{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T21:03:00Z","timestamp":1784667780007,"version":"3.55.0"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2026,5,9]],"date-time":"2026-05-09T00:00:00Z","timestamp":1778284800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,5,9]],"date-time":"2026-05-09T00:00:00Z","timestamp":1778284800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100019084","name":"Kobe University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100019084","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ann Nucl Med"],"published-print":{"date-parts":[[2026,8]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>In positron emission tomography (PET)\/magnetic resonance imaging (MRI), attenuation correction (AC) for PET of the head is achieved by MRI data to generate pseudo-computed tomography (CT) images. However, for the torso, AC becomes more challenging due to the complexity of separating bone components. Additionally, generating accurate MRI-based CT using deep learning poses significant difficulties for the chest, primarily because perfectly paired MRI and CT training data are hard to obtain owing to respiratory motion and body movements. We previously demonstrated that MRI-to-CT conversion can be achieved without deformation, even using unsupervised learning for zero echo time (ZTE) MRI and CT data from different individuals. Building on this foundation, our study aims to apply this approach to AC in chest PET\/MRI and assess their quantitative accuracy, reproducibility, and external validity.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      The datasets used included (1) training dataset (unpaired ZTE MRI and CT of PET\/CT,\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u2009360 and 500, respectively); (2) test dataset (paired PET\/MRI and PET\/CT,\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200925 and 25, respectively); (3) repeatability assessment dataset (repeated PET\/MRI,\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200915\u2009\u00d7\u20092 scans for the same patient); and (4) external validation dataset (paired MRI component of PET\/MRI and CT,\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200930 and 30, respectively, acquired at another institution). Unpaired training data were used to train the deep learning model of pseudo-CT generation from ZTE. The accuracy, repeatability, and reproducibility of the PET\/MRI scans using ZTE- and deep learning-based AC (MRAC\n                      <jats:sub>ZTE<\/jats:sub>\n                      ) were evaluated based on the similarity of the histograms and the mean standardized uptake value (SUVmean) of physiological background of bone and liver.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The histogram correlation coefficients between MRAC\n                      <jats:sub>ZTE<\/jats:sub>\n                      and the AC map based on the CT (CTAC) for the spine were significantly higher than those between conventional AC (MRAC\n                      <jats:sub>Dixon<\/jats:sub>\n                      ) and CTAC. Additionally, bone SUVmean obtained using MRAC\n                      <jats:sub>ZTE<\/jats:sub>\n                      showed reduced bias relative to CTAC compared with MRAC\n                      <jats:sub>Dixon<\/jats:sub>\n                      . This method proved to be reproducible on each patient level and robust against external validation.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Unsupervised learning with unpaired ZTE and CT data enabled pseudo-CT generation with bone components that closely matched CT-based attenuation maps. Integration into MR-based attenuation correction resulted in stable physiological uptake measurements in chest PET\/MRI, supporting the feasibility of this approach.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s12149-026-02213-0","type":"journal-article","created":{"date-parts":[[2026,5,9]],"date-time":"2026-05-09T09:39:11Z","timestamp":1778319551000},"page":"961-970","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Zero-TE MRI-based attenuation correction for bone components on chest [18F] FDG PET\/MRI: accuracy, repeatability, and external validation of an unsupervised deep learning approach using unpaired PET\/CT data"],"prefix":"10.1007","volume":"40","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4846-5662","authenticated-orcid":false,"given":"Munenobu","family":"Nogami","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9684-4632","authenticated-orcid":false,"given":"Hidetoshi","family":"Matsuo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mizuho","family":"Nishio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Feibi","family":"Zeng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Junko Inoue","family":"Inukai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miho","family":"Tachibana","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Florian","family":"Wiesinger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sandeep","family":"Kaushik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takako","family":"Kurimoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kazuhiro","family":"Kubo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin W.","family":"Huellner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7046-3383","authenticated-orcid":false,"given":"Hidehiko","family":"Okazawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takamichi","family":"Murakami","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,5,9]]},"reference":[{"issue":"Suppl 1","key":"2213_CR1","doi-asserted-by":"publisher","first-page":"S93","DOI":"10.1007\/s00259-008-1007-7","volume":"36","author":"M Hofmann","year":"2009","unstructured":"Hofmann M, Pichler B, Scholkopf B, Beyer T. Towards quantitative PET\/MRI: a review of MR-based attenuation correction techniques. Eur J Nucl Med Mol Imaging. 2009;36(Suppl 1):S93\u2013104.","journal-title":"Eur J Nucl Med Mol Imaging"},{"issue":"2","key":"2213_CR2","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1007\/s11307-014-0777-5","volume":"17","author":"H Arabi","year":"2015","unstructured":"Arabi H, Rager O, Alem A, Varoquaux A, Becker M, Zaidi H. Clinical assessment of MR-guided 3-class and 4-class attenuation correction in PET\/MR. Mol Imaging Biol. 2015;17(2):264\u201376.","journal-title":"Mol Imaging Biol"},{"issue":"7","key":"2213_CR3","doi-asserted-by":"publisher","first-page":"922","DOI":"10.1007\/s00259-002-0796-3","volume":"29","author":"C Burger","year":"2002","unstructured":"Burger C, Goerres G, Schoenes S, Buck A, Lonn AH, Von Schulthess GK. PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients. Eur J Nucl Med Mol Imaging. 2002;29(7):922\u20137.","journal-title":"Eur J Nucl Med Mol Imaging"},{"issue":"8","key":"2213_CR4","doi-asserted-by":"publisher","first-page":"1574","DOI":"10.1007\/s00259-014-2751-5","volume":"41","author":"D Izquierdo-Garcia","year":"2014","unstructured":"Izquierdo-Garcia D, Sawiak SJ, Knesaurek K, Narula J, Fuster V, Machac J, et al. Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET\/MR imaging. Eur J Nucl Med Mol Imaging. 2014;41(8):1574\u201384.","journal-title":"Eur J Nucl Med Mol Imaging"},{"issue":"9","key":"2213_CR5","doi-asserted-by":"publisher","first-page":"4995","DOI":"10.1007\/s00330-020-06848-z","volume":"30","author":"F Zeng","year":"2020","unstructured":"Zeng F, Nogami M, Ueno YR, Kanda T, Sofue K, Kubo K, et al. Diagnostic performance of zero-TE lung MR imaging in FDG PET\/MRI for pulmonary malignancies. Eur Radiol. 2020;30(9):4995\u20135003.","journal-title":"Eur Radiol"},{"issue":"4","key":"2213_CR6","doi-asserted-by":"publisher","first-page":"1440","DOI":"10.1002\/mrm.27134","volume":"80","author":"F Wiesinger","year":"2018","unstructured":"Wiesinger F, Bylund M, Yang J, Kaushik S, Shanbhag D, Ahn S, et al. Zero TE-based pseudo-CT image conversion in the head and its application in PET\/MR attenuation correction and MR-guided radiation therapy planning. Magn Reson Med. 2018;80(4):1440\u201351.","journal-title":"Magn Reson Med"},{"issue":"12","key":"2213_CR7","doi-asserted-by":"publisher","first-page":"1927","DOI":"10.2967\/jnumed.116.175398","volume":"57","author":"T Sekine","year":"2016","unstructured":"Sekine T, Ter Voert EE, Warnock G, Buck A, Huellner M, Veit-Haibach P, et al. Clinical Evaluation of Zero-Echo-Time Attenuation Correction for Brain 18F-FDG PET\/MRI: Comparison with Atlas Attenuation Correction. J Nucl Med. 2016;57(12):1927\u201332.","journal-title":"J Nucl Med"},{"issue":"1","key":"2213_CR8","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1002\/mrm.25545","volume":"75","author":"F Wiesinger","year":"2016","unstructured":"Wiesinger F, Sacolick LI, Menini A, Kaushik SS, Ahn S, Veit-Haibach P, et al. Zero TE MR bone imaging in the head. Magn Reson Med. 2016;75(1):107\u201314.","journal-title":"Magn Reson Med"},{"issue":"3","key":"2213_CR9","doi-asserted-by":"publisher","first-page":"417","DOI":"10.2967\/jnumed.114.149997","volume":"56","author":"G Delso","year":"2015","unstructured":"Delso G, Wiesinger F, Sacolick LI, Kaushik SS, Shanbhag DD, Hullner M, et al. Clinical evaluation of zero-echo-time MR imaging for the segmentation of the skull. J Nucl Med. 2015;56(3):417\u201322.","journal-title":"J Nucl Med"},{"issue":"5","key":"2213_CR10","doi-asserted-by":"publisher","first-page":"1398","DOI":"10.1148\/rg.220029","volume":"42","author":"U Aydingoz","year":"2022","unstructured":"Aydingoz U, Yildiz AE, Ergen FB. Zero Echo Time Musculoskeletal MRI: Technique, Optimization, Applications, and Pitfalls. Radiographics. 2022;42(5):1398\u2013414.","journal-title":"Radiographics"},{"issue":"5","key":"2213_CR11","doi-asserted-by":"publisher","first-page":"852","DOI":"10.2967\/jnumed.117.198051","volume":"59","author":"AP Leynes","year":"2018","unstructured":"Leynes AP, Yang J, Wiesinger F, Kaushik SS, Shanbhag DD, Seo Y, et al. Zero-Echo-Time and Dixon Deep Pseudo-CT (ZeDD CT): Direct Generation of Pseudo-CT Images for Pelvic PET\/MRI Attenuation Correction Using Deep Convolutional Neural Networks with Multiparametric MRI. J Nucl Med. 2018;59(5):852\u20138.","journal-title":"J Nucl Med"},{"issue":"1","key":"2213_CR12","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1007\/s10334-012-0344-5","volume":"26","author":"P Veit-Haibach","year":"2013","unstructured":"Veit-Haibach P, Kuhn FP, Wiesinger F, Delso G, von Schulthess G. PET-MR imaging using a tri-modality PET\/CT-MR system with a dedicated shuttle in clinical routine. MAGMA. 2013;26(1):25\u201335.","journal-title":"MAGMA"},{"key":"2213_CR13","doi-asserted-by":"publisher","first-page":"232","DOI":"10.1016\/j.clinimag.2017.01.003","volume":"42","author":"T Sekine","year":"2017","unstructured":"Sekine T, de Galiza Barbosa F, Kuhn FP, Burger IA, Stolzmann P, Huber GF, et al. PET\u2009+\u2009MR versus PET\/CT in the initial staging of head and neck cancer, using a trimodality PET\/CT\u2009+\u2009MR system. Clin Imaging. 2017;42:232\u20139.","journal-title":"Clin Imaging"},{"issue":"1","key":"2213_CR14","doi-asserted-by":"publisher","first-page":"11090","DOI":"10.1038\/s41598-022-14677-x","volume":"12","author":"H Matsuo","year":"2022","unstructured":"Matsuo H, Nishio M, Nogami M, Zeng F, Kurimoto T, Kaushik S, et al. Unsupervised-learning-based method for chest MRI-CT transformation using structure constrained unsupervised generative attention networks. Sci Rep. 2022;12(1):11090.","journal-title":"Sci Rep"},{"issue":"7","key":"2213_CR15","doi-asserted-by":"publisher","first-page":"1423","DOI":"10.1016\/j.media.2012.05.008","volume":"16","author":"MP Heinrich","year":"2012","unstructured":"Heinrich MP, Jenkinson M, Bhushan M, Matin T, Gleeson FV, Brady SM, et al. MIND: modality independent neighbourhood descriptor for multi-modal deformable registration. Med Image Anal. 2012;16(7):1423\u201335.","journal-title":"Med Image Anal"},{"key":"2213_CR16","doi-asserted-by":"publisher","unstructured":"Kim J, Kim M, Kang H, Lee K. U-GAT-IT: Unsupervised Generative Attentional Networks with Adaptive Layer-Instance Normalization for Image-to-Image Translation. ArXiv. 2019;abs\/1907.10830. https:\/\/doi.org\/10.48550\/arXiv.1907.10830","DOI":"10.48550\/arXiv.1907.10830"},{"issue":"1","key":"2213_CR17","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1002\/mrm.27928","volume":"83","author":"M Engstrom","year":"2020","unstructured":"Engstrom M, McKinnon G, Cozzini C, Wiesinger F. In-phase zero TE musculoskeletal imaging. Magn Reson Med. 2020;83(1):195\u2013202.","journal-title":"Magn Reson Med"},{"issue":"6","key":"2213_CR18","doi-asserted-by":"publisher","first-page":"1310","DOI":"10.1109\/TMI.2010.2046908","volume":"29","author":"NJ Tustison","year":"2010","unstructured":"Tustison NJ, Avants BB, Cook PA, Zheng Y, Egan A, Yushkevich PA, et al. N4ITK: improved N3 bias correction. IEEE Trans Med Imaging. 2010;29(6):1310\u201320.","journal-title":"IEEE Trans Med Imaging"},{"issue":"5","key":"2213_CR19","doi-asserted-by":"publisher","first-page":"812","DOI":"10.2967\/jnumed.109.065425","volume":"51","author":"V Keereman","year":"2010","unstructured":"Keereman V, Fierens Y, Broux T, De Deene Y, Lonneux M, Vandenberghe S. MRI-based attenuation correction for PET\/MRI using ultrashort echo time sequences. J Nucl Med. 2010;51(5):812\u20138.","journal-title":"J Nucl Med"},{"issue":"2","key":"2213_CR20","doi-asserted-by":"publisher","first-page":"676","DOI":"10.1148\/radiol.2017170700","volume":"286","author":"F Liu","year":"2018","unstructured":"Liu F, Jang H, Kijowski R, Bradshaw T, McMillan AB. Deep Learning MR Imaging-based Attenuation Correction for PET\/MR Imaging. Radiology. 2018;286(2):676\u201384.","journal-title":"Radiology"},{"key":"2213_CR21","doi-asserted-by":"publisher","first-page":"101718","DOI":"10.1016\/j.media.2020.101718","volume":"64","author":"H Arabi","year":"2020","unstructured":"Arabi H, Zaidi H. Deep learning-guided estimation of attenuation correction factors from time-of-flight PET emission data. Med Image Anal. 2020;64:101718.","journal-title":"Med Image Anal"},{"issue":"4","key":"2213_CR22","doi-asserted-by":"publisher","first-page":"469","DOI":"10.1007\/s11307-013-0716-x","volume":"16","author":"R Boellaard","year":"2014","unstructured":"Boellaard R, Hofman MB, Hoekstra OS, Lammertsma AA. Accurate PET\/MR quantification using time of flight MLAA image reconstruction. Mol Imaging Biol. 2014;16(4):469\u201377.","journal-title":"Mol Imaging Biol"},{"issue":"6","key":"2213_CR23","doi-asserted-by":"publisher","first-page":"877","DOI":"10.2967\/jnumed.115.154807","volume":"56","author":"A Mehranian","year":"2015","unstructured":"Mehranian A, Zaidi H. Clinical Assessment of Emission- and Segmentation-Based MR-Guided Attenuation Correction in Whole-Body Time-of-Flight PET\/MR Imaging. J Nucl Med. 2015;56(6):877\u201383.","journal-title":"J Nucl Med"},{"key":"2213_CR24","doi-asserted-by":"publisher","first-page":"288","DOI":"10.18632\/oncotarget.28583","volume":"15","author":"KC Ma","year":"2024","unstructured":"Ma KC, Mena E, Lindenberg L, Lay NS, Eclarinal P, Citrin DE, et al. Deep learning-based whole-body PSMA PET\/CT attenuation correction utilizing Pix-2-Pix GAN. Oncotarget. 2024;15:288\u2013300.","journal-title":"Oncotarget"},{"issue":"1","key":"2213_CR25","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1186\/s13550-018-0390-8","volume":"8","author":"UJ Muehlematter","year":"2018","unstructured":"Muehlematter UJ, Nagel HW, Becker A, Mueller J, Vokinger KN, de Galiza Barbosa F, et al. Impact of time-of-flight PET on quantification accuracy and lesion detection in simultaneous (18)F-choline PET\/MRI for prostate cancer. EJNMMI Res. 2018;8(1):41.","journal-title":"EJNMMI Res"},{"key":"2213_CR26","doi-asserted-by":"publisher","unstructured":"Omidvari N, Cheng L, Leung EK, Abdelhafez YG, Badawi RD, Ma T et al. Lutetium background radiation in total-body PET-A simulation study on opportunities and challenges in PET attenuation correction. Front Nucl Med. 2022;2:963067. https:\/\/doi.org\/10.3389\/fnume.2022.96306","DOI":"10.3389\/fnume.2022.96306"},{"issue":"4","key":"2213_CR27","doi-asserted-by":"publisher","first-page":"635","DOI":"10.2967\/jnumed.114.148817","volume":"56","author":"A Mehranian","year":"2015","unstructured":"Mehranian A, Zaidi H. Impact of time-of-flight PET on quantification errors in MR imaging-based attenuation correction. J Nucl Med. 2015;56(4):635\u201341.","journal-title":"J Nucl Med"},{"issue":"1","key":"2213_CR28","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1186\/s40658-022-00486-8","volume":"9","author":"S Ahangari","year":"2022","unstructured":"Ahangari S, Beck Olin A, Kinggard Federspiel M, Jakoby B, Andersen TL, Hansen AE, et al. A deep learning-based whole-body solution for PET\/MRI attenuation correction. EJNMMI Phys. 2022;9(1):55.","journal-title":"EJNMMI Phys"},{"issue":"13","key":"2213_CR29","doi-asserted-by":"publisher","first-page":"4490","DOI":"10.1007\/s00259-022-05909-3","volume":"49","author":"H Sari","year":"2022","unstructured":"Sari H, Teimoorisichani M, Mingels C, Alberts I, Panin V, Bharkhada D, et al. Quantitative evaluation of a deep learning-based framework to generate whole-body attenuation maps using LSO background radiation in long axial FOV PET scanners. Eur J Nucl Med Mol Imaging. 2022;49(13):4490\u2013502.","journal-title":"Eur J Nucl Med Mol Imaging"},{"issue":"12","key":"2213_CR30","doi-asserted-by":"publisher","first-page":"125011","DOI":"10.1088\/1361-6560\/aac763","volume":"63","author":"K Gong","year":"2018","unstructured":"Gong K, Yang J, Kim K, El Fakhri G, Seo Y, Li Q. Attenuation correction for brain PET imaging using deep neural network based on Dixon and ZTE MR images. Phys Med Biol. 2018;63(12):125011.","journal-title":"Phys Med Biol"},{"issue":"1","key":"2213_CR31","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1007\/s00259-020-04816-9","volume":"48","author":"A Pozaruk","year":"2021","unstructured":"Pozaruk A, Pawar K, Li S, Carey A, Cheng J, Sudarshan VP, et al. Augmented deep learning model for improved quantitative accuracy of MR-based PET attenuation correction in PSMA PET-MRI prostate imaging. Eur J Nucl Med Mol Imaging. 2021;48(1):9\u201320.","journal-title":"Eur J Nucl Med Mol Imaging"},{"issue":"2","key":"2213_CR32","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1109\/TRPMS.2020.3006844","volume":"5","author":"K Gong","year":"2021","unstructured":"Gong K, Yang J, Larson PEZ, Behr SC, Hope TA, Seo Y, et al. MR-based Attenuation Correction for Brain PET Using 3D Cycle-Consistent Adversarial Network. IEEE Trans Radiat Plasma Med Sci. 2021;5(2):185\u201392.","journal-title":"IEEE Trans Radiat Plasma Med Sci"},{"issue":"8","key":"2213_CR33","doi-asserted-by":"publisher","first-page":"1137","DOI":"10.2967\/jnumed.114.147728","volume":"56","author":"WA Weber","year":"2015","unstructured":"Weber WA, Gatsonis CA, Mozley PD, Hanna LG, Shields AF, Aberle DR, et al. Repeatability of 18F-FDG PET\/CT in Advanced Non-Small Cell Lung Cancer: Prospective Assessment in 2 Multicenter Trials. J Nucl Med. 2015;56(8):1137\u201343.","journal-title":"J Nucl Med"},{"key":"2213_CR34","doi-asserted-by":"publisher","unstructured":"Nakamoto Y, Kitajima K, Toriihara A, Nakajo M, Hirata K. Recent topics of the clinical utility of PET\/MRI in oncology and neuroscience. Ann Nucl Med. 2022;36(9):798-803. https:\/\/doi.org\/10.1007\/s12149-022-01780-2","DOI":"10.1007\/s12149-022-01780-2"}],"container-title":["Annals of Nuclear Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12149-026-02213-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12149-026-02213-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12149-026-02213-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T20:32:13Z","timestamp":1784665933000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12149-026-02213-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,9]]},"references-count":34,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2026,8]]}},"alternative-id":["2213"],"URL":"https:\/\/doi.org\/10.1007\/s12149-026-02213-0","relation":{},"ISSN":["0914-7187","1864-6433"],"issn-type":[{"value":"0914-7187","type":"print"},{"value":"1864-6433","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,9]]},"assertion":[{"value":"24 September 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 April 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 May 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}