{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:52:42Z","timestamp":1787759562551,"version":"build-2784847793"},"reference-count":11,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2022,2,9]],"date-time":"2022-02-09T00:00:00Z","timestamp":1644364800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2022,2,9]],"date-time":"2022-02-09T00:00:00Z","timestamp":1644364800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ann Nucl Med"],"published-print":{"date-parts":[[2022,4]]},"DOI":"10.1007\/s12149-022-01721-z","type":"journal-article","created":{"date-parts":[[2022,2,9]],"date-time":"2022-02-09T06:03:09Z","timestamp":1644386589000},"page":"420-426","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Initial evaluation of a new maximum-likelihood attenuation correction factor-based attenuation correction for time-of-flight brain PET"],"prefix":"10.1007","volume":"36","author":[{"given":"Tetsuro","family":"Mizuta","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tetsuya","family":"Kobayashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshiyuki","family":"Yamakawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kohei","family":"Hanaoka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shota","family":"Watanabe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daisuke","family":"Morimoto-Ishikawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takahiro","family":"Yamada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hayato","family":"Kaida","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kazunari","family":"Ishii","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,2,9]]},"reference":[{"key":"1721_CR1","doi-asserted-by":"publisher","first-page":"885","DOI":"10.1088\/0031-9155\/57\/4\/885","volume":"57","author":"M Defrise","year":"2012","unstructured":"Defrise M, Rezaei A, Nuyts J. Time-of-flight PET data determine the attenuation sinogram up to a constant. Phys Med Biol. 2012;57:885\u201399.","journal-title":"Phys Med Biol"},{"issue":"7","key":"1721_CR2","doi-asserted-by":"publisher","first-page":"1563","DOI":"10.1109\/TMI.2014.2318175","volume":"33","author":"A Rezaei","year":"2014","unstructured":"Rezaei A, Defrise M, Nuyts J. ML-reconstruction for TOF-PET with simultaneous estimation of the Attenuation Factors. IEEE Trans Med Imag. 2014;33(7):1563\u201372.","journal-title":"IEEE Trans Med Imag"},{"issue":"2","key":"1721_CR3","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1097\/RLU.0000000000001037","volume":"41","author":"KA Frey","year":"2016","unstructured":"Frey KA, Lodge MA, Meltzer CC, Peller PJ, Wong TZ, Hess CP, et al. ACR-ASNR practice parameter for brain PET\/CT imaging dementia. Clin Nucl Med. 2016;41(2):118\u201325.","journal-title":"Clin Nucl Med"},{"issue":"5","key":"1721_CR4","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1109\/42.774167","volume":"18","author":"J Nuyts","year":"1999","unstructured":"Nuyts J, et al. Simultaneous maximum a posteriori reconstruction of attenuation and activity distributions from emission sinograms. IEEE Trans Med Imag. 1999;18(5):393\u2013403.","journal-title":"IEEE Trans Med Imag"},{"issue":"2","key":"1721_CR5","doi-asserted-by":"publisher","first-page":"807","DOI":"10.1118\/1.4938264","volume":"43","author":"Y Berkera","year":"2016","unstructured":"Berkera Y, Li Y. Attenuation correction in emission tomography using the emission data\u2014A review. Med Phys. 2016;43(2):807\u201332.","journal-title":"Med Phys"},{"key":"1721_CR6","doi-asserted-by":"crossref","unstructured":"Kobayashi T, Kitamura K. A solution for scaling problem in joint estimation of activity and attenuation. In: IEEE NSS&MIC Conf. Rec. 2017.","DOI":"10.1109\/NSSMIC.2017.8532856"},{"key":"1721_CR7","doi-asserted-by":"publisher","first-page":"235037","DOI":"10.1088\/1361-6560\/ab8d75","volume":"65","author":"Y Li","year":"2020","unstructured":"Li Y, Matej S, Karp JS. Practical joint reconstruction of activity and attenuation with autonomous scaling for time-of-flight PET. Phys Med Biol. 2020;65:235037.","journal-title":"Phys Med Biol"},{"issue":"4","key":"1721_CR8","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1109\/42.363108","volume":"13","author":"HM Hudson","year":"1994","unstructured":"Hudson HM, Larkin RS. Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imaging. 1994;13(4):601\u20139.","journal-title":"IEEE Trans Med Imaging"},{"key":"1721_CR9","first-page":"255","volume":"1996","author":"CC Watson","year":"1996","unstructured":"Watson CC, Newport D, Casey ME. A single scatter simulation technique for scatter correction in 3D PET. Three-dimensional image reconstruction in radiology and nuclear medicine. IEEE Trans Med Imaging. 1996;1996:255\u201368.","journal-title":"IEEE Trans Med Imaging"},{"key":"1721_CR10","unstructured":"Nakayama T, Kudo H. Derivation and implementation of ordered-subsets algorithms for list-mode PET data. In: IEEE NSS&MIC Conf. Rec. 2005."},{"key":"1721_CR11","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1007\/s12149-012-0655-7","volume":"27","author":"H Iida","year":"2013","unstructured":"Iida H, Hori Y, Ishida K, Imabayashi E, Matsuda H, Takahashi M, et al. Three-dimensional brain phantom containing bone and grey matter structures with a realistic head contour. Ann Nucl Med. 2013;27:25\u201336.","journal-title":"Ann Nucl Med"}],"container-title":["Annals of Nuclear Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12149-022-01721-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12149-022-01721-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12149-022-01721-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,3,21]],"date-time":"2022-03-21T17:17:41Z","timestamp":1647883061000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12149-022-01721-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,9]]},"references-count":11,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2022,4]]}},"alternative-id":["1721"],"URL":"https:\/\/doi.org\/10.1007\/s12149-022-01721-z","relation":{},"ISSN":["0914-7187","1864-6433"],"issn-type":[{"value":"0914-7187","type":"print"},{"value":"1864-6433","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,2,9]]},"assertion":[{"value":"16 September 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 January 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 February 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}