{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T07:15:43Z","timestamp":1788419743562,"version":"build-2803163510"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T00:00:00Z","timestamp":1788393600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T00:00:00Z","timestamp":1788393600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ann Nucl Med"],"DOI":"10.1007\/s12149-026-02279-w","type":"journal-article","created":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T06:35:06Z","timestamp":1788417306000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Comparison of high-purity germanium detectors and gamma-ray water monitors in radioactive wastewater management for targeted radionuclide therapy"],"prefix":"10.1007","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1518-831X","authenticated-orcid":false,"given":"Noriaki","family":"Miyaji","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuma","family":"Ihara","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rintaro","family":"Sato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shigenori","family":"Yabe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katsuyuki","family":"Kikori","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naochika","family":"Akiya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kaito","family":"Wachi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akemi","family":"Minami","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kosuke","family":"Yamashita","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tensho","family":"Yamao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takashi","family":"Ohba","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Koki","family":"Hasegawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenta","family":"Miwa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Noboru","family":"Oriuchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,3]]},"reference":[{"issue":"Suppl 1","key":"2279_CR1","doi-asserted-by":"publisher","first-page":"144s","DOI":"10.2967\/jnmt.125.271067","volume":"53","author":"D Beyder","year":"2025","unstructured":"Beyder D. Theranostics finances and coding of today and a look forward. J Nucl Med Technol. 2025;53(Suppl 1):144s-s149.","journal-title":"J Nucl Med Technol"},{"issue":"3","key":"2279_CR2","doi-asserted-by":"publisher","first-page":"e146","DOI":"10.1016\/S1470-2045(19)30821-6","volume":"21","author":"K Herrmann","year":"2020","unstructured":"Herrmann K, Schwaiger M, Lewis JS, Solomon SB, McNeil BJ, Baumann M, et al. Radiotheranostics: a roadmap for future development. Lancet Oncol. 2020;21(3):e146\u201356.","journal-title":"Lancet Oncol"},{"issue":"Pt 1","key":"2279_CR3","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1016\/j.jenvrad.2016.04.002","volume":"166","author":"F Sudbrock","year":"2017","unstructured":"Sudbrock F, Schom\u00e4cker K, Drzezga A. The effectiveness of wastewater treatment in nuclear medicine: performance data and radioecological considerations. J Environ Radioact. 2017;166(Pt 1):202\u20137.","journal-title":"J Environ Radioact"},{"issue":"2","key":"2279_CR4","first-page":"109","volume":"41","author":"K Shizukuishi","year":"2004","unstructured":"Shizukuishi K, Watanabe H, Narita H, Kanaya S, Kobayashi K, Yamamoto T, et al. A questionnaire about radiation safety management of the draining-water system at nuclear medicine facilities. Kaku Igaku. 2004;41(2):109\u201321.","journal-title":"Kaku Igaku"},{"issue":"1","key":"2279_CR5","doi-asserted-by":"publisher","first-page":"1","DOI":"10.12950\/rsm2002.5.1","volume":"5","author":"K Inada","year":"2006","unstructured":"Inada K, Nakashima S, Matsushima A, Saito T, Iwatani K, Shizuma K. Durability of reagents for the purification plant of radioactive wastewater. Radiation Safety Management. 2006;5(1):1\u20134.","journal-title":"Radiation Safety Management"},{"issue":"1","key":"2279_CR6","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1051\/radiopro\/2024042","volume":"60","author":"G Yunwen","year":"2025","unstructured":"Yunwen G. Determination of decay tank capacity and minimum storage time for liquid radioactive effluent based on environmental requirements. Radioprotection. 2025;60(1):91\u20138.","journal-title":"Radioprotection"},{"issue":"1","key":"2279_CR7","first-page":"59","volume":"62","author":"T Mizowaki","year":"2025","unstructured":"Mizowaki T, Hosono M, Uemura H, Eto M, Oya M, Miyake H, et al. Evaluation of appropriate treatment infrastructure for radionuclide therapy through discrete event simulation. Kaku Igaku. 2025;62(1):59\u201370.","journal-title":"Kaku Igaku"},{"issue":"11","key":"2279_CR8","doi-asserted-by":"publisher","first-page":"2168","DOI":"10.1007\/s10147-025-02858-3","volume":"30","author":"K Suzuki","year":"2025","unstructured":"Suzuki K, Miyake H, Inaki A, Takano S, Kuboki Y, Mizowaki T, et al. Policy recommendations for promoting nuclear medicine therapy in Japan 2025, from the working group for promoting nuclear medicine therapy of the Japan society of clinical oncology. Int J Clin Oncol. 2025;30(11):2168\u201377.","journal-title":"Int J Clin Oncol"},{"key":"2279_CR9","doi-asserted-by":"publisher","DOI":"10.1007\/s12149-026-02247-4","author":"R Sato","year":"2026","unstructured":"Sato R, Miyaji N, Hasegawa K, Ihara Y, Yabe S, Kikori K, et al. Adsorption treatment of (177)Lu radioactive wastewater with (177m)Lu impurity: batch versus column methods. Ann Nucl Med. 2026. https:\/\/doi.org\/10.1007\/s12149-026-02247-4.","journal-title":"Ann Nucl Med"},{"key":"2279_CR10","doi-asserted-by":"publisher","DOI":"10.1016\/j.radphyschem.2022.110325","volume":"199","author":"S Maeng","year":"2022","unstructured":"Maeng S, Lee SH, Park SJ, Choi WC. Detection efficiency evaluation for low energy of a NaI(Tl) scintillation detector. Radiat Phys Chem. 2022;199:110325.","journal-title":"Radiat Phys Chem"},{"issue":"9","key":"2279_CR11","doi-asserted-by":"publisher","DOI":"10.1016\/j.net.2025.103656","volume":"57","author":"D Lee","year":"2025","unstructured":"Lee D, Maeng S, Lee SH. Optimization of a water-intake system for monitoring radionuclides in aquatic environments. Nucl Eng Technol. 2025;57(9):103656.","journal-title":"Nucl Eng Technol"},{"issue":"3","key":"2279_CR12","doi-asserted-by":"publisher","first-page":"2171","DOI":"10.1007\/s10967-024-09648-7","volume":"334","author":"N Channappa","year":"2025","unstructured":"Channappa N, Kerur BR. Standardization of gamma-ray spectrometry using the NaI (TI) scintillation detector. J Radioanal Nucl Chem. 2025;334(3):2171\u20136.","journal-title":"J Radioanal Nucl Chem"},{"issue":"2","key":"2279_CR13","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1016\/j.apradiso.2009.10.041","volume":"68","author":"A Ceccatelli","year":"2010","unstructured":"Ceccatelli A, Campanella F, Ciofetta G, Marracino FM, Cannat\u00e0 V. A new experimental procedure for determination of photoelectric efficiency of a NaI(Tl) detector used for nuclear medicine liquid waste monitoring with traceability to a reference standard radionuclide calibrator. Appl Radiat Isot. 2010;68(2):275\u20139.","journal-title":"Appl Radiat Isot"},{"issue":"1","key":"2279_CR14","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1016\/j.apradiso.2003.10.006","volume":"60","author":"A Perez-Andujar","year":"2004","unstructured":"Perez-Andujar A, Pibida L. Performance of CdTe, HPGe and NaI(Tl) detectors for radioactivity measurements. Appl Radiat Isot. 2004;60(1):41\u20137.","journal-title":"Appl Radiat Isot"},{"issue":"10","key":"2279_CR15","doi-asserted-by":"publisher","first-page":"P10027","DOI":"10.1088\/1748-0221\/8\/10\/P10027","volume":"8","author":"D Demir","year":"2013","unstructured":"Demir D, Ero\u011flu M, Tur\u015fucu A. Studying of characteristics of the HPGe detector for radioactivity measurements. J Instrum. 2013;8(10):P10027.","journal-title":"J Instrum"},{"key":"2279_CR16","doi-asserted-by":"publisher","DOI":"10.1016\/j.apradiso.2024.111234","volume":"206","author":"G Eleftheriou","year":"2024","unstructured":"Eleftheriou G, Tsabaris C, Androulakaki EG, Pappa FK, Patiris DL. High resolution gamma-ray spectrometry for routine measurements of environmental samples. Appl Radiat Isot. 2024;206:111234.","journal-title":"Appl Radiat Isot"},{"key":"2279_CR17","doi-asserted-by":"publisher","first-page":"818","DOI":"10.1016\/j.scitotenv.2019.01.349","volume":"663","author":"D Mulas","year":"2019","unstructured":"Mulas D, Camacho A, Garbayo A, Devesa R, Duch MA. Medically-derived radionuclides levels in seven heterogeneous urban wastewater treatment plants: the role of operating conditions and catchment area. Sci Total Environ. 2019;663:818\u201329.","journal-title":"Sci Total Environ"},{"key":"2279_CR18","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6498\/ace6ad","author":"TD Puspita","year":"2023","unstructured":"Puspita TD, Moersidik SS, Pratama MA. Radiological study of a wastewater treatment plant associated with radioiodine therapy at a hospital in West Java, Indonesia. J Radiol Prot. 2023. https:\/\/doi.org\/10.1088\/1361-6498\/ace6ad.","journal-title":"J Radiol Prot"},{"issue":"1","key":"2279_CR19","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1186\/s40658-023-00524-z","volume":"10","author":"S Prevot","year":"2023","unstructured":"Prevot S, Dyga\u00ef-Cochet I, Riedinger JM, Vrigneaud JM, Quermonne M, Gallet M, et al. Dealing with dry waste disposal issues associated with (177m)Lu impurities: a long-term challenge for nuclear medicine departments. EJNMMI Phys. 2023;10(1):3.","journal-title":"EJNMMI Phys"},{"issue":"13","key":"2279_CR20","doi-asserted-by":"publisher","first-page":"686","DOI":"10.1002\/jlcr.3099","volume":"56","author":"MR Davarpanah","year":"2013","unstructured":"Davarpanah MR, Attar Nosrati S, Khoshhosn HA, Fazlali M, Kazemi Boudani M. Establishment of a fast and high yield method for routine production of [(131)I]MIBG and investigation of its radiochemical stability for diagnosis and treatment uses. J Labelled Comp Radiopharm. 2013;56(13):686\u20138.","journal-title":"J Labelled Comp Radiopharm"},{"key":"2279_CR21","doi-asserted-by":"publisher","DOI":"10.1016\/j.jchromb.2021.122605","volume":"1171","author":"L van Andel","year":"2021","unstructured":"van Andel L, Aalbersberg EA, Geluk-Jonker MM, Stokkel MPM, Beijnen JH, Hendrikx J. The development and validation of a high performance liquid chromatography method to determine the radiochemical purity of [(177)Lu]Lu-HA-DOTA-TATE in pharmaceutical preparations. J Chromatogr B Analyt Technol Biomed Life Sci. 2021;1171:122605.","journal-title":"J Chromatogr B Analyt Technol Biomed Life Sci"},{"issue":"2","key":"2279_CR22","doi-asserted-by":"publisher","DOI":"10.1140\/epjp\/s13360-025-06048-y","volume":"140","author":"Z Saeidi","year":"2025","unstructured":"Saeidi Z, Afarideh H, Ghergherehchi M. Enhanced gamma-ray spectrum transformation: NaI(Tl) scintillator to HPGe semiconductor via machine learning. Eur Phys J Plus. 2025;140(2):113.","journal-title":"Eur Phys J Plus"},{"issue":"18","key":"2279_CR23","doi-asserted-by":"publisher","first-page":"2233","DOI":"10.1093\/rpd\/ncad258","volume":"199","author":"Y Omori","year":"2023","unstructured":"Omori Y, Sorimachi A, Hosoda M, Sahoo SK, Kavasi N, Kurihara O, et al. Improvement of spectral analysis using a NaI(Tl) scintillation spectrometer to evaluate ambient gamma dose rates from primordial radionuclides. Radiat Prot Dosimetry. 2023;199(18):2233\u20137.","journal-title":"Radiat Prot Dosimetry"},{"issue":"18","key":"2279_CR24","doi-asserted-by":"publisher","first-page":"5877","DOI":"10.1088\/0031-9155\/56\/18\/007","volume":"56","author":"LC Johnson","year":"2011","unstructured":"Johnson LC, Campbell DL, Hull EL, Peterson TE. Characterization of a high-purity germanium detector for small-animal SPECT. Phys Med Biol. 2011;56(18):5877\u201388.","journal-title":"Phys Med Biol"},{"issue":"2","key":"2279_CR25","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1080\/00223131.2023.2278598","volume":"61","author":"V Semkova","year":"2024","unstructured":"Semkova V, Otuka N, Plompen AJM. Characterization of a HPGe detector response for activation cross section measurements: regression method versus monte carlo method. J Nucl Sci Technol. 2024;61(2):151\u201360.","journal-title":"J Nucl Sci Technol"},{"issue":"4","key":"2279_CR26","first-page":"7","volume":"4","author":"GR Pansare","year":"2016","unstructured":"Pansare GR, Ansari SJ, Kamthe UR. Measurement of energy resolution and detection efficiency of NaI(Tl) scintillation gamma ray spectrometer for different gamma ray energies. Res J Mater Sci. 2016;4(4):7\u201312.","journal-title":"Res J Mater Sci"},{"key":"2279_CR27","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1016\/j.jenvrad.2016.04.008","volume":"158\u2013159","author":"G Giubrone","year":"2016","unstructured":"Giubrone G, Ortiz J, Gallardo S, Martorell S, Bas MC. Calculation of coincidence summing correction factors for an HPGe detector using GEANT4. J Environ Radioact. 2016;158\u2013159:114\u20138.","journal-title":"J Environ Radioact"},{"key":"2279_CR28","doi-asserted-by":"publisher","DOI":"10.1016\/j.apradiso.2022.110421","volume":"189","author":"J Knezevic","year":"2022","unstructured":"Knezevic J, Mrdja D, Hansman J, Bikit K, Forkapic S, Bikit I, et al. Corrections of HPGe detector efficiency curve due to true coincidence summing by program EFFTRAN and by Monte Carlo simulations. Appl Radiat Isot. 2022;189:110421.","journal-title":"Appl Radiat Isot"}],"container-title":["Annals of Nuclear Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12149-026-02279-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12149-026-02279-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12149-026-02279-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T06:35:07Z","timestamp":1788417307000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12149-026-02279-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,3]]},"references-count":28,"alternative-id":["2279"],"URL":"https:\/\/doi.org\/10.1007\/s12149-026-02279-w","relation":{},"ISSN":["0914-7187","1864-6433"],"issn-type":[{"value":"0914-7187","type":"print"},{"value":"1864-6433","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,3]]},"assertion":[{"value":"12 June 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 August 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 September 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare that they have no competing interests.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}]}}