{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,20]],"date-time":"2026-01-20T03:32:26Z","timestamp":1768879946969,"version":"3.49.0"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,9,8]],"date-time":"2025-09-08T00:00:00Z","timestamp":1757289600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,9,8]],"date-time":"2025-09-08T00:00:00Z","timestamp":1757289600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J Hematol"],"published-print":{"date-parts":[[2026,1]]},"DOI":"10.1007\/s12185-025-04056-3","type":"journal-article","created":{"date-parts":[[2025,9,8]],"date-time":"2025-09-08T10:07:03Z","timestamp":1757326023000},"page":"75-80","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Accurate tacrolimus monitoring by dual peripherally inserted central catheters in allogeneic HSCT"],"prefix":"10.1007","volume":"123","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7497-6223","authenticated-orcid":false,"given":"Toshiro","family":"Sakai","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rie","family":"Shoji","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ryoji","family":"Tanaka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kyoko","family":"Yukitaka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ran","family":"Watanabe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuzufumi","family":"Sekiguchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ken","family":"Sato","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Saori","family":"Shimoyama-Ibuki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akari","family":"Goto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuichi","family":"Konuma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,9,8]]},"reference":[{"key":"4056_CR1","doi-asserted-by":"publisher","first-page":"389","DOI":"10.2169\/internalmedicine.56.7625","volume":"56","author":"Y Hashimoto","year":"2017","unstructured":"Hashimoto Y, Fukuta T, Maruyama J, Omura H, Tanaka T. Experience of peripherally inserted central venous catheter in patients with hematologic diseases. Intern Med. 2017;56:389\u201393.","journal-title":"Intern Med"},{"key":"4056_CR2","doi-asserted-by":"publisher","first-page":"592","DOI":"10.1007\/s12185-014-1677-9","volume":"100","author":"T Sakai","year":"2014","unstructured":"Sakai T, Kohda K, Konuma Y, Hiraoka Y, Ichikawa Y, Ono K, et al. A role for peripherally inserted central venous catheters in the prevention of catheter-related blood stream infections in patients with hematological malignancies. Int J Hematol. 2014;100:592\u20138.","journal-title":"Int J Hematol"},{"key":"4056_CR3","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1016\/j.jvn.2018.05.001","volume":"3","author":"I Madabhavi","year":"2018","unstructured":"Madabhavi I, Patel A, Sarkar M, Kataria P, Kadakol N, Anand A. A study of the use of peripherally inserted central catheters in cancer patients: a single-center experience. J Vasc Nurs. 2018;3:149\u201356.","journal-title":"J Vasc Nurs"},{"key":"4056_CR4","doi-asserted-by":"publisher","first-page":"2069","DOI":"10.1007\/s00277-022-04908-6","volume":"101","author":"Y Nakaya","year":"2022","unstructured":"Nakaya Y, Imasaki M, Shirano M, Shimizu K, Yagi N, Tsutsumi M, et al. Peripherally inserted central venous catheters decrease central line-associated bloodstream infections and change microbiological epidemiology in adult hematology unit: a propensity score-adjusted analysis. Ann Hematol. 2022;101:2069\u201377.","journal-title":"Ann Hematol"},{"key":"4056_CR5","doi-asserted-by":"publisher","first-page":"E656","DOI":"10.1002\/ajh.24903","volume":"92","author":"NS Fracchiolla","year":"2017","unstructured":"Fracchiolla NS, Todisco E, Bilancia A, Gandolfi S, Orofino N, Guidotti F, et al. Clinical management of peripherally inserted central catheters compared to conventional central venous catheters in patients with hematological malignancies: a large multicenter study of the REL group (Rete Ematologica Lombarda - Lombardy Hematologic Network, Italy). Am J Hematol. 2017;92:E656-9.","journal-title":"Am J Hematol"},{"key":"4056_CR6","doi-asserted-by":"publisher","first-page":"1654","DOI":"10.1111\/jocn.16020","volume":"31","author":"YH Shih","year":"2022","unstructured":"Shih YH, Teng CJ, Chen TC, Chang KH, Chen MH. Dual-lumen power injectable peripherally inserted central catheters in allogeneic hematopoietic stem cell transplantation: a prospective observational study. J Clin Nurs. 2022;31:1654\u201361.","journal-title":"J Clin Nurs"},{"key":"4056_CR7","doi-asserted-by":"publisher","DOI":"10.3390\/cancers15041338","volume":"15","author":"S Milczarek","year":"2023","unstructured":"Milczarek S, Kulig P, Zuchma\u0144ska A, Baumert B, Os\u0119kowska B, Bielikowicz A, et al. Safety of cryopreserved stem cell infusion through a peripherally inserted central venous catheter. Cancers (Basel). 2023;15: 1338.","journal-title":"Cancers (Basel)"},{"key":"4056_CR8","doi-asserted-by":"publisher","first-page":"131","DOI":"10.5301\/jva.5000803","volume":"19","author":"S Benvenuti","year":"2018","unstructured":"Benvenuti S, Ceresoli R, Boroni G, Parolini F, Porta F, Alberti D. Use of peripherally inserted central venous catheters (PICCs) in children receiving autologous or allogeneic stem-cell transplantation. J Vasc Access. 2018;19:131\u20136.","journal-title":"J Vasc Access"},{"key":"4056_CR9","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1016\/j.cca.2014.02.031","volume":"433","author":"C Hacker","year":"2014","unstructured":"Hacker C, Verbeek M, Schneider H, Steimer W. Falsely elevated cyclosporin and tacrolimus concentrations over prolonged periods of time due to reversible adsorption to central venous catheters. Clin Chim Acta. 2014;433:62\u20138.","journal-title":"Clin Chim Acta"},{"key":"4056_CR10","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1093\/ajcp\/aqx145","volume":"149","author":"AW Shih","year":"2017","unstructured":"Shih AW, Crowther MA, Jamula E, El-Sharkawy R, Brown M, Paterson G, et al. Assessment of the measurement error in cyclosporine levels drawn between peripheral and central sources. Am J Clin Pathol. 2017;149:76\u201381.","journal-title":"Am J Clin Pathol"},{"key":"4056_CR11","first-page":"42","volume":"26","author":"S Jha","year":"2018","unstructured":"Jha S, Sethi R. Thoracic vertebral body morphometry with its clinical implications. J Anat Sci. 2018;26:42\u20135.","journal-title":"J Anat Sci"},{"key":"4056_CR12","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1093\/bja\/aei310","volume":"96","author":"PA Stonelake","year":"2006","unstructured":"Stonelake PA, Bodenham AR. The carina as a radiological landmark for central venous catheter tip position. Br J Anaesth. 2006;96:335\u201340.","journal-title":"Br J Anaesth"},{"key":"4056_CR13","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1086\/599376","volume":"49","author":"LA Mermel","year":"2009","unstructured":"Mermel LA, Allon M, Bouza E, Craven DE, Flynn P, O\u2019Grady NP, et al. Clinical practice guidelines for the diagnosis and management of intravascular catheter-related infection: 2009 Update by the Infectious Diseases Society of America. Clin Infect Dis. 2009;49:1\u201345 (Erratum in: Clin Infect Dis. 2010; 50:1079. Dosage error in article text. Erratum in: Clin Infect Dis. 2010; 50:457).","journal-title":"Clin Infect Dis"},{"key":"4056_CR14","doi-asserted-by":"publisher","first-page":"645","DOI":"10.1016\/S1473-3099(07)70235-9","volume":"7","author":"I Raad","year":"2007","unstructured":"Raad I, Hanna H, Maki D. Intravascular catheter-related infections: advances in diagnosis, prevention, and management. Lancet Infect Dis. 2007;7:645\u201357.","journal-title":"Lancet Infect Dis"},{"key":"4056_CR15","doi-asserted-by":"publisher","first-page":"118","DOI":"10.32677\/EJMS.2019.v04.i03.003","volume":"4","author":"S Sapkota","year":"2019","unstructured":"Sapkota S, Badarkhe GV, Sannur R, Priyadarshini M, Naik R. Use of peripherally inserted central catheter is integral to supportive care in hematopoietic stem cells transplantation \u2013 a single centre study. East J Med Sci. 2019;4:118\u201322.","journal-title":"East J Med Sci"},{"key":"4056_CR16","doi-asserted-by":"publisher","first-page":"32","DOI":"10.7748\/paed.22.2.32.s29","volume":"22","author":"C Hands","year":"2010","unstructured":"Hands C, Round J, Thomas J. Evaluating venepuncture practice on a general children\u2019s ward. Paediatr Nurs. 2010;22:32\u20135.","journal-title":"Paediatr Nurs"},{"key":"4056_CR17","doi-asserted-by":"publisher","DOI":"10.5935\/1414-8145.20160078","volume":"20","author":"LB Campos","year":"2016","unstructured":"Campos LB, Martins JR, Arreguy-Sena C, da Silva AM, Vasconcelos Teixeira C, Carnevale de Souza L. Experiences of hospitalized patients with the venipuncture process. Escola Anna Nery. 2016;20: e20160078.","journal-title":"Escola Anna Nery"},{"key":"4056_CR18","doi-asserted-by":"publisher","first-page":"775","DOI":"10.33233\/eb.v18i6.3255","volume":"18","author":"C Arreguy-Sena","year":"2019","unstructured":"Arreguy-Sena C, Melo LD, Braga LM, Krempser P, Lemos RCPB, Lopes DP. Pun\u00e7\u00e3o de veias perif\u00e9ricas em adultos hospitalizados: m\u00e9todo misto sequencial aninhado. Enferm Brasil. 2019;18:775\u201383.","journal-title":"Enferm Brasil"},{"issue":"1","key":"4056_CR19","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1080\/10428194.2019.1646908","volume":"61","author":"N Scrivens","year":"2020","unstructured":"Scrivens N, Sabri E, Bredeson C, McDiarmid S. Comparison of complication rates and incidences associated with different peripherally inserted central catheters (PICC) in patients with hematological malignancies: a retrospective cohort study. Leuk Lymphoma. 2020;61(1):156\u201364.","journal-title":"Leuk Lymphoma"},{"key":"4056_CR20","first-page":"4193","volume":"28","author":"E Mariggi\u00f2","year":"2020","unstructured":"Mariggi\u00f2 E, Iori AP, Micozzi A, Chistolini A, Latagliata R, Berneschi P, et al. Peripherally inserted central catheters in allogeneic hematopoietic stem cell transplant recipients. Support Care Cancer. 2020;28:4193\u20139.","journal-title":"Support Care Cancer"},{"key":"4056_CR21","doi-asserted-by":"publisher","first-page":"1171","DOI":"10.1016\/j.ajic.2022.01.016","volume":"50","author":"T Gao","year":"2022","unstructured":"Gao T, Zhu X, Zeng Q, Li X, Luo M, Yu C, et al. Peripherally inserted central catheter-related bloodstream infections in patients with hematological malignancies: a retrospective 7-years single-center study. Am J Infect Control. 2022;50:1171\u20137.","journal-title":"Am J Infect Control"},{"key":"4056_CR22","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0010840","volume":"5","author":"L Slobbe","year":"2010","unstructured":"Slobbe L, Doorduijn JK, Lugtenburg PJ, El Barzouhi A, Boersma E, van Leeuwen WB, et al. Prevention of catheter-related bacteremia with a daily ethanol lock in patients with tunnelled catheters: a randomized, placebo-controlled trial. PLoS ONE. 2010;5:e10840.","journal-title":"PLoS ONE"}],"container-title":["International Journal of Hematology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12185-025-04056-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12185-025-04056-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12185-025-04056-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,19]],"date-time":"2026-01-19T15:02:40Z","timestamp":1768834960000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12185-025-04056-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,8]]},"references-count":22,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026,1]]}},"alternative-id":["4056"],"URL":"https:\/\/doi.org\/10.1007\/s12185-025-04056-3","relation":{},"ISSN":["0925-5710","1865-3774"],"issn-type":[{"value":"0925-5710","type":"print"},{"value":"1865-3774","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,8]]},"assertion":[{"value":"16 April 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 August 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 August 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 September 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}