{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,7]],"date-time":"2026-11-07T11:27:56Z","timestamp":1794050876048,"version":"4.8.0"},"reference-count":67,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2016,2,20]],"date-time":"2016-02-20T00:00:00Z","timestamp":1455926400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2016,2,20]],"date-time":"2016-02-20T00:00:00Z","timestamp":1455926400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"JSNM working group"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ann Nucl Med"],"published-print":{"date-parts":[[2016,4]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>As a 2-year project of the Japanese Society of Nuclear Medicine working group activity, normal myocardial imaging databases were accumulated and summarized. Stress-rest with gated and non-gated image sets were accumulated for myocardial perfusion imaging and could be used for perfusion defect scoring and normal left ventricular (LV) function analysis. For single-photon emission computed tomography (SPECT) with multi-focal collimator design, databases of supine and prone positions and computed tomography (CT)-based attenuation correction were created. The CT-based correction provided similar perfusion patterns between genders. In phase analysis of gated myocardial perfusion SPECT, a new approach for analyzing dyssynchrony, normal ranges of parameters for phase bandwidth, standard deviation and entropy were determined in four software programs. Although the results were not interchangeable, dependency on gender, ejection fraction and volumes were common characteristics of these parameters. Standardization of <jats:sup>123<\/jats:sup>I-MIBG sympathetic imaging was performed regarding heart-to-mediastinum ratio (HMR) using a calibration phantom method. The HMRs from any collimator types could be converted to the value with medium-energy comparable collimators. Appropriate quantification based on common normal databases and standard technology could play a pivotal role for clinical practice and researches.<\/jats:p>","DOI":"10.1007\/s12149-016-1065-z","type":"journal-article","created":{"date-parts":[[2016,2,20]],"date-time":"2016-02-20T04:29:31Z","timestamp":1455942571000},"page":"188-199","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":105,"title":["Normal values and standardization of parameters in nuclear cardiology: Japanese Society of Nuclear Medicine working group database"],"prefix":"10.1007","volume":"30","author":[{"given":"Kenichi","family":"Nakajima","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naoya","family":"Matsumoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tokuo","family":"Kasai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shinro","family":"Matsuo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keisuke","family":"Kiso","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Koichi","family":"Okuda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2016,2,20]]},"reference":[{"key":"1065_CR1","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1007\/s12149-009-0337-2","volume":"24","author":"K Nakajima","year":"2010","unstructured":"Nakajima K. Normal values for nuclear cardiology: Japanese databases for myocardial perfusion, fatty acid and sympathetic imaging and left ventricular function. Ann Nucl Med. 2010;24:125\u201335.","journal-title":"Ann Nucl Med"},{"key":"1065_CR2","first-page":"912","volume":"45","author":"V Go","year":"2004","unstructured":"Go V, Bhatt MR, Hendel RC. The diagnostic and prognostic value of ECG-gated SPECT myocardial perfusion imaging. J Nucl Med. 2004;45:912\u201321.","journal-title":"J Nucl Med"},{"key":"1065_CR3","first-page":"1871","volume":"34","author":"EG DePuey","year":"1993","unstructured":"DePuey EG, Nichols K, Dobrinsky C. Left ventricular ejection fraction assessed from gated technetium-99\u00a0m-sestamibi SPECT. J Nucl Med. 1993;34:1871\u20136.","journal-title":"J Nucl Med"},{"key":"1065_CR4","first-page":"2138","volume":"36","author":"G Germano","year":"1995","unstructured":"Germano G, Kiat H, Kavanagh PB, Moriel M, Mazzanti M, Su HT, et al. Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med. 1995;36:2138\u201347.","journal-title":"J Nucl Med"},{"key":"1065_CR5","doi-asserted-by":"publisher","first-page":"420","DOI":"10.1016\/j.nuclcard.2007.06.009","volume":"14","author":"EV Garcia","year":"2007","unstructured":"Garcia EV, Faber TL, Cooke CD, Folks RD, Chen J, Santana C. The increasing role of quantification in clinical nuclear cardiology: the Emory approach. J Nucl Cardiol. 2007;14:420\u201332.","journal-title":"J Nucl Cardiol"},{"key":"1065_CR6","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1016\/j.nuclcard.2007.06.008","volume":"14","author":"G Germano","year":"2007","unstructured":"Germano G, Kavanagh PB, Slomka PJ, Van Kriekinge SD, Pollard G, Berman DS. Quantitation in gated perfusion SPECT imaging: the Cedars-Sinai approach. J Nucl Cardiol. 2007;14:433\u201354.","journal-title":"J Nucl Cardiol"},{"key":"1065_CR7","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1016\/j.nuclcard.2007.06.006","volume":"14","author":"EP Ficaro","year":"2007","unstructured":"Ficaro EP, Lee BC, Kritzman JN, Corbett JR. Corridor4DM: the Michigan method for quantitative nuclear cardiology. J Nucl Cardiol. 2007;14:455\u201365.","journal-title":"J Nucl Cardiol"},{"key":"1065_CR8","first-page":"136","volume":"34","author":"K Kobayashi","year":"2014","unstructured":"Kobayashi K, Tsukamoto K. Myocardial image analysis software Heart Risk View, Heart Score View and Heart Function View (In Japanese). Kakuigaku Gijutsu (Nucl Med Techonology). 2014;34:136\u201344.","journal-title":"Kakuigaku Gijutsu (Nucl Med Techonology)"},{"key":"1065_CR9","doi-asserted-by":"publisher","first-page":"812","DOI":"10.1007\/s12149-014-0875-0","volume":"28","author":"I Nakae","year":"2014","unstructured":"Nakae I, Hayashi H, Matsumoto T, Mitsunami K, Horie M. Clinical usefulness of a novel program \u201cHeart Function View\u201d for evaluating cardiac function from gated myocardial perfusion SPECT. Ann Nucl Med. 2014;28:812\u201323.","journal-title":"Ann Nucl Med"},{"key":"1065_CR10","doi-asserted-by":"publisher","first-page":"1163","DOI":"10.1007\/s00259-013-2431-x","volume":"40","author":"K Nakajima","year":"2013","unstructured":"Nakajima K, Okuda K, Nystrom K, Richter J, Minarik D, Wakabayashi H, et al. Improved quantification of small hearts for gated myocardial perfusion imaging. Eur J Nucl Med Mol Imaging. 2013;40:1163\u201370.","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"1065_CR11","doi-asserted-by":"publisher","first-page":"1296","DOI":"10.2967\/jnumed.108.059592","volume":"50","author":"L Shaw","year":"2009","unstructured":"Shaw L, Narula J. Risk Assessment and Predictive Value of Coronary Artery Disease Testing. J Nucl Med. 2009;50:1296\u2013306.","journal-title":"J Nucl Med"},{"key":"1065_CR12","doi-asserted-by":"publisher","first-page":"2035","DOI":"10.1253\/circj.CJ-08-0488","volume":"72","author":"N Matsumoto","year":"2008","unstructured":"Matsumoto N, Sato Y, Suzuki Y, Kasama S, Nakano Y, Kato M, et al. Incremental Prognostic Value of Cardiac Function Assessed by ECG-Gated Myocardial Perfusion SPECT for the Prediction of Future Acute Coronary Syndrome. Circ J. 2008;72:2035\u20139.","journal-title":"Circ J"},{"key":"1065_CR13","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1007\/s00259-007-0608-x","volume":"35","author":"T Nishimura","year":"2008","unstructured":"Nishimura T, Nakajima K, Kusuoka H, Yamashina A, Nishimura S. Prognostic study of risk stratification among Japanese patients with ischemic heart disease using gated myocardial perfusion SPECT: J-ACCESS study. Eur J Nucl Med Mol Imaging. 2008;35:319\u201328.","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"1065_CR14","doi-asserted-by":"publisher","first-page":"505","DOI":"10.1007\/s12149-007-0059-2","volume":"21","author":"K Nakajima","year":"2007","unstructured":"Nakajima K, Kumita S, Ishida Y, Momose M, Hashimoto J, Morita K, et al. Creation and characterization of Japanese standards for myocardial perfusion SPECT: database from the Japanese Society of Nuclear Medicine Working Group. Ann Nucl Med. 2007;21:505\u201311.","journal-title":"Ann Nucl Med"},{"key":"1065_CR15","doi-asserted-by":"publisher","first-page":"517","DOI":"10.1007\/s12149-009-0269-x","volume":"23","author":"S Matsuo","year":"2009","unstructured":"Matsuo S, Nakajima K, Yamashina S, Sakata K, Momose M, Hashimoto J, et al. Characterization of Japanese standards for myocardial sympathetic and metabolic imaging in comparison with perfusion imaging. Ann Nucl Med. 2009;23:517\u201322.","journal-title":"Ann Nucl Med"},{"key":"1065_CR16","doi-asserted-by":"publisher","first-page":"1088","DOI":"10.1007\/s00259-006-0321-1","volume":"34","author":"K Nakajima","year":"2007","unstructured":"Nakajima K, Kusuoka H, Nishimura S, Yamashina A, Nishimura T. Normal limits of ejection fraction and volumes determined by gated SPECT in clinically normal patients without cardiac events: a study based on the J-ACCESS database. Eur J Nucl Med Mol Imaging. 2007;34:1088\u201396.","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"1065_CR17","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1007\/s12149-009-0331-8","volume":"24","author":"K Nakajima","year":"2010","unstructured":"Nakajima K, Matsuo S, Kawano M, Matsumoto N, Hashimoto J, Yoshinaga K, et al. The validity of multi-center common normal database for identifying myocardial ischemia: Japanese Society of Nuclear Medicine working group database. Ann Nucl Med. 2010;24:99\u2013105.","journal-title":"Ann Nucl Med"},{"key":"1065_CR18","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1016\/j.nuclcard.2007.11.004","volume":"15","author":"J Chen","year":"2008","unstructured":"Chen J, Henneman MM, Trimble MA, Bax JJ, Borges-Neto S, Iskandrian AE, et al. Assessment of left ventricular mechanical dyssynchrony by phase analysis of ECG-gated SPECT myocardial perfusion imaging. J Nucl Cardiol. 2008;15:127\u201336.","journal-title":"J Nucl Cardiol."},{"key":"1065_CR19","doi-asserted-by":"publisher","first-page":"970","DOI":"10.1007\/s12350-014-9916-2","volume":"21","author":"K Nakajima","year":"2014","unstructured":"Nakajima K, Okuda K, Yoshimura M, Matsuo S, Wakabayashi H, Imanishi Y, et al. Multicenter cross-calibration of I-123 metaiodobenzylguanidine heart-to-mediastinum ratios to overcome camera-collimator variations. J Nucl Cardiol. 2014;21:970\u20138.","journal-title":"J Nucl Cardiol"},{"key":"1065_CR20","doi-asserted-by":"publisher","first-page":"843","DOI":"10.1016\/j.nuclcard.2007.08.002","volume":"14","author":"K Nakajima","year":"2007","unstructured":"Nakajima K, Matsubara K, Ishikawa T, Motomura N, Maeda R, Akhter N, et al. Correction of iodine-123-labeled meta-iodobenzylguanidine uptake with multi-window methods for standardization of the heart-to-mediastinum ratio. J Nucl Cardiol. 2007;14:843\u201351.","journal-title":"J Nucl Cardiol"},{"key":"1065_CR21","doi-asserted-by":"publisher","first-page":"2769","DOI":"10.1016\/j.jacc.2009.12.066","volume":"55","author":"MJ Boogers","year":"2010","unstructured":"Boogers MJ, Borleffs CJ, Henneman MM, van Bommel RJ, van Ramshorst J, Boersma E, et al. Cardiac sympathetic denervation assessed with 123-iodine metaiodobenzylguanidine imaging predicts ventricular arrhythmias in implantable cardioverter-defibrillator patients. J Am Coll Cardiol. 2010;55:2769\u201377.","journal-title":"J Am Coll Cardiol"},{"issue":"Suppl 4","key":"1065_CR22","doi-asserted-by":"publisher","first-page":"25S","DOI":"10.2967\/jnumed.115.157503","volume":"56","author":"AC Dimitriu-Leen","year":"2015","unstructured":"Dimitriu-Leen AC, Scholte AJ, Jacobson AF. 123I-MIBG SPECT for evaluation of patients with heart failure. J Nucl Med. 2015;56(Suppl 4):25S\u201330S.","journal-title":"J Nucl Med"},{"key":"1065_CR23","doi-asserted-by":"publisher","first-page":"1290","DOI":"10.1161\/CIRCULATIONAHA.107.688101","volume":"116","author":"AJ Einstein","year":"2007","unstructured":"Einstein AJ, Moser KW, Thompson RC, Cerqueira MD, Henzlova MJ. Radiation dose to patients from cardiac diagnostic imaging. Circulation. 2007;116:1290\u2013305.","journal-title":"Circulation"},{"key":"1065_CR24","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1007\/s12350-012-9633-7","volume":"20","author":"S Mathur","year":"2013","unstructured":"Mathur S, Heller GV, Bateman TM, Ruffin R, Yekta A, Katten D, et al. Clinical value of stress-only Tc-99m SPECT imaging: importance of attenuation correction. J Nucl Cardiol. 2013;20:27\u201337.","journal-title":"J Nucl Cardiol"},{"key":"1065_CR25","doi-asserted-by":"publisher","first-page":"2386","DOI":"10.1253\/circj.CJ-12-0081","volume":"76","author":"T Ueyama","year":"2012","unstructured":"Ueyama T, Takehana K, Maeba H, Iwasaka T. Prognostic value of normal stress-only technetium-99m myocardial perfusion imaging protocol. Comparison with standard stress-rest protocol. Circ J. 2012;76:2386\u201391.","journal-title":"Circ J"},{"key":"1065_CR26","doi-asserted-by":"publisher","first-page":"422","DOI":"10.1007\/s12350-009-9049-1","volume":"16","author":"K Nakajima","year":"2009","unstructured":"Nakajima K, Okuda K, Kawano M, Matsuo S, Slomka P, Germano G, et al. The importance of population-specific normal database for quantification of myocardial ischemia: comparison between Japanese 360 and 180-degree databases and a US database. J Nucl Cardiol. 2009;16:422\u201330.","journal-title":"J Nucl Cardiol"},{"key":"1065_CR27","doi-asserted-by":"publisher","first-page":"2900","DOI":"10.1161\/01.CIR.0000072790.23090.41","volume":"107","author":"R Hachamovitch","year":"2003","unstructured":"Hachamovitch R, Hayes SW, Friedman JD, Cohen I, Berman DS. Comparison of the short-term survival benefit associated with revascularization compared with medical therapy in patients with no prior coronary artery disease undergoing stress myocardial perfusion single photon emission computed tomography. Circulation. 2003;107:2900\u20137.","journal-title":"Circulation"},{"key":"1065_CR28","doi-asserted-by":"publisher","first-page":"1012","DOI":"10.1093\/eurheartj\/ehq500","volume":"32","author":"R Hachamovitch","year":"2011","unstructured":"Hachamovitch R, Rozanski A, Shaw LJ, Stone GW, Thomson LE, Friedman JD, et al. Impact of ischaemia and scar on the therapeutic benefit derived from myocardial revascularization vs. medical therapy among patients undergoing stress-rest myocardial perfusion scintigraphy. Eur Heart J. 2011;32:1012\u201324.","journal-title":"Eur Heart J"},{"key":"1065_CR29","doi-asserted-by":"publisher","first-page":"2501","DOI":"10.1093\/eurheartj\/ehq277","volume":"31","author":"W Wijns","year":"2010","unstructured":"Task Force on Myocardial Revascularization of the European Society of C, the European Association for Cardio-Thoracic S, European Association for Percutaneous Cardiovascular I, Wijns W, Kolh P, Danchin N, et al. Guidelines on myocardial revascularization. Eur Heart J. 2010;31:2501\u201355.","journal-title":"Eur Heart J"},{"key":"1065_CR30","doi-asserted-by":"publisher","first-page":"1897","DOI":"10.2967\/jnumed.112.107417","volume":"53","author":"L Imbert","year":"2012","unstructured":"Imbert L, Poussier S, Franken PR, Songy B, Verger A, Morel O, et al. Compared performance of high-sensitivity cameras dedicated to myocardial perfusion SPECT: a comprehensive analysis of phantom and human images. J Nucl Med. 2012;53:1897\u2013903.","journal-title":"J Nucl Med"},{"key":"1065_CR31","doi-asserted-by":"publisher","first-page":"2727","DOI":"10.1253\/circj.CJ-14-0612","volume":"78","author":"H Tanaka","year":"2014","unstructured":"Tanaka H, Chikamori T, Tanaka N, Hida S, Igarashi Y, Yamashita J, et al. Diagnostic performance of a novel cadmium-zinc-telluride gamma camera system assessed using fractional flow reserve. Circ J. 2014;78:2727\u201334.","journal-title":"Circ J"},{"key":"1065_CR32","doi-asserted-by":"publisher","first-page":"1169","DOI":"10.1253\/circj.CJ-13-1316","volume":"78","author":"Y Nishiyama","year":"2014","unstructured":"Nishiyama Y, Miyagawa M, Kawaguchi N, Nakamura M, Kido T, Kurata A, et al. Combined supine and prone myocardial perfusion single-photon emission computed tomography with a cadmium zinc telluride camera for detection of coronary artery disease. Circ J. 2014;78:1169\u201375.","journal-title":"Circ J"},{"key":"1065_CR33","doi-asserted-by":"publisher","first-page":"1920","DOI":"10.1007\/s00259-015-3142-2","volume":"42","author":"F Caobelli","year":"2015","unstructured":"Caobelli F, Thackeray JT, Soffientini A, Bengel FM, Pizzocaro C, Guerra UP. Feasibility of one-eighth time gated myocardial perfusion SPECT functional imaging using IQ-SPECT. Eur J Nucl Med Mol Imaging. 2015;42:1920\u20138.","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"1065_CR34","doi-asserted-by":"publisher","first-page":"707","DOI":"10.1007\/s12149-014-0880-3","volume":"28","author":"Y Horiguchi","year":"2014","unstructured":"Horiguchi Y, Ueda T, Shiomori T, Kanna M, Matsushita H, Kawaminami T, et al. Validation of a short-scan-time imaging protocol for thallium-201 myocardial SPECT with a multifocal collimator. Ann Nucl Med. 2014;28:707\u201315.","journal-title":"Ann Nucl Med"},{"key":"1065_CR35","doi-asserted-by":"publisher","first-page":"452","DOI":"10.1007\/s12149-015-0965-7","volume":"29","author":"S Matsuo","year":"2015","unstructured":"Matsuo S, Nakajima K, Onoguchi M, Wakabayash H, Okuda K, Kinuya S. Nuclear myocardial perfusion imaging using thallium-201 with a novel multifocal collimator SPECT\/CT: IQ-SPECT versus conventional protocols in normal subjects. Ann Nucl Med. 2015;29:452\u20139.","journal-title":"Ann Nucl Med"},{"key":"1065_CR36","doi-asserted-by":"publisher","first-page":"1740","DOI":"10.2967\/jnumed.114.142794","volume":"56","author":"K Nakajima","year":"2015","unstructured":"Nakajima K, Okuda K, Matsuo S, Kondo C, Sarai M, Horiguchi Y, et al. Multicenter normal Tl-201 databases with multifocal collimators for supine, prone and CT-based corrections (Abstract). J Nucl Med. 2015;56:1740.","journal-title":"J Nucl Med"},{"key":"1065_CR37","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1007\/BF02971243","volume":"13","author":"DS Berman","year":"2006","unstructured":"Berman DS, Kang X, Nishina H, Slomka PJ, Shaw LJ, Hayes SW, et al. Diagnostic accuracy of gated Tc-99m sestamibi stress myocardial perfusion SPECT with combined supine and prone acquisitions to detect coronary artery disease in obese and nonobese patients. J Nucl Cardiol. 2006;13:191\u2013201.","journal-title":"J Nucl Cardiol"},{"key":"1065_CR38","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1016\/j.nuclcard.2006.10.021","volume":"14","author":"PJ Slomka","year":"2007","unstructured":"Slomka PJ, Nishina H, Abidov A, Hayes SW, Friedman JD, Berman DS, et al. Combined quantitative supine-prone myocardial perfusion SPECT improves detection of coronary artery disease and normalcy rates in women. J Nucl Cardiol. 2007;14:44\u201352.","journal-title":"J Nucl Cardiol"},{"key":"1065_CR39","doi-asserted-by":"publisher","first-page":"1033","DOI":"10.1097\/MNM.0b013e32834b69e1","volume":"32","author":"K Okuda","year":"2011","unstructured":"Okuda K, Nakajima K, Matsuo S, Wakabayashi H, Taki J, Kinuya S. Cause of apical thinning on attenuation-corrected myocardial perfusion SPECT. Nucl Med Commun. 2011;32:1033\u20139.","journal-title":"Nucl Med Commun"},{"key":"1065_CR40","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1016\/j.nuclcard.2003.12.001","volume":"11","author":"GV Heller","year":"2004","unstructured":"Heller GV, Links J, Bateman TM, Ziffer JA, Ficaro E, Cohen MC, et al. American Society of Nuclear Cardiology and Society of Nuclear Medicine joint position statement: attenuation correction of myocardial perfusion SPECT scintigraphy. J Nucl Cardiol. 2004;11:229\u201330.","journal-title":"J Nucl Cardiol"},{"key":"1065_CR41","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1067\/mnc.2002.122676","volume":"9","author":"M O\u2019Connor","year":"2002","unstructured":"O\u2019Connor M, Kemp B, Anstett F, Christian P, Ficaro EP, Frey E, et al. A multicenter evaluation of commercial attenuation compensation techniques in cardiac SPECT using phantom models. J Nucl Cardiol. 2002;9:361\u201376.","journal-title":"J Nucl Cardiol"},{"key":"1065_CR42","doi-asserted-by":"publisher","first-page":"210","DOI":"10.1007\/BF00279071","volume":"11","author":"J Machac","year":"1985","unstructured":"Machac J, Horowitz SF, Fagerstrom R, Levine R, Goldsmith SJ. Characterization and automatic identification of ECG conduction abnormalities using segmental multiharmonic Fourier analysis of gated blood-pool scintigrams. Eur J Nucl Med. 1985;11:210\u20136.","journal-title":"Eur J Nucl Med"},{"key":"1065_CR43","doi-asserted-by":"publisher","first-page":"809","DOI":"10.1016\/0002-8703(85)90643-X","volume":"109","author":"K Nakajima","year":"1985","unstructured":"Nakajima K, Bunko H, Tada A, Tonami N, Hisada K, Misaki T, et al. Nuclear tomographic phase analysis: localization of accessory conduction pathway in patients with Wolff-Parkinson-White syndrome. Am Heart J. 1985;109:809\u201315.","journal-title":"Am Heart J"},{"key":"1065_CR44","doi-asserted-by":"publisher","first-page":"687","DOI":"10.1016\/j.nuclcard.2005.06.088","volume":"12","author":"J Chen","year":"2005","unstructured":"Chen J, Garcia EV, Folks RD, Cooke CD, Faber TL, Tauxe EL, et al. Onset of left ventricular mechanical contraction as determined by phase analysis of ECG-gated myocardial perfusion SPECT imaging: development of a diagnostic tool for assessment of cardiac mechanical dyssynchrony. J Nucl Cardiol. 2005;12:687\u201395.","journal-title":"J Nucl Cardiol"},{"key":"1065_CR45","first-page":"1185","volume":"35","author":"CD Cooke","year":"1994","unstructured":"Cooke CD, Garcia EV, Cullom SJ, Faber TL, Pettigrew RI. Determining the accuracy of calculating systolic wall thickening using a fast Fourier transform approximation: a simulation study based on canine and patient data. J Nucl Med. 1994;35:1185\u201392.","journal-title":"J Nucl Med"},{"key":"1065_CR46","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1016\/j.nuclcard.2005.05.006","volume":"12","author":"JW O\u2019Connell","year":"2005","unstructured":"O\u2019Connell JW, Schreck C, Moles M, Badwar N, DeMarco T, Olgin J, et al. A unique method by which to quantitate synchrony with equilibrium radionuclide angiography. J Nucl Cardiol. 2005;12:441\u201350.","journal-title":"J Nucl Cardiol"},{"key":"1065_CR47","doi-asserted-by":"publisher","first-page":"1104","DOI":"10.2967\/jnumed.107.039925","volume":"48","author":"MM Henneman","year":"2007","unstructured":"Henneman MM, Chen J, Dibbets-Schneider P, Stokkel MP, Bleeker GB, Ypenburg C, et al. Can LV dyssynchrony as assessed with phase analysis on gated myocardial perfusion SPECT predict response to CRT? J Nucl Med. 2007;48:1104\u201311.","journal-title":"J Nucl Med"},{"key":"1065_CR48","doi-asserted-by":"publisher","first-page":"2608","DOI":"10.1161\/CIRCULATIONAHA.107.743120","volume":"117","author":"ES Chung","year":"2008","unstructured":"Chung ES, Leon AR, Tavazzi L, Sun JP, Nihoyannopoulos P, Merlino J, et al. Results of the predictors of response to CRT (PROSPECT) trial. Circulation. 2008;117:2608\u201316.","journal-title":"Circulation"},{"key":"1065_CR49","doi-asserted-by":"publisher","first-page":"1944","DOI":"10.1016\/j.jacc.2008.11.062","volume":"53","author":"NM Hawkins","year":"2009","unstructured":"Hawkins NM, Petrie MC, Burgess MI, McMurray JJ. Selecting patients for cardiac resynchronization therapy: the fallacy of echocardiographic dyssynchrony. J Am Coll Cardiol. 2009;53:1944\u201359.","journal-title":"J Am Coll Cardiol"},{"key":"1065_CR50","doi-asserted-by":"publisher","DOI":"10.1007\/s12350-015-0333-y","author":"K Nakajima","year":"2016","unstructured":"Nakajima K, Okuda K, Matsuo S, Kiso K, Kinuya S, Garcia EV. Comparison of phase dyssynchrony analysis using gated myocardial perfusion imaging with four software programs: Based on the Japanese Society of Nuclear Medicine working group normal database. J Nucl Cardiol. 2016. doi:10.1007\/s12350-015-0333-y.","journal-title":"J Nucl Cardiol"},{"issue":"Suppl 4","key":"1065_CR51","doi-asserted-by":"publisher","first-page":"11S","DOI":"10.2967\/jnumed.114.142794","volume":"56","author":"K Nakajima","year":"2015","unstructured":"Nakajima K, Nakata T. Cardiac 123I-MIBG Imaging for clinical decision making: 22-year experience in Japan. J Nucl Med. 2015;56(Suppl 4):11S\u20139S.","journal-title":"J Nucl Med"},{"key":"1065_CR52","doi-asserted-by":"publisher","first-page":"2212","DOI":"10.1016\/j.jacc.2010.01.014","volume":"55","author":"AF Jacobson","year":"2010","unstructured":"Jacobson AF, Senior R, Cerqueira MD, Wong ND, Thomas GS, Lopez VA, et al. Myocardial iodine-123 meta-iodobenzylguanidine imaging and cardiac events in heart failure. Results of the prospective ADMIRE-HF (AdreView Myocardial Imaging for Risk Evaluation in Heart Failure) study. J Am Coll Cardiol. 2010;55:2212\u201321.","journal-title":"J Am Coll Cardiol"},{"key":"1065_CR53","doi-asserted-by":"publisher","first-page":"772","DOI":"10.1016\/j.jcmg.2013.02.007","volume":"6","author":"T Nakata","year":"2013","unstructured":"Nakata T, Nakajima K, Yamashina S, Yamada T, Momose M, Kasama S, et al. A pooled analysis of multicenter cohort studies of 123I-mIBG imaging of sympathetic innervation for assessment of long-term prognosis in heart failure. JACC Cardiovasc Imaging. 2013;6:772\u201384.","journal-title":"JACC Cardiovasc Imaging"},{"key":"1065_CR54","doi-asserted-by":"publisher","first-page":"996","DOI":"10.1093\/ehjci\/jeu044","volume":"15","author":"DO Verschure","year":"2014","unstructured":"Verschure DO, Veltman CE, Manrique A, Somsen GA, Koutelou M, Katsikis A, et al. For what endpoint does myocardial 123I-MIBG scintigraphy have the greatest prognostic value in patients with chronic heart failure? Results of a pooled individual patient data meta-analysis. Eur Heart J Cardiovasc Imaging. 2014;15:996\u20131003.","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"1065_CR55","doi-asserted-by":"publisher","first-page":"535","DOI":"10.1007\/s00259-007-0639-3","volume":"35","author":"D Agostini","year":"2008","unstructured":"Agostini D, Verberne HJ, Burchert W, Knuuti J, Povinec P, Sambuceti G, et al. I-123-mIBG myocardial imaging for assessment of risk for a major cardiac event in heart failure patients: insights from a retrospective European multicenter study. Eur J Nucl Med Mol Imaging. 2008;35:535\u201346.","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"1065_CR56","doi-asserted-by":"publisher","first-page":"623","DOI":"10.1016\/S1071-3581(03)00652-4","volume":"10","author":"Y Inoue","year":"2003","unstructured":"Inoue Y, Suzuki A, Shirouzu I, Machida T, Yoshizawa Y, Akita F, et al. Effect of collimator choice on quantitative assessment of cardiac iodine 123 MIBG uptake. J Nucl Cardiol. 2003;10:623\u201332.","journal-title":"J Nucl Cardiol"},{"key":"1065_CR57","doi-asserted-by":"publisher","first-page":"547","DOI":"10.1007\/s00259-007-0611-2","volume":"35","author":"HJ Verberne","year":"2008","unstructured":"Verberne HJ, Habraken JB, van Eck-Smit BL, Agostini D, Jacobson AF. Variations in 123I-metaiodobenzylguanidine (MIBG) late heart mediastinal ratios in chronic heart failure: a need for standardisation and validation. Eur J Nucl Med Mol Imaging. 2008;35:547\u201353.","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"1065_CR58","doi-asserted-by":"publisher","first-page":"1802","DOI":"10.1007\/s00259-010-1491-4","volume":"37","author":"A Flotats","year":"2010","unstructured":"Flotats A, Carrio I, Agostini D, Le Guludec D, Marcassa C, Schafers M, et al. Proposal for standardization of 123I-metaiodobenzylguanidine (MIBG) cardiac sympathetic imaging by the EANM Cardiovascular Committee and the European Council of Nuclear Cardiology. Eur J Nucl Med Mol Imaging. 2010;37:1802\u201312.","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"1065_CR59","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1007\/s00259-011-1963-1","volume":"39","author":"K Nakajima","year":"2012","unstructured":"Nakajima K, Okuda K, Matsuo S, Yoshita M, Taki J, Yamada M, et al. Standardization of metaiodobenzylguanidine heart to mediastinum ratio using a calibration phantom: effects of correction on normal databases and a multicentre study. Eur J Nucl Med Mol Imaging. 2012;39:113\u20139.","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"1065_CR60","doi-asserted-by":"publisher","first-page":"e0120540","DOI":"10.1371\/journal.pone.0120540","volume":"10","author":"M Yoshita","year":"2015","unstructured":"Yoshita M, Arai H, Arai H, Arai T, Asada T, Fujishiro H, et al. Diagnostic accuracy of 123I-meta-iodobenzylguanidine myocardial scintigraphy in dementia with Lewy bodies: a multicenter study. PLoS One. 2015;10:e0120540.","journal-title":"PLoS One"},{"key":"1065_CR61","doi-asserted-by":"publisher","first-page":"1673","DOI":"10.1007\/s00259-014-2759-x","volume":"41","author":"K Nakajima","year":"2014","unstructured":"Nakajima K, Nakata T, Yamada T, Yamashina S, Momose M, Kasama S, et al. A prediction model for 5-year cardiac mortality in patients with chronic heart failure using 123I-metaiodobenzylguanidine imaging. Eur J Nucl Med Mol Imaging. 2014;41:1673\u201382.","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"1065_CR62","doi-asserted-by":"publisher","DOI":"10.1093\/ehjci\/jev322","author":"K Nakajima","year":"2016","unstructured":"Nakajima K, Nakata T, Matsuo S, Jacobson AF. Creation of mortality risk charts using 123I meta-iodobenzylguanidine heart-to-mediastinum ratio in patients with heart failure: 2- and 5-year risk models. Eur Heart J Cardiovasc Imaging. 2016. doi:10.1093\/ehjci\/jev322.","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"1065_CR63","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1007\/s00259-015-3173-8","volume":"43","author":"K Okuda","year":"2016","unstructured":"Okuda K, Nakajima K, Sugino S, Kirihara Y, Matsuo S, Taki J, et al. Development and validation of a direct-comparison method for cardiac 123I-metaiodobenzylguanidine washout rates derived from late 3-hour and 4-hour imaging. Eur J Nucl Med Mol Imaging. 2016;43:319\u201325.","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"1065_CR64","doi-asserted-by":"publisher","first-page":"1912","DOI":"10.1007\/s00259-015-3141-3","volume":"42","author":"D Bellevre","year":"2015","unstructured":"Bellevre D, Manrique A, Legallois D, Bross S, Baavour R, Roth N, et al. First determination of the heart-to-mediastinum ratio using cardiac dual isotope (123I-MIBG\/99mTc-tetrofosmin) CZT imaging in patients with heart failure: the ADRECARD study. Eur J Nucl Med Mol Imaging. 2015;42:1912\u20139.","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"1065_CR65","doi-asserted-by":"publisher","first-page":"386","DOI":"10.1007\/s00259-015-3258-4","volume":"43","author":"K Nakajima","year":"2016","unstructured":"Nakajima K, Okuda K, Matsuo S, Agostini D. The time has come to standardize 123I-MIBG heart-to-mediastinum ratios including planar and SPECT methods. Eur J Nucl Med Mol Imaging. 2016;43:386\u20138.","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"1065_CR66","doi-asserted-by":"publisher","first-page":"1043","DOI":"10.1007\/s00259-015-2989-6","volume":"42","author":"A Lebasnier","year":"2015","unstructured":"Lebasnier A, Lamotte G, Manrique A, Peyronnet D, Bouvard G, Defer G, et al. Potential diagnostic value of regional myocardial adrenergic imaging using 123I-MIBG SPECT to identify patients with Lewy body diseases. Eur J Nucl Med Mol Imaging. 2015;42:1043\u201351.","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"1065_CR67","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1007\/s12410-015-9368-3","volume":"9","author":"A Flotats","year":"2016","unstructured":"Flotats A, Carrio I. Cardiac innervation imaging: implications for risk stratification and therapeutic decision-making. Curr Cardiovasc Imaging Rep. 2016;9:6.","journal-title":"Curr Cardiovasc Imaging Rep"}],"container-title":["Annals of Nuclear Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12149-016-1065-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12149-016-1065-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12149-016-1065-z","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12149-016-1065-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,9,2]],"date-time":"2021-09-02T20:18:09Z","timestamp":1630613889000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12149-016-1065-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,2,20]]},"references-count":67,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2016,4]]}},"alternative-id":["1065"],"URL":"https:\/\/doi.org\/10.1007\/s12149-016-1065-z","relation":{},"ISSN":["0914-7187","1864-6433"],"issn-type":[{"value":"0914-7187","type":"print"},{"value":"1864-6433","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,2,20]]},"assertion":[{"value":"24 December 2015","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 January 2016","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 February 2016","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"KN has collaborative research with Fujifilm RI Pharma Co., Ltd., which supplies 123I-MIBG in Japan and developed software. KN also was involved in developing cardiac software with Nihon Medi-Physics (Tokyo, Japan).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}