{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,23]],"date-time":"2026-08-23T18:47:10Z","timestamp":1787510830519,"version":"build-2736575974"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2019,11,7]],"date-time":"2019-11-07T00:00:00Z","timestamp":1573084800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,11,7]],"date-time":"2019-11-07T00:00:00Z","timestamp":1573084800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Curr Rev Musculoskelet Med"],"published-print":{"date-parts":[[2019,12]]},"DOI":"10.1007\/s12178-019-09577-z","type":"journal-article","created":{"date-parts":[[2019,11,7]],"date-time":"2019-11-07T03:03:26Z","timestamp":1573095806000},"page":"415-424","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":22,"title":["Computer Navigation in Minimally Invasive Spine Surgery"],"prefix":"10.1007","volume":"12","author":[{"given":"Jonathan N.","family":"Sembrano","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sharon C.","family":"Yson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeffrey J.","family":"Theismann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,11,7]]},"reference":[{"issue":"20","key":"9577_CR1","doi-asserted-by":"publisher","first-page":"2637","DOI":"10.1097\/00007632-200010150-00016","volume":"25","author":"YR Rampersaud","year":"2000","unstructured":"Rampersaud YR, Foley KT, Shen AC, Williams S, Solomito M. Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion. Spine (Phila Pa 1976). 2000;25(20):2637\u201345.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"7","key":"9577_CR2","doi-asserted-by":"publisher","first-page":"468","DOI":"10.1097\/BSD.0b013e31819877c8","volume":"22","author":"H Nakashima","year":"2009","unstructured":"Nakashima H, Sato K, Ando T, Inoh H, Nakamura H. Comparison of the percutaneous screw placement precision of isocentric C-arm 3-dimensional fluoroscopy-navigated pedicle screw implantation and conventional fluoroscopy method with minimally invasive surgery. J Spinal Disord Tech. 2009;22(7):468\u201372.","journal-title":"J Spinal Disord Tech"},{"issue":"24","key":"9577_CR3","doi-asserted-by":"publisher","first-page":"2055","DOI":"10.1097\/BRS.0b013e31825c05cd","volume":"37","author":"BP Yang","year":"2012","unstructured":"Yang BP, Wahl MM, Idler CS. Percutaneous lumbar pedicle screw placement aided by computer-assisted fluoroscopy-based navigation: perioperative results of a prospective, comparative, multicenter study. Spine (Phila Pa 1976). 2012;37(24):2055\u201360.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"9","key":"9577_CR4","doi-asserted-by":"publisher","first-page":"324","DOI":"10.1097\/BSD.0000000000000152","volume":"28","author":"AC Bourgeois","year":"2015","unstructured":"Bourgeois AC, Faulkner AR, Bradley YC, et al. Improved accuracy of minimally invasive transpedicular screw placement in the lumbar spine with 3-dimensional stereotactic image guidance: a comparative meta-analysis. J Spinal Disord Tech. 2015;28(9):324\u20139.","journal-title":"J Spinal Disord Tech"},{"issue":"6","key":"9577_CR5","doi-asserted-by":"publisher","first-page":"1775","DOI":"10.1007\/s00586-016-4489-1","volume":"25","author":"T Ohba","year":"2016","unstructured":"Ohba T, Ebata S, Fujita K, Sato H, Haro H. Percutaneous pedicle screw placements: accuracy and rates of cranial facet joint violation using conventional fluoroscopy compared with intraoperative three-dimensional computed tomography computer navigation. Eur Spine J. 2016;25(6):1775\u201380.","journal-title":"Eur Spine J"},{"key":"9577_CR6","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1007\/978-3-319-39546-3_42","volume":"124","author":"G Innocenzi","year":"2017","unstructured":"Innocenzi G, Bistazzoni S, D\u2019Ercole M, Cardarelli G, Ricciardi F. Does navigation improve pedicle screw placement accuracy? Comparison between navigated and non-navigated percutaneous and open fixations. Acta Neurochir Suppl. 2017;124:289\u201395.","journal-title":"Acta Neurochir Suppl"},{"key":"9577_CR7","doi-asserted-by":"publisher","first-page":"e410","DOI":"10.1016\/j.wneu.2017.12.080","volume":"111","author":"E Fomekong","year":"2018","unstructured":"Fomekong E, Pierrard J, Raftopoulos C. Comparative cohort study of percutaneous pedicle screw implantation without versus with navigation in patients undergoing surgery for degenerative lumbar disc disease. World Neurosurg. 2018;111:e410\u20137.","journal-title":"World Neurosurg"},{"issue":"1","key":"9577_CR8","doi-asserted-by":"publisher","first-page":"E1","DOI":"10.1097\/BSD.0b013e3181d534b8","volume":"24","author":"M Wood","year":"2011","unstructured":"Wood M, Mannion R. A comparison of CT-based navigation techniques for minimally invasive lumbar pedicle screw placement. J Spinal Disord Tech. 2011;24(1):E1\u20135.","journal-title":"J Spinal Disord Tech"},{"issue":"2","key":"9577_CR9","doi-asserted-by":"publisher","first-page":"e129","DOI":"10.3928\/01477447-20150204-61","volume":"38","author":"ER Santos","year":"2015","unstructured":"Santos ER, Sembrano JN, Yson SC, Polly DW Jr. Comparison of open and percutaneous lumbar pedicle screw revision rate using 3-D image guidance and intraoperative CT. Orthopedics. 2015;38(2):e129\u201334.","journal-title":"Orthopedics."},{"issue":"4","key":"9577_CR10","doi-asserted-by":"publisher","first-page":"E251","DOI":"10.1097\/BRS.0b013e31827ecbf1","volume":"38","author":"SC Yson","year":"2013","unstructured":"Yson SC, Sembrano JN, Sanders PC, Santos ER, Ledonio CG, Polly DW Jr. Comparison of cranial facet joint violation rates between open and percutaneous pedicle screw placement using intraoperative 3-D CT (O-arm) computer navigation. Spine (Phila Pa 1976). 2013;38(4):E251\u20138.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"22","key":"9577_CR11","doi-asserted-by":"crossref","first-page":"3852","DOI":"10.3760\/cma.j.issn.0366-6999.20141860","volume":"127","author":"W Tian","year":"2014","unstructured":"Tian W, Xu Y, Liu B, et al. Lumbar spine superior-level facet joint violations: percutaneous versus open pedicle screw insertion using intraoperative 3-dimensional computer-assisted navigation. Chin Med J. 2014;127(22):3852\u20136.","journal-title":"Chin Med J"},{"issue":"3","key":"9577_CR12","doi-asserted-by":"publisher","first-page":"589","DOI":"10.1007\/s00701-010-0882-4","volume":"153","author":"R von Jako","year":"2011","unstructured":"von Jako R, Finn MA, Yonemura KS, et al. Minimally invasive percutaneous transpedicular screw fixation: increased accuracy and reduced radiation exposure by means of a novel electromagnetic navigation system. Acta Neurochir. 2011;153(3):589\u201396.","journal-title":"Acta Neurochir"},{"issue":"3","key":"9577_CR13","doi-asserted-by":"publisher","first-page":"e3","DOI":"10.3171\/foc.2005.18.3.4","volume":"18","author":"AT Villavicencio","year":"2005","unstructured":"Villavicencio AT, Burneikiene S, Bulsara KR, Thramann JJ. Intraoperative three-dimensional fluoroscopy-based computerized tomography guidance for percutaneous kyphoplasty. Neurosurg Focus. 2005;18(3):e3.","journal-title":"Neurosurg Focus"},{"issue":"12","key":"9577_CR14","doi-asserted-by":"publisher","first-page":"1325","DOI":"10.1097\/BRS.0b013e3181a18529","volume":"34","author":"K Izadpanah","year":"2009","unstructured":"Izadpanah K, Konrad G, Sudkamp NP, Oberst M. Computer navigation in balloon kyphoplasty reduces the intraoperative radiation exposure. Spine (Phila Pa 1976). 2009;34(12):1325\u20139.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"8","key":"9577_CR15","first-page":"987","volume":"122","author":"CT Sun","year":"2009","unstructured":"Sun CT, Zhao LL, Zhang QW, Wen LY, Zhang HC. Navigation techniques assisted kyphoplasty for the treatment of osteoporotic spinal compression fracture. Chin Med J. 2009;122(8):987\u20139.","journal-title":"Chin Med J"},{"issue":"1","key":"9577_CR16","doi-asserted-by":"publisher","first-page":"17","DOI":"10.3928\/01477447-20150105-51","volume":"38","author":"JN Sembrano","year":"2015","unstructured":"Sembrano JN, Yson SC, Polly DW Jr, Ledonio CG, Nuckley DJ, Santos ER. Comparison of nonnavigated and 3-dimensional image-based computer navigated balloon kyphoplasty. Orthopedics. 2015;38(1):17\u201323.","journal-title":"Orthopedics"},{"issue":"4","key":"9577_CR17","doi-asserted-by":"publisher","first-page":"584","DOI":"10.1016\/j.spinee.2006.12.012","volume":"8","author":"CW Kim","year":"2008","unstructured":"Kim CW, Lee YP, Taylor W, Oygar A, Kim WK. Use of navigation-assisted fluoroscopy to decrease radiation exposure during minimally invasive spine surgery. Spine J. 2008;8(4):584\u201390.","journal-title":"Spine J"},{"issue":"22","key":"9577_CR18","first-page":"3947","volume":"125","author":"W Luo","year":"2012","unstructured":"Luo W, Zhang F, Liu T, Du XL, Chen AM, Li F. Minimally invasive transforaminal lumbar interbody fusion aided with computer-assisted spinal navigation system combined with electromyography monitoring. Chin Med J. 2012;125(22):3947\u201351.","journal-title":"Chin Med J"},{"issue":"6","key":"9577_CR19","doi-asserted-by":"publisher","first-page":"300","DOI":"10.3109\/10929088.2012.728625","volume":"17","author":"JY Cho","year":"2012","unstructured":"Cho JY, Chan CK, Lee SH, Lee HY. The accuracy of 3D image navigation with a cutaneously fixed dynamic reference frame in minimally invasive transforaminal lumbar interbody fusion. Comput Aided Surg. 2012;17(6):300\u20139.","journal-title":"Comput Aided Surg"},{"key":"9577_CR20","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1016\/j.wneu.2017.06.174","volume":"106","author":"Y Zhang","year":"2017","unstructured":"Zhang Y, Xu C, Zhou Y, Huang B. Minimally invasive computer navigation-assisted endoscopic transforaminal interbody fusion with bilateral decompression via a unilateral approach: initial clinical experience at one-year follow-up. World Neurosurg. 2017;106:291\u20139.","journal-title":"World Neurosurg"},{"issue":"6","key":"9577_CR21","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1097\/BSD.0000000000000165","volume":"30","author":"W Tian","year":"2017","unstructured":"Tian W, Xu YF, Liu B, et al. Computer-assisted minimally invasive transforaminal lumbar interbody fusion may be better than open surgery for treating degenerative lumbar disease. Clin Spine Surg. 2017;30(6):237\u201342.","journal-title":"Clin Spine Surg"},{"issue":"27","key":"9577_CR22","doi-asserted-by":"publisher","first-page":"e11423","DOI":"10.1097\/MD.0000000000011423","volume":"97","author":"YF Xu","year":"2018","unstructured":"Xu YF, Le XF, Tian W, et al. Computer-assisted, minimally invasive transforaminal lumbar interbody fusion: one surgeon\u2019s learning curve A STROBE-compliant article. Medicine (Baltimore). 2018;97(27):e11423.","journal-title":"Medicine (Baltimore)"},{"issue":"Suppl 2","key":"9577_CR23","first-page":"259","volume":"11","author":"P Park","year":"2015","unstructured":"Park P. Three-dimensional computed tomography-based spinal navigation in minimally invasive lateral lumbar interbody fusion: feasibility, technique, and initial results. Neurosurgery. 2015;11(Suppl 2):259\u201367.","journal-title":"Neurosurgery"},{"issue":"48","key":"9577_CR24","doi-asserted-by":"publisher","first-page":"e13484","DOI":"10.1097\/MD.0000000000013484","volume":"97","author":"J Jiang","year":"2018","unstructured":"Jiang J, Gan F, Tan H, et al. Effect of computer navigation-assisted minimally invasive direct lateral interbody fusion in the treatment of patients with lumbar tuberculosis: a retrospective study. Medicine (Baltimore). 2018;97(48):e13484.","journal-title":"Medicine (Baltimore)"},{"issue":"7","key":"9577_CR25","doi-asserted-by":"publisher","first-page":"657","DOI":"10.1177\/2192568217716149","volume":"7","author":"YH Zhang","year":"2017","unstructured":"Zhang YH, White I, Potts E, Mobasser JP, Chou D. Comparison perioperative factors during minimally invasive pre-psoas lateral interbody fusion of the lumbar spine using either navigation or conventional fluoroscopy. Global Spine J. 2017;7(7):657\u201363.","journal-title":"Global Spine J"},{"issue":"2","key":"9577_CR26","doi-asserted-by":"publisher","first-page":"E14","DOI":"10.3171\/2017.5.FOCUS17168","volume":"43","author":"AM DiGiorgio","year":"2017","unstructured":"DiGiorgio AM, Edwards CS, Virk MS, Mummaneni PV, Chou D. Stereotactic navigation for the prepsoas oblique lateral lumbar interbody fusion: technical note and case series. Neurosurg Focus. 2017;43(2):E14.","journal-title":"Neurosurg Focus"},{"key":"9577_CR27","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1016\/j.clineuro.2018.10.013","volume":"175","author":"JN Sellin","year":"2018","unstructured":"Sellin JN, Mayer RR, Hoffman M, Ropper AE. Simultaneous lateral interbody fusion and pedicle screws (SLIPS) with CT-guided navigation. Clin Neurol Neurosurg. 2018;175:91\u20137.","journal-title":"Clin Neurol Neurosurg"},{"issue":"5","key":"9577_CR28","doi-asserted-by":"publisher","first-page":"608","DOI":"10.3171\/2013.7.SPINE121157","volume":"19","author":"TJ Gianaris","year":"2013","unstructured":"Gianaris TJ, Helbig GM, Horn EM. Percutaneous pedicle screw placement with computer-navigated mapping in place of Kirschner wires: clinical article. J Neurosurg Spine. 2013;19(5):608\u201313.","journal-title":"J Neurosurg Spine"},{"issue":"3","key":"9577_CR29","doi-asserted-by":"publisher","first-page":"E1","DOI":"10.3171\/2014.1.FOCUS13531","volume":"36","author":"TT Kim","year":"2014","unstructured":"Kim TT, Drazin D, Shweikeh F, Pashman R, Johnson JP. Clinical and radiographic outcomes of minimally invasive percutaneous pedicle screw placement with intraoperative CT (O-arm) image guidance navigation. Neurosurg Focus. 2014;36(3):E1.","journal-title":"Neurosurg Focus"},{"issue":"10","key":"9577_CR30","doi-asserted-by":"publisher","first-page":"1095","DOI":"10.1097\/BRS.0b013e3181bc39c6","volume":"35","author":"AL Tam","year":"2010","unstructured":"Tam AL, Mohamed A, Pfister M, et al. C-arm cone beam computed tomography needle path overlay for fluoroscopic guided vertebroplasty. Spine (Phila Pa 1976). 2010;35(10):1095\u20139.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"2 Suppl Operati","key":"9577_CR31","first-page":"ons250","volume":"68","author":"F Schils","year":"2011","unstructured":"Schils F. O-arm-guided balloon kyphoplasty: prospective single-center case series of 54 consecutive patients. Neurosurgery. 2011;68(2 Suppl Operative):ons250\u20136 discussion 256.","journal-title":"Neurosurgery"}],"container-title":["Current Reviews in Musculoskeletal Medicine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12178-019-09577-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s12178-019-09577-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s12178-019-09577-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,26]],"date-time":"2024-07-26T07:24:54Z","timestamp":1721978694000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s12178-019-09577-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,11,7]]},"references-count":31,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2019,12]]}},"alternative-id":["9577"],"URL":"https:\/\/doi.org\/10.1007\/s12178-019-09577-z","relation":{},"ISSN":["1935-9748"],"issn-type":[{"value":"1935-9748","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,11,7]]},"assertion":[{"value":"7 November 2019","order":1,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with Ethical Standards"}},{"value":"Jonathan N. Sembrano, MD has a research support from NuVasive, Inc. Sharon C. Yson, MD received a research support from SI-Bone, Inc. Jeffrey J. Theismann has no conflicts of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"No human or animal studies were conducted by authors for this manuscript.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Human and Animal Rights and Informed Consent"}}]}}