malfunctions during radiation therapy: neutrons as a probable cause of soft errors. Europace. 2013;15(1):60\u20135. https:\/\/doi.org\/10.1093\/europace\/eus197.","journal-title":"Europace"}],"container-title":["Clinical and Translational Oncology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12094-020-02374-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12094-020-02374-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12094-020-02374-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,5,16]],"date-time":"2021-05-16T23:40:52Z","timestamp":1621208452000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12094-020-02374-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,5,17]]},"references-count":24,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["2374"],"URL":"https:\/\/doi.org\/10.1007\/s12094-020-02374-y","relation":{},"ISSN":["1699-048X","1699-3055"],"issn-type":[{"value":"1699-048X","type":"print"},{"value":"1699-3055","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,5,17]]},"assertion":[{"value":"25 February 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 May 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 May 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors have no conflicts to disclose. No financial support from third parties was obtained.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"The study was approved by the Institutional Review Board.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was waived due to its retrospective nature.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}