{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T15:58:00Z","timestamp":1786982280230,"version":"build-2736575974"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2014,5,31]],"date-time":"2014-05-31T00:00:00Z","timestamp":1401494400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ann Nucl Med"],"published-print":{"date-parts":[[2014,8]]},"DOI":"10.1007\/s12149-014-0859-0","type":"journal-article","created":{"date-parts":[[2014,5,30]],"date-time":"2014-05-30T02:46:04Z","timestamp":1401417964000},"page":"646-655","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Nuclear myocardial perfusion imaging with a cadmium\u2013telluride semiconductor detector gamma camera in patients with acute myocardial infarction"],"prefix":"10.1007","volume":"28","author":[{"given":"Yoshimitsu","family":"Fukushima","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shin-ichiro","family":"Kumita","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tsuneaki","family":"Kawaguchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takatoshi","family":"Maruyama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshiyuki","family":"Kawasaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yasuhiro","family":"Shinkai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2014,5,31]]},"reference":[{"key":"859_CR1","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1056\/NEJMoa0807611","volume":"360","author":"PA Tonino","year":"2009","unstructured":"Tonino PA, De Bruyne B, Pijls NH, Siebert U, Ikeno F, van\u2019t Veer M, et al. Fractional flow reserve versus angiography for guiding percutaneous coronary intervention. N Engl J Med. 2009;360:213\u201324.","journal-title":"N Engl J Med"},{"key":"859_CR2","doi-asserted-by":"crossref","first-page":"907","DOI":"10.1007\/s12350-012-9585-y","volume":"19","author":"HJ Boiten","year":"2012","unstructured":"Boiten HJ, van der Sijde JN, Ruitinga PR, Valkema R, Geleijnse ML, Sijbrands EJ, et al. Long-term prognostic value of exercise technetium-99\u00a0m tetrofosmin myocardial perfusion single-photon emission computed tomography. J Nucl Cardiol. 2012;19:907\u201313.","journal-title":"J Nucl Cardiol"},{"key":"859_CR3","doi-asserted-by":"crossref","first-page":"e39","DOI":"10.1016\/j.nuclcard.2007.09.023","volume":"14","author":"CL Hansen","year":"2007","unstructured":"Hansen CL, Goldstein RA, Akinboboye OO, Berman DS, Botvinick EH, Churchwell KB, et al. Myocardial perfusion and function: single photon emission computed tomography. J Nucl Cardiol. 2007;14:e39\u201360.","journal-title":"J Nucl Cardiol"},{"key":"859_CR4","doi-asserted-by":"crossref","first-page":"R99","DOI":"10.1088\/0031-9155\/51\/13\/R07","volume":"51","author":"RJ Jaszczak","year":"2006","unstructured":"Jaszczak RJ. The early years of single photon emission computed tomography (SPECT): an anthology of selected reminiscences. Phys Med Biol. 2006;51:R99\u2013115.","journal-title":"Phys Med Biol"},{"key":"859_CR5","doi-asserted-by":"crossref","first-page":"2900","DOI":"10.1161\/01.CIR.0000072790.23090.41","volume":"107","author":"R Hachamovitch","year":"2003","unstructured":"Hachamovitch R, Hayes SW, Friedman JD, Cohen I, Berman DS. Comparison of the short-term survival benefit associated with revascularization compared with medical therapy in patients with no prior coronary artery disease undergoing stress myocardial perfusion single photon emission computed tomography. Circulation. 2003;107:2900\u20137.","journal-title":"Circulation"},{"key":"859_CR6","doi-asserted-by":"crossref","first-page":"661","DOI":"10.2967\/jnumed.106.032680","volume":"48","author":"MT Madsen","year":"2007","unstructured":"Madsen MT. Recent advances in SPECT imaging. J Nucl Med. 2007;48:661\u201373.","journal-title":"J Nucl Med"},{"key":"859_CR7","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1007\/s12149-007-0126-8","volume":"22","author":"Y Fukushima","year":"2008","unstructured":"Fukushima Y, Toba M, Ishihara K, Mizumura S, Seino T, Tanaka K, et al. Usefulness of 201TlCl\/123I-BMIPP dual-myocardial SPECT for patients with non-ST segment elevation myocardial infarction. Ann Nucl Med. 2008;22:363\u20139.","journal-title":"Ann Nucl Med"},{"key":"859_CR8","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1016\/j.jcmg.2011.03.010","volume":"4","author":"AM Arruda-Olson","year":"2011","unstructured":"Arruda-Olson AM, Roger VL, Jaffe AS, Hodge DO, Gibbons RJ, Miller TD. Troponin T levels and infarct size by SPECT myocardial perfusion imaging. JACC Cardiovasc Imaging. 2011;4:523\u201333.","journal-title":"JACC Cardiovasc Imaging"},{"key":"859_CR9","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1007\/BF02988500","volume":"15","author":"I Mori","year":"2001","unstructured":"Mori I, Takayama T, Motomura N. The CdTe detector module and its imaging performance. Ann Nucl Med. 2001;15:487\u201394.","journal-title":"Ann Nucl Med"},{"key":"859_CR10","doi-asserted-by":"crossref","first-page":"1297","DOI":"10.1109\/TNS.2002.1039655","volume":"49","author":"T Takahashi","year":"2002","unstructured":"Takahashi T, Mitani T, Kobayashi Y, Kouda M, Sato G, Watanabe S, et al. High-resolution Schottky CdTe diode detector. IEEE Trans Nucl Sci. 2002;49:1297\u2013303.","journal-title":"IEEE Trans Nucl Sci"},{"key":"859_CR11","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1109\/23.682421","volume":"45","author":"C Matsumoto","year":"1998","unstructured":"Matsumoto C, Takahashi T, Takizawa K, Ohno R, Ozaki T, Mori K, et al. Performance of a new Schottkey CdTe detector for hard X-ray spectroscopy. IEEE Trans Nucl Sci. 1998;45:428\u201332.","journal-title":"IEEE Trans Nucl Sci"},{"key":"859_CR12","doi-asserted-by":"crossref","first-page":"726","DOI":"10.1109\/TNS.2010.2042177","volume":"57","author":"T Seino","year":"2010","unstructured":"Seino T, Kobashi K, Kiyanagi Y. A pulsed bias voltage shutdown circuit for a matrix readout system of a CdTe radiation detector. IEEE Trans Nucl Sci. 2010;57:726\u201331.","journal-title":"IEEE Trans Nucl Sci"},{"key":"859_CR13","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1016\/j.nima.2010.11.033","volume":"629","author":"T Seino","year":"2011","unstructured":"Seino T, Ishitsu T, Ueno Y, Kobashi K. Biparametric correction methods using two shapers for In\/CdTe\/Pt radiation detector. Nucl Instrum Methods A. 2011;629:170\u20134.","journal-title":"Nucl Instrum Methods A"},{"key":"859_CR14","doi-asserted-by":"crossref","first-page":"744902","DOI":"10.1117\/12.828514","volume":"7449","author":"H Chen","year":"2009","unstructured":"Chen H, Awadalla SA, Marthandam P, Iniewski K, Lu PH, Bindley G, et al. CZT device with improved sensitivity for medical imaging and homeland security applications. SPIE. 2009;7449:744902.","journal-title":"SPIE"},{"key":"859_CR15","doi-asserted-by":"crossref","first-page":"1567","DOI":"10.1109\/TNS.2008.924089","volume":"55","author":"H Chen","year":"2008","unstructured":"Chen H, Awadalla SA, Harris F, Pinghe Lu, Redden R, Bindley G, et al. Spectral response of THM grown CdZnTe crystals. IEEE Trans Nucl Sci. 2008;55:1567\u201372.","journal-title":"IEEE Trans Nucl Sci"},{"key":"859_CR16","doi-asserted-by":"crossref","first-page":"1573","DOI":"10.1109\/TNS.2008.924069","volume":"55","author":"L Guerin","year":"2008","unstructured":"Guerin L, Verger L, Rebuffel V, Monnet O, et al. A new architecture for pixellated solid state gamma camera used in nuclear medicine. IEEE Trans Nucl Sci. 2008;55:1573\u201380.","journal-title":"IEEE Trans Nucl Sci"},{"key":"859_CR17","doi-asserted-by":"crossref","first-page":"2635","DOI":"10.1088\/0031-9155\/54\/9\/003","volume":"54","author":"K Erlandsson","year":"2009","unstructured":"Erlandsson K, Kacperski K, van Gramberg D, Hutton BF. Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology. Phys Med Biol. 2009;54:2635\u201349.","journal-title":"Phys Med Biol"},{"key":"859_CR18","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1016\/j.jcmg.2007.12.004","volume":"1","author":"T Sharir","year":"2008","unstructured":"Sharir T, Ben-Haim S, Merzon K, Prochorov V, Dickman D, Ben-Haim S, et al. High-speed myocardial perfusion imaging: initial clinical comparison with conventional dual detector anger camera imaging. JACC Cardiovasc Imaging. 2008;1:156\u201363.","journal-title":"JACC Cardiovasc Imaging"},{"key":"859_CR19","doi-asserted-by":"crossref","first-page":"1113","DOI":"10.1007\/s12350-012-9619-5","volume":"19","author":"R Nakazato","year":"2012","unstructured":"Nakazato R, Berman DS, Gransar H, Hyun M, Miranda-Peats R, Kite FC, et al. Prognostic value of quantitative high-speed myocardial perfusion imaging. J Nucl Cardiol. 2012;19:1113\u201323.","journal-title":"J Nucl Cardiol"},{"key":"859_CR20","doi-asserted-by":"crossref","first-page":"46","DOI":"10.2967\/jnumed.109.065532","volume":"51","author":"BA Herzog","year":"2010","unstructured":"Herzog BA, Buechel RR, Katz R, Brueckner M, Husmann L, Burger IA, et al. Nuclear myocardial perfusion imaging with a cadmium\u2013zinc\u2013telluride detector technique: optimized protocol for scan time reduction. J Nucl Med. 2010;51:46\u201351.","journal-title":"J Nucl Med"},{"key":"859_CR21","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1007\/s12149-010-0354-1","volume":"24","author":"K Tsuchiya","year":"2010","unstructured":"Tsuchiya K, Takahashi I, Kawaguchi T, Yokoi K, Morimoto Y, Ishitsu T, et al. Basic performance and stability of a CdTe solid-state detector panel. Ann Nucl Med. 2010;24:301\u201311.","journal-title":"Ann Nucl Med"},{"key":"859_CR22","first-page":"301","volume":"30","author":"FJ Wackers","year":"1989","unstructured":"Wackers FJ, Berman DS, Maddahi J, Watson DD, Beller GA, Strauss HW, et al. Technetium-99\u00a0m hexakis 2-methoxyisobutyl isonitrile: human biodistribution, dosimetry, safety, and preliminary comparison to thallium-201 for myocardial perfusion imaging. J Nucl Med. 1989;30:301\u201311.","journal-title":"J Nucl Med"},{"key":"859_CR23","first-page":"1133","volume":"28","author":"A Kubo","year":"1991","unstructured":"Kubo A, Nakamura K, Sanmiya T, Shimizu S, Hashimoto S, Iwanaga S, et al. Phase I clinical study on 99mTc-MIBI. Kakuigaku. 1991;28:1133\u201342.","journal-title":"Kakuigaku"},{"key":"859_CR24","first-page":"539","volume":"18","author":"MD Cerqueira","year":"2002","unstructured":"Cerqueira MD, Weissman NJ, Dilsizian V, Jacobs AK, Kaul S, Laskey WK, et al. Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Int J Cardiovasc Imaging. 2002;18:539\u201342.","journal-title":"Int J Cardiovasc Imaging"},{"key":"859_CR25","doi-asserted-by":"crossref","first-page":"1036","DOI":"10.2967\/jnumed.109.073411","volume":"51","author":"E Reyes","year":"2010","unstructured":"Reyes E, Stirrup J, Roughton M, D\u2019Souza S, Underwood SR, Anagnostopoulos C. Attenuation of adenosine-induced myocardial perfusion heterogeneity by atenolol and other cardioselective beta-adrenoceptor blockers: a crossover myocardial perfusion imaging study. J Nucl Med. 2010;51:1036\u201343.","journal-title":"J Nucl Med"},{"key":"859_CR26","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1161\/01.CIR.97.6.535","volume":"97","author":"R Hachamovitch","year":"1998","unstructured":"Hachamovitch R, Berman DS, Shaw LJ, Kiat H, Cohen I, Cabico JA, et al. Incremental prognostic value of myocardial perfusion single photon emission computed tomography for the prediction of cardiac death: differential stratification for risk of cardiac death and myocardial infarction. Circulation. 1998;97:535\u201343.","journal-title":"Circulation"},{"key":"859_CR27","first-page":"831","volume":"42","author":"T Sharir","year":"2001","unstructured":"Sharir T, Germano G, Kang X, Lewin HC, Miranda R, Cohen I, et al. Prediction of myocardial infarction versus cardiac death by gated myocardial perfusion SPECT: risk stratification by the amount of stress-induced ischemia and the poststress ejection fraction. J Nucl Med. 2001;42:831\u20137.","journal-title":"J Nucl Med"},{"key":"859_CR28","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1016\/0033-0620(76)90020-7","volume":"19","author":"FJ Klocke","year":"1976","unstructured":"Klocke FJ. Coronary blood flow in man. Prog Cardiovasc Dis. 1976;19:117\u201366.","journal-title":"Prog Cardiovasc Dis"},{"key":"859_CR29","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1253\/circj.69.550","volume":"69","author":"A Kurata","year":"2005","unstructured":"Kurata A, Mochizuki T, Koyama Y, Haraikawa T, Suzuki J, Shigematsu Y, et al. Myocardial perfusion imaging using adenosine triphosphate stress multi-slice spiral computed tomography: alternative to stress myocardial perfusion scintigraphy. Circ J. 2005;69:550\u20137.","journal-title":"Circ J"},{"key":"859_CR30","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1097\/00004728-200403000-00021","volume":"28","author":"K Nikolaou","year":"2004","unstructured":"Nikolaou K, Knez A, Sagmeister S, Wintersperger BJ, Boekstegers P, Steinbeck G, et al. Assessment of myocardial infarctions using multidetector-row computed tomography. J Comput Assist Tomogr. 2004;28:286\u201392.","journal-title":"J Comput Assist Tomogr"},{"key":"859_CR31","doi-asserted-by":"crossref","first-page":"1379","DOI":"10.1161\/01.CIR.101.12.1379","volume":"101","author":"N Al-Saadi","year":"2000","unstructured":"Al-Saadi N, Nagel E, Gross M, Bornstedt A, Schnackenburg B, Klein C, et al. Noninvasive detection of myocardial ischemia from perfusion reserve based on cardiovascular magnetic resonance. Circulation. 2000;101:1379\u201383.","journal-title":"Circulation"},{"key":"859_CR32","doi-asserted-by":"crossref","first-page":"674","DOI":"10.1148\/radiol.2403050740","volume":"240","author":"MR Patel","year":"2006","unstructured":"Patel MR, Albert TS, Kandzari DE, Honeycutt EF, Shaw LK, Sketch MH Jr, et al. Acute myocardial infarction; safety of cardiac MR imaging after percutaneous revascularization with stents. Radiology. 2006;240:674\u201380.","journal-title":"Radiology"}],"container-title":["Annals of Nuclear Medicine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12149-014-0859-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s12149-014-0859-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12149-014-0859-0","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,2]],"date-time":"2019-06-02T00:41:26Z","timestamp":1559436086000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s12149-014-0859-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,5,31]]},"references-count":32,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2014,8]]}},"alternative-id":["859"],"URL":"https:\/\/doi.org\/10.1007\/s12149-014-0859-0","relation":{},"ISSN":["0914-7187","1864-6433"],"issn-type":[{"value":"0914-7187","type":"print"},{"value":"1864-6433","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,5,31]]}}}